User Guide
Mini Lecteur Etroit 13.56 MHz ARC ONE Notice d’installation 13.56 MHz Mini Mullion reader ARC ONE Installation procedure Sortie câble / Outputs : 3 m Sortie câble / Outputs Type x31 (Wiegand) Marron / Brown Rouge / Red Gris / Grey Bleu / Blue Jaune / Yellow Vert / Green Orange / Orange Blanc / White x31 (Clock & Data) x33 (RS485) 0 Vdc +Vcc (+10 Vdc à +15 Vdc) D0 Code NC D1 Data L+ Clock Clock LLed 1 Led 2 Buzzer Références des produits / Product references ARC1-R31-X-PH1-xx ARC1-R31-X-PC1-xx ARC1-R31-X-PH5-xx ARC1-S31-X-PH5-xx X: ARC1-R33-X-PH5-7AB ARC1-S33-X-PH5-7AB ARC1-W33-X-PH5-7AA ARC1-W33-X-PH5-7AD ARC1-R33-X-PH5-7AA + INT-R33-E/PH5-xx ARC1-S33-X-PH5-7AA + INT-E-7AA/7AB A Sortie Câble direct / Output cable B Sortie Câble avec connecteur / Output cable with connector Alimentation : Consommation max sous 12Vdc : Caractéristiques +10 Vdc à +15Vdc 130 mA (+12 Vdc typique) Power supply: Consumption max under 12Vdc: Characteristics +10 Vdc up to +15Vdc 130 mA (12 Vdc typical) Type de câble préconisé Utiliser un câble multiconducteur blindé par tresse. Dans le cas d'une télé-alimentation, utiliser : 1 paire 6/10è jusqu'à 30 m 1 paire 9/10è jusqu'à 50 m 2 paires 6/10è jusqu'à 60 m 2 paires 9/10è jusqu'à 100 m 3 paires 6/10è jusqu'à 100 m Déport max en RS485 : 600m (câble torsadé par paire). Buzzer / LED A la mise sous tension, pendant une durée d’environ une seconde, la LED est activée sur la couleur blanche et le buzzer émet un bip sonore. Le fonctionnement du buzzer et des LED 1 et 2 est configurable par badge de configuration (R3x & S3x) ou commandé par le système distant en appliquant un potentiel 0 Vdc respectivement sur les entrées « Led 1 », « Led 2 » et « Buzzer » ou pilotés par le protocole de communication du lecteur (W33). Fonction anti-arrachement L’état initial de l’accéléromètre est celui lu à la mise sous tension du lecteur. A chaque instant où cet état change, le lecteur détectera l’arrachement et : - pour R/S 31: émettra le signal d’arrachement sur la ligne « Data/Data1 ». Cette fonction est configurable par badge. - pour R/S 31 & 33 : effectuera les opérations configurées par badge de configuration - pour W33 : effectuera les opérations configurées via les commandes SSCP. Recommended cables Use a multi-conductor cable, pair shielded. When power is supplied with the same cable we recommend: 1 pair AWG24 for up to 30 m 1 pair AWG35 for up to 50 m 2 pairs AWG24 for up to 60 m 2 pairs AWG35 for up to 100 m 3 pairs AWG24 for up to 100 m Max length RS485: 600m / 1968 ft (twisted pair cable). Buzzer / LED When the reader is switched on, the white LED and the buzzer are activated. Attention : mettre le lecteur sous tension lorsqu’il est dans sa position finale. Configuration des lecteurs Les lecteurs R & S sont configurables par badge de configuration SCB créé avec SECard. - Si le SCB est compatible avec le firmware du lecteur, la LED devient verte et le buzzer retentit 5 fois. - Si le SCB n’est pas compatible avec le firmware du lecteur, la LED devient rouge et le buzzer est activé 1s. Précautions d'installation La tension d’alimentation aux bornes du lecteur doit être comprise entre +10 Vdc et +15 Vdc. Eloigner, autant que possible, le lecteur des câbles de transmission informatique ou d'origine de puissance (secteur ou Haute Tension). Les perturbations qu’ils peuvent engendrer varient en fonction de leur puissance de rayonnement et de leur proximité avec les lecteurs. Distance à respecter entre 2 lecteurs : Plans parallèles : 30 cm - Même plan : 40 cm - Plans perpendiculaires : 25 cm. Si le lecteur est fixé sur une surface métallique, il est possible d’avoir une réduction de la distance de lecture. Utiliser une ferrite (2 passages) sur le câble (alimentation et données). Exemple : Référence 74271222 WURTH ELEKTRONIK Utiliser une alimentation TBTS (Très Basse Tension de Sécurité) et source à puissance limitée. Câblage des pull-up en TTL Pour les signaux de données, des résistances de pulls-up de 10k au Vin (tension d’alimentation du lecteur) sont pré-équipées dans l’électronique du lecteur. Caution: switch on the reader when it is in its final position. Reader Configuration R & S readers are configurable with SCB configuration card created with SECard. - If the SCB is compatible with reader’s firmware, LED lights green and buzzer beeps 5 times. - If the SCB is not compatible with reader’s firmware, LED lights red and buzzer is activated 1s. The operating mode for Buzzer and LED 1 and 2 can be programmed by a configuration card (R3x & S3x) or driven by the remote system with a 0 Vdc respectively on the “Led 1”, “Led 2” and “Buzzer” inputs of the reader’s connector or driven by the communication protocol of the reader (W33). Anti-Tearing The initial status of accelerometer is memorized when the supply is turned on . When the reader is wrenched: - for R/S 31: will be emitted the wrenching signal on the line “Data/Data1”. This function can be defined by a specific card. - pour R/S 31 & 33: will do the operations configured with configuration card. - for W33: will do the operations configured through the SSCP protocol. Cautions for installation Supply voltage at the reader’s connector should be between +10 Vdc and +15 Vdc. Keep away, as much as possible, the reader from computer or power source cables. They can generate an electrical perturbation dependent of their radiation level and of proximity to reader. Recommended distance between 2 readers: Parallel plan: 30 cm – Same plan: 40 cm – Perpendicular plan: 25 cm. Reader installed on metallic surface may have reduced performances. Use a ferrite (2 ways) for the cable (Power supply and Data). Example: Reference 74271222 WURTH ELEKTRONIK Use a Safety extra-low Voltage supply and limited power source. TTL Pull-ups For Data signals, 10k pull-up resistors are connected internally to Vin (power supply voltage). Communication RS485 Communication RS485 Pour plus d’informations concernant le dialogue avec le lecteur, veuillez consulter la spécification du protocole. Vitesse de transmission Vitesse de transmission par défaut Mode Nombre de bits Mode de transmission Bit de stop RS485 More details about reader communication are available in the protocol specification. 9600, 19200, 38400, 57600, 115200 bauds ARC1 R & S : 9600 / ARC1 W : 38400 Asynchrone LSB first Adresse de diffusion par défaut 00h Baud rate Default Baud rate Mode Number of bits Transfer mode Stop bit RS485 9600, 19200, 38400, 57600, 115200 bauds ARC1 R & S: 9600 / ARC1 W: 38400 Asynchronous LSB first Default broadcast address 00h Architecture en bus (RS485) / Bus Architecture (RS485) +Vcc 1.5 kΩ UTL L+ L- 1.5 kΩ L+ L- L+ L- L+ L- © STid 2015 – 20 PA des Pradeaux FR13850 Gréasque – NI1110A01 - Ed. 06/01/2016 Mini Lecteur Etroit 13.56 MHz ARC ONE Notice d’installation 13.56 MHz Mini Mullion reader ARC ONE Installation procedure Dimensions du socle de fixation / Smart mounting plate dimensions Dimensions / Dimensions Fixation / Mounting Faire passer le câble dans la cavité du socle. Fixer le socle sur son emplacement final. Effectuer le raccordement du lecteur. Tester le fonctionnement. Placer le lecteur sur le socle (clipper le haut puis pivoter le vers le bas). Fixer le lecteur à l’aide de la vis et de l’embout fourni. Déclaration de conformité STid déclare que le lecteur ARC1-x3x-X est conforme aux exigences essentielles de la Directive R&TTE 1999/5/CE. Une copie de notre déclaration est disponible sur demande adressée à qualite@stid.com. Cet appareil est conforme à la Part-15 de la FCC. Son fonctionnement est soumis aux deux conditions suivantes : 1) Cet appareil ne doit pas causer d’interférence nuisible. 2) Cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant provoquer un fonctionnement indésirable. Pass the cable through the hole in the base. Screw the base to its final location. Connect the reader. Test the reading and communication. Place the reader on the base (clip the top part and then pivot it down). Lock the reader with the provided screws using the specific tool. Declaration of compliance STid declares that the reader ARC1-x3x-X is compliant to the essential requirements of the Directive R&TTE 1999/5/CE. A copy of our declaration is available upon request to qualite@stid.com. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized Note : Le fabricant n’est pas responsable des interférences radio ou TV causées par des modifications to this equipment. Such modifications could void the user’s authority to operate the modifications non autorisées de l’équipement. De telles modifications pourraient annuler le droit à equipment. l’utilisateur d’utiliser l’équipement. Adhérent “DEEE Pro” / “DEEE Pro” Adherent En réponse à la règlementation, STid finance la filière de recyclage de Récylum dédiée aux DEEE Pro qui reprend gratuitement les matériels électriques d’éclairage, les équipements de contrôle et de surveillance, et les dispositifs médicaux usagés. Plus d’informations sur www.recylum.com. In response to the regulation, STid finances the Récylum dedicated to DEEE Pro recycling chain. Lighting electrical equipment, control and monitoring devices, and used medical devices are taken back free of charge. More information on www.recylum.com. © STid 2015 – 20 PA des Pradeaux FR13850 Gréasque – NI1110A01 - Ed. 06/01/2016
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 2 Language : fr-FR Tagged PDF : Yes Author : C Pialoux Creator : Microsoft® Word 2010 Create Date : 2016:01:06 17:12:50+01:00 Modify Date : 2016:01:06 17:12:50+01:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools