ST-100M Module
ST-100M User Manual
Revision: 0.1
SUNTECH INTERNATIONAL
ST-100M Module
Notice
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
OEM integrators and installers are instructed that the phrase. This device contains
transmitter FCC ID: WA2ST-100M must be placed on the outside of the host.
Warning: Exposure to Radio Frequency Radiation The radiated output
power of this device is far below the FCC radio frequency exposure
limits. Nevertheless, the device should be used in such a manner that
the potential for human contact during normal operation is minimized.
In order to avoid the possibility of exceeding the FCC radio
frequency exposure limits, human proximity to the antenna should
not be less than 20cm during normal operation. The gain of the
antenna for Cellular band must not exceed 1 dBi. The gain of the
antenna for PCS band must not exceed 1 dBi.
ST-100M Module
Revision History
Revision
Date
0.2
2008/05/27
Author
Erica Fu
Comments
Draft version
ST-100M Module
Table of Contents
Revision History....................................................................................................................................................... 2
Table of contents ..................................................................................................................................................... 4
1 Introduction................................................................................................................................................... 10
1.1 Overview .................................................................................................................................................. 10
1.2 References ............................................................................................................................................... 10
2 V.25ter AT Commands.................................................................................................................................. 11
2.1 ATA .......................................................................................................................................................... 11
2.2 ATD.......................................................................................................................................................... 11
2.3 ATE .......................................................................................................................................................... 12
2.4 ATH.......................................................................................................................................................... 13
2.5 ATI............................................................................................................................................................ 13
2.6 ATL........................................................................................................................................................... 13
2.7 ATO.......................................................................................................................................................... 14
2.8 ATP .......................................................................................................................................................... 14
2.9 ATQ.......................................................................................................................................................... 14
2.10 ATS0 ........................................................................................................................................................ 15
2.11 ATS3 ........................................................................................................................................................ 15
2.12 ATS4 ........................................................................................................................................................ 16
2.13 ATS5 ........................................................................................................................................................ 16
2.14 ATS6 ........................................................................................................................................................ 17
2.15 ATS7 ........................................................................................................................................................ 17
2.16 ATS8 ........................................................................................................................................................ 17
2.17 ATS10 ...................................................................................................................................................... 18
2.18 ATT........................................................................................................................................................... 18
2.19 ATV .......................................................................................................................................................... 19
2.20 ATX .......................................................................................................................................................... 19
2.21 ATZ........................................................................................................................................................... 20
2.22 AT&F ........................................................................................................................................................ 20
2.23 AT+GMI.................................................................................................................................................... 20
2.24 AT+GMM.................................................................................................................................................. 21
2.25 AT+GMR .................................................................................................................................................. 21
2.26 AT+IPR..................................................................................................................................................... 21
2.27 AT+ICF..................................................................................................................................................... 22
2.28 AT+DS...................................................................................................................................................... 22
2.29 AT+GCAP................................................................................................................................................. 23
ST-100M Module
3 07.07 AT Commands – General commands ................................................................................................ 24
3.1 AT+CGMI – Request manufacturer identification (Sec 5.1)....................................................................... 24
3.2 AT+CGMM – Request model identification (Sec 5.2) ................................................................................ 24
3.3 AT+CGMR – Request revision identification (Sec 5.3).............................................................................. 24
3.4 AT+CGSN – Request product serial number identification (Sec 5.4) ........................................................ 25
3.5 AT+CSCS – Select TE character set (Sec 5.5) ......................................................................................... 25
3.6 AT+CIMI – Request international mobile subscriber identity (Sec 5.6)...................................................... 26
4 07.07 AT Commands – Call Control commands ......................................................................................... 27
4.1 AT+CMOD – Call mode (Sec 6.4) ............................................................................................................. 27
4.2 AT+CHUP – Hang up call (Sec 6.5) .......................................................................................................... 27
4.3 AT+CBST – Select bearer service type (Sec 6.7) .................................................................................... 27
4.4 AT+CRLP – Radio Link Protocol (Sec 6.8)................................................................................................ 28
4.5 AT+CR – Service reporting control (Sec 6.9) ............................................................................................ 29
4.6 AT+CEER – Extended error report (Sec 6.10) .......................................................................................... 30
4.7 AT+CRC – Cellular result code (Sec 6.11) ................................................................................................ 30
4.8 AT+CSNS – Single Numbering Scheme (Sec 6.19).................................................................................. 31
4.9 AT+CVHU – Voice Hangup Control (Sec 6.20) ......................................................................................... 31
4.10 AT+CSDF – Settings Date Format (Sec 6.22)........................................................................................... 31
4.11 AT+CSIL – Silence Command (Sec 6.23) ................................................................................................. 32
4.12 AT+CSTF – Settings Time Format (Sec 6.24)........................................................................................... 33
5 07.07 AT Commands –Network Service related commands .................................................................... 34
5.1 AT+CREG – Network Registration (Sec 7.2)............................................................................................. 34
6 07.07 AT Commands –MT control and status command.......................................................................... 48
6.1 AT+CPAS – Phone activity status (Sec 8.1).............................................................................................. 48
6.2 AT+CFUN – Set Phone Functionality (Sec 8.2)......................................................................................... 48
6.3 AT+CPIN – Enter PIN (Sec 8.3) ................................................................................................................ 49
6.4 AT+CBC – Battery Charge (Sec 8.4)......................................................................................................... 50
6.5 AT+CSQ – Signal Quality (Sec 8.5) .......................................................................................................... 50
6.6 AT+CKPD – Keypad control (Sec 8.7) ...................................................................................................... 51
6.7 AT+CIND – Indicator control (Sec 8.9) ...................................................................................................... 52
6.8 AT+CCLK – Clock (Sec 8.15).................................................................................................................... 55
6.9 AT+CALA – Alarm (Sec 8.16).................................................................................................................... 55
7 07.05 SMS AT Commands............................................................................................................................ 76
7.1 AT+CSMS – Select Message Service (Sec 3.2.1)..................................................................................... 76
7.2 AT+CPMS – Preferred Message Storage (Sec 3.2.2) ............................................................................... 76
7.3 AT+CMGF – Message Format (Sec 3.2.3) ................................................................................................ 77
7.4 AT+CSCA – Service Center Address (Sec 3.3.1)...................................................................................... 77
7.5 AT+CSMP – Set Text Mode Parameters (Sec 3.3.2) ................................................................................ 77
ST-100M Module
7.6 AT+CSDH – Show Text Mode Parameters (Sec 3.3.3)............................................................................. 78
7.7 AT+CSCB – Select Cell Broadcast Message Types (Sec 3.3.4) ............................................................... 78
7.8 AT+CSAS – Save Settings (Sec 3.3.5) ..................................................................................................... 79
7.9 AT+CRES – Restore Settings (Sec 3.3.6) ................................................................................................. 79
7.10 AT+CNMI – New Message Indications to TE (Sec 3.4.1)....................................................................... 80
7.11 AT+CMGL(Text mode) – List Message (Sec 3.4.2) ............................................................................... 81
7.12 AT+CMGL(PDU mode) – List Message (Sec 4.1).................................................................................. 82
7.13 AT+CMGR(Text mode) – Read Message (Sec 3.4.3) ............................................................................ 82
7.14 AT+CMGR(PDU mode) – Read Message (Sec 4.2) .............................................................................. 83
7.15 AT+CNMA(Text mode) – New Message Acknowledgement to ME/TA (Sec 3.4.4)............................... 83
7.16 AT+CNMA(PDU mode) – New Message Acknowledgement to ME/TA (Sec 4.6) ................................. 83
7.17 AT+CMGS(Text mode) – Send Message (Sec 3.5.1) ............................................................................ 84
7.18 AT+CMGS(PDU mode) – Send Message (Sec 4.3)............................................................................... 84
7.19 AT+CMSS(Text mode) – Send Message from Storage(Sec 3.5.2) ........................................................ 84
7.20 AT+CMSS(PDU mode) – Send Message from Storage(Sec 4.7) .......................................................... 85
7.21 AT+CMGW(Text mode) – Write Message to Memory (Sec 3.5.3) ......................................................... 85
7.22 AT+CMGW(PDU mode) – Write Message to Memory (Sec 4.4)............................................................ 86
7.23 AT+CGMD – Delete Message (Sec 3.5.4) ............................................................................................. 86
7.24 AT+CMGC(Text mode) – Send Command (Sec 3.5.5) .......................................................................... 86
7.25 AT+CMGC(PDU mode) – Send Command (Sec 4.5) ............................................................................ 87
7.26 AT+CMMS – More Message to Send (Sec 3.5.6) .................................................................................. 87
ST-100M Module
1 Introduction
1.1 Overview
This document introduces the supported AT command set of MAUI project.
1.2 References
[1] 3GPP TS 27.007 V3.13.0 (2003-03)
[2] ETSI TS 27.005 V3.1.0 (2000-01)
[3] ITU-T V.25 ter (07/1997)
ST-100M Module
2 V.25ter AT Commands
2.1 ATA
2.1.1 Description
Answers and initiates a connection to an incoming call.
2.1.2 Format
Execution command : ATA
2.1.3 Field
Type
Short name
Parameter/comment
28800 Connected with data bit rate of 28800 bits/s (HSCSD)
19200 Connected with data bit rate of 19200 bits/s (HSCSD)
String
text
14400 Connected with data bit rate of 14400 bits/s (HSCSD)
9600 Connected with data bit rate of 9600 bits/s
4800 Connected with data bit rate of 4800 bits/s
2400 Connected with data bit rate of 2400 bits/s
2.1.4 Response
Execution command :
CONNECT
CONNECT
NO CARRIER
ERROR
2.2 ATD
2.2.1 Description
Initiates a phone connection, which may be data, facsimile (+FCLASS> 0), or voice (phone number terminated by
semicolon). The phone number used to establish the connection will consist of digits and modifiers, or a stored number
specification.
2.2.2 Format
Execution command : ATD
ST-100M Module
2.2.3 Field
Type
Short name
Parameter/comment
.0 1 2 3 4 5 6 7 8 9 +. Valid characters for origination
W The W modifier is ignored but is included for
compatibility reasons only
, The comma modifier is ignored but is included for
compatibility reasons only
; Informs the Infrared Modem that the number is a
voice number rather than a fax or data number
T The T modifier is ignored but is included only
for compatibility purposes
P The P modifier is ignored but is included only
String
dial string
for compatibility purposes
String text
28800 Connected with data bit rate of 28800 bits/s
(HSCSD)
19200 Connected with data bit rate of 19200 bits/s
(HSCSD)
14400 Connected with data bit rate of 14400 bits/s
(HSCSD)
9600 Connected with data bit rate of 9600 bits/s
4800 Connected with data bit rate of 4800 bits/s
2400 Connected with data bit rate of 2400 bits/s
2.2.4 Response
Execution command :
CONNECT
CONNECT
NO CARRIER
ERROR
OK
2.3 ATE
2.3.1 Description
The setting of this parameter determines whether or not the DCE echoes characters received from the
DTE during command state and online command state.
2.3.2 Format
Execution command : ATE[]
ST-100M Module
2.3.2 Field
Type
Short name
Parameter/comment
0 DCE does not echo characters during
Integer
value
command state and online command state.
1 DCE echoes characters during command
state and online command state.
2.3.4 Response
Execution command : OK
2.4 ATH
2.4.1 Description
Terminates a connection.
2.4.2 Format
Execution command : ATH
2.4.3 Response
Execution command :
NO CARRIER
OK
2.5 ATI
2.5.1 Description
Request Identification Information.
2.5.2 Format
Execution command : ATI[]
2.5.3 Field
Type
Short name
Integer
value
String
text
Parameter/comment
used to select from among
multiple types of identifying information
product information
10
ST-100M Module
2.5.4 Response
Execution command :
2.6 ATL
2.6.1 Description
Set volume of the monitor speaker.
2.6.2 Format
Execution command : ATL[]
2.6.3 Field
Type
Short name
Parameter/comment
0 Low speaker volume
Integer
value
1 Low speaker volume
2 Medium speaker volume
3 High speaker volume
2.6.4 Response
Execution command : OK
2.7 ATO
2.7.1 Description
Switch from on-line command mode to on-line data mode during an active call. Returns ERROR when not in
on-line command mode.
2.7.2 Format
Execution command : ATO
2.7.3 Field
Type
Short name
Parameter/comment
28800 Connected with data bit rate of 28800 bits/s (HSCSD)
19200 Connected with data bit rate of 19200 bits/s (HSCSD)
String
text
14400 Connected with data bit rate of 14400 bits/s (HSCSD)
9600 Connected with data bit rate of 9600 bits/s
4800 Connected with data bit rate of 4800 bits/s
2400 Connected with data bit rate of 2400 bits/s
11
ST-100M Module
2.7.4 Response
Execution command :
CONNECT
CONNECT
NO CARRIER
ERROR
2.8 ATP
2.8.1 Description
Select pulse dialing. (This setting is ignored.)
2.9 ATQ
2.9.1 Description
Set result code suppression mode.
2.9.2 Format
Execution command : ATQ[]
2.9.3 Field
Type
Short name
Integer
value
Parameter/comment
0 DCE transmits result codes.
1 Result codes are suppressed and not transmitted.
2.9.4 Response
Execution command : OK
2.10 ATS0
2.10.1 Description
Automatic answer.
This S-parameter controls the automatic answering feature of the DCE. If set to 0, automatic
answering is disabled. If set to a non-zero value, the DCE shall cause the DCE to answer when the
incoming call indication (ring) has occurred the number of times indicated by the value.
2.10.2 Format
Execution command : ATS0=
12
ST-100M Module
2.10.3 Field
Type
Short name
Integer
value
Parameter/comment
0 Automatic answering is disabled..
2.10.4 Response
Execution command : OK
2.11 ATS3
2.11.1 Description
Command line termination character
This S-parameter represents the decimal IA5 value of the character recognized by the DCE from the
DTE to terminate an incoming command line. It is also generated by the DCE as part of the header,
trailer, and terminator for result codes and information text, along with the S4 parameter (see the
description of the V parameter for usage).
2.11.2 Format
Execution command : ATS3=
2.11.3 Field
Type
Short name
Integer
value
Parameter/comment
13 Carriage return character (CR, IA5 0/13).
0 to 127 Set command line termination character to this value.
2.11.4 Response
Execution command : OK or ERROR
2.12 ATS4
2.12.1 Description
Response formatting character
This S-parameter represents the decimal IA5 value of the character generated by the DCE as part of
the header, trailer, and terminator for result codes and information text, along with the S3 parameter
(see the description of the V parameter for usage).
2.12.2 Format
Execution command : ATS4=
13
ST-100M Module
2.12.3 Field
Type
Short name
Integer
value
Parameter/comment
10 Line feed character (LF, IA5 0/10)..
0 to 127 Set response formatting character to this value.
2.12.4 Response
Execution command : OK or ERROR
2.13 ATS5
2.13.1 Description
Command line editing character.
This S-parameter represents the decimal IA5 value of the character recognized by the DCE as a
request to delete from the command line the immediately preceding character.
2.13.2 Format
Execution command : ATS5=
2.13.3 Field
Type
Short name
Integer
value
Parameter/comment
8 Backspace character (BS, IA5 0/8).
0 to 127 Set command line editing haracter to this value.
2.13.4 Response
Execution command : OK or ERROR
2.14 ATS6
2.14.1 Description
Pause before blind dialing.
The command is ignored.
14
ST-100M Module
2.15 ATS7
2.15.1 Description
Connection completion timeout.
This parameter specifies the amount of time, in seconds, that the DCE shall allow between either
answering a call (automatically or by the A command) or completion of signaling of call addressing
information to network (dialing), and establishment of a connection with the remote DCE. If no
connection is established during this time, the DCE disconnects from the line and returns a result
code indicating the cause of the disconnection.
2.15.2 Format
Execution command : ATS7=
2.15.3 Field
Type
Short name
Integer
value
Parameter/comment
1 to 255 Number of seconds in which connection must be
established or call will be disconnected.
2.15.4 Response
Execution command : OK or ERROR
2.16 ATS8
2.16.1 Description
Comma dial modifier time.
This parameter specifies the amount of time, in seconds, that the DCE shall pause, during signaling
of call addressing information to the network (dialing), when a "," (comma) dial modifier is
encountered in a dial string.
2.16.2 Format
Execution command : ATS8=
2.16.3 Field
Type
Short name
Parameter/comment
0 DCE does not pause when ","
encountered in dial string.
Integer
value
1 to 255 Number of seconds to pause.
Recommended default setting
2 DCE pauses two seconds when "," is
encountered.
15
ST-100M Module
2.16.4 Response
Execution command : OK or ERROR
2.17 ATS10
2.17.1 Description
Automatic disconnect delay.
This parameter specifies the amount of time, in tenths of a second, that the DCE will remain
connected to the line (off-hook) after the DCE has indicated the absence of received line signal. If the
received line signal is once again detected before the time specified in S10 expires, the DCE remains
connected to the line and the call continues.
2.17.2 Format
Execution command : ATS10=
2.17.3 Field
Type
Short name
Integer
value
Parameter/comment
1 to 254 Number of tenths of a
second of delay.
2.17.4 Response
Execution command : OK or ERROR
2.18 ATT
2.18.1 Description
We do not support.
This setting is ignored.
2.19 ATV
2.19.1 Description
Set DCE response format.
2.19.2 Format
Execution command : ATV[]
16
ST-100M Module
2.19.3 Field
Type
Short name
Parameter/comment
0 DCE transmits limited headers and
Integer
value
trailers and numeric text.
1 DCE transmits full headers and
trailers and verbose response text.
2.19.4 Response
Execution command : OK
2.20 ATX
2.20.1 Description
The setting of this parameter determines whether or not the DCE transmits particular result codes to
the DTE. It also controls whether or not the DCE verifies the presence of dial tone when it first goes
off-hook to begin dialing, and whether or not engaged tone (busy signal) detection is enabled.
However, this setting has no effect on the operation of the W dial modifier, which always checks for
dial tone regardless of this setting, nor on the busy signal detection capability of the W and @ dial
modifiers. See Table.
2.20.2 Format
Execution command : ATX[]
2.20.3 Field
Type
Short name
Parameter/comment
0 CONNECT result code is given upon entering online
data state. Dial tone and busy detection are
disabled.
1 CONNECT result code is given upon entering
online data state. Dial tone and busy detection are
disabled.
2 CONNECT result code is given upon entering
Integer
value
online data state. Dial tone detection is enabled,
and busy detection is disabled.
3 CONNECT result code is given upon entering
online data state. Dial tone detection is disabled,
and busy detection is enabled.
4 CONNECT result code is given upon entering
online data state. Dial tone and busy detection are
both enabled.
17
ST-100M Module
2.20.4 Response
Execution command : OK or ERROR
2.21 ATZ
2.21.1 Description
Reset to default configuration
2.21.2 Format
Execution command : ATZ[]
2.21.3 Field
Type
Short name
Integer
value
Parameter/comment
0 Set parameters to factory defaults.
2.21.4 Response
Execution command : OK or ERROR
2.22 AT&F
2.22.1 Description
Set to factory-defined configuration
2.22.2 Format
Set command : AT&F[]
2.22.3 Field
Type
Short name
Integer
value
Parameter/comment
0 Set parameters to factory
defaults.
2.22.4 Response
Set command: OK | ERROR | +CME ERROR:
18
ST-100M Module
2.23 AT+GMI
2.23.1 Description
Same as AT+CGMI
2.24 AT+GMM
2.24.1 Description
Same as AT+CGMM
2.25 AT+GMR
2.25.1 Description
Same as AT+CGMR
2.26 AT+IPR
2.26.1 Description
Specifies the data rate, in addition to 1200 bits/s or 9600 bits/s, at which the DCE will accept commands.
May be used to select operation at rates at which the DCE is not capable of automatically detecting the data
rate being used by the DTE.
2.26.2 Format
Execution command : AT+IPR=[]
Read command : AT+IPR? Displays the current setting.
Test command : AT+IPR=? Shows if the command is supported.
2.26.3 Field
Type
Short name
Parameter/comment
The rate, in bits per second, at which
the DTE-DCE interface should operate.
Currently, the following rates are
supported:
Integer
rate
0, 300, 1200, 2400, 4800, 9600, 14400,
19200, 28800, 38400, 57600, 115200,
230400, and 460800. If unspecified, or
set to zero, automatic detection is
selected, and the character format is
19
ST-100M Module
forced to auto-detect
(AT+ICF=0)
2.26.4 Response
Execution command : OK
Read command : +IPR:
Test command : +IPR: (list of supported s)
2.27 AT+ICF
2.27.1 Description
Determines the local serial-port asynchronous character framing.
2.27.2 Format
Execution command : AT+ICF=[[,]]
Read command : AT+ICF? Displays the current , settings.
Test command : AT+ICF=? Shows if the command is supported.
2.27.3 Field
Type
Short name
Parameter/comment
0 Auto-detect
1 8 Data bits, 2 Stop bits
2 8 Data bits, 1 Parity bit, 1 Stop bit
Integer
parity
3 8 Data bits, 1 Stop bit Default
setting
4 7 Data bits, 2 Stop bits
5 7 Data bits, 1 Parity bit, 1 Stop bit
6 7 Data bits, 1 Stop bit
0 Odd Default setting
Integer
parity
1 Even
2 Mark
3 Space
2.27.4 Response
Execution command : OK
Read command : +ICF: ,
Test command : +ICF: (list of supported s), (list of supported s)
20
ST-100M Module
2.28 AT+DS
2.28.1 Description
Controls the V.42 bis data compression function, if provided in the TA.
2.28.2 Format
Execution command : AT+DS=[[,[,[,]]]]
Read command : AT+DS? Displays the current , ,
, and settings.
Test command : AT+DS=? Shows if the command is supported.
2.28.3 Field
Type
Short name
Parameter/comment
0 Disable V.42bis
1 Enable V.42bis in transmit direction only
Integer
direction
2 Enable V.42bis in receive direction only
3 Enable V.42bis compression in both
directions Default setting
0 Accept connection if compression is
Integer
Compression_
negotiation
negotiated according to direction Default
setting
1 Disconnect if compression is not
negotiated according to direction
Integer
max_dict
Integer
max_string
512 to 4096 Maximum dictionary size
1024 Default setting
6 to 250 Maximum string length
32 Default setting
2.28.4 Response
Execution command : OK
Read command : +DS: ,,,
Test command : +DS: (list of supported s),(list of supported
s),(list of supported s),(list of supported
s)
2.29 AT+GCAP
2.29.1 Description
Request complete capabilities list.
21
ST-100M Module
2.29.2 Format
Execution command : AT+GCAP
Test command : AT+GCAP=? Shows if the command is supported.
2.29.3 Response
Execution command : +GCAP: +FCLASS, +CGSM
OK
Test command :
OK
22
ST-100M Module
3 07.07 AT Commands – General Commands
3.1 AT+CGMI – Request manufacturer identification (Sec 5.1)
3.1.1 Description
The command causes the phone to return one or more lines of information text which is
intended to permit the user of the ITAE/ETAE to identify the manufacturer of the phone to which it is
connected to.
3.1.2 Format
Command
+CGMI
Possible response(s)
+CME ERROR:
+CGMI=?
3.2 AT+CGMM – Request model identification (Sec 5.2)
3.2.1 Description
The command causes the phone to return one or more lines of information text which is intended to
permit the user of the ITAE/ETAE to identify the specific model of phone to which it is connected to.
3.2.2 Format
Command
+CGMM
Possible response(s)
+CME ERROR:
+CGMM=?
3.3 AT+CGMR – Request revision identification (Sec 5.3)
3.3.1 Description
The command causes the phone to return a string containing information regarding SW version.
3.3.2 Format
Command
+CGMR
Possible response(s)
+CME ERROR:
+CGMR=?
23
ST-100M Module
3.4 AT+CGSN – Request product serial number identification (Sec 5.4)
3.4.1 Description
Returns the IMEI number of the phone.
3.4.2 Format
Command
Possible response(s)
+CGSN
+CME ERROR:
+CGSN=?
3.5 AT+CSCS – Select TE character set (Sec 5.5)
3.5.1 Description
Set command informs TA which character set is used by the TE. TA is then able to convert
character strings correctly between TE and MT character sets.
3.5.2 Format
Command
Possible response(s)
+CSCS=[]
+CSCS?
+CSCS=?
+CSCS:
+CSCS: (list of supported
s)
3.5.3 Field
"GSM"
GSM 7 bit default alphabet (3GPP TS 23.038); this setting causes easily software flow
control (XON/XOFF) problems
"HEX"
character strings consist only of hexadecimal numbers from 00 to FF; e.g. "032FE6" equals
three 8-bit characters with decimal values 3, 47 and 230; no conversions to the original MT
character set shall be done.
"IRA"
international reference alphabet (ITU-T T.50 [13])
"PCCP437"
PC character set Code Page 437
"UCS2"
16-bit universal multiple-octet coded character set (ISO/IEC10646 [32]); UCS2 character
strings are converted to hexadecimal numbers from 0000 to FFFF; e.g. "004100620063"
equals three 16-bit characters with decimal values 65, 98 and 99
"8859-1"
ISO 8859 Latin character set
24
ST-100M Module
3.6 AT+CIMI – Request international mobile subscriber identity (Sec 5.6)3.6.1 Description
Execution command causes the TA to return , which is intended to permit the TE to identify the
individual SIM which is attached to ME. Refer [1] 9.2 for possible values.
3.6.2 Format
Command
+CIMI
Possible response(s)
+CME ERROR:
+CIMI=?
25
ST-100M Module
4 07.07 AT Commands – Call Control commands
4.1 AT+CMOD – Call mode (Sec 6.4)
4.1.1 Description
Selects the call mode for future dialing commands or for the next answering command.
4.1.2 Format
Command
Possible response(s)
+CMOD=[]
+CMOD?
+CMOD:
+CMOD=?
+CMOD: (list of supported s)
4.1.3 Field
:
single mode
alternating voice/fax (teleservice 61)
alternating voice/data (bearer service 61)
voice followed by data (bearer service 81)
4.2 AT+CHUP – Hang up call (Sec 6.5)
4.2.1 Description
Request to hang up the current GSM call.
4.2.2 Format
Command
Possible response(s)
+CHUP
+CHUP=?
+CMOD:
4.3 AT+CBST – Select bearer service type (Sec 6.7)
4.3.1 Description
Selects the bearer service with the data rate , and the connection element to be used
when data calls are made. Values may also be used during mobile-terminated data-call setup, especially in
the case of single numbering-scheme calls.
26
ST-100M Module
4.3.2 Format
Command
Possible response(s)
+CBST=[[,[,]]]
+CBST?
+CBST?
+CBST: ,,
+CBST: (list of supported s),(list of
supported s),(list of supported s)
4.3.3 Field
:
auto bauding (automatic selection of the speed; this setting is possible in case of 3.1 kHz
modem and non-transparent service)
2400 bps (V.22bis)
2400 bps (V.26ter)
4800 bps (V.32)
9600 bps (V.32)
12
9600 bps (V.34)
14
14400 bps (V.34)
68
2400 bps (V.110 or X.31 flag stuffing)
70
4800 bps (V.110 or X.31 flag stuffing)
71
9600 bps (V.110 or X.31 flag stuffing)
75
14400 bps (V.110 or X.31 flag stuffing)
[NOTE] when = 4,5,6,7,12,14 , line type = Analog
when =68,70,71,75 , line type = ISDN
:
data circuit asynchronous (UDI or 3.1 kHz modem)
:
transparent
non-transparent
both, transparent preferred
both, non-transparent preferred
4.4 AT+CRLP – Radio Link Protocol (Sec 6.8)
4.4.1 Description
Sets the radio link protocol parameters.
27
ST-100M Module
4.4.2 Format
Command
Possible response(s)
+CRLP=[[,[
,[,[,[,<
T4>]]]]]]
+CRLP: ,,,[,[,]]
[+CRLP:
+CRLP?
,,,[,[,]]
[...]]
+CRLP: (list of supported s),(list of supported s),
(list of supported s),(list of supported s)[,
[,(list of supported s)]]
[+CRLP: (list of supported s),(list of
+CRLP=?
supported
s),(list of supported s),(list of supported s)
[,[,(list of supported s)]]
[...]]
4.4.3 Field
, : RLP version number in integer format; only support version 0.
, , , , : IWF to MS window size, MS to IWF window size, acknowledgement timer
T1, retransmission attempts N2, re-sequencing period T4 in integer format. T1 and T4 are in units of 10
ms.
and in set command are ignored.
4.5 AT+CR – Service reporting control (Sec 6.9)
4.5.1 Description
Service reporting control.
Set command controls whether or not intermediate result code +CR: is returned from the TA to the
TE. If enabled, the intermediate result code is transmitted at the point during connect negotiation at which the
TA has determined which speed and quality of service will be used, before any error control or data
compression reports are transmitted, and before the intermediate result code CONNECT is transmitted.
4.5.2 Format
Command
Possible response(s)
+CR=[]
+CR?
+CR:
+CR=?
+CR: (list of supported s)
28
ST-100M Module
4.5.3 Field
:
0 disables reporting
1 enables reporting
:
ASYNC asynchronous transparent
SYNC synchronous transparent
REL ASYNC asynchronous non-transparent
REL SYNC synchronous non-transparent
4.6 AT+CEER – Extended error report (Sec 6.10)
4.6.1 Description
Execution command causes the TA to return one or more lines of information text , which offer the
user of the TA an extended report of the reason for
- the failure in the last unsuccessful call setup (originating or answering) or in-call modification;
- the last call release;
4.6.2 Format
Command
Possible response(s)
+CEER
+CEER: ,
+CEER=?
+CR:
4.6.3 Field
: cause value listed in GSM 04.08 annex H.
: string type describes cause value.
4.7 AT+CRC – Cellular result code (Sec 6.11)
4.7.1 Description
Set command controls whether or not the extended format of incoming call indication or GSM network
request for PDP context activation is used. When enabled, an incoming call is indicated to the TE with
unsolicited result code +CRING: instead of the normal RING.
4.7.2 Format
Command
Possible response(s)
+CRC=[]
+CRC?
+CRC:
+CRC=?
+CRC: (list of supported s)
29
ST-100M Module
4.7.3 Field
:
0 disables extended format
1 enables extended format
:
ASYNC
asynchronous transparent
SYNC
synchronous transparent
REL ASYNC
asynchronous non-transparent
REL SYNC
synchronous non-transparent
FAX
facsimile (TS 62)
VOICE
normal voice (TS 11)
VOICE/XXX
voice followed by data (BS 81)
(XXX is ASYNC, SYNC, REL ASYNC or REL SYNC)
ALT VOICE/XXX
alternating voice/data, voice first (BS 61)
ALT XXX/VOICE
alternating voice/data, data first (BS 61)
ALT VOICE/FAX
alternating voice/fax, voice first (TS 61)
ALT FAX/VOICE
alternating voice/fax, fax first (TS 61).
4.8 AT+CSNS – Single Numbering Scheme (Sec 6.19)
4.8.1 Description
Set command selects the bearer or teleservice to be used when mobile terminated single numbering scheme
call is established. Parameter values set with +CBST command shall be used when equals to a data
service.
4.8.2 Format
Command
Possible response(s)
+CSNS=[]
+CSNS?
+CSNS:
+CSNS=?
+CSNS: (list of supported s)
4.8.3 Field
:
voice
alternating voice/fax, voice first (TS 61)
fax (TS 62)
alternating voice/data, voice first (BS 61)
data
alternating voice/fax, fax first (TS 61)
alternating voice/data, data first (BS 61)
30
ST-100M Module
voice followed by data (BS 81)
4.9 AT+CVHU – Voice Hangup Control (Sec 6.20)
4.9.1 Description
Set command selects whether ATH or "drop DTR" shall cause a voice connection to be disconnected or not.
By voice connection is also meant alternating mode calls that are currently in voice mode.
4.9.2 Format
Command
Possible response(s)
+CVHU=[]
+CVHU?
+CVHU:
+CVHU=?
+CVHU:(list of supported s)
4.9.3 Field
: 0 - "Drop DTR" ignored but OK response given. ATH disconnects.
4.10 AT+CSDF – Settings Date Format (Sec 6.22)
4.10.1 Description
Set the date format of the date information presented to the user.
4.10.2 Format
Command
+CSDF=[[] [,]]
+CSDF?
Possible response(s)
+CME ERROR:
+CSDF:[,]
+CME ERROR:
+CSDF:(list of supported s)
+CSDF=?
[, (list of supported s)]
+CME ERROR:
4.10.3 Field
:
1 DD-MMM-YYYY
8 DD/MM/YYYY
9 MM/DD/YYYY
10 YYYY/MM/DD
11 YYYY-MM-DD
31
ST-100M Module
12 MMM DD,YYYY
:
1 yy/MM/dd (default)
2 yyyy/MM/dd
4.11 AT+CSIL – Silence Command (Sec 6.23)
4.11.1 Description
Enable/Disable the silent mode.
4.11.2 Format
Command
+CSIL=
Possible response(s)
+CME ERROR:
+CSIL:
+CSIL?
+CME ERROR:
+CSIL:(list of supported s)
+CSIL=?
+CME ERROR:
4.11.3 Field
:
0 Silent mode off
1 Silent mode on
4.12 AT+CSTF – Settings Time Format (Sec 6.24)
4.12.1 Description
Set time format of the time information presented to the user.
4.12.2 Format
Command
Possible response(s)
+CSTF=[]
+CME ERROR:
+CSTF?
+CSTF:
+CME ERROR:
+CSTF=?
+CSTF:(list of supported s)
+CME ERROR:
4.12.3 Field
:
1 HH:MM (24 hour clock)
2 HH:MM a.m./p.m.
32
ST-100M Module
5 07.07 AT Commands –Network Service Related Commands
5.1 AT+CREG – Network Registration (Sec 7.2)
5.1.1 Description
Set command controls the presentation of an unsolicited result code +CREG: when =1 and
there is a change in the MT network registration status, or code +CREG: [,,] when
=2 and there is a change of the network cell.
Read command returns the status of result code presentation and an integer which shows whether
the network has currently indicated the registration of the MT. Location information elements and
are returned only when =2 and MT is registered in the network.
5.1.2 Format
Command
Possible response(s)
+CREG=[]
+CREG?
+CREG=?
+CREG: ,[,,]
+CME ERROR:
+CREG: (list of supported s)
5.1.3 Field
:
0 disable network registration unsolicited result code
1 enable network registration unsolicited result code +CREG:
2 enable network registration and location information unsolicited result code
+CREG: [,,]
:
0 not registered, MT is not currently searching a new operator to register to
1 registered, home network
2 not registered, but MT is currently searching a new operator to register to
3 registration denied
4 unknown
5 registered, roaming
: string type; two byte location area code in hexadecimal format (e.g. "00C3" equals 195 in decimal)
: string type; two byte cell ID in hexadecimal format
33
ST-100M Module
6 07.07 AT Commands –MT Control and Status Command
6.1 AT+CPAS – Phone activity status (Sec 8.1)
6.1.1 Description
Returns the activity status of the ME. It can be used to interrogate the ME before requesting action
from the phone. If the command is executed without the parameter, only values from 0 to 128
are returned. If the parameter is included in the execution command, values from 129 to 255
may also be returned.
6.1.2 Format
Command
Possible response(s)
+CPAS:
+CPAS
+CME ERROR:
+CPAS: (list of supported s)
+CPAS=?
+CME ERROR:
6.1.3 Field
:
ready (MT allows commands from TA/TE)
unavailable (MT does not allow commands from TA/TE)
unknown (MT is not guaranteed to respond to instructions)
ringing (MT is ready for commands from TA/TE, but the ringer is active)
call in progress (MT is ready for commands from TA/TE, but a call is in progress)
asleep (MT is unable to process commands from TA/TE because it is in a low functionality state)
6.2 AT+CFUN – Set Phone Functionality (Sec 8.2)
6.2.1 Description
We only support full functionality so far.
AT+CFUN = 1, 1 can reset the target.
6.2.2 Format
Command
+CFUN=[[,]]
+CFUN=?
Possible response(s)
+CME ERROR:
+CFUN: (list of supported s), (list of supported s)
+CME ERROR:
34
ST-100M Module
6.2.3 Field
: 1
full functionality
: 0
do not reset the MT before setting it to power level
reset the MT before setting it to power level
6.3 AT+CPIN – Enter PIN (Sec 8.3)
6.3.1 Description
Set command sends to the ME a password which is necessary before it can be operated (SIM PIN, SIM PUK,
PH-SIM PIN, etc.). If the PIN is to be entered twice, the TA shall automatically repeat the PIN. If no PIN
request is pending, no action is taken towards ME and an error message, +CME ERROR, is returned to TE.
Refer [1] 9.2 for possible values.
If the PIN required is SIM PUK or SIM PUK2, the second pin is required. This second pin, , is used
to replace the old pin in the SIM.
6.3.2 Format
Command
+CPIN=[,]
Possible response(s)
+CME ERROR:
+CPIN:
+CPIN?
+CME ERROR:
+CPIN=?
6.3.3 Field
, : string type values
values reserved by the present document:
READY
MT is not pending for any password
SIM PIN
MT is waiting SIM PIN to be given
SIM PUK
MT is waiting SIM PUK to be given
PH-SIM PIN
MT is waiting phone to SIM card password to be given
PH-FSIM PIN
MT is waiting phone-to-very first SIM card password to be given
PH-FSIM PUK
MT is waiting phone-to-very first SIM card unblocking password to be given
SIM PIN2
MT is waiting SIM PIN2 to be given
SIM PUK2
MT is waiting SIM PUK2 to be given
PH-NET PIN
MT is waiting network personalization password to be given
PH-NET PUK
MT is waiting network personalization unblocking password to be given
PH-NETSUB PIN
MT is waiting network subset personalization password to be given
PH-NETSUB PUK
MT is waiting network subset personalization unblocking password to be given
PH-SP PIN
MT is waiting service provider personalization password to be given
PH-SP PUK
MT is waiting service provider personalization unblocking password to be given
PH-CORP PIN
MT is waiting corporate personalization password to be given
PH-CORP PUK
MT is waiting corporate personalization unblocking password to be given
PHONE LOCK
MT is waiting phone lock code
35
ST-100M Module
6.4 AT+CBC – Battery Charge (Sec 8.4)
6.4.1 Description
Execution and read command returns battery connection status and battery level of the ME.
6.4.2 Format
Command
Possible response(s)
+CBC: ,
+CBC
+CME ERROR:
+CBC=?
+CBC: (list of supported s),(list of supported