Safety Technology 34501 Transmiter for use in wireless alert system User Manual CERTIFICATE OF COMPLIANCE

Safety Technology International, Inc. Transmiter for use in wireless alert system CERTIFICATE OF COMPLIANCE

User Manual

Download: Safety Technology 34501 Transmiter for use in wireless alert system User Manual CERTIFICATE OF COMPLIANCE
Mirror Download [FCC.gov]Safety Technology 34501 Transmiter for use in wireless alert system User Manual CERTIFICATE OF COMPLIANCE
Document ID1691421
Application IDEH/TT3bCMkp4cWozISeeog==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize45.72kB (571507 bits)
Date Submitted2012-05-07 00:00:00
Date Available2012-05-07 00:00:00
Creation Date2012-05-02 15:54:44
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2012-05-02 15:55:00
Document TitleCERTIFICATE OF COMPLIANCE
Document CreatorAcrobat PDFMaker 9.1 for Word
Document Author: Systems Administrator

Rhein Tech Laboratories, Inc.
360 Herndon Parkway
Suite 1400
Herndon, VA 20170
http://www.rheintech.com
Appendix J:
Manual
Please see the following pages.
Client: STI, Inc.
Model: 34501
Standards: FCC 15.231/IC RSS-210
ID’s: TXL34501/6335A-34501
Report #: 2012026
Installation and Operation Manual
STI Wireless Pool Alert
Model: STI-34501
Features and Specifications:
• Water/Weather resistant for outdoor use
• High output 85 dB alert siren (@ 10’)
• Low battery indicator
• Comes with magnet, bracket and mounting hardware
• One button bypass operation
• Safety feature: cover will not close if battery is not installed
• Acts as a stand-alone alert or works with an STI Wireless Alert Series
Receiver
• CR123, 3V Lithium battery operated (included)
• Material UV-Stabilized Polycarbonate
• UL 2017 Residential Water Hazard Entrance Alarm Equipment (pending)
Safety Technology
International, Inc.
“We Protect the Things that Protect You.”
Thank you for purchasing the STI Wireless Pool Alert. The Pool Alert can be used to provide a high
volume alert when a pool or spa area has been entered. It can be used outdoors on wood or metal gates
or indoors on doorways leading directly to potentially dangerous areas. STI Wireless Pool Alert is not a
substitute for supervision. Use as your “last line of defense.” Your satisfaction is important to us. Please
take the time to read this manual carefully to get the most from your product.
How the Product Works:
STI Wireless Pool Alert is designed to detect, by way of magnetic break, a door or gate opening, will sound an
85 dB alert and transmit a 433 MHz signal to an optional STI Wireless Alert Series Receiver.
Important Notes:
The STI Wireless Pool Alert, when properly installed, complies with UL 2017 Residential Water-Hazard Entrance
Alarm Equipment Type SM, Self-Monitored Alert System. Strict adherence to mounting height and orientation is
required for code; however, there may be additional local code requirements. The alert is not allowed to have a
power switch, nor is the cover allowed to be mounted to the base without a battery installed. The STI Wireless
Pool Alert can provide valuable protection when used correctly; however, it cannot guarantee protection against
accidents or injuries. Therefore, STI cannot be held responsible for any loss, damage or injury that may occur. It
is the user’s responsibility to test and maintain the operations of the STI Wireless Pool Alert. The STI Wireless Pool
Alert is water resistant, but not water proof. Do not submerge in water or allow water to enter through the locking
snap. Refer to Receiver instructions for wireless programming.
Operational States:
Normal – all door/gates closed
Pre-Alert – A series of double beeps 7 seconds before going into “Alert.” If door/gate is opened without pushing
“Bypass” button, unit enters “Pre-Alert” state immediately.
Bypass – press button before opening door/gate for a 15 second walk through with no alert sound. Button can be
pushed at any time to reset 15 second timer. Unit will go into “Alert” unless entry is closed.
Alert – full alert for opened door/gate. Red LED and 85 dB siren are continuous until the battery drains or button
pressed. Press button during “Alert” to initiate “Bypass.” During “Alert”, if the door/gate is closed, siren will sound
for 30 seconds, then return to normal state.
Low Battery indication – at Pool Alert – 1 short beep every minute
Optional receiver also has a low battery indication. See receiver instructions for information.
Operating Instructions:
Test and Program
REMOVING COVER - USING A SMALL FLAT
SCREWDRIVER, PLACE SCREWDRIVER TIP ONTO
SNAP COVER RELEASE AND PUSH IN GENTLY
WHILE LIFTING COVER AT THE SAME TIME.
1. Before mounting remove cover (Fig. 1).
2. Place magnet next to magnetic switch (location shown
Fig. 4) then remove the Pink Mylar battery tab. Green LED
flashes 1 time every 30 seconds (Normal State).
3. Move magnet away from magnetic switch. Pool Alert
should make a series of double beeps and red LED
flashes for approximately 7 seconds (Pre-Alert State),
then alarm sounds and red LED is solid (Alert State).
4. Press Button - Pool Alert is silent (Bypass State) for approximately 8 seconds, then
enters “Pre-Alert State.”
5. Press Button - Pool Alert is silent.
6. Move magnet near magnetic switch (Normal State).
7. If using wireless transmitter, refer to receiver instructions for programming.
SNAP COVER
RELEASE
FIG. 1
Installation:
Notes:
• Pool Alert must be mounted with snap cover
release toward ground or to the right side
5 in.
mm)
(Fig. 2).
• Plan installation so the magnet center can
be mounted within ¾ inch, or less of the
magnet center locator mark on the Pool
Alert housing (Fig. 3).
1.26 in.
• Recommend
mounting Pool Alert to a
(32mm)
GURE 5
stationary object of entry and magnet to
door/gate.
• For mounting convenience there is a
magnetic switch located on each side of the
Pool Alert. Only one magnet is required for
operation.
Screw Mounting (Fig. 4)
1. Remove Battery.
2. For compliance with UL 2017, drill 1 hole,
57” or greater above ground.
3. Insert anchor (if used) then screw. Leave
screw head exposed approximately 1/8”.
4. Slide teardrop slot on back of Pool Alert
onto screw and push up.
5. Mark bottom hole, move Pool Alert to side
(out of way) and drill.
6. Realign Pool Alert with mounting hole and
install screw. DO NOT OVERTIGHTEN.
Post Mounting (Fig. 5)
1. Strap mounting bracket to post using
straps as shown.
2. Slide teardrop slot on back of Pool Alert
onto the mounting bracket and push up.
3. Secure Pool Alert base to mounting
bracket with the #6-32 x 3/8” screw
provided.
Magnet Mounting (Fig. 3)
1. Mount on door or gate with center of
magnet aligned with center of magnetic
switch using screws or double sided tape
(not included).
2. When mounting on a steel surface, use
plastic spacers provided.
3. Install battery and cover (Fig. 6).
4. Test Pool Alert.
WHEN MOUNTING VERTICAL, SNAP COVER
RELEASE MUST BE AT BOTTOM.
(FOR INDOOR MOUNTING ONLY)
WHEN MOUNTING HORIZONTALLY,
SNAP COVER RELEASE MUST BE TO
THE RIGHT.
SNAP COVER
RELEASE
SNAP COVER RELEASE
FIG. 2
DRILL 3/32”
MAX
3/4 in.
(19mm)
1.57 in.
(40mm)
MAGNET
MOUNTING
CENTER
LOCATOR
MAGNET
5.2 in.
(131mm)
BYPASS SWITCH
1.5 in.
(38mm)
1.3 in.
(32mm)
FIG. 3
IF USING ANCHORS, DRILL
3/16 in. DIA. HOLES
IF USING SCREWS ONLY,
DRILL 7/64 in. DIA. HOLES
WHEN MOUNTING VERTICAL, SNAP COVER
RELEASE MUST BE AT BOTTOM.
DOOR JAM
/GATE
POST
(FOR INDOOR
MOUNTING
ONLY)
WHEN MOUNTING HORIZONTALLY,
SNAP COVER RELEASE MUST BE TO
THE RIGHT.
ANCHOR
(2) PROVIDIED
#6 x 1 in. SCREW
(2) PROVIDED
SNAP CO
RELEASE
PINK MYLAR TAB
SNAP COVER RELEASE
MAGNETIC
SWITCH
57 in. MINIMUM MOUNTING
HEIGHT FROM THRESHOLD
POOL ALERT
BASE
FIG. 4
STEEL POST
TEAR DROP STEM
ZIP TIE
(NOT PROVIDED)
PINK MYLAR TAB
MOUNTING BRACKET
#6-32 x 3/8 SCREW
(1) PROVIDED
POOL ALERT BASE
MOUNTING BRACKET MUST BE
MINIMUM 57 INCHES FROM GROUND
FIG. 5
Battery Safety Guidelines and Precautions:
Do not expose batteries to high temperatures, moisture or direct sunlight. Do not place batteries on conductive surface (anti-static
mat, packaging bag or form trays) as it can cause the battery to short. Keep the battery contact terminal surfaces clean and free
from moisture and foreign matter. Before inserting the battery, check the battery contact terminals to make sure they are normal,
not bent or damaged. Bent terminals may not make good contact with the battery or may cause it to short-circuit.
Battery Replacement
Instructions:
1. Remove the cover from the backplate (Fig. 1).
2. Remove old battery and replace with a new CR123,
3V Lithium battery.
3. Reattach cover to the backplate (Fig. 6).
4. If battery is not installed correctly the cover will not
snap into place.
5. Dispose of battery properly in accordance with local
ordinances.
POOL ALERT COVER
CR123 BATTERY
POOL ALERT
BASE
SOUNDER
FIG. 6
Maintenance:
When the volume becomes low, or the unit does not produce normal alert sound, replace the CR123, 3V Lithium battery. The STI
Wireless Pool Alert’s plastic resists ultraviolet rays from direct sunlight exposure. However, slight discoloration over time is normal.
Recommend testing STI Wireless Pool Alert once a week.
Important Notice:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference that may be received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate this equipment.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
1. L’Appareil ne doit pas produire de brouillage, et
2. L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Model: 34501
FCC ID: TXL34501
IC: 6335A-34501
This product meets the applicable Industry Canada technical specifications.
Le présent matériel est conforme aux spécifications techniques applicables d’Industrie Canada.
Limited Warranty:
Safety Technology International, Inc. warrants to the original consumer/purchaser that this product shall be free of
defects in material and workmanship under normal use and circumstances for a period of one (1) year from the
date of original purchase for use.
IMPORTANT:
The use of the STI Wireless Pool Alert does not replace constant adult supervision!
Safety Technology
International, Inc.
2306 Airport Road • Waterford • Michigan • 48327-1209
Phone: 248-673-9898 • Toll Free: 800-888-4784 • Fax: 248-673-1246
Email: info@sti-usa.com • Web: www.sti-usa.com
Safety Technology International (Europe) Ltd.
Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch
Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only)
E-mail: info@sti-europe.com • Web: www.sti-europe.com
Install 34501, MAY2012

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Systems Administrator
Create Date                     : 2012:05:02 15:54:44-07:00
Modify Date                     : 2012:05:02 15:55:00-07:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2012:05:02 15:55-07:00
Creator Tool                    : Acrobat PDFMaker 9.1 for Word
Format                          : application/pdf
Title                           : CERTIFICATE OF COMPLIANCE
Creator                         : Systems Administrator
Document ID                     : uuid:8103a0ac-6746-4247-a0ea-c77115e6fb39
Instance ID                     : uuid:a04e16c9-f563-4da9-acad-0d661545f493
Producer                        : Adobe PDF Library 9.0
Page Count                      : 5
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TXL34501

Navigation menu