Samsung Electronics Co WEA504I WLAN Access Point User Manual

Samsung Electronics Co Ltd WLAN Access Point Users Manual

Users Manual

Names and FunctionsFront View Rear View Ethernet Port DC InputEthernet Port (PoE)Factory Reset SwitchConsole PortDust covers are installed on power ports (DC 48 V/0.75 A), Ethernet ports and console ports (CONSOLE). Remove the covers before use.InterfacePort Name DescriptionStatus LED  Displays the status information of the WEA400/500 Series via LED.DC Input Used when a power adapter is used for power supply.Ethernet Port (PoE) Supports 1000 BASE-T Gigabit Ethernet and PoE IEEE 802.3af/802.3at.Ethernet Port Supports 1000 BASE-T Gigabit Ethernet.Console Port  Used for checking the operational status of the WEA400/500 series and for CLI input.Factory Reset SwitchUsed for initialization when commencing factory shipment of the WEA400/500 series.Status LED Introduction What is the WEA400/500 series?The WEA400/500 is a series of APs fromthe Samsung WE wireless LAN family. They connect a UE such as a smart phone, a tablet PC or a laptop that supports the wireless LAN to a wired network. The WEA400/500 series supports the following features: - IEEE 802.11a/b/g/n/ac standard- PoE (Power over Ethernet) IEEE 802.3af/802.3at- WEA412i: 2 × 2 MIMO (Multiple Input Multiple Output)- WEA403i/403e/413i: 3 × 3 MIMO (Multiple Input Multiple Output)- WEA504i/514i: 4 × 4 MU-MIMO (Multi User-Multiple Input Multiple Output)- Wireless LAN through both 2.4 GHz and 5 GHz bandwidth simultaneously- WEA403Si supports the connection of various sensors and equipment to a network with WLAN, BLE, ZigBee.Components After unpacking the WEA400/500 series, check whether all of the following components are included.WEA403i/412i/413i/403Si/504i/514i WEA403eCommon merchandiseMounting Bracket 5 M3 × L6 screws(Including 1 spare) Installation ManualSecurity Torx (T10) Screw Plastic 4 anchors  M4 × L28 4 screws - It is recommended to keep all packaging materials and the box.- The power adapter and the external antenna for WEA403e are sold separately.  When necessary, please contact the place of purchase.This manual describes the configuration of the Wireless Enterprise WEA400/500 series and  its installation procedures.The installation procedures are described based on the WEA403i/412i/413i/403Si/504i/514i configurations. The same installation procedures apply to the WEA403e model, except for the antenna installation. InstallationThe WEA400/500 series can be installed on ceilings or walls.Please check whether all the components are included before installation.Before Installation Safety RequirementsRisks may be caused when the following safety warnings are not properly observed. For safe use, make sure to be well-informed. - There is an electrical risk with the product. Make sure that the power is off during installation and do not proceed with the installation when there is current leakage. Use of products with current leakage may cause serious electrical shock to the user.- Wear anti-static gloves or take appropriate actions to prevent ESD when handling the product.- This product must be connected to ta power supply in compliance with IEEE 802.3af/at or to a limited power supply in compliance with IEC/EN/UL 60950-1.- This product must be installed or removed only by appropriately-trained service personnel.- This product operates with SELV (Safety Extra Low Voltage) according to IEC/EN/UL 60950-1.- All interconnecting equipment including this product must be installed within the same building. For details, refer to Environment A of IEEE 802.3af/at standard.- This product must be installed with at least 3 m or more distance from the WiMAX/3G/4G repeater or antenna.Installation InstructionsThe instructions below must be followed when installing. - It must be installed in a place that can be easily accessed for product installation, cable connection and maintenance.- The PoE LAN cable must be always installed away from any electrical interference source such as power lines, fluorescent lights or transmitters.- The PoE LAN cable must be CAT 5E or higher.- When PoE is unavailable, a power adapter (sold separately) can be used. The 3-pin (including ground) power socket that supplies 100~240 V AC, 50~60 Hz must be located within 2 m from each equipment and the power must be supplied through an independent circuit breaker. It is recommended to use the equipment that uses a filter or a surge. Installation on Ceilings (When the ceiling type is T-bar)- When incorrectly installed on the ceiling, the WEA400/500 series may drop onto a person or equipment. Therefore, make sure to fix it firmly.- If the ceiling type is not T-Bar, please refer to the ‘Installation Manual’ provided separately. For this installation manual, please contact the dealer. 1.  Remove the holding tape that was attached to fix the ceiling clip.Holding tape2.  Open the ceiling clip so that it is wider than the width of the T-bar. 3.  Move the ceiling clip so that it is appropriate for the T-bar width.Status LEDLED Status  Description System start statusWhite On  Initial LED status Blue On  Device reset and test in progressRed On  Booting failure (Device reset failure) Provisioning StatusRed, green and off repeatedAPC connection in progress(Network link normal) Green blinking  CAPWAP connection in progress(APC server connection normal) Normal operation statusGreen On  When there is no connected wireless UE Blue On  When there is a connected wireless UEUpgrade  Green blinking  Software upgrade in progressError status  Red blinking  Physical connection error of network Yellow blinking  IP address conflict Purple blinking  Dynamic IP address allocation failure Bluish-green blinking  Logical connection error of network Red, green and off repeatedWireless interface error WEA400/500 Series (Indoor) Quick Installation Manual
5. Insert a LAN cable into the Ethernet port (PoE) onthe back side of the WEA400/500 series.If PoE is not supported, connect the power adapter to the DC input on the back of the WEA400/500 series.The wall For the WEA403e model, remove the protection cap from the antenna connector and install the external antenna (separately purchased). The 3 types of antennas that can be installed to the WEA403e model are listed below. (More antenna types may be added in the future.) Low gain dipole antenna Patch antennaHigh gain dipole antennaInstalling Anti-Theft Lock CableWhen installing the WEA400/500 series AP in a public place, it is recommended to use anti- theft lock cables to prevent any loss. (An anti-theft lock cable can be purchased separately and a variety of products can be found in the market.)1.  Connect the anti-theft lock cable to the WEA400/500 series AP.or2.  Turn the lock cable key to lock the cable.3.  Remove the key from the lock cable and keep it in a separate location.Using the anti-theft Torx screwsThe WEA400/500 series AP products can be prevented from being stolen when tightening the Torx screws as shown below. (Torx screws can be easily tightening when they are fixed to the mount bracket before assembling the AP product.)This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna.- Increase the separation between the equipment and receiver.- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.- Consult the dealer or an experienced radio/TV technician for help.Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.The 5150-5250 MHz band is restricted to indoor use only.This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device  may not cause interference, and (2) this devicemust accept any interference, including interference that may cause undesired operation of thedevice.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.  L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with a minimum distance of 50 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.RSS-102 RF ExposureL’antenne (ou les antennes) doit être installée de façon à maintenir à tout instant une distance minimum de au moins 50 cm ntre la source de radiation (l’antenne) et toute personne physique. Cet appareil ne doit pas être installé ou utilisé en conjonction avec une autre antenne ou émetteur. Should the access point be installed in a ceiling with ventilation, the AP ETHERNET PORT must be horizontally placed.Class B Equipment (For Home Use Broadcasting & Communication Equipment)This equipment is home use (Class B) electromagnetic wave suitability equipment and to be used mainly at home and it can be used in all areas.Electromagnetic Wave Suitability NoticeRegulatory Information‘Hereby, Samsung Electronics, declares that this WEA400/500 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.’The original Declaration of Conformity may be found at http://www.samsungdocs.com, go to Search Product and enter the model name.AEEE Yönetmeliğine Uygundur (Compliant with WEEE) 产品中有害物质的名称及含量部件名称有害物質铅(Pb)汞 (Hg)镉(Cd)六价铬(Cr6+)多溴联苯 (PBB)多溴二苯醚 (PBDE)金屬 料件 ×○○○○○印刷电路板部件 ×○○○○○線材 ×○○○○○塑膠件  ○○○○○○本表格依据SJ/T11364的规定编制○: 表示该有害物质在该部件所有均质材料中的含量均在GB/T26572规定的限量要求以下。×: 表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T26572规定的限量要求。本表格提供的信息是基于供应商提供的数据及三星公司的检测结果。在当前技术水平下、所有有毒有害物质或元素的使用控 制到了最底线。三星公司会继续努力通过改善技术来减少这些物质和元素的使用。http://www.samsungenterprise.comPart No.: EC00-00000A (Ver.1.0)4. Fix the ceiling clip in place bytightening the 4 designated screws.Screws for fixing the ceiling clip5. Fix the T-bar in place by fasteningthe screws (total of 2) that are onthe ceiling clip.Screws for  fixing T-barIf the T-bar size of the ceiling is 15 mm, 24 mm or 38 mm, the position to fix the ceiling clip can be checked from the bottom surface of the mount bracket. If the T-bar size is unknown, push the ceiling clip to check the fixing positions.6. Pull out a LAN cable through a hole onthe ceiling and connect is to an Ethernetport (PoE) on the back side of theWEA400/500 series.Exterior of the ceilingIf PoE is not supported, connect the power adapter to the DC input on the back side of the WEA400/500 series. The output of the power adapter is 48 V/0.75 A and is not compatible with the 12 V/2 A output power adapter that is used by the previous WEA302i/303i/303e AP.7. Align the WEA400/500 series withthe 3 holes on the mount bracketand then turn clockwise to fix itin place. Clean up the ceiling andother cables.Interior of the ceilingInstallation on Walls1. Remove the holding tape that wasattached to fix the ceiling clip.Holding tape2. Remove the ceiling clip from the mount bracket.3. Place the mount bracket on the wall.Mark and drill 4 screws in appropriate spots.4. Use a hammer to insert4 plastic anchors into thedrilled holes on the wall.Align the inserted plasticanchors and the screwholes of the bracket.Fix the bracket to the wallby fastening four M4 × L28screws.IC Information to User“This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.” Cet appareil est conforme avec Industrie Canada RSS standard exempts de licence(s), Son utilisation est soumise à Les deux conditions suivantes: (1) cet appareil ne peut pas provoquer d’interférences et (2) cet appareil doit accepter Toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.

Navigation menu