ST Engineering Telematics Wireless XMETER21 Water meter reader User Manual DTMW Rev1 doc

Telematics Wireless Ltd. Water meter reader DTMW Rev1 doc

User Manual

DIALOG®®®® 3G USER’S FCC ID: NTAXMETER21 WATER
 2  Overview _____________________________________________________________________________________________ 1 Document Contents Overview___________________________________________________________________________ 1 Documentation Conventions ____________________________________________________________________________ 1 Documentation ______________________________________________________________________________________ 1 Conventions_________________________________________________________________________________________ 1 Document Contents Overview___________________________________________________________________________ 1 Documentation Conventions ____________________________________________________________________________ 1 Documentation ______________________________________________________________________________________ 1 Conventions_________________________________________________________________________________________ 1 See Contents on page iii for the complete table of contents ____________________________________________________ 1 Patent Notice________________________________________________________________________________________ 1 Compliance Statement ________________________________________________________________________________ 1 Transmission Duty Cycle_______________________________________________________________________________ 1 Trademark Notice ____________________________________________________________________________________ 6 Patent Notice________________________________________________________________________________________ 6 Compliance Statement ________________________________________________________________________________ 6 Identification ________________________________________________________________________________________ 1 Trademark Notice ____________________________________________________________________________________ 1 Patent Notice________________________________________________________________________________________ 1 Compliance Statement ________________________________________________________________________________ 1 Transmission Duty Cycle_______________________________________________________________________________ 1 Trademark Notice ____________________________________________________________________________________ 1 Patent Notice________________________________________________________________________________________ 1 Compliance Statement ________________________________________________________________________________ 1 Transmission Duty Cycle_______________________________________________________________________________ 1 Transportation Classification ____________________________________________________________________________ 1 Product Return ______________________________________________________________________________________ 1 Document Ideas & Suggestions _________________________________________________________________________ 1 Performance:________________________________________________________________________________________ 8 Leak Detection: ______________________________________________________________________________________ 8 Tamper: ____________________________________________________________________________________________ 8 Theft: ______________________________________________________________________________________________ 8 Zero Consumption: ___________________________________________________________________________________ 8 Data Logging: _______________________________________________________________________________________ 8 Batteries: ___________________________________________________________________________________________ 8 Configurations: ______________________________________________________________________________________ 9
 3  Product Return ______________________________________________________________________________________ 1 Document Ideas & Suggestions _________________________________________________________________________ 1 Product Return ______________________________________________________________________________________ 1 Document Ideas & Suggestions _________________________________________________________________________ 1
 4  The DIALOG® 3G endpoint (DTMW) is an RF transceiver used to communicate metered consumption data in Automatic Meter Reading (AMR) systems.  3G features an exclusive design that completely encapsulates the encoder electronics, transceiver, antenna, and batteries under the register glass. A design called ConnectionFree™.              CAUTION: The User and the Installer should be aware that changes and modifications to the equipment not expressly approved by Master Meter could void warranty and the user's authority to operate the equipment.  Professionally trained personnel should install the equipment.  The antenna used for this transmitter must be installed to normally provide minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter   ATTENTION! This type of note is used to warn of potential physical harm to the user or hardware. It is critical that you pay strict attention to WARNING notes, read the information carefully, and heed the advice/instructions.    Chapter Chapter 1. Getting Started   Chapter 2. Installing the Description Provides an overview of the DTMW endpoint installation, including installation options, siting, and required tools.  Provides step-by-step instructions for wiring the endpoint to a register and installing the endpoint using the rod mount, on a wall or similar surface, or on a pipe. Convention  Hypertext links are blue. Example  See Co n t e n t s  on  pag e iii for the co m p le t e   t ab le  of conten t s    Before You Begin
 5  Cautionary  Note on  Repairs &  Modifications ATTENTION!: Attempts to repair a 3G endpoint by unauthorized personnel (any one other than a Master Meter factory certified professional) may subject the person to shock hazard scenario if removal of protective covers is attempted. Unauthorized repair may void the warranty and/or maintenance contract with your company. ATTENTION!: This unit cannot be modified and is not repairable. Modification of this device could cause non-compliance with FCC rules. Attempts to modify this device will void the warranty. ATTENTION!: Follow these procedures to avoid injury to yourself or others.
 6         DTMW - 3G Endpoint Installation Guide Tradem ar k   N o t ic e 3G is a registered trademark of Master Meter, Inc. All other product names and logos in this document are used for identification purposes only and may be trademarks or registered trademarks of their respective companies. Paten t  N o t i c e 3G intellectual property is protected by US and foreign patents, and/or patents pending. Compli a n c e   S t a tem en t   The digital portion of the transceiver has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help  This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation      The transmission duty cycle is limited by its design not to exceed 1.0% I d en t i f i c at i o n  Tradem ar k   N o t ic e  Paten t  N o t i c e   Compli a n c e   S t a tem en t             Transm is s i o n   Du ty  Cycle      General Admin
 7  The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When activated, endpoints are considered operating transmitters and receivers and cannot be shipped by air.   To comply with FCC, UN, and Department of Transportation regulations, all units must be returned in their original packaging following Master Meter’s Return Material Authorization (RMA) process.   We want to hear your ideas on how we might improve and add value to this document. If you have comments or suggestions on how we may improve this document, send them to: • Mail: Master Meter, Inc. Attention: Marketing  101 Regency Pkwy, Mansfield, TX 76063 • E-mail: mbutler@mastermeter.com • Phone: 1-800-635-8725 Transp o r t a t i o n   Cl assification   Product  Re turn   Docu m en t   I d e a s  & Suggestions
 8   The 3G endpoint for water is an AMR module fully integrated into the meter register that actively records consumption data, data logs this information, and provides a vigilant suite of Revenue Impact Alerts – Leak, Theft, Tamper, and Zero Consumption.  P er f o r m an c e : Consumption data is sent continually every 11 seconds in the unlicensed 902-928 MHz bandwidth at 63 mW power. An integral Real Time Clock (RTC) ensures consistency in the transmission cycle. 3G is available in a standard configuration for Master Meter products, as well as a universal design – the Interpreter  - which replaces the original register for most any bayonet top mount design such as, but not limited to; AMCO, Badger, Hersey, Neptune, Precision, and Sensus. Leak De te c t ion : actively monitors for continues rotation of the register gears, and if it does not stop for 4 hours, we raise an electronic flag. And if this flag stays up for 24 hours, we transmit an alarm. T a mp e r : 3G actively monitors against the use of magnetic tamper devices such as large speaker magnetic that are commonly used in a n attempt to magnetically decouple the register from the meter. Theft: 3G actively monitors for reverse flow movement using motion sensing components in the AMR module/register. This vigilant indicator protects against meter reversal (theft), incorrectly installed meter, and backflow situations. Zero Co n s u m p t ion : 3G monitors for extended periods of zero consumption and flags the account, notifying utility personnel of a possible stuck meter or vacated service. Data L o g g i n g :  4,000 points of scalable, customizable consumption data are continually stored inside the 3G module. Consumption resolution is possible down to the minute. B a t te r i e s : 3G uses dual non-replaceable long life lithium Thionyl Chloride batteries that allows for a generous 20 year warranted battery life About 3G
 9  Config u r a t i o n s : 3G endpoints may be installed in the following ways: • Installed on a new Master Meter product, or by retrofitting a standard register on an existing meter. • Retrofitting competitor products with the 3G Interpeter by swapping off the bayonet mounted standard register and replacing it with the 3G.
 10  The following materials are supplied by Master Meter: • Standard 3G register (figure 1)            • Mechanical tools such as screwdrivers, pliers and wrenches are not provided by Master Meter.  • Manual labor required to install or replace exiting registers and meter components is not included. Included Materials Figure 1 Materials not Included
 11   Installation Process Chart  New Meter Application Turn off water service Remove existing –or– in case of new construction, install new meter equipped with 3G register Restore water service. Check for leaks. 3G’s auto-activation technology begins as soon as water flows through the meter and turns register gearing.
 12   Installation Process Chart Retrofit Application Water service may remain on Remove existing standard Master Meter register Replace with new 3G Register 3G’s auto-activation technology begins as soon as water flows through the meter and turns register gearing.
 13   Installation Process Chart Non-Master Meter Retrofit Application             Water service may remain on Remove existing standard bayonet-mount register from meter bodyTransportation Classification Replace with new 3G Interpreter  mounting ring. Be sure to use correct brand-specific ring for meter being retTransportation Classification 3G’s auto-activation technology begins as soon as water flows through the meter and turns register gearing. Place 3G register inside ring and complete assembly with other housing pieces Insert locking pin in register housing to complete.
 14  Associated FCC ID Devices FCC ID: NTADMMR1 – Rx & Tx from / to DTMW FCC ID: NTAMMR1 - Rx & Tx from / to DTMW FCC ID: NTAMMR2 – Rx from DTMW  FCC ID: NTAMMR3 -  Rx from DTMW FCC ID: NTAEMMR1 - Rx & Tx from / to DTMW FCC ID: NTALCRSA - Rx from DTMW

Navigation menu