STARIAN TECHNOLOGY 1112 Baby Monitor User Manual 1
STARIAN TECHNOLOGY LIMITED Baby Monitor 1
User manual
QUICK START GUIDE FOR BABY MONITOR Model Name:ABM1111/ABM1112 Client:Delta 1. Packing List a) One BU (BABY) Transmitter b) One PU (PARENT) Receiver c) 2 AC adapters(5V/550mA ) d) Battery AAA x3(AAA alkaline batteries 3PCS, not included) e) User manual (not with it at the moment) 2. Overview of product 2.1.PU(PARENT) ①Speaker ②Volume down ③Power button ⑧Belt clip ④Volume Indicator ⑤Volume up ⑥ Communication Indicator ⑨Battery cover ⑦Power Indicator 2.2.BU(BABY) ①MIC ②Power button ③Power Indicator 3. Start to use ④ DC IN ⑩DC IN 3.1. PU receiver instructions Disassemble the battery cover screws by screwdriver. Insert three AAA alkaline batteries (Ensure the polarity of the batteries is right). Assemble the battery cover and fixed with screws. Note: Use battery or AC adapter as power supply. a Press the power button, power LED flashes green when powered by battery or power LED light on when powered by AC adaptor. b When battery voltage is lower than 3.4V the low battery alarm (BB sounds) voltage appears. When battery voltage is lower than 3.1V the device is switched off. The alarm should appear first then follow by the power LED off. You should replace the batteries when the device is in low power state. c The volume indicator is off when PU is idle and flashing when PU is in communication with BU. (Note: ABM1112 have this feature, ABM1111 without this feature) d Communication light off when PU is in communication. When PU is idle the green light flashes. 3.2. BU transmitter instructions a Connect the power adapter (5V 550MA) b After the device is powered up, the power LED will be on. (Hold power button for about 3 seconds) c Press the power button to change channel (a total of 12 channels can be changed, press the power button to change the channel if interference led to poor communication) 4. Communication Function a When PU and BU are power on, the two sides are automatically connected successfully. PU can receive signals transmitted (voice) by BU. b PU volume indicator will be on when receiving the signal, the greater the volume and signal of the receiver the indicator flashes more. c Default volume of PU receiver is 3 phases. d Users may adjust the volume by pressing the volume up/down button. (Total volume adjustment 5 phases) e When PU unable to receive signals from BU, communication LED (red) on. Communication LED will be off when PU is receiving signals. f Communication distance of PU and BU: i. Outdoor without any obstacles communication distance is up to 250 m. ii. Indoor depends on the status of obstacles. Note: Please switch off PU receiver when it is not in use. 5. Problem diagnosis and troubleshooting Reasons for PU cannot receive BU signal: a Whether power supply plugged in properly for BU, whether BU is switched off. b Whether there are nearby interference (WIFI or other device), press the power key once on BU to adjust to another channel. c Whether there are too many obstacles and, or too far away. 6. Product parameters 6.1 PU Receiver a Receiver Frequency:2.4G b Power Supply:AC110~240V DC IN 5V 2W Current consumption 400MA or AAA alkaline dry cell 3 (4.5V) c Operating Temperature:0°C-40°C/32°F-104°F 6.2 BU Transmitter a Transmitter Frequency:2.4G b Frequency:12 Channels(CH1:2413MHZ、CH2:2418MHZ、CH3:2423MHZ、CH4:2428MHZ CH5:2433MHZ、CH6:2438MHZ、CH7:2443MHZ、CH8:2448MHZ、CH9:2453MHZ、CH10: 2458MHZ CH11:2463MHZ、CH12:2468MHZ) c Power Supply:AC110~240V DC IN 5V 2W Current consumption 400MA d Operating Temperature:0°C-40°C/32°F-104°F FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 3 Language : zh-CN Tagged PDF : Yes Title : 1 Author : 微软用户 Creator : Microsoft® Office Word 2007 Create Date : 2013:12:23 14:54:08 Modify Date : 2013:12:23 14:54:08 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools