STI Select Alert Alarm Mini Controller SA5000 SA5000Install

User Manual: STI Select-Alert Alarm Mini Controller - STI-SA5000 Installation Instructions

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadSTI  Select-Alert Alarm Mini Controller - STI-SA5000 SA5000Install
Open PDF In BrowserView PDF
Select-Alert Alarm
Mini Controller
STI-SA5000 SERIES

·
· Use as a cabinet alarm, door alarm, ·
link with push button/switch or as a
·
burglar alarm.
· Independent strobe and siren timing
of 15 seconds, 30 seconds, 60
·
seconds or continuous.
· Durable, polycarbonate construction. ·
· Includes ten high intensity LED’s.
· Siren offers 32 user selectable tones.
· Choose piercing 100 or 85 dB alarm. ·

Features

For indoor use only.
Available with amber, green, blue,
red or white lens.
Includes a tamper switch which
triggers the alarm when unit is
being removed from a wall.
Low battery indicator.
Powered by a 9 VDC battery
(not included) or external 12 – 24
volts.
One Form “C” dry relay contact
output.

We protect the things that protect you.®

CONTENTS
Warnings and Cautions..............................................................................................page 3
Warranty Information..................................................................................................page 3
Dimensions...............................................................................................................page 3
Specifications............................................................................................................page 4
Electronic Setup.........................................................................................................page 4
Alarm Tones..............................................................................................................page 5
Alarm Timing and Volume...........................................................................................page 5
Terminal Strip Connections.........................................................................................page 6
Mounting Options.......................................................................................................page 6
Electronics.................................................................................................................page 8

SELECT-ALERT ASSEMBLY PARTS LIST
1 - 05000

Electronics Assembly

1 - 05050
4
4
2
2
2
1
1

Color Lens
Screw #6 x 5/8 in.
Screw #8-32 x 3/8 in.
Screw #6 x 1 1/4 in.
Anchor #8-10
Screw #6-32 x 1 1/2 in.
#8-32 x 1/2 in. tamper screw
Tamper wrench

ACCESSORIES
KIT-71100A-W
KIT-E18151
KIT-SA505
EBAT-9VDC
KIT-H18075

Backbox kit
N.C. reed switch and magnet
Key switch mounting bracket (includes key switch & 2 keys)
9 volt battery
Additional replacement key

-2-

WARNINGS
4.83 in.
All units are recommended
for indoor use. Unit must be tested periodically
to verify
3.25
in. the life of
battery. STI recommends you change the 9 Volt battery twice a year. When purchasing a SelectAlert, you will need to periodically test the connections to make sure audibles function at a sound
level to alert staff. Installer may need to purchase a simple audio-meter, typically available at your
local electronics store, to measure the sound in areas where the alarm is expected to be heard
in.
during normal noise environment. Results from this test may prove it beneficial to purchase
additional Select-Alert units.

All specifications and information shown are current as of publication and subject to change
without notice.

in.

WARRANTY INFORMATION

Three year guarantee4.75
against
in. breakage of polycarbonate housing in normal
3.05use
in. (one year on
electro mechanical and electronic components).
4.83 in.

3.22 in.

Electronic warranty form at www.sti-usa.com/wc14.

DIMENSIONS

3.25 in.
(83mm)

2.73 in.
(69mm)

1.58 in.
(40mm)

4.83 in.
(123mm)

FRONT

SIDE

-3-

OPEN
OFF

ON

ACTIVE

STAND BY

COM

NORMALLY

SPECIFICATIONS
CLOSED
FORM
"C"
Operating Voltage Internal power 9 VDC battery
(not included)
DRY CONTACTS
**MAIN POWER 32°F-120°
ALARM
Operating Temperature
CONTROL
SWITCH
Power Consumption Stand by: 50µA
		 Siren low volume: 85mA
		 Siren high volume: 90mA
		 Strobe: 25mA
Siren Volume Low: 85 dB
		 High: 100 dB
Alarm Timing Independent control for siren and strobe:
		 15s, 30s, 60s, continuous
Low Battery Warning LED flash once every 30 seconds
Form C Dry Contacts 0-30VAC/DC,
1 Amp
+
DC IN EY
SWK
CH
+Contacts reset ITafter
A
		
longest
alarm setting
ARM
SWLIT
REMOTE POWER IN
CH
N
ON
12-24
VDC, 125mA AlarmOFF
Key
Switch
on: normally
closed C COM NO
Alarm Switch Stand by: normally open contact required
NORMALLY OPEN
**MAIN POWER
Polycarbonate UL94V-2
CONTROL
COM
NORMALLY CLOSED
ACTIVE
Flammability Rating
FORM "C"
ALARM
SWITCH

STAND DRY CONTACTS
BY

INSTALLATION
Step 1 - Electronic Setup

S1
SIREN

ALARM TONES

S2
ALARM TIMING
STROBE TIMING
VOLUME

LED QTY 10
BATTERY
LOW BATTERY
INDICATOR LED
TERMINAL STRIP

BATTERY CABLE
WIRE ENTRY

TAMPER SWITCH
(REAR VIEW)

-4-

Step 2 - Alarm Tones - S1
S2

1
2
3
4
5
6
7
8
WIRE ENTRY
9
10
11
12
13
14
15
16

1 2 3 ALARM
4 5 TIMING
STROBE TIMING
BATTERY 0 0 0 0 VOLUME
0 BUZZ
1 0 0 0 0 SLOW ON/OFF
0 1 0 0 0 SLOW SIREN
1 1 0 0 0 3 BEEP/PAUSE/REPEAT
0 0 1 0 0 UFO FAST
1 0 1 0 0 FAST SIREN
BATTERY
0 1 1CABLE
0 0 #5 FAST
1 1 1 0 0 #2 MEDIUM
0 0 0 1 0 #5 MEDIUM
1 0 0 1 0 SWOOP MEDIUM
0 1 0 1 0 #3 MEDIUM
1 1 0 1 0 BUZZ TONE
0 0 1 1 0 STEADY FAST
10110
SWOOP SLOW
0 1 1 1 0 CONTINUOUS
1 1 1 1 0 FAST REPEAT

S1
1

17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

2345
0 0 0 0 1 STANDARD ALARM
1 0 0 0 1LED#3QTYFAST
10
0 1 0 0 1 #5 SLOW
1 1 0LOW
0 1BATTERY
FAST BEEP
LED
0 0 1INDICATOR
0 1 SOUND
A
STRIP
1 0 1 0TERMINAL
1 SOUND
B
0 1 1 0 1 SOUND C
TAMPER SWITCH
1 (REAR
1 1 0VIEW)
1 SOUND D
0 0 0 1 1 SOUND D LOUD
1 0 0 1 1 SOUND E
0 1 0 1 1 SOUND F
1 1 0 1 1 SOUND G
0 0 1 1 1 SOUND H
1 0 1 1 1 #4 LOW
0 1 1 1 1 SOUND K
+
1 1 1 1 1 CONTINUOUS
DC INFAST
KE

SIREN

ALARM TONES

REMOTE POWER IN
12-24 VDC, 125mA
(OPTIONAL)

+

-

SWIT Y
CH

OFF

ON

**MAIN POWER
CONTROL TO
KEY SWITCH

BATTERY

WIRE

A R
M
SWLA
ITCH

NC C
OM
NO

NORMAL
COM
ACTIVE

NOTE: Sound may be disabled
by
REED
SWITCH FROM CABINET
clipping wires to the siren.
THIS WILL VOID ALL WARRANTIES.
Remove two screws on circuit board;
leave enough length of wire to
possibly reattach in the future. Then
insulate wires to prevent shorting to
electronic components.

WIRES TO SIREN

Step 3 - Alarm Timing and Volume - S2
ALARM TIMING

1

1

2

STROBE TIMING

3

4

VOLUME

5

ON

0 OFF

*

Alarm
Timing
15 seconds

Siren
1 2
1 1

30 seconds
60 seconds
Continuous

1
0
0

0
1
0

1 = ON 0 = OFF
* Factory default settings

-5-

Strobe
3 4
1 1
1
0
0

0
1
0

NORMAL

FORM "C"
STAND DRY CONTACTS
BY

Volume
5
High
1
Low
0

Step 4 - Terminal Strip Connections
“DC IN” are the only polarity
sensitive terminals. When
external power is used, battery
will act as a backup. “Dry
Contacts: NC, COM, NO” are used
for remote alarm monitoring.

+

**Shipped with jumper wire
installed. Remove to add key
switch or other main power on/off
switch.

REMOTE POWER IN
12-24 VDC, 125mA
(OPTIONAL)

+

DC IN

-

OFF

-

EY
SWK
ITCH

ON

**MAIN POWER
CONTROL TO
KEY SWITCH

If using power only to trigger
alarm, add jumper to the alarm
switch terminals. If not using key
switch or other main power on/off,
key switch must also have jumper.

A AR
M
SWLIT
CH

NC C
OM
NO

NORMALLY OPEN
COM
ACTIVE

NORMALLY CLOSED

FORM "C"
STAND DRY CONTACTS
BY

REED
SWITCH FROM CABINET

Step 5 - Mounting Options
A) To STI Backbox SUB-71100A-W
1.Using 5/32 drill, drill through the (4) existing holes in back box (one in each corner).
2.Place back box on wall and mark the mounting hole positions.
3.If using #8-10 anchors, drill 3/16 dia. holes 1 in. deep into wall and press anchor into hole. If using #6 screws only,
drill 3/32 dia. holes 1 ¼ in. deep.
4.Mount back box to wall using #6 x 1 ¼ in. screws.
5.Mount base plate as shown using (2) #6-32 x 1 in. screws.
Note: If not using STI back box, make sure surface will depress tamper switch.
DRILL (4) 3/16 in. DIA. HOLES
IF USING #8-10 ANCHORS
DRILL (4) 3/32 in. DIA. HOLES
WHEN USING #6 SCREWS ONLY

DETAIL A
REMOVE THESE TABS
FROM ALL FOUR CORNERS

#8-10 ANCHOR
(4) PROVIDED KIT-SA504
BACKBOX
A

#6 x 1 1/4 in. SCREW
(4) PROVIDED
#6-32 X 5/8 in. SCREW
(2) PROVIDED

BASE PLATE

-6-

B) To Key DRILL
Mount Plate or into Wall without Electrical Box
3/16 DIA HOLES

KIT-SA505 KEY SWITCH
MOUNTING BRACKET

DRILL
3/16 DIA HOLES

KIT-SA505 KEY SWITCH
H18074
SWITCH LOCK
MOUNTING
BRACKET
#801 KEY
H18074 SWITCH
LOCK
#801 KEY

3 9/32 in.

BASE PLATE

3 9/32 in.

BASE
#6 xPLATE
1 1/4 in. SCREW
(2) PROVIDED
#6 x 1 1/4 in. SCREW
(2) PROVIDED

ANCHOR
#8-10
(2) PROVIDED
ANCHOR
#8-10
(2) PROVIDED

ENCLOSURE
ENCLOSURE

ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
ROUTE THE TWO KEY
SWITCH
WIRES
THROUGH
ROUTE
THE TWO
REED
THESWITCH
HOLE AS
SHOWN
WIRES
FROM
CABINET THROUGH THE
ROUTE THE TWO REED
HOLE AS SHOWN
SWITCH WIRES FROM
WIRE ACCESS
CABINETHOLE
THROUGH THE
HOLE AS SHOWN
WIRE ACCESS HOLE

C) To Single Gang Electrical Box

TO SINGLE GANG ELECTRICAL BOX

#6-32 x 1 1/2 in. SCREW
(2) PROVIDED
SINGLE GANG
ELECTRICAL BOX

BASE PLATE

-7-

Step 6 - Electronics Final Assembly
Wiring: After mounting
circuit board assembly,
connect wires. Refer to
terminal strip connections
(step 4).
Lens installation: Slide
lip of lens behind circuit
board mounting plate.
Rotate lens into position.
Secure with tamperproof
screw and special wrench.

05000 ELECTRONICS

05050- LENS COLORS
A - AMBER
B - BLUE
G - GREEN
R - RED
W - WHITE
TAMPER-PROOF SCREW

INSTALLED
BASE PLATE

WIRE ACCESS HOLE

TAMPER-PROOF
TOOL (1) PROVIDED

#8-32 x 3/8 in. SCREW
(4) PROVIDED

Step 7 - Operation
• Turn key switch on to arm.
• Cycle key switch to reset alarm.
• Alarm will sound when cover is removed, unit is removed from the wall or cabinet is opened
(alarm switch is electronically closed).
• To service, turn key switch off.

2306 Airport Rd • Waterford, MI 48327, USA
Phone: 248-673-9898 • Fax: 248-673-1246
info@sti-usa.com • www.sti-usa.com

Safety Technology International Ltd

Taylor House • 34 Sherwood Road • Bromsgrove
Worcestershire • B60 3DR • England • Tel: +44 (0)1527 520 999
Fax: +44 (0)1527 501 999 • info@sti-europe.com • www.sti-europe.com

Printed in USA				

Inst. Sht. SA5000, Sept2015



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.0-c060 61.134777, 2010/02/12-17:32:00
Create Date                     : 2016:12:01 11:46:07-05:00
Metadata Date                   : 2016:12:01 11:46:19-05:00
Modify Date                     : 2016:12:01 11:46:19-05:00
Creator Tool                    : Adobe InDesign CS5 (7.0.4)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 9126 bytes, use -b option to extract), (Binary data 7124 bytes, use -b option to extract)
Instance ID                     : uuid:3e9f66e7-797e-2b42-9503-68915440a387
Document ID                     : xmp.did:4AB471D3E62068118C148EB347AB9687
Original Document ID            : xmp.did:5E45DC38E62068118C148EB347AB9687
Rendition Class                 : proof:pdf
History Action                  : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:5E45DC38E62068118C148EB347AB9687, xmp.iid:6245DC38E62068118C148EB347AB9687, xmp.iid:E08E3D6AE62068118C148EB347AB9687, xmp.iid:A5ECEBC0E62068118C148EB347AB9687, xmp.iid:A6ECEBC0E62068118C148EB347AB9687, xmp.iid:4AB471D3E62068118C148EB347AB9687, xmp.iid:4BB471D3E62068118C148EB347AB9687, xmp.iid:318B65B3E82068118C148EB347AB9687, xmp.iid:F93C83F78E2968118083C235D41C0983, xmp.iid:08E561233B2A68118083C235D41C0983, xmp.iid:CE99DA96832568118083FF04F84918BC, xmp.iid:6D0145A4792968118083FF04F84918BC, xmp.iid:D8C47CC5792968118083FF04F84918BC, xmp.iid:34710DFED02068118C1483FB3BEE7DB2, xmp.iid:4FBD34D0E32068118C1483FB3BEE7DB2, xmp.iid:936F7C36E42068118C1483FB3BEE7DB2, xmp.iid:D64C86A0902168118C1483FB3BEE7DB2, xmp.iid:A69D127407206811808393F3100996D0, xmp.iid:A79D127407206811808393F3100996D0, xmp.iid:7E5DABE7922568118C14AC8C8C81AAEF, xmp.iid:E7C43E88A12168118083DF3494B506CD, xmp.iid:66F19FD5A12168118083DF3494B506CD, xmp.iid:61E800DEAA2168118083DF3494B506CD, xmp.iid:A20DDB14AB2168118083DF3494B506CD, xmp.iid:E08F1E87AC2168118083DF3494B506CD
History When                    : 2015:09:29 11:43:34-04:00, 2015:09:29 11:44:05-04:00, 2015:09:29 11:44:05-04:00, 2015:09:29 11:46:30-04:00, 2015:09:29 11:47:01-04:00, 2015:09:29 11:47:01-04:00, 2015:09:29 11:48:18-04:00, 2015:09:29 12:00:27-04:00, 2015:10:12 11:41:46-04:00, 2015:10:13 08:14:16-04:00, 2015:10:22 08:12:18-04:00, 2015:10:27 09:11:29-04:00, 2015:10:27 09:12:25-04:00, 2016:03:17 09:45:37-04:00, 2016:03:17 12:00:21-04:00, 2016:03:17 12:03:12-04:00, 2016:03:18 08:37:27-04:00, 2016:03:18 08:53:42-04:00, 2016:03:18 10:34:12-04:00, 2016:09:21 09:51:09-04:00, 2016:12:01 10:27:13-05:00, 2016:12:01 10:29:23-05:00, 2016:12:01 11:34:03-05:00, 2016:12:01 11:35:35-05:00, 2016:12:01 11:45:56-05:00
History Software Agent          : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0
History Changed                 : /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata
Derived From Instance ID        : xmp.iid:A6ECEBC0E62068118C148EB347AB9687
Derived From Document ID        : xmp.did:5E45DC38E62068118C148EB347AB9687
Derived From Original Document ID: xmp.did:5E45DC38E62068118C148EB347AB9687
Derived From Rendition Class    : default
Doc Change Count                : 63
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CS5 (7.0.4)
EXIF Metadata provided by EXIF.tools

Navigation menu