2_ safety information
safety information
CAUTION
RISK OF ELECTRIC SHOCK.
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
This symbol indicates that dangerous voltage consisting a risk of electric shock is
present within this unit.
This exclamation point symbol is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in the literature
accompanying the appliance.
WARNING
To reduce the risk of fi re or electric shock, do not expose this appliance to rain or moisture.
WARNING
Be sure to use only the standard adapter that is specifi ed in the specifi cation sheet.
Using any other adapter could cause fi re, electrical shock, or damage to the product.
Incorrectly connecting the power supply or replacing battery may cause explosion, fi re, electric shock, or damage to
the product.
Do not connect multiple controllers to a single adapter. Exceeding the capacity may cause abnormal heat generation or fi re.
Securely plug the power cord into the power receptacle. Insecure connection may cause fi re.
When installing the controller, fasten it securely and fi rmly. The fall of controller may cause personal injury.
Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or containers fi lled with water on top of the
controller. Doing so may cause personal injury due to fi re, electric shock, or falling objects.
Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fi re or electric shock.
If any unusual smells or smoke come from the unit, stop using the product. In such case, immediately disconnect the
power source and contact the service center. Continued use in such a condition may cause fi re or electric shock.
If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in
any way. (SAMSUNG is not liable for problems caused by unauthorized modifi cations or attempted repair.)
. When cleaning, do not spray water directly onto parts of the product. Doing so may cause fi re or electric shock.
CAUTION
Do not drop objects on the product or apply strong blows to it. Keep away from a location subject to excessive
vibration or magnetic interference.
Do not install in a location subject to high temperature (over 50°C), low temperature (below -10°C), or high humidity.
Doing so may cause fi re or electric shock.
If you want to relocate the already installed product, be sure to turn off the power and then move or reinstall it.
Remove the power plug from the outlet when there is a lighting storm. Neglecting to do so may cause fi re or damage
to the product.
Keep out of direct sunlight and heat radiation sources. It may cause fi re.
Install it in a place with good ventilation.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1.
2.
3.
4.
5.
6.
English English _ 3
SAFETY INFORMATION
Avoid aiming the controller directly towards extremely bright objects such as sun.
Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall be
placed on the apparatus.
The Mains plug is used as a disconnect device and shall stay readily operable at any time.
FCC Statement
Caution : Any changes or modifi cations in construction of this device which are not expressly approved by the
party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, any cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
7.
8.
9.
1)
2)
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifi ers) that
produce heat.
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one
wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third
prong is provided for your safety. If the provided plug does not fi t into your outlet, consult an electrician for
replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the
point where they exit from the apparatus.
Only use attachments/accessories specifi ed by the manufacturer.
Use only with cart, stand, tripod, bracket, or table specifi ed by the manufacturer, or sold with
the apparatus.
Unplug this apparatus when a card is used. Use caution when moving the cart/ apparatus
combination to avoid injury from tip-over.
Refer all servicing to qualifi ed service personnel. Servicing is required when the apparatus has been damaged in any
way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
IMPORTANT SAFETY INSTRUCTIONS
4_ contents
contents
PRODUCT INTRODUCTION
5
5 Features
6 What’s included
7 At a Glance
9 Cable Color Scheme
9 Cable Selection
INSTALLATION AND EXTERNAL
CONNECTION
10
10 Installing the Wall Mount
11 I/O Connection
14 Connecting to the external reader
INITIALIZATION
16
16 Initializing the system using the DIP switch
17 Display and Operation Status of Reader/
Register
18 To register/delete the master ID (card)
18 Communication Address Setup
19 Reader Mode and Authentication
USER MANAGEMENT
20
20 Registering the ID
20 To register the ID card along with the
ngerprint
21 To delete ID
OUTPUT FORMAT
22
22 WIEGAND Output (Default)
OTHER INFORMATION
23
23 How to register the fi ngerprint
TROUBLESHOOTING
24
24 TroubleShooting
PRODUCT SPECIFICATIONS
25
25 Product Specifi cations
Englis_ English _ 5
PRODUCT INTRODUCTION
FEATURES
This product is a fi ngerprint recognition reader that is compatible with the proximity reader. This product can be
synchronized with the controller, and is featured by reliable fi ngerprint recognition, all of which enables you to perform a
high level management of security and time and attendance. Integrated with the proximity reader and the fi ngerprint
recognition functions, this product will allow access to a user only if the card number matches the fi ngerprint of the user.
Easily installed on a doorframe or a fl at wall (simply replace the existing reader, if any), this product gives you high
satisfaction apart from the elegant looking appearance. The product’s reliable fi ngerprint recognition will keep you safe
from unauthorized access.
Reader Mode
RF Only Mode
- As soon as the card is authenticated, the corresponding card ID will be transferred to the controller.
RF+FINGER Mode
- As soon as the fi ngerprint is authenticated, the corresponding card ID will be transferred to the controller.
- For a person whose fi ngerprint is not registered, the product will automatically switch to RF Only mode.
Error Signal Output
If the product fails to authenticate a fi ngerprint or unregistered card, it will produce an error signal for 500 ms.
(However, if set to the Wiegand output format) The output format is of the open collector.
Output Format of Card Number
When a fi ngerprint is authenticated, the corresponding card number will be transferred in 26bit/34bit Wiegand.
Master Card
Used to switch between registration/deletion mode and reader mode.
Switching Operation Mode by External Input
This product can switch between RF Only and RF +Finger, according to the input setting of the product’s
system mode control line (gray with red stripes).
Card Number Input Format
The user ID read by the external reader or using the card or keypad will be transferred in 26bit Wiegand/34bit
Wiegand.
product introduction
6_ product introduction
product introduction
WHAT’S INCLUDED
Check if the following items are included in the product package.
Main Unit Wall Mount
3 x 30mm Screws (x2)
3.5 x 12mm Screws (x2)
3 x 6mm Screw (x1)
6 x 30mm Plastic Anchors (x2)
xGn
Cables (x4) Quick Guide CD Manual
tGj
Master Card (x1)
Englis_ English _ 7
PRODUCT INTRODUCTION
AT A GLANCE
Front Panel
LED Displays the status of the system operation.
Fingerprint Sensor Fingerprint scanner module.
Card Recognition Present a card to the marked area, and the product starts reading it.
Speaker Sounds a voice comment according to the user manipulation.
8_ product introduction
product introduction
Rear Panel
1Tamper Switch
Tamper switch.
Tamper switch.
2Fixing Screw Hole for a fi xing screw.
36-PIN Connector Can be connected to the Wiegand input and RS-485 communication cables.
48-PIN Connector Can be connected to the Wiegand output and signal output cables.
52-PIN Connector Can be connected to the power cable.
6RJ45 Connector Used in TCP/IP communications.
7DIP Switch Used to initialize the system or specify the communication addresses.
2
5
3 4
6
7
Englis_ English _ 9
PRODUCT INTRODUCTION
2-PIN Connector
I/O Pins Signal Cable Color
Power (+12V) DC +12V Red
Earth-grounding GND (-) Black
6-PIN Connector
I/O Pins Signal Cable Color
EX Input Wiegand DATA0 EX-DATA0 Pink
EX Input Wiegand DATA1 EX-DATA1 Sky Blue
NC Brown
NC Blue
8-PIN Connector
I/O Pins Signal Cable Color
Wiegand DATA 0 DATA-0 Green
Wiegand DATA 1 DATA-1 White
ERROR SIGNAL OUT ERROR SIGNAL OUT Orange
OK SIGNAL OUT OK SIGNAL OUT Orange with Black Stripes
TAMPER OUT TAMPER OUT Purple
EX_LED_CONTROL EX_LED_CONTROL Blue with White Stripes
EX_BUZZER_CONTROL EX_BUZZER_CONTROL White with Red Stripes
EX_SYS_CHANGE_IN EX_SYS_CHANGE_IN Gray with Red Stripes
TCP/IP (8PIN Connector) RJ45 cable connected
CABLE COLOR SCHEME
CABLE SELECTION
Item Cable Type
1Power (DC12V)
DC Power
Product
Belden #9409, 18 AWG 2 Conductor, Unshielded (Maximum Allowable Distance : Within 3m)
Belden #9409, 18 AWG 2 Conductor, Unshielded (Maximum Allowable Distance : Within 3m)
2
Wiegand I/O
Product
Controller connected
External Reader
Product
Belden #9512, 22 AWG 4 Conductor, Shielded
Belden #9514, 22 AWG 8 Conductor, Shielded
3Signal I/O
Controller
Product
Belden #9512, 22 AWG 4 Conductor, Shielded
Belden #9514, 22 AWG 8 Conductor, Shielded
10_ installation and external connection
installation and external connection
INSTALLING THE WALL MOUNT
Use 2 screws to fi x the Wall Mount on an appropriate point.
Drill a hole on the center of the Wall Mount so that the cables are arranged through it.
Take out the cables through the center hole.
Connect the cables to the 4 connectors as appropriate, and use one screw to fi x the Wall Mount with the
product.
1.
2.
3.
4.
3-Ø4.5
64.0
48.0
60.0
85.0
127.0
Englis_ English _ 11
INSTALLATION AND EXTERNAL CONNECTION
I/O CONNECTION
Overall Wiring Diagram
Buzzer Control
LED Control
System Mode Control
Controller
Hub
Authentication Success
Authentication Error
DATA1
DATA0
DC + 12V
GND(-)
TAMPER
CLK
DATA
Wiegand
White with red stripes
Blue with white stripes
Gray with red stripes
Orange with black stripes
Orange
White
Green
Red
Black
Purple
26bit/34bit
Wiegand
DATA1
DATA0
DC + 12V
GND(-)
External Reader
RJ45 Sky Blue Pink
12_ installation and external connection
installation and external connection
Input Connection
- Connection of External LED control
Connect the LED control input line (blue with white stripes) to the NO port of the controller relay output, and GND
to the COM port. Set I/O of the controller; now you can control turning on/off the green indicator. While the LED
control is working, the green indicator stays solid.
The controller can use the I/O settings to set the LED controller so that it displays the additional LED status for
authorized or unauthorized access upon user authentication. Furthermore, you can handle various situations
according to the I/O settings of the controller.
For more information about the I/O settings of the controller, refer to the user manual of the controller.
- Connection of External Buzzer Control
Connect the buzzer control input line (white with red stripes) to the NO port of the controller relay output, and
GND to the COM port. You can confi gure the I/O settings of the controller so that it sounds a beep. While
the buzzer control is working, the product keeps sounding the beep.
The controller can use the I/O settings to set the buzzer control so that it sounds an additional beep for
authorized or unauthorized access upon user authentication.
Furthermore, you can handle various situations according to the I/O settings of the controller.
For more information about the I/O settings of the controller, refer to the user manual of the controller.
- Connection of External System Mode Control (switching mode using external input)
Connect the system mode control line (gray with red stripes) to the NO port of the controller relay output, and
GND to the COM port. Set I/O of the controller; now you can control the system mode. While the system mode is
controlled, the product works in RF only mode.
With the I/O or time schedule settings, the controller can control to switch the system operation mode for a
specifi c timeline.
Furthermore, you can handle various situations according to the I/O settings of the controller.
For more information about the I/O settings of the controller, refer to the user manual of the controller.
POWER
12V GND
Buzzer Control
(White with red stripes)
LED Control
(Blue with white stripes)
System Mode Control
(Gray with red stripes)
CONTROLLER
Englis_ English _ 13
INSTALLATION AND EXTERNAL CONNECTION
Output Connection
- Wiegand DATA Output Connection
Connect the green line (Wiegand DATA 0) of the product to Wiegand DATA 0 of the controller.
Connect the white line (Wiegand DATA 1) of the product to Wiegand DATA 1 of the controller.
The product should be connected to GND(-) of the controller.
- Connection of Authentication Error Signal
Connect the orange line (authentication error signal) of the product to the input port of the controller.
With the I/O settings, the controller can transfer the authentication error event to the operating software program.
Furthermore, you can handle various situations according to the I/O settings of the controller.
- Connection of Authentication Success Signal
Connect the orange line with black stripes (authentication success signal) of the product to the corresponding
input port of the controller.
With the I/O settings, the controller can transfer the authentication success event to the operating software
program.
Furthermore, you can handle various situations according to the I/O settings of the controller.
1.
2.
3.
12V (red)
GND (black)
Authentication Success
(orange with black stripes)
Authentication Error (orange)
DATA1 (white)
DATA0 (green)
POWER
CONTROLLER
14_ installation and external connection
installation and external connection
CONNECTING TO THE EXTERNAL READER
External Reader Connection
Connect the DC 12V(+) line of the power supply unit to the plus (+) line of the reader.
Connect the GND(-) line of the power supply unit to the minus (-) line of the reader.
Connect the Wiegand DATA-0 line of the proximity reader to the pink line.
Connect the Wiegand DATA-1 line 1 of the proximity reader to the sky blue line
The product should be connected to GND(-) of the external reader.
For a list of compliant readers (external readers), see the followings:
SSA-R2010/SSA-R2020/SSA-R2040
- Standard 26bit Wiegand format proximity reader
SSA-R2011 / SSA-R2021 / SSA-R2041
- Standard 34bit Wiegand format proximity reader
1.
2.
3.
4.
5.
CONTROLLER
POWER
Reader
DATA-0 (pink)
DATA-1 (sky blue)
DC12V (red)
GND (black)
OK Signal Out
Wiegand D0
Wiegand D1
Error Signal Out
Power Supply Unit
GND
(-)
DC12V
(+)
Englis_ English _ 15
INSTALLATION AND EXTERNAL CONNECTION
TCP/IP Communication Port Connection
To enable TCP/IP communications with the host PC, you must have connected the RJ45 jack to CON4 (8-PIN
connector). Please follow the steps below:
Connect the RJ45 jack of the product to the RJ45 plug of the network system.
Install and launch the application (SAMS).
1.
2.
Hub
RJ45
RJ45 RJ45 RJ45
Host PC
16_ initialization
Initialization
INITIALIZING THE SYSTEM USING THE DIP SWITCH
Initialize the system using the DIP switch on the rear of the product.
Disconnect the power supply.
Position the DIP switch on the rear of the product to ON (upside) and
apply power to the product.
The product sounds a beep once with a voice message, and
proceed with the hardware initialization process.
When the initialization is done, the product sounds a beep three times
with a completion message output.
The product keeps sounding the beep until you change the
communication address.
Use the DIP switch to specify the BOARD ID.
Refer to “Communication Address Setup”. (on page 22)
You must specify the communication address and register the
master ID.
If you initialize the hardware system, all data settings return to the factory default.
(including IDs, fi ngerprint data, master ID, card number output format, IP)
If you initialize the system using SAMS, all data except for the IP setting will return to the default.
If the communication address is set to 255, the initialization process gets started immediately.
1.
2.
3.
4.
5.
6.
J
ON KSD82H
12 654873
QWELCOME TO ACCESS
CONTROL SYSTEM
ON KSD82H
12 654873
QSYSTEM
INITIALIZING
Englis_ English _ 17
INITIALIZATION
DISPLAY AND OPERATION STATUS OF READER/REGISTER
LED ON : LED OFF : LED Blinking :
LED Beep Voice Message Description
PWR OK ERR
1 BEEP WELCOME TO ACCESS
CONTROL SYSTEM
The product is in the boot process after it
turned on.
PWR OK ERR
X SYSTEM INITIALIZED Restores registered user cards and other
system settings to the default.
REGISTRATION MODE
LED Beep Voice Message Description
PWR OK ERR
X MASTER ID REGISTRATION MODE
The fi rst card read by the product after it is
Initialized will be registered as the master
card.
PWR OK ERR
XREGISTRATION AND DELETION MODE,
SCAN YOUR CARD You can register or remove the user card.
PWR OK ERR
3 BEEPS ID REGISTERED The user card is registered successfully.
PWR OK ERR
3 BEEPS FINGERPRINT REGISTERED The user card/fi ngerprint is registered
successfully.
PWR OK ERR
2 BEEPS FINGERPRINT REGISTRATION
FAILED, PLEASE TRY AGAIN Failed to register the user card/fi ngerprint.
PWR OK ERR
4 BEEPS ID DELETED The user card/fi ngerprint is deleted
successfully.
READER MODE
LED Beep Voice Message Description
PWR OK ERR
X READER MODE
User card will be authenticated in normal
operation mode
PWR OK ERR
1 BEEP ACCESS GRANTED User access is granted
PWR OK ERR
2 BEEPS ACCESS DENIED,
PLEASE TRY AGAIN User access is denied
PWR OK ERR
2 BEEPS ID UNREGISTERED Unregistered user
LED ON :
PWR OK ERR
LED Blinking :
PWR OK ERR
PWR OK ERR
PWR OK ERR
PWR OK ERR
PWR OK ERR
PWR OK ERR
PWR OK ERR
PWR OK ERR
PWR OK ERR
PWR OK ERR
PWR OK ERR
18_ initialization
initialization
TO REGISTER/DELETE THE MASTER ID (CARD)
The product will switch to Registration mode when presented with the master card in Reader mode.
The product will switch to Reader mode when presented with the master card in Registration mode.
If you want to register a new master card, initialize the system before proceeding.
Refer to “Initializing the system using the DIP switch”. (on page 20)
When the initialization is completed, the product outputs a voice
message with the green and orange indicators turned on, then
present the master card.
When you present the card to the product (beep once when it is
read), it will beep three times with a voice message output.
The blinking green and orange indicators indicate that the
product switches to Master mode.
Then, register normal users if you want to.
To exit Master mode, present the master card to the product again.
You will hear the following voice message:
When the green and orange indicators are all turned off, the
product is in Reader mode.
For the master card, no fi ngerprint registration is required.
COMMUNICATION ADDRESS SETUP
You can upload or download the user fi ngerprint using SAMS. You can also change the settings of the product to apply to
different situations.
The Board ID is a device address based on which the SW application recognizes the device. For this purpose, the Board
ID should be unique.
You can specify up to 255 different BOARD IDs from “000” to “254”.
Use the DIP switch on the rear panel to specify the BOARD ID.
The DIP switch on the rear panel is assigned in binary code respectively, starting from the leftmost. In other
words, the fi rst DIP switch has the value of “1”, the second one with “2”, and the third is “4”. According to this
way of calculation, the eighth switch has the value of “128”.
Move down the DIP switch to OFF, and move it up to the corresponding value.
The value of the board ID is the sum of all values of the DIP switches whose positions are upward. For instance,
if the fi rst, third, fourth, seventh and eighth DIP switches are positioned upward, the board ID will be “205”.
The default address is set to “000”.
For serial communication, each product in the same loop should have a unique communication address.
The default baud rate is set to 57600 bps.
1.
2.
3.
4.
5.
M
1.
2.
3.
M
QWELCOME TO ACCESS
CONTROL SYSTEM
QMASTER ID
REGISTRATION MODE
QREGISTRATION AND
DELETION MODE, SCAN
YOUR CARD
QREADER MODE
Englis_ English _ 19
INITIALIZATION
READER MODE AND AUTHENTICATION
Reader Mode
In Reader mode, any recognized user ID or status will be transmitted to the controller.
If the user ID and fi ngerprint are authenticated, the corresponding card ID will be displayed.
If they are not authenticated, an error signal will be output.
How to get authenticated if set to RF Only mode or if registered in RF
Only mode
Present the registered card to the reader.
When the card is authenticated successfully, you will hear a long beep with the green indicator turned on.
The user ID will be displayed according to the specifi ed output format.
How to get authenticated if set to RF+ Finger mode and registered in
RF+ Finger mode
Present the registered card to the reader.
When the card is recognized, the red lamp on the scanner turns on.
Place the registered fi ngerprint on the scanner.
When the fi ngerprint is authenticated successfully, you will hear a long beep with the green indicator turned on,
and the user ID will be displayed according to the specifi ed output format.
If the fi ngerprint is denied, you will hear a beep twice with the orage indicator blinking twice, and the fi ngerprint
error signal (Low Active) will be output for 500ms.
If the card is not registered
If you will hear a beep twice with the orange indicator blinking twice when presenting the card to the reader, this
indicates that the card is unregistered or already deleted.
For an unregistered card or denied fi ngerprint, the reader will output the fi ngerprint error signal (Low Active) for
500ms.
1.
2.
3.
1.
2.
3.
1.
2.
3.
4.
5.
1.
2.
20_ user management
User Management
REGISTERING THE ID
Check if the green and orange indicators are all turned off when the reader turns on.
Present the master card to the reader. You will hear the following
voice message with the green and orange indicators blinking.
Present a user card to the reader. (You will hear a beep once when
the card is read) if you want to register the card alone, do not register
the fi ngerprint yet and just wait after a voice message of “PUT YOUR
FINGER”.
You will hear a voice message of “ID Registered” with a beep three
times before registration of the card ID is completed .
Repeat step 3 above if you want to register another user.
When the user registration is completed, present the master card to exit the registration mode.
TO REGISTER THE ID CARD ALONG WITH THE FINGERPRINT
Check if the green and orange indicators are all turned off when the reader turns on.
Present the master card to the reader. You will hear the following
voice message with the green and orange indicators blinking.
Present a user card to the reader. Upon the voice message of “PUT
YOUR FINGER”, Place the fi ngerprint on the scanner.
Upon the voice message of “REMOVED FINGER”, release the
ngerprint from the scanner; present the fi ngerprint on the scanner
again when hearing “PUT YOUR FINGER AGAIN”.
The user registration is completed when you hear the corresponding
message with a beep twice.
Repeat steps 3 through 5 above if you want to register another user.
When the user registration is completed, present the master card to exit
the registration mode.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
6.
7.
QREGISTRATION AND
DELETION MODE, SCAN
YOUR CARD
QPUT YOUR FINGER
QID REGISTERED
QREGISTRATION AND
DELETION MODE, SCAN
YOUR CARD
QPUT YOUR FINGER
QREMOVED FINGER
QPUT YOUR FINGER AGAIN
QFINGERPRINT REGISTERED
Englis_ English _ 21
USER MANAGEMENT
TO DELETE ID
Check if the green and orange indicators are all turned off when the reader turns on.
Present the master card to the reader. You will hear the following
voice message with the green and orange indicators blinking.
Present a registered user card to the reader. When you hear the
following message with a beep four times, the user is deleted
successfully.
When the ID is deleted, the fi ngerprint data will be deleted too.
Repeat step 3 above if you want to delete another user.
When the ID deletion is completed, present the master card to exit the registration mode.
1.
2.
3.
4.
5.
QREGISTRATION AND
DELETION MODE, SCAN
YOUR CARD
QID DELETED
22_ output format
Output Format
WIEGAND OUTPUT (DEFAULT)
Timing Diagram
Data Type (26-bit /34-bit)
Even parity bits from Bit 2 to Bit 13 / Bit 2 to Bit 17
Bit 2 to Bit25 / Bit 2 to Bit33 : 3-byte ID number / 4-byte ID number
Bit 26 / Bit 34 : Odd parity bits from Bit 14 to Bit 25 / Bit 18 to Bit 33
100us
1ms
DATA-0
DATA-1
LOGIC
1
0
2
1
3
1
n*n : 34 or 26
0
n-2
1
n-1
5V
0V
5V
0V
0
Englis_ English _ 23
OTHER INFORMATION
Other Information
HOW TO REGISTER THE FINGERPRINT
Correct Fingerprint Registration
Incorrect Fingerprint Registration
In case of failures of fi ngerprint recognition
Moist Fingerprint
Dry Fingerprint
Stained Fingerprint
Scarred Fingerprint
How to manage fi ngerprints
Follow the instructions below to increase the rate of successful authentication of the fi ngerprint.
For a dry fi ngerprint, put force to present the fi ngerprint to the scanner.
For a moist fi ngerprint, gently present the fi ngerprint to the scanner.
Keep the fi ngerprint scanner clean all the time, especially on the surface.
{
Fingerprint
scanning
Successful 1:1/1:N
Authentication
Fingerprint
Scanning
1:1/1:N Authentication
Error
±
Dry
Fingerprint
Moist
Fingerprint
Stained
Fingerprint
24_ troubleshooting
troubleshooting
TROUBLESHOOTING
If the product does not function properly, please see the below for trouble shooting. If the trouble persists, please contact
the SAMSUNG Customer Service near you.
Problem Action
If you fail to enter registration mode using
the master card
1) Check if the master card is invalid.
Change the master card using software communications, and try to access
using the changed card.
2) Refer to the user manual and initialize the hardware. (before system
installation)
* Note that all existing settings will return to the factory default.
(card deleted/system initialized/master card deleted, etc)
3) If the problem persists, contact the nearest customer service for technical
help.
Fingerprint registration or authentication
do not work well.
1) Please check the correct fi ngerprint registration instruction in the user
manual and try again.
Proper
ngerprint
position
Improperly positioned fi ngerprints
2) Check the state of the fi ngerprint.
Normal
ngerprint
Dry
Fingerprint
Moist
Fingerprint
Too gentle
pressure
Too string
pressure
3) Adaptive mode will correct excessively dry or moist fi ngerprints as necessary
when sensing them. It may take longer to sense the fi ngerprint in this mode,
but the fi ngerprint recognition rate will be increased. You can confi gure the
Adaptive settings using the software.
Englis_ English _ 25
product specifi cations
PRODUCT SPECIFICATIONS
Item SSA-
R2010
SSA-
R2020
SSA-
R2040
SSA-
R2011
SSA-
R2021
SSA-
R2041
Fingerprint Users 1,000 2,000 4,000 1,000 2,000 4,000
Fingerprint Templates Size 800Bytes for 2 Fingerprint Templates
Power / Current DC 12V / Max.290mA DC 12V / Max.310mA
Reader Port External Reader Port 1ea : 26bit
Wiegand
External Reader Port 1ea : 34bit
Wiegand
Reading Time (Card) 30ms
Verifi cation Time Less than 1sec.
Identifi cation Time Less than 2sec.
Communication TCP/IP
Baud Rate(bps) 57,600
Input Port 3 EA (External LED Control, External Buzzer Control,
Operating Mode(RF/ RF+ Finger) Control)
Output Port
2EA (Error- Output, OK-Output(Open Collector Output))
26bit Wiegand 34bit Wiegand
LED Indicator 3 LED Indicators (Red, Green and Orange)
Beeper Piezo Buzzer
Voice Output (Language) English
Operating Temperature 0°C to +50°C
Operating Humidity 10% to 90% relative humidity non-condensing
Color / Material Silver with Black / Polycarbonate
Dimension (W x H x D(mm)) 65.0 x 128.0 x 48.5
Weight 240g 230g
RF Specifi cations
Frequency 125KHz 125KHz 125KHz
13.5610 MHz 13.5610 MHz 13.5610 MHz
Modulation PSK PSK PSK ASK ASK ASK
No. of Channels
1CH 1CH 1CH 1CH 1CH 1CH
Output
Less than
65.80dBuA/m
at a distance of
10m
Less than
65.80dBuA/m
at a distance of
10m
Less than
65.80dBuA/m
at a distance of
10m
Less than
47.544 mV/m
at a distance of
10m
Less than
47.544 mV/m
at a distance of
10m
Less than
47.544 mV/m
at a distance of
10m
AB82-02555A
Correct disposal of batteries in this product
(Applicable in the European Union and other European countries with separate battery return systems.)
This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of
with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate
that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. If batteries are
not properly disposed of, these substances can cause harm to human health or the environment.
To protect natural resources and to promote material reuse, please separate batteries from other types of waste and
recycle them through your local, free battery return system.
Correct Disposal of This Product (Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g.
charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To
prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these
items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for
details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract.
This product and its electronic accessories should not be mixed with other commercial wastes for disposal.

Navigation menu