overview
CAUTION
RISK OF ELECTRIC SHOCK.
DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
This symbol indicates that dangerous voltage consisting a risk of
electric shock is present within this unit.
This symbol indicates that there are important operating and
maintenance instructions in the literature accompanying this unit.

WARNING
 To reduce the risk of fire or electric shock, do not expose this appliance to rain or
moisture.
 To prevent injury, this apparatus must be securely attached to the floor/wall in
accordance with the installation instructions.
 Use only the 24V, 60Hz AC adaptor for power supply.

WARNING
1. Be sure to use only the standard adapter that is specified in the specification sheet.
Using any other adapter could cause fire, electrical shock, or damage to the
product.
2. Incorrectly connecting the power supply or replacing battery may cause explosion,
fire, electric shock, or damage to the product.
3. Do not connect multiple cameras to a single adapter. Exceeding the capacity may
cause abnormal heat generation or fire.
4. Securely plug the power cord into the power receptacle. Insecure connection may
cause fire.
5. When installing the camera, fasten it securely and firmly. The fall of camera may
cause personal injury.

_ overview

00956B-NA_SCC-C7453N-ENG.indb 2

2009-08-13 오후 10:58:

6. Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or
containers filled with water on top of the camera. Doing so may cause personal
injury due to fire, electric shock, or falling objects.

8. If any unusual smells or smoke come from the unit, stop using the product. In such
case, immediately disconnect the power source and contact the service center.
Continued use in such a condition may cause fire or electric shock.

English

7. Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fire
or electric shock.

9. If this product fails to operate normally, contact the nearest service center. Never
disassemble or modify this product in any way. (SAMSUNG is not liable for
problems caused by unauthorized modifications or attempted repair.)
10. When cleaning, do not spray water directly onto parts of the product. Doing so may
cause fire or electric shock
11. Do not expose the product to the direct airflow from an air conditioner.
Otherwise, it may cause moisture condensation inside the Clear Dome due to
temperature difference between internal and external of the dome camera.
12. If you install this product in a low-temp area such as inside a cold store, you must
seal up the wiring pipe with silicon, so that the external air can not flow inside the
housing.
Otherwise, external high, humid air may flow inside the housing, pooling moisture
or vapor inside the product due to a difference between internal and external
temperature.

00956B-NA_SCC-C7453N-ENG.indb 3

English _

2009-08-13 오후 10:58:

overview
CAUTION
1. Do not drop objects on the product or apply strong blows to it. Keep away from a
location subject to excessive vibration or magnetic interference.
2. Do not install in a location subject to high temperature (over 50°C), low temperature
(below -50°C), or high humidity. Doing so may cause fire or electric shock.
3. If you want to relocate the already installed product, be sure to turn off the power
and then move or reinstall it.
4. Remove the power plug from the outlet when there is a lighting storm. Neglecting
to do so may cause fire or damage to the product.
5. Keep out of direct sunlight and heat radiation sources. It may cause fire.
6. Install it in a place with good ventilation.
7. Avoid aiming the camera directly towards extremely bright objects such as sun, as
this may damage the CCD image sensor.
8. Apparatus shall not be exposed to dripping or splashing and no objects filled with
liquids, such as vases, shall be placed on the apparatus.
9. The Mains plug is used as a disconnect device and shall stay readily operable at
any time.
10. When using the camera outdoors, moisture may occur inside the camera due
to temperature difference between indoors and outdoors. For this reason, it is
recommended to install the camera indoors. For outdoor use, use the camera with
built-in fan and heater.

_ overview

00956B-NA_SCC-C7453N-ENG.indb 4

2009-08-13 오후 10:58:

FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions :
2) This device must accept any interference received including interference that may
cause undesired operation.

English

1) This device may not cause harmful interference, and

Caution
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated
in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.

IC Compliance Notice
This Class A digital apparatus meets all requirements of the Canadian
Interference.-Causing Equipment Regulations of ICES-003.

00956B-NA_SCC-C7453N-ENG.indb 5

English _

2009-08-13 오후 10:58:

overview
important safety instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such as radiators, heat registers, or other
apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug.
A polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wide blade or the third prong
is provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified
by the manufacturer, or sold with the apparatus. When a
cart is used, use caution when moving the cart/apparatus
combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused
for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as powersupply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
Apparatus shall not be exposed to dripping or splashing and no objects
filled with liquids, such as vases, shall be placed on the apparatus

_ overview

00956B-NA_SCC-C7453N-ENG.indb 6

2009-08-13 오후 10:58:

contents
overview

Important Safety Instructions
Contents
Features
What’s Included
At a Glance

installation &
connection

10	

10

12	
12	
13	
16	
19	

Optional Accessories for
Installation
Precautions
Preparation
Installation
Initial Setup
Connecting with other Device

setup

22	

2

00956B-NA_SCC-C7453N-ENG.indb 7

22

appendix

50

23	
24	
26	
35	
36	
37	
39	
43	
44	
46	
46	
48	
48	
49	

How to use the Keyboard
Controller
Main Menu
Profile
Camera Set
Intelligent Video
Privacy Zone
Preset
Auto Set
Zone Set
Alarm Set
Clock Set
Other Set
Communication
System Info
Language

50	
51	
53	

Shortcut Keys
Specifications
Product Appearance

English

6	
7	
8	
8	
9	

English _

2009-08-13 오후 10:58:

overview
Features
 With the state-of-the-art digital signal processing technology, full digital image
processing and special algorithm of 600-line high resolution implemented
 High performance surveillance camera, equipped with x43 zoom lens and digital
zoom IC, enabling monitoring up to 688 times
 DAY/NIGHT to improve the sensitivity by automatic conversion into the black and
white mode at night or in the environment with low illumination
 White Balance to control the brightness to the illumination
 Backlight Compensation under spotlight or utmost bright illumination
 Auto Focus to automatically adjust the focus to the subject movement
 Privacy zone to hide a specific area for personal privacy
 PAN/TILT for precise control at high speed

What’s Included
Please check if your camera and accessories are all included in the product package.

Camera

Housing

Connectors

Grease

Pin & Bush

User Manual

User Manual

_ overview

00956B-NA_SCC-C7453N-ENG.indb 8

2009-08-13 오후 10:58:

At a Glance
CAMERA
English

HOOK

HOOK

LENS

FRAME SET

RS-485
ALARM IN
POWER
INPUT
ALARM OUT

M

 Wipe out a dirty surface of the lens softly with a lens tissue or cloth to which you
have applied ethanol.

00956B-NA_SCC-C7453N-ENG.indb 9

English _

2009-08-13 오후 10:58:

installation & connection
Optional Accessories for Installation
For your easier installation, you can purchase appropriate optional accessories available.
1. WALL MOUNT ADAPTOR (SCX-300WM)
This is a wall mount adaptor, used for wallmounted installation of SMART DOME
CAMEA units.

2. CEILING MOUNT ADAPTOR (SCX-300CM)
This is a ceiling mount adaptor, used for
installation of SMART DOME CAMEA units on
a concrete ceiling.

3. POLE MOUNT ADAPTOR (SCX-300PM)
This is an adaptor for WALL MOUNT
ADAPTOR (SCX-300WM) installation on a
pole whose diameter is bigger than 80mm.

10_ installation & connection

00956B-NA_SCC-C7453N-ENG.indb 10

2009-08-13 오후 10:58:

4. CORNER MOUNT ADAPTOR (SCX-300KM)
This is an adaptor for WALL MOUNT
ADAPTOR (SCX-300WM) installation on the
corner of wall joint.

English

5. PARAPET (LONG) MOUNT (SCX-300LM)
This is a mounting kit used for installation of
SMART DOME CAMEA units on a parapet.

00956B-NA_SCC-C7453N-ENG.indb 11

English _11

2009-08-13 오후 10:58:

installation & connection
PRECAUTIONS
1. Select an installation spot which can endure more than 4 times of the product
weight.
2. When installing, prevent peoples approaching to avoid personal injury.
Move valuables to a safer place before installing.

Preparation
Run all the external cables through the bracket adaptor’s PIPE or MOUNT hole.
Wrap around the HOUSING’s screw hole with the Teflon Tape.
1.5" PT
PIPE OR
MOUNT

HOUSING

TEFLON TAPE

1.5" PT
EXTERNAL
CABLE

12_ installation & connection

00956B-NA_SCC-C7453N-ENG.indb 12

2009-08-13 오후 10:58:

Installation

PIPE OR
MOUNT

English

1. Press the SNAP FIT of the ADAPTOR in the HOUSING to open the ADAPTOR
part, and then insert all external cables into the HOUSING. Secure the HOUSING
on the PIPE or MOUNT by turning it clockwise.
(Secure two components tightly, to avoid loosened HOUSING.)
PIPE OR
MOUNT

HOUSING

HOUSING

EXTERNAL
CABLE
ADAPTOR
SNAP-FIT
2. Connect external cables to the CONNECTORS(ALARM IN, POWER, RS-485,
ALARM OUT) and connect the CONNECTOR to the ADAPTOR.
Insert the cable into the FRAME SET, and close the ADAPTOR.

BNC JACK

HOUSING

INSULATION
TUBE

POWER INPUT ALARM OUT
ALARM IN

RS-485

EXTERNAL
CABLE
ADAPTOR

M

 Then, wrap the BNC JACK with the INSULATION TUBE, and use an insulation tape
to seal up the end of the INSULATION TUBE so that the BNC JACK does not
protrude outside of the INSULATION TUBE coating.
For more information about cable connection, refer to Connecting the adaptor
cable. (page 21)

00956B-NA_SCC-C7453N-ENG.indb 13

English _13

2009-08-13 오후 10:58:

installation & connection
Note that BUSHINGs are provided for outdoor installations where exposed to a
moisture condition through the PIPE or MOUNT, install the HOUSING using the
BUSHING to prevent moisture entering.
- Apply grease of proper dose on the BUSHING before assembling, and run
cables through each hole of the bushings. Use PINS to stop up empty holes
having no cable running.
- Assemble the BUSHING to the top side of HOUSING’s inside as shown in the
diagram below. At the moment, apply pressure evenly on the BUSHING to
secure it tightly to the HOUSING as shown in the diagram.
POWER
(24V) CABLE

BUSH

BNC CABLE

ETC CABLE

BUSH

PIN
BUSH



BUSH

BUSH
HOUSING

PIPE OR
MOUNT

HOUSING
BUSH

14_ installation & connection

00956B-NA_SCC-C7453N-ENG.indb 14

2009-08-13 오후 10:58:

22P CONNECTOR

HOUSING

RACK

RACK

BRACKET WIRE
FRAME SET
SAFETY WIRE
HOOK

PROTECTIVE
TAPE
PROTECTIVE
COVER

CAMERA

HOOK

M

English

3. Tie up the SAFETY WIRE of the CAMERA on the BRACKET WIRE of the FRAME
SET.
Arrange the 22P CONNECTOR of the CAMERA in line with that of the ADAPTOR,
push the HOOKs on either end of the CAMERA in the RACK direction of the
FRAME SET to secure the two.
Then, ensure that all of the two HOOKs clicks to fix to the RACK properly.

 When the installation is completed, remove the PROTECTIVE COVER and
PRETOECTIVE TAPE from the lens.

4. Align each of the 3 SCREWS of COVER DOME and 3 SCREW HOLEs of the
HOUSING respectively, and assemble the COVER DOME and HOUSING. During
the assembling, note on the followings.
 Insert and arrange SAFETY WIRE into the HOUSING while not disturbing the
camera operation.
 Ensure that the GASKET DOME component does not separate from the
COVER DOME. (If the GASKET DOME is not properly assembled, it damages
the waterproofness.)

SAFETY WIRE
HOUSING

HOUSING
SCREWS

CAMERA
COVER DOME
GASKET DOME

00956B-NA_SCC-C7453N-ENG.indb 15

COVER DOME

English _15

2009-08-13 오후 10:58:

installation & connection
INITIAL SETUP
Camera Address Setup
Use SW606, SW605, and SW604 to specify the camera address.
You can specify between 0 and 255 for the address, where the hundreds digit is
with SW606, the tens digit with SW605, and the ones digit with SW604.
ex) Camera address: If the address is 1, follow the steps in the figure below.

SW606
(x100)

SW605
(x10)

SW604
(x1)

Communication Protocol Setup
Use pins #1~#4 of SW603 to specify the communication protocol.
PIN
Comp
A

PIN1

PIN2

PIN3

PIN4

OFF

OFF

OFF

OFF

B

ON

OFF

OFF

OFF

C

OFF

ON

OFF

OFF

D

ON

ON

OFF

OFF

E

OFF

OFF

ON

OFF

F

ON

OFF

ON

OFF

G

OFF

ON

ON

OFF

H

ON

ON

ON

OFF

I

OFF

OFF

OFF

ON

J

ON

OFF

OFF

ON

K

OFF

ON

OFF

ON

L

ON

ON

OFF

ON

M

OFF

OFF

ON

ON

N

ON

OFF

ON

ON

O

OFF

ON

ON

ON

P

ON

ON

ON

ON

A : SAMSUNG HALF
B : SAMSUNG FULL



1_ installation & connection

00956B-NA_SCC-C7453N-ENG.indb 16

2009-08-13 오후 10:58:

Baud Rate Setup
Use pins #5, #6 of SW603 to set the baud rate.

English

BAUD RATE

PIN 5

PIN 6

4800 BPS

ON

ON

9600 BPS

OFF

ON

19200 BPS

ON

OFF

38400 BPS

OFF

OFF

The factory default is 9600 BPS.

Setting RS-422A/RS-485 Termination

As it is shown in the structure map, when Controller and RS-422A/RS-485 is
connected, it should be terminated according to the Cable feature of impedance
on the each end of the transmitting line to transfer the signals in long distance by
controlling the reflection of the signals to the lowest.
n < 32

Termination
Controller

TX+(DATA+)
TX-(DATA-)
RX+

RX-

CAM 1

RX+

RX-

CAM 2

RX+

RX-

CAM n-1

RX-

Termination
SW1-ON
RX+

CAM n


Termination : Using numbers 1 and 2 PIN, turn to  and it will be terminated.

00956B-NA_SCC-C7453N-ENG.indb 17

English _17

2009-08-13 오후 10:58:

installation & connection
n < 32
Termination
SW1-ON
SW2-ON

Controller
Termination
CAM 1

CAM 2

CAM n-1

CAM n



M

 A communication error may occur if you connect multiple cameras that are assigned
the same address in the network.

18_ installation & connection

00956B-NA_SCC-C7453N-ENG.indb 18

2009-08-13 오후 10:58:

Connecting WITH OTHER device
English

MONITOR

CONTROLLER/DVR
ALARM IN

POWER SOURCE

ALARM OUT

Connecting to a monitor
1. Connect one end of the BNC
video cable connector to the
Video Output Terminal (VIDEO
OUT).
2. Connect the other end of the
connector to the Video Input
Terminal of the monitor.

00956B-NA_SCC-C7453N-ENG.indb 19

Video terminal on the
rear of monitor

BNC Cable

English _19

2009-08-13 오후 10:58:

installation & connection
To connect ALARM IN
1. Connect one end of the external device's signal line to a corresponding ALARM
IN port of the monitor.
2. Connect the other end of the signal line to the earth-grounding [GND] port.

To connect ALARM OUT
1. Connect one end of the external device's signal line to a corresponding ALARM
OUT port of the monitor.
2. Connect the other end of the signal line to the common [COM] port.

To connect the controller
Connect an external controller or DVR to the camera, with which you can adjust the
camera.
1. Connect the Rx+ pin of the
camera to the Tx+ pin of the
controller.
2. Connect the Rx- pin of the
camera to the Tx- pin of the
controller.

Rx

Tx

3. Connect the Tx+ pin of the
camera to the Rx+ pin of the
controller.
4. Connect the Tx- pin of the
camera to the Rx- pin of the
controller.

20_ installation & connection

00956B-NA_SCC-C7453N-ENG.indb 20

2009-08-13 오후 10:58:

Connecting the adaptor cable
Adaptor Board

English

Power Supply
Connect the cables as necessary, and turn on the camera to check if it works
properly.
1. Connect the adaptor to the power terminal of the camera.
2. Plug the power cord of the adaptor into the wall outlet.

00956B-NA_SCC-C7453N-ENG.indb 21

English _21

2009-08-13 오후 10:58:

setup
Connect the camera to the keyboard controller or DVR, with which you
can manipulate and change the settings of the camera.

How to use the keyboard controller
Follow the steps below to set the camera menu using the controller.
1. Open the Camera Setup screen.
2. Use the joystick to navigate through the menus.
3. Press [ENTER] to select a menu item.
4. Use the joystick to change the value of the selected item.
5. Press [ENTER] to apply your changes.

Using OSD icons
 _+: If these icons appear in the left and right corner of a menu item, you can use
the joystick to move to the previous or next menu.


(EXIT): Exits the menu setup screen.
Before exiting the setup screen, select  to save your settings
to the whole menus, or  to cancel them.





(RET): Saves your settings and returns to the previous screen.
(HOME): Returns to the main menu.
(SAVE): Use this icon if you want to save your settings after you specified the
mask area and privacy area, etc.
Once you saved your settings, the changes remain intact even if you
select  on exit.



(DEL): Use this icon if you want to delete a mask, or privacy area, etc.
Once you deleted your settings, the deletions remain valid even if you
select  on exit.



: This icon appears in the right of a menu containing sub menu items.

M

 While any operation of PRESET, AUTO PAN, SCAN, and PATTERN is running, and if
the camera is turned off and back on without any particular manipulation, the
camera will resume the last run operation.

 You can set the menu item only if the tilt angle is within 90°.

If you enter the menu setup screen with the camera positioned out of a tilt of 90°,
the camera will rotate by 180° to fall into the opposite position within a tilt of 90°.

22_ setup

00956B-NA_SCC-C7453N-ENG.indb 22

2009-08-13 오후 10:58:

Main Menu
This is the first screen you ever see when you turn on the camera where you can set the
camera environment to your needs.
 PROFILE
 MAIN MENU 
Select a mode appropriate to the camera
PROFILE
installation environment.
CAMERA SET
INTELLIGENCE
 CAMERA SET
PRIVACY ZONE
PRESET
You can configure the camera settings.
AUTO SET
 INTELLIGENCE
ZONE SET
ALARM SET
Offers motion detection and tracking
CLOCK SET
functions.
OTHER SET
 PRIVACY ZONE
You can configure the privacy settings.
 PRESET
You can set the PRESET POSITION and
COMMUNICATION
DURATION.
SYSTEM INFO
LANGUAGE
 AUTO SET
Contains sub menu items of AUTO PAN,
PATTERN, and SCAN.
 ZONE SET
You can set the standard azimuth and zone
area for the camera.
 ALARM SET
You can set the alarm priority and I/O sequence.
 CLOCK SET
You can set the display time and format.
 OTHER SET
You can reset the camera, or adjust the OSD color to your preference.
 COMMUNICATION
Configures the settings pertaining to RS-485 communication.
 SYSTEM INFO
Shows the system information such as the camera version or communication
settings.
 LANGUAGE
Select a preferred one from the supported languages.

00956B-NA_SCC-C7453N-ENG.indb 23

English

For selecting and saving each menu item, refer to “How to use the keyboard controller”. (page 22)

English _23

2009-08-13 오후 10:58:

setup
PROFILE
You can select one from the pre-determined configurations as appropriate to your
specific camera installation environment.
Your selection on each item in PROFILE will affect all other settings of the camera.
 STANDARD
 PROFILE 
Automatically optimizes the camera settings
STANDARD
to the normal environment.
ITS
 ITS
BACKLIGHT
DAY/NIGHT
This setting enables you to analyze the traffic
GAMING
situation and take the traffic information at a
CUSTOM
glance.
 BACKLIGHT
This setting enables you to view a sharp
background and object even in a severe
backlight scene.
 DAY/NIGHT
Automatically optimizes the camera settings to the day and night scene.
 GAMING
This automatically configures the settings so that you can work in a stable illumination condition as indoors.
 CUSTOM
Your change to any of the PROFILE settings will switch the display to CUSTOM.
CAMERA SETUP MENU
Parent Menu Sub-menus

IRIS

ALC
LEVEL

STANDARD

ITS

BACKLIGHT

DAY/NIGHT

GAMING

ALC

ALC

ALC

ALC

ALC

-

-

-

-

-

0

0

0

0

0
OFF

OFF

OFF

BLC

OFF

MOTION

(F.FAST)
---

(F.FAST)
---

NORM

(F.FAST)
---

SLOW

DNR

MEDIUM

MEDIUM

MEDIUM

MEDIUM

MEDIUM

BACKLIGHT

SHUTTER

OFF

OFF

OFF

OFF

OFF

SENSE UP

AUTO X4

AUTO X2

AUTO X4

AUTO X4

AUTO X4

24_ setup

00956B-NA_SCC-C7453N-ENG.indb 24

2009-08-13 오후 10:58:

CAMERA SETUP MENU
Parent Menu Sub-menus

NIGHT
DAY/NIGHT

BURST
EXT
BURST

DAY

BACKLIGHT

DAY/NIGHT

GAMING

MEDIUM

MEDIUM

MEDIUM

MEDIUM

MEDIUM

AUTO

AUTO

DAY

AUTO

DAY

-

-

-

-

-

OFF

ON

OFF

OFF

OFF

-

-

-

-

-

OFF

ON

OFF

OFF

OFF

DAY

DAY/NIGHT

DAY

DAY/NIGHT

DAY

-

-

-

-

-

ATW2

ATW1

ATW1

ATW1

ATW1

RED

0

0

0

0

0

BLUE

0

0

0

0

0

MODE

WHITE BAL

ITS

-

-

-

-

-

MEDIUM

Custom Setting

MEDIUM

Custom Setting

ATW2

OFF

ATW2

OFF

RED Custom Setting

0

Custom Setting

0

Custom Setting

BLUE Custom Setting

0

Custom Setting

0

Custom Setting

2

2

2

2

NIGHT

BRIGHTNESS Custom Setting
MODE

DETAIL

00956B-NA_SCC-C7453N-ENG.indb 25

OFF

2

English

XDR

STANDARD

English _25

2009-08-13 오후 10:58:

setup
CAMERA SET
You can configure the general settings of the camera module.
For selecting and saving each menu item, refer to “How to use the keyboard controller”. (page 22)

1. Select 
- . The Camera Setup menu appears. 2. Change the settings as necessary, or select an item to check.  CAMERA SET CAMERA ID IRIS MOTION DNR SHUTTER SENS-UP FLICKERLESS XDR  OFF ALC (F.FAST) --MID (OFF) --AUTO X4 OFF MID CAMERA ID Provide the ID and location for a camera that displays on the screen. For selecting and saving each menu item, refer to “How to use the keyboard controller”. (page 22) 1. Select - . 2. Use the joystick to select a desired character, then press [ENTER]. In the lower input box of the screen, the selected character will be entered.  You can enter up to 54 characters including alphabets, numbers and special characters.  LOCATION : Specify the display position of the camera ID. CAMERA ID ABCDEFGHIJKLMNOPQRSTUVWXYZO 123456789 : ?_+()/ SP SP LOCATION ----------------------------------------------------------------- 3. When done, press [ENTER]. The camera ID will be displayed in the specified position. 26_ setup 00956B-NA_SCC-C7453N-ENG.indb 26 2009-08-13 오후 10:58: IRIS The IRIS menu is useful if you set to adjust the intensity of radiation incoming to the camera.  MANUAL : Adjust the iris level manually. M  The overall brightness target of a camera [ 00] ----I---- BACKLIGHT AREA BLC USER English  ALC : Adjust the open and close of the iris. - LEVEL : Select an overall brightness level. - BLC : With set to , you can specify the BLC area. With AREA set to , you can specify the position and size. ALC LEVEL MANUAL LEVEL [ 00] ----I---- will be set to ALC level 0, while the iris can be adjusted manually. AGC With this, you can adjust the AGC level of a  CAMERA SET  camera. With AGC active, if the signal strength falls CAMERA ID OFF IRIS ALC below the standard level, AGC will amplify the AGC (VERY HIGH) --video signal to automatically improve the DNR MID sensitivity. SHUTTER OFF If is set to , or SENS-UP OFF FLICKERLESS OFF mode, the menu will switch to XDR MID . With the USER ( ) submenu selected, press [ENTER] to display the corresponding screen. In this mode, you can select from VERY LOW to VERY HIGH in 16 levels, enabling deeper, wider choices to your convenience. With the FIX ( ) submenu selected, press [ENTER] to display the corresponding screen. In this mode, you can select an individualized mode in 16 levels, regardless of the brightness. 00956B-NA_SCC-C7453N-ENG.indb 27 English _27 2009-08-13 오후 10:58: setup M  As long as the DAY/NIGHT menu is set to AUTO in Camera Setup, the AGC menu is not available.  As long as FLICKERLESS is set to ON, the AGC mode is not available. MOTION You can specify a level of AGC for controlling the camera motion. This is available only of the SENSE UP menu is set to AUTO. Select F.FAST if you want to monitor a very fast moving object in a low contrast scene, and S.SLOW if monitoring a very slow moving, inanimate object in the same condition.  As long as DAY/NIGHT is set to , the menu is not available. DNR Reduces the noise on the camera image. The higher the level is, the greater the effect is. Set it to to specify the level. SHUTTER You can select a fixed fast electronic shutter speed in 7 options ranging from 1/100 to 1/10k, which is mostly used to take a picture of a fast moving object.  As long as SENSE UP is set to AUTO, FIXED / FLICKERLESS to ON, the SHUTTER menu is not available.  CAMERA SET CAMERA ID IRIS AGC DNR SHUTTER SENS-UP FLICKERLESS XDR  OFF ALC (VERY HIGH) --MID 1/100 (OFF) --(OFF) --MID SENS-UP Automatically senses the darkness level at night or in a low contrast scene, and extends the accumulation time accordingly; you can select or for a bright and sharp image. M  If the SHUTTER menu is set to fixed electronic shutter mode, the SENSE UP menu will not be available.  As long as the FLICKERLESS is set to ON, you cannot set the SENS-UP FIX. 28_ setup 00956B-NA_SCC-C7453N-ENG.indb 28 2009-08-13 오후 10:58: FLICKERLESS  If SHUTTER is set to FIX, SENSE UP to FIX, and AGC to FIX, the menu is not available. English This will prevent possible screen distortion due to a mismatch between the vertical sync frequency and the blinking frequency of the lighting; if set to , the shutter speed will be fixed to 1/100 second. XDR This will correct a brightness difference between different scenes for the optimal visibility by calculating the ambient luminance contrast in a certain unit of pixels. The higher the value is, the higher the correction level is. DAY/NIGHT You can specify a recording mode according to the scene. For selecting and saving each menu item, refer to “How to use the keyboard controller”. (page 22) 1. Select - . 2. Select a screen transition mode according DAY/NIGHT AUTO WHITE BAL to the illumination, and set options as FOCUS MODE ONEAF appropriate. ZOOM SPEED [2]  DAY : Fixed to DAY mode, regardless of DISPLAY ZOOM OFF DISPLAY P/T OFF the scene. DIGITAL ZOOM OFF  NIGHT : Fixed to NIGHT mode, DETAIL [2] regardless of the scene. V-SYNC INT If BURST is set to , the burst signal will be output along with the black-and-white composite video signal.  AUTO : According to the luminance, this AUTO will switch DAY to NIGHT mode, or vice versa. BURST OFF DAYNIGHT - BURST : If set to , the burst BRIGHTNESS MID signal will not be output in NIGHT mode. DWELL TIME 2SEC NIGHTDAY - DAYNIGHT BRIGHTNESS : Specify BRIGHTNESS MID the brightness level switching from DWELL TIME 5SEC COLOR to BW filter. MASK AREA 1 2 Adjusting from HIGH to LOW will cause to switch the filter in a darker screen. - DAYNIGHT DWELL TIME : Time required to determine the filter switch. - NIGHTDAY BRIGHTNESS : Specify the brightness level switching from BW to COLOR filter. Adjusting from HIGH to LOW will cause to switch the filter in a darker screen. 00956B-NA_SCC-C7453N-ENG.indb 29 English _29 2009-08-13 오후 10:58: setup - NIGHTDAY DWELL TIME : Time required to determine the filter switch. - MASK AREA : If there exists a bright MASK AREA spot light source in a night scene, you can specify the size and position as needed. This will prevent an error in switching filter, or failure to determine the filter switch in a night scene where a bright spot light source exists. Any excessively bright area in a night scene will be MASKed.  You can specify MASK 1 and 2 simultaneously.  If is set to , the MASK AREA function is not available.  EXT : The interface to an external alarm enables an automatic switch between DAY and NIGHT mode. If you set to EXT, and alarm #1 to NO/NC in ALARM SETALARM IN SET, the alarm can be used for an input signal in EXT mode of . If an alarm signal occurs, the mode will switch to NIGHT. M  If is set to EXT, ALARM1 in ALARM OUT SET, and ALARM1 in ALARM SET-AUTO SET are not available.  If you use an infrared light source while in AUTO mode, this may cause a failure in AUTO SWITCH or AUTO FOCUS. 30_ setup 00956B-NA_SCC-C7453N-ENG.indb 30 2009-08-13 오후 10:58: WHITE BAL If you need to adjust the color according to the ambient illumination, you can use the function. Illumination is generally referred to as color temperature, which is represented in a measurement of kelvin (K). Color temperatures for ordinary lighting are as follows: In the menu, you can set a mode for correcting the . - ATW1,2 : If you set the menu to or mode, this will monitor the change of the color temperature to correct the as needed. The following color temperature ranges are assured in individual modes: ATW1 : 2500K ~ 9300K (1) ATW2 : 2000K ~ 10000K (suitable to sodium light source) (2) 10000K English For selecting and saving each menu item, refer to “How to use the keyboard controller”. (page 22) Blue sky Rainy 9000K 8000K 7000K 6000K Cloudy 5000K 4000K Partly Cloudy Sunny Fluorescent lamp 3000K 2000K 1000K Halogen lamp Candlelight Tungsten lamp 1 : With mode active in a color temperature environment ranging beyond between 2500K and 9300K, a proper white balance value may not be produced; if this is the case, you are recommended to use mode. 2 : With mode active in a mostly single color environment, the display color and the actual one may differ; so select a mode as appropriate to your color temperature environment. 00956B-NA_SCC-C7453N-ENG.indb 31 English _31 2009-08-13 오후 10:58: setup 1. Select - . 2. Select a mode where you set the .  DAY : You can set the RED, and BLUE value in DAY mode. The screen will be displayed in colors DAY/NIGHT according to your settings. MODE  You can set the R-GAIN, and B-GAIN value only in mode.  If AGC is set to or , the NIGHT WHITE BAL DAY AWC [ 00] ---- I ---[ 00] ---- I ---- RED BLUE R-GAIN B-GAIN [0064] [0064] menu can not be accessed.  NIGHT : You can set the according to the ambient illumination. If NIGHT mode is set to , the will operate in a mode specified in DAY mode at all times; otherwise, the screen will switch to a mode specified in . You can set the RED, BLUE and BRIGHTNESS value in DAY mode. The screen will be displayed in colors according to your settings. WHITE BAL DAY/NIGHT BRIGHTNESS MODE RED BLUE R-GAIN B-GAIN NIGHT MID AWC [ 00] ---- I ---[ 00] ---- I ---- [0064] [0064] 3. According to the specified recording mode, select a mode with necessary options.  ATW1,2 : The camera can automatically adjust the color temperature in real time, according to the ambient conditions. (Color temperature range 1: 2500K ~ 9300K, 2 : 2000K ~ 10000K)  AWC : Pressing [ENTER] on a desired item will perform ATW once.  You can set the R-GAIN/B-GAIN value.  3200K : Set the color temperature to 3200K.  5600K : Set the color temperature to 5600K. - BRIGHTNESS : Specify a brightness level switching from DAY mode to NIGHR mode setting. - RED : Adjust the strength of the red color. - BLUE : Adjust the strength of the blue color. - R-GAIN/B-GAIN : Specify the current color temperature manually. 32_ setup 00956B-NA_SCC-C7453N-ENG.indb 32 2009-08-13 오후 10:58: FOCUS MODE You can select a focus mode according to the angle that you adjusted for camera recording. - ONEAF : Restores focus after the operation of pan/tile/zoom, and operates the same as in unless the operation of pan/tile/ zoom is executed. DAY/NIGHT WHITE BAL FOCUS MODE ZOOM SPEED DISPLAY ZOOM DISPLAY P/T DIGITAL ZOOM DETAIL V-SYNC AUTO [2] ONEAF [2] OFF OFF X16 English - AF : This will monitor the screen continuously to focus automatically. If you adjust the focus manually, that will operate the same as in . This will also restore focus after the operation of pan/tile/zoom. INT - MF : You can adjust the focus manually. M  While you are working on the following objects, may not work properly. If this is the case, use instead. - Very bright object, or dominant object in a dark scene - Object against the rear side of a moist or dirty glass - A scene where nearby and distant objects co-exist - White wall or single-colored object - Venetian blinds and other horizontally striped objects ZOOM SPEED You can adjust the zoom operation speed. DISPLAY ZOOM You can set to display the zoom status on the screen.  It will disappear in about 3 seconds if the zoom factor has no further change. DISPLAY P/T You can set to display the operation status of pan/tilt when it is active.  It will disappear in about 3 seconds if the pan/tilt position has no further change. However, the allowable error is ±2°. DIGITAL ZOOM You can set the maximum allowable digital zoom ratio. Digital Zoom will start operation after it is zoomed in to the maximum optical ratio of x43. If you set DIGITAL ZOOM to x16, you can take a shot at up to x688 (43x16). DETAIL Used to adjust the vertical and horizontal distinction, respectively. 00956B-NA_SCC-C7453N-ENG.indb 33 English _33 2009-08-13 오후 10:58: setup V-SYNC You can set the V-SYNC mode. - If you select , the camera will use the internal synchronization. - If selecting , the camera will use an external power frequency for synchronization. The LL-PHASE can be adjusted as appropriate. AGC COLOR SUP You can adjust the color reproduction range according to AGC. REVERSE AGC COLOR SUP REVERSE POSI/NEGA PIP DIS MID OFF + OFF OFF You can reverse the video signal from left to right, upside down, or vice versa to your convenience. POSI/NEGA You can set the video brightness signal to normal or reverse. PIP You can view a main image with a sub image on the same screen. M  If more than one PRIVACY ZONE is specified, and PRIVACY SET to , the PIP function is not available.  As long as SENSE UP is set to FIXED, PIP menu is not available.  According to the luminance, PIP will disappear if the SENSE UP menu is set to AUTO. DIS If you set it to for a camera that is trembled or vibrated from an ambient change, this will automatically compensate for the flicker on the screen. M  If you set to , the image will be enlarged with digital zoom as much area as compensated. If you set the digital zoom to a larger ratio than the actual enlargement for compensation, the function will be disabled.  may not work properly in the following images: Flat, i.e., no regular-patterned image / Low contrast scene / High frequency image taken under a fluorescent lamp / Regular-patterned image 34_ setup 00956B-NA_SCC-C7453N-ENG.indb 34 2009-08-13 오후 10:58: Intelligent Video You can enable the motion detection and tracking functions. 1. Select
-. 2. Select each item and set appropriately. MOTION You can enable the motion detection and tracking functions. M  INTELLIGENCE MOTION ADVANCED MASK AREA DISPLAY SENSITIVITY RESOLUTION ALARM OUT 1  2 [4] 3 OFF OFF 4 ON English For selecting and saving each menu item, refer to “How to use the keyboard controller”. (page 22) [3]  If you set it to , the option of ADVANCED menu will not be available.  In following situations, motion detection and tracking function may not work properly. - When there is sudden changes of brightness - When the device moves - When a certain object’s movement fills most of the framing area - When there is difficulties in distinguishing the moving object and background ADVANCED You can detect motions and mark the video that contains such motion, and enables tracking of the movement. Selecting the option will mark a region if an existing object disappears, or a new object appears and fixed for a certain period of time. M  In following situations, FIXED/MOVED detection may not work properly. - When multiple motions continue arbitrarily. - When the object that is fixed continues to move in the same position. - When a newly appearing object conceals another object that is moving. MASK AREA 1. Select the number of the area to be masked that will be excluded from motion detection. MASK AREA 2. Select the mask number and set the mask size and its coverage. 00956B-NA_SCC-C7453N-ENG.indb 35 English _35 2009-08-13 오후 10:58: setup DISPLAY When selected , it displays the motion detected and detection of configured advanced function. SENSITIVITY Sets the sensitivity of motion sensor. RESOLUTION The bigger the resolution setting, the smaller the object that can be detected. ALARM OUT When selected , it outputs alarm signal when the motion is detected and on a detection of configured advanced function. ALARM OUT MOTION FIXED/MOVED ON ON PRIVACY ZONE You can set up to 12 privacy zones that will be hided for privacy of the subject when recording. Zone Setup For selecting and saving each menu item, refer to “How to use the keyboard controller”. (page 22) 1. Select
-. 2. Select the number of the zone and press [ENTER]. The Zone setup screen appears. 3. Select the and press [ENTER]. Using the joystick, adjust the camera’s pan, tilt and zoom.  1 7 PRIVACY ZONE 2 8 PRIVACY SET STYLE 3 9 4 10  5 11 6 12 ON MOSAIC1 36_ setup 00956B-NA_SCC-C7453N-ENG.indb 36 2009-08-13 오후 10:58: 4. Select the . Select the pixel level for the SIZE and LOCATION settings. [4] English 5. Select the and press [ENTER]. Using the joystick, set the size of the privacy zone. PRIVACY ZONE SET 1 PIXEL LEVEL 6. Select the and press [ENTER]. Using the joystick, set the position of the privacy zone. 7. Save the changes and move to the previous screen and select the