STI Select Alert Alarm Mini Controller SA5000 SA5000Install
User Manual: STI Select-Alert Alarm Mini Controller - STI-SA5000 Installation Instructions
Open the PDF directly: View PDF
.
Page Count: 8
| Download | |
| Open PDF In Browser | View PDF |
Select-Alert Alarm Mini Controller STI-SA5000 SERIES · · Use as a cabinet alarm, door alarm, · link with push button/switch or as a · burglar alarm. · Independent strobe and siren timing of 15 seconds, 30 seconds, 60 · seconds or continuous. · Durable, polycarbonate construction. · · Includes ten high intensity LED’s. · Siren offers 32 user selectable tones. · Choose piercing 100 or 85 dB alarm. · Features For indoor use only. Available with amber, green, blue, red or white lens. Includes a tamper switch which triggers the alarm when unit is being removed from a wall. Low battery indicator. Powered by a 9 VDC battery (not included) or external 12 – 24 volts. One Form “C” dry relay contact output. We protect the things that protect you.® CONTENTS Warnings and Cautions..............................................................................................page 3 Warranty Information..................................................................................................page 3 Dimensions...............................................................................................................page 3 Specifications............................................................................................................page 4 Electronic Setup.........................................................................................................page 4 Alarm Tones..............................................................................................................page 5 Alarm Timing and Volume...........................................................................................page 5 Terminal Strip Connections.........................................................................................page 6 Mounting Options.......................................................................................................page 6 Electronics.................................................................................................................page 8 SELECT-ALERT ASSEMBLY PARTS LIST 1 - 05000 Electronics Assembly 1 - 05050 4 4 2 2 2 1 1 Color Lens Screw #6 x 5/8 in. Screw #8-32 x 3/8 in. Screw #6 x 1 1/4 in. Anchor #8-10 Screw #6-32 x 1 1/2 in. #8-32 x 1/2 in. tamper screw Tamper wrench ACCESSORIES KIT-71100A-W KIT-E18151 KIT-SA505 EBAT-9VDC KIT-H18075 Backbox kit N.C. reed switch and magnet Key switch mounting bracket (includes key switch & 2 keys) 9 volt battery Additional replacement key -2- WARNINGS 4.83 in. All units are recommended for indoor use. Unit must be tested periodically to verify 3.25 in. the life of battery. STI recommends you change the 9 Volt battery twice a year. When purchasing a SelectAlert, you will need to periodically test the connections to make sure audibles function at a sound level to alert staff. Installer may need to purchase a simple audio-meter, typically available at your local electronics store, to measure the sound in areas where the alarm is expected to be heard in. during normal noise environment. Results from this test may prove it beneficial to purchase additional Select-Alert units. All specifications and information shown are current as of publication and subject to change without notice. in. WARRANTY INFORMATION Three year guarantee4.75 against in. breakage of polycarbonate housing in normal 3.05use in. (one year on electro mechanical and electronic components). 4.83 in. 3.22 in. Electronic warranty form at www.sti-usa.com/wc14. DIMENSIONS 3.25 in. (83mm) 2.73 in. (69mm) 1.58 in. (40mm) 4.83 in. (123mm) FRONT SIDE -3- OPEN OFF ON ACTIVE STAND BY COM NORMALLY SPECIFICATIONS CLOSED FORM "C" Operating Voltage Internal power 9 VDC battery (not included) DRY CONTACTS **MAIN POWER 32°F-120° ALARM Operating Temperature CONTROL SWITCH Power Consumption Stand by: 50µA Siren low volume: 85mA Siren high volume: 90mA Strobe: 25mA Siren Volume Low: 85 dB High: 100 dB Alarm Timing Independent control for siren and strobe: 15s, 30s, 60s, continuous Low Battery Warning LED flash once every 30 seconds Form C Dry Contacts 0-30VAC/DC, 1 Amp + DC IN EY SWK CH +Contacts reset ITafter A longest alarm setting ARM SWLIT REMOTE POWER IN CH N ON 12-24 VDC, 125mA AlarmOFF Key Switch on: normally closed C COM NO Alarm Switch Stand by: normally open contact required NORMALLY OPEN **MAIN POWER Polycarbonate UL94V-2 CONTROL COM NORMALLY CLOSED ACTIVE Flammability Rating FORM "C" ALARM SWITCH STAND DRY CONTACTS BY INSTALLATION Step 1 - Electronic Setup S1 SIREN ALARM TONES S2 ALARM TIMING STROBE TIMING VOLUME LED QTY 10 BATTERY LOW BATTERY INDICATOR LED TERMINAL STRIP BATTERY CABLE WIRE ENTRY TAMPER SWITCH (REAR VIEW) -4- Step 2 - Alarm Tones - S1 S2 1 2 3 4 5 6 7 8 WIRE ENTRY 9 10 11 12 13 14 15 16 1 2 3 ALARM 4 5 TIMING STROBE TIMING BATTERY 0 0 0 0 VOLUME 0 BUZZ 1 0 0 0 0 SLOW ON/OFF 0 1 0 0 0 SLOW SIREN 1 1 0 0 0 3 BEEP/PAUSE/REPEAT 0 0 1 0 0 UFO FAST 1 0 1 0 0 FAST SIREN BATTERY 0 1 1CABLE 0 0 #5 FAST 1 1 1 0 0 #2 MEDIUM 0 0 0 1 0 #5 MEDIUM 1 0 0 1 0 SWOOP MEDIUM 0 1 0 1 0 #3 MEDIUM 1 1 0 1 0 BUZZ TONE 0 0 1 1 0 STEADY FAST 10110 SWOOP SLOW 0 1 1 1 0 CONTINUOUS 1 1 1 1 0 FAST REPEAT S1 1 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 2345 0 0 0 0 1 STANDARD ALARM 1 0 0 0 1LED#3QTYFAST 10 0 1 0 0 1 #5 SLOW 1 1 0LOW 0 1BATTERY FAST BEEP LED 0 0 1INDICATOR 0 1 SOUND A STRIP 1 0 1 0TERMINAL 1 SOUND B 0 1 1 0 1 SOUND C TAMPER SWITCH 1 (REAR 1 1 0VIEW) 1 SOUND D 0 0 0 1 1 SOUND D LOUD 1 0 0 1 1 SOUND E 0 1 0 1 1 SOUND F 1 1 0 1 1 SOUND G 0 0 1 1 1 SOUND H 1 0 1 1 1 #4 LOW 0 1 1 1 1 SOUND K + 1 1 1 1 1 CONTINUOUS DC INFAST KE SIREN ALARM TONES REMOTE POWER IN 12-24 VDC, 125mA (OPTIONAL) + - SWIT Y CH OFF ON **MAIN POWER CONTROL TO KEY SWITCH BATTERY WIRE A R M SWLA ITCH NC C OM NO NORMAL COM ACTIVE NOTE: Sound may be disabled by REED SWITCH FROM CABINET clipping wires to the siren. THIS WILL VOID ALL WARRANTIES. Remove two screws on circuit board; leave enough length of wire to possibly reattach in the future. Then insulate wires to prevent shorting to electronic components. WIRES TO SIREN Step 3 - Alarm Timing and Volume - S2 ALARM TIMING 1 1 2 STROBE TIMING 3 4 VOLUME 5 ON 0 OFF * Alarm Timing 15 seconds Siren 1 2 1 1 30 seconds 60 seconds Continuous 1 0 0 0 1 0 1 = ON 0 = OFF * Factory default settings -5- Strobe 3 4 1 1 1 0 0 0 1 0 NORMAL FORM "C" STAND DRY CONTACTS BY Volume 5 High 1 Low 0 Step 4 - Terminal Strip Connections “DC IN” are the only polarity sensitive terminals. When external power is used, battery will act as a backup. “Dry Contacts: NC, COM, NO” are used for remote alarm monitoring. + **Shipped with jumper wire installed. Remove to add key switch or other main power on/off switch. REMOTE POWER IN 12-24 VDC, 125mA (OPTIONAL) + DC IN - OFF - EY SWK ITCH ON **MAIN POWER CONTROL TO KEY SWITCH If using power only to trigger alarm, add jumper to the alarm switch terminals. If not using key switch or other main power on/off, key switch must also have jumper. A AR M SWLIT CH NC C OM NO NORMALLY OPEN COM ACTIVE NORMALLY CLOSED FORM "C" STAND DRY CONTACTS BY REED SWITCH FROM CABINET Step 5 - Mounting Options A) To STI Backbox SUB-71100A-W 1.Using 5/32 drill, drill through the (4) existing holes in back box (one in each corner). 2.Place back box on wall and mark the mounting hole positions. 3.If using #8-10 anchors, drill 3/16 dia. holes 1 in. deep into wall and press anchor into hole. If using #6 screws only, drill 3/32 dia. holes 1 ¼ in. deep. 4.Mount back box to wall using #6 x 1 ¼ in. screws. 5.Mount base plate as shown using (2) #6-32 x 1 in. screws. Note: If not using STI back box, make sure surface will depress tamper switch. DRILL (4) 3/16 in. DIA. HOLES IF USING #8-10 ANCHORS DRILL (4) 3/32 in. DIA. HOLES WHEN USING #6 SCREWS ONLY DETAIL A REMOVE THESE TABS FROM ALL FOUR CORNERS #8-10 ANCHOR (4) PROVIDED KIT-SA504 BACKBOX A #6 x 1 1/4 in. SCREW (4) PROVIDED #6-32 X 5/8 in. SCREW (2) PROVIDED BASE PLATE -6- B) To Key DRILL Mount Plate or into Wall without Electrical Box 3/16 DIA HOLES KIT-SA505 KEY SWITCH MOUNTING BRACKET DRILL 3/16 DIA HOLES KIT-SA505 KEY SWITCH H18074 SWITCH LOCK MOUNTING BRACKET #801 KEY H18074 SWITCH LOCK #801 KEY 3 9/32 in. BASE PLATE 3 9/32 in. BASE #6 xPLATE 1 1/4 in. SCREW (2) PROVIDED #6 x 1 1/4 in. SCREW (2) PROVIDED ANCHOR #8-10 (2) PROVIDED ANCHOR #8-10 (2) PROVIDED ENCLOSURE ENCLOSURE ROUTE THE TWO KEY SWITCH WIRES THROUGH THE HOLE AS SHOWN ROUTE THE TWO KEY SWITCH WIRES THROUGH ROUTE THE TWO REED THESWITCH HOLE AS SHOWN WIRES FROM CABINET THROUGH THE ROUTE THE TWO REED HOLE AS SHOWN SWITCH WIRES FROM WIRE ACCESS CABINETHOLE THROUGH THE HOLE AS SHOWN WIRE ACCESS HOLE C) To Single Gang Electrical Box TO SINGLE GANG ELECTRICAL BOX #6-32 x 1 1/2 in. SCREW (2) PROVIDED SINGLE GANG ELECTRICAL BOX BASE PLATE -7- Step 6 - Electronics Final Assembly Wiring: After mounting circuit board assembly, connect wires. Refer to terminal strip connections (step 4). Lens installation: Slide lip of lens behind circuit board mounting plate. Rotate lens into position. Secure with tamperproof screw and special wrench. 05000 ELECTRONICS 05050- LENS COLORS A - AMBER B - BLUE G - GREEN R - RED W - WHITE TAMPER-PROOF SCREW INSTALLED BASE PLATE WIRE ACCESS HOLE TAMPER-PROOF TOOL (1) PROVIDED #8-32 x 3/8 in. SCREW (4) PROVIDED Step 7 - Operation • Turn key switch on to arm. • Cycle key switch to reset alarm. • Alarm will sound when cover is removed, unit is removed from the wall or cabinet is opened (alarm switch is electronically closed). • To service, turn key switch off. 2306 Airport Rd • Waterford, MI 48327, USA Phone: 248-673-9898 • Fax: 248-673-1246 info@sti-usa.com • www.sti-usa.com Safety Technology International Ltd Taylor House • 34 Sherwood Road • Bromsgrove Worcestershire • B60 3DR • England • Tel: +44 (0)1527 520 999 Fax: +44 (0)1527 501 999 • info@sti-europe.com • www.sti-europe.com Printed in USA Inst. Sht. SA5000, Sept2015
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.0-c060 61.134777, 2010/02/12-17:32:00 Create Date : 2016:12:01 11:46:07-05:00 Metadata Date : 2016:12:01 11:46:19-05:00 Modify Date : 2016:12:01 11:46:19-05:00 Creator Tool : Adobe InDesign CS5 (7.0.4) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 9126 bytes, use -b option to extract), (Binary data 7124 bytes, use -b option to extract) Instance ID : uuid:3e9f66e7-797e-2b42-9503-68915440a387 Document ID : xmp.did:4AB471D3E62068118C148EB347AB9687 Original Document ID : xmp.did:5E45DC38E62068118C148EB347AB9687 Rendition Class : proof:pdf History Action : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:5E45DC38E62068118C148EB347AB9687, xmp.iid:6245DC38E62068118C148EB347AB9687, xmp.iid:E08E3D6AE62068118C148EB347AB9687, xmp.iid:A5ECEBC0E62068118C148EB347AB9687, xmp.iid:A6ECEBC0E62068118C148EB347AB9687, xmp.iid:4AB471D3E62068118C148EB347AB9687, xmp.iid:4BB471D3E62068118C148EB347AB9687, xmp.iid:318B65B3E82068118C148EB347AB9687, xmp.iid:F93C83F78E2968118083C235D41C0983, xmp.iid:08E561233B2A68118083C235D41C0983, xmp.iid:CE99DA96832568118083FF04F84918BC, xmp.iid:6D0145A4792968118083FF04F84918BC, xmp.iid:D8C47CC5792968118083FF04F84918BC, xmp.iid:34710DFED02068118C1483FB3BEE7DB2, xmp.iid:4FBD34D0E32068118C1483FB3BEE7DB2, xmp.iid:936F7C36E42068118C1483FB3BEE7DB2, xmp.iid:D64C86A0902168118C1483FB3BEE7DB2, xmp.iid:A69D127407206811808393F3100996D0, xmp.iid:A79D127407206811808393F3100996D0, xmp.iid:7E5DABE7922568118C14AC8C8C81AAEF, xmp.iid:E7C43E88A12168118083DF3494B506CD, xmp.iid:66F19FD5A12168118083DF3494B506CD, xmp.iid:61E800DEAA2168118083DF3494B506CD, xmp.iid:A20DDB14AB2168118083DF3494B506CD, xmp.iid:E08F1E87AC2168118083DF3494B506CD History When : 2015:09:29 11:43:34-04:00, 2015:09:29 11:44:05-04:00, 2015:09:29 11:44:05-04:00, 2015:09:29 11:46:30-04:00, 2015:09:29 11:47:01-04:00, 2015:09:29 11:47:01-04:00, 2015:09:29 11:48:18-04:00, 2015:09:29 12:00:27-04:00, 2015:10:12 11:41:46-04:00, 2015:10:13 08:14:16-04:00, 2015:10:22 08:12:18-04:00, 2015:10:27 09:11:29-04:00, 2015:10:27 09:12:25-04:00, 2016:03:17 09:45:37-04:00, 2016:03:17 12:00:21-04:00, 2016:03:17 12:03:12-04:00, 2016:03:18 08:37:27-04:00, 2016:03:18 08:53:42-04:00, 2016:03:18 10:34:12-04:00, 2016:09:21 09:51:09-04:00, 2016:12:01 10:27:13-05:00, 2016:12:01 10:29:23-05:00, 2016:12:01 11:34:03-05:00, 2016:12:01 11:35:35-05:00, 2016:12:01 11:45:56-05:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata Derived From Instance ID : xmp.iid:A6ECEBC0E62068118C148EB347AB9687 Derived From Document ID : xmp.did:5E45DC38E62068118C148EB347AB9687 Derived From Original Document ID: xmp.did:5E45DC38E62068118C148EB347AB9687 Derived From Rendition Class : default Doc Change Count : 63 Format : application/pdf Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 8 Creator : Adobe InDesign CS5 (7.0.4)EXIF Metadata provided by EXIF.tools