ECOiTM
Variable Refrigerant Flow (VRF),
Multi-Zone, Heat Pump & Heat Recovery Systems
INTRODUCTION....................................................2
ECOi™ Building Your Business..................................3
ECOi™. Your Building Life Tool..................................4
SANYO OUTDOOR Units..................................6
3 Pipe VRF Heat Recovery
................................6
ECOi Mini VRF...............................11
2 Pipe VRF Heat Pump..............................12
SANYO INDOOR Units.....................................17
KHX series.....................................17
THX series.................................18
AHX series.................................19
XMHX series..............................20
XHX series................................21
UMHX series..............................22
UHX series.................................23
DHX series.................................24
FHX/FMHX series.........................25
SANYO Control System.................................26
ACCESSORIES....................................................30
SERVICES.............................................................31
Company Information................................................32
We are committed
to becoming an
indispensable element
in the lives of people
all over the world.
INTRODUCTION
ECOi™.
Building
Your Business.
SANYO's Brand Vision
SANYO HVAC consistently builds new ideas to help build
your business. By delivering multi-zone options, space-saving
and environmentally friendly designs, our solutions are evolving,
improving solutions.
Flexible Combinations: ECOi allows multiple indoor unit
combinations that provide you with the utmost in flexible
solutions. The system also allows multiple unit connectivity
providing up to 130% of the total capacity of the condensing
unit. This provides for up to 17 indoor units connected to one
condensing unit.
Inverter Control Compressor: All ECOi systems utilize highly
advanced inverter controlled compressor technology. By varying
the rotational speed of the compressor, the inverter control can
precisely match the amount of refrigerant being delivered to
the needs of each zone. This intelligent approach helps realize
excellent efficiencies during partial-load conditions. This allows
all occupants to enjoy consistent room temperature, regardless
of any increases or decreases in the heat load during the day.
ECOi quite simply knows what you need, and when you need
it throughout the day. And even better, it does so with energy
efficiency in mind.
Lower running and life cycle costs: SANYO Ecoi VRF
systems are amongst the most efficient VRF systems on the
market, offering COPs in excess of 4.0 at full load conditions.
The system is also designed to make sure that we reduce the
running cost of each system by using our unique road map
control routine to ensure that the most efficient combination
of compressors are running at any one time. Improved defrost
sequencing also reduces running cost by defrosting each out
door coil in turn when conditions allow.
SANYO has a proud global heritage and over 25 years
experience in the United States. By delivering more multi-zone
options, space-saving designs and offering solutions protect
the environment. Our products reduce your energy costs and
create a more comfortable environment.
Today every conditioning solution must answer multitudes
of project needs, including tighter budgets, flexibility, energy
efficiency and ease of installation, to name a few. ECOi is the
answer. It’s an all-in-one solution that responds to the many
commercial and residential applications.
03
Contractors. Building Support.
At SANYO, we realize contractors are looking for turnkey
installation and support. ECOi™ is quite simply the perfect
building solution. With its modular design and ease of
installation, it’s a solution that can grow with any building
project. In fact, ECOi may just make you remember why you
got into the business in the first place.
Engineers. Designing Confidence.
ECOi™ is absolute confidence. Its flexibility allows
multiple applications and installation configurations. With
a maximum pipe length of up to 984 feet and up to 40
units connected to one outdoor system you can engineer
a perfect solution for all your project needs. ECOi is a
superior modular option that provides for floor-by-floor
commissioning.
Architects. Design Freedom.
Now There’s An Idea.
Of course, nobody understands this more than the
architects who design them. That’s why the ECOi HVAC
system provides more freedom to meet any design need.
With space saving designs, environmental friendship and
ultimate efficiency, you can design your vision first then
marry our system fluidly within your plans.
Owners & Tenants.
With immediate response to changing room capacity
heat loads and varying sun exposures throughout the day,
everybody stays cool and comfortable. ECOi also ensures
individual zone temperature control so each office or
room can be adjusted for personalized comfort. ECOi can
grow with you. As remodeling occurs and building extensions are
planned, ECOi’s modularity lets you simply add on to the system.
With intelligent controllers, VRF technology and R410A refrigerant,
ECOi guarantees continued energy savings and environmental
friendship for years to come.
ECOi has a number of diverse features to meet all your
conditioning needs, including: Flexible Combinations: ECOi
allows multiple indoor unit combinations that provide you with
the utmost in flexible solutions. The system also allows multiple
unit connectivity providing up to 130% of the total capacity of the
condensing unit. This provides for up to 17 indoor units connected
to one condensing unit.
Inverter Control Compressor: All ECOi systems utilize highly
advanced inverter controlled compressor technology. By varying
the rotational speed of the compressor, the inverter control can
precisely match the amount of refrigerant being delivered to
the needs of each zone. This intelligent approach helps realize
excellent efficiencies during partial-load conditions. This allows all
occupants to enjoy consistent room temperature, regardless of any
increases or decreases in the heat load during the day. ECOi quite
simply knows what you need, and when you need it throughout the
day. And even better, it does so with energy efficiency in mind.
For the Living
Inside & Out.
ECOi™.
Your Building
Life Tool.
04
INTRODUCTION
For the buildings requiring simultaneous heating and cooling,
SANYO 3-Way ECOi™ system provides the perfect solution
0505
Commercial office buildings are subject to fluctuating heat levels generated from electronic office equipment,
lighting and varying occupant levels. Also, hotels, nursing homes and other commercial living spaces often have
times when occupants will want either heating or cooling at the same time. The heat recovery system offers the
perfect solution for stabilizing the air temperature by providing all the features of a heat pump system - and the
added flexibility of simultaneous cooling and heating from one refrigerant pipe network.
SANYO’s Combined ECOi 2-Way conditioning solution offers superior heating and cooling coupled with cost effective
installation. A smart conditioning solution for large capacity jobs.
CHDZSERIES
CHDXSERIES
3-Way ECOiTM VRF Heat Recovery
2- Way ECOiTM VRF Heat Pump
Cooling Heating
MODELS (Type: Nominal Cooling Capacity, etc) Volt PH
CHDZ 07263 72,000 BTU Heat Recovery 208-230V/60 HZ 3
CHDZ R07263 72,000 BTU Heat Recovery
With Salt Protection - Special Order
208-230V/60 HZ 3
CHDZ 09663 96,000 BTU Heat Recovery 208-230V/60 HZ 3
CHDZ R09663 96,000 BTU Heat Recovery
With Salt Protection - Special Order
208-230V/60 HZ 3
CHDZ 07263 / CHDZ (R)07263
CHDZ 09663 / CHDZ (R)09663
KEY FEATURES:
*“ECO Friendly” R410A Refrigerant
* Heat Recovery system simultaneous heating-cooling
* One Outdoor Unit Connects As Many As 17 Indoor Units
(50%-130% ratio of indoor to outdoor capacity)
* Heat Pump
* One Outdoor Unit Connects As Many As 17 Indoor Units
(50%-130% ratio of indoor to outdoor capacity)
* CHDZ07263 includes one inverter driven Rotary compressor
* CHDZ09663 includes one inverter driven Rotary compressor
and one AC Constant Speed Scroll Compressor
* Operating Range (Outdoor Ambient)
- Cooling 14 FDB to 113 FDB
- Heating -4 FWB to 59 FWB
* Ultra Quiet Operation As Low As 51.5dB(a)
* Variable Speed DC Fan Motor (ESP adjustable to 0.25” wc)
* Flexible Piping Design:
- 984 Feet - Maximum Total Liquid Line
- 492 Feet - Maximum Outdoor To Most Distant Indoor Unit
- 164 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Above Indoor)
- 131 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Below Indoor)
SANYO’s ECOi Heat Recovery series offers
the ability to heat and cool different
zones simultaneously.
SANYO was the first manufacturer in the
world to develop this energy saving heat
recovery solution. Offering all the features
of our standard heat pump series, the 3-Way
solution can offer even higher energy savings
for the building owner.
* NOTE: *460 Volt Step Down Transformers (460-230) available for 6 and 8 ton condensers
06
CHDZSERIES 3-Way ECOi VRF Heat Recovery
SANYO OUTDOOR
07
DESCRIPTION CHDZ (R) 07263 CHDZ (R) 09663
PERFORMANCE
COOLING CAPACITY: BTU/H
POWER INPUT: KW
HEATING CAPACITY: BTU/H
POWER INPUT: KW
72,000
5.3
81,000
5.79
96,000
7.75
108,000
8.6
ELECTRICAL RATINGS
VOLTAGE RATING
COOLING RUNNING AMPERES
HEATING RUNNING AMPERES
MIN. CIRCUIT AMPACITY
MAX. CIRCUIT AMPACITY
208 - 230 V
15.1 - 14.2 A
16.5 - 15.5 A
24 A
40 A
208 - 230 V
23.2 - 21.6 A
25.4 - 23.7 A
34 A
45 A
COMPRESSOR
TYPE - QUANTITY
MOTOR OUTPUT
REFRIGERATION OIL TYPE
REFRIGERATION OIL CHARGE AMOUNT
CRANKCASE HEATER
REFRIGERANT AMOUNT AT SHIPMENT
REFRIGERANT CONTROL
DEFROST METHOD
HEAT EXCHANGER
CAPACITY CONTROL
Inverter Driven Rotary Type
4.1 kw
FV68S (Ether oil - PVE)
1.4 gal
25 w
R410A - 25.9 lbs
Electronic expansion valve
Reverse-cycle, outdoor unit cycle
Aluminum plate fin / Copper tube
10-100%
Inverter Driven Rotary 1 Fixed Scroll Hermetic
(2.7 + 3.5) kw
FV68S (Ether oil - PVE)
1.96 gal
25 + 32 w
R410A - 25.9 lbs
Electronic expansion valve
Reverse-cycle, outdoor unit cycle
Aluminum plate fin / Copper tube
10-100%
FAN DEVICE
TYPE - QUANTITY
MOTOR OUTPUT
PROTECTIVE DEVICES
CFM
EXTERNAL STATIC PRESSURE
Propeller fan x 1
0.7 kw
High pressure switch, overcurrent (CT method)
5.300
0.04 / 0.25
Propeller fan x 1
0.7 kw
High pressure switch, overcurrent (CT method)
5.650
0.04 / 0.25
TUBING
REFRIGERANT TUBING GAS TUBE
REFRIGERANT TUBING LIQUID TUBE
REF. TUBING DISCHARGE TUBE
REFRIGERANT TUBING BALANCE TUBE
EXTERNAL AIR TEMP. OPERATION RANGE
OPERATION SOUND (HI)
3/4" (Brazing)
ø3/8" (Brazing)
ø5/8" (Brazing)
ø3/8" (Flare)
Cooling: 14 to 109 (DB) / Heating: -4 to 59 (WB) °F
54.5 (Quiet mode: 51.5) dB-A
ø7/8" (Brazing)
ø3/8" (Brazing)
ø3/4" (Brazing)
ø3/8" (Flare)
Cooling: 14 to 109 (DB) / Heating: -4 to 38 (WB) °F
55.0 (Quiet mode: 52.0) dB-A
UNIT DIMENSIONS
Inches (") / lbs.
Color (Munsell code)
81.5"/ 35"/ 35"/ 573 lbs.
Height/ Width/ Depth/ Net Weight
Silky shade (1y 8.5/0.5)
82"/ 35"/ 35"/ 672 lbs.
Height/ Width/ Depth/ Net Weight
Silky shade (1y 8.5/0.5)
CHDZSERIES
3-Way ECOi VRF Heat Recovery
* NOTE: *460 Volt Step Down Transformers (460-230) available for 6 and 8 ton condensers
(R) indicates with salt protection - Special Order
WCHDZ 14463 / WCHDZ 16863 / WCHDZ 19263
WCHDZ 21663 / WCHDZ 24063
WCHDZ 26463 / WCHDZ 28863
KEY FEATURES:
* Three-Way Heat Recovery
* Combine 3 outdoor units up to 24 tons
* “ECO Friendly” R410A Refrigerant
* 208/230V, 3 Phase, 60Hz
* Multiple Compressors For Extra Reliability and Partial Redundancy
* Operating Range (Outdoor Ambient)
-Cooling 14 FDB to 113 FDB
-Heating -4 FWB to 59 FWB
* Ultra Quiet Operation As Low As 52dB(a)
* Variable Speed DC Fan Motors
* Flexible Piping Design:
- 984 Feet - Maximum Total Liquid Line
- 492 Feet - Maximum Outdoor To Most Distant Indoor Unit
- 164 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Above Indoor)
- 131 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Below Indoor)
WCHDZ HEAT RECOVERY COMBINED SERIES.
SANYO’s Combined ECOi 3-Way conditioning solution offers
superior heating and cooling coupled with cost effective
installation. Providing a single refrigerant pipe network means
there’s only one penetration into the building and ultimately
less piping material required, saving you time and money.
A smart conditioning solution for large capacity jobs that
require simultaneous heating and cooling.
WCHDZSERIES 3-Way ECOi VRF Heat Recovery Combined Units
SYSTEM Outdoor Unit Cooling & Heating Power input Control Range
WCHDZ 14463 CHDZ 07263 (quantity of 2) 144,000 & 162,000 BTU/H 10.56/ 11.58 kW 6 - 100%
WCHDZ 16863 CHDZ 07263
CHDZ 09663
168,000 & 189,000 BTU/H 12.97/ 14.39 kW 6 - 100%
WCHDZ 19263 CHDZ 09663 (quantity of 2) 192,000 & 216,000 BTU/H 15.38/ 17.2 kW 6- 100%
WCHDZ 21663 CHDZ 07263 (quantity of 3) 216,000 & 243,000 BTU/H 15.84/ 17.37 kW 6 - 100%
WCHDZ 24063 CHDZ 07263 (quantity of 2)
CHDZ 09663
240,000 & 270,000 BTU/H 18.25/ 20.18 kW 6- 100%
WCHDZ 26463 CHDZ 09663 (quantity of 2)
CHDZ 07263
264,000 & 297,000 BTU/H
20.66/ 22.99 kW 6 - 100%
WCHDZ 28863 CHDZ 09663 (quantity of 3)
288,000 & 324,000 BTU/H
23.07/ 25.8 kW 6 - 100%
* NOTE: *460 Volt Step Down Transformers (460-230) available for 6 and 8 ton condensers
(R) indicates with salt protection - Special Order
08
SANYO OUTDOOR
09
WCHDZSERIES
3-Way ECOi VRF Heat Recovery Combined Units
DESCRIPTION WCHDZ 14463 WCHDZ 16863 WCHDZ 19263
PERFORMANCE
COOLING CAPACITY: BTU/H
POWER INPUT: KW
HEATING CAPACITY: BTU/H
POWER INPUT: KW
includes (1) CHDZ07263
and (1) CHDZ07263
144,000
10.56
162,000
11.58
includes (1)CHDZ07263 and
(1) CHDZ09663
168,000
12.97
189,000
14.39
includes (1) CHDZ09663
and (1) CHDZ09663
192,000
15.38
216,000
17.2
COOLING MODE NOMINAL CONDITIONS
INDOOR: °F WB/ °F DB
OUTDOOR: °F DB
PIPE LENGTH: FEET
LEVEL DIFFERENCE: FEET
80/67
95
25
0
80/67
95
25
0
80/67
95
25
0
HEATING MODE NOMINAL CONDITIONS
INDOOR: °F DB
OUTDOOR: °F DB/ °F WB
PIPE LENGTH: FEET
LEVEL DIFFERENCE: FEET
70
47/43
25
0
70
47/43
25
0
70
47/43
25
0
OPERATING RANGE
COOLING: °F DB
HEATING: °F WB
14 to 113
-4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
COMPRESSOR
TYPE/QUANTITY
CAPACITY CONTROL RANGE: %
2 Inverter driven Rotary
6 - 100%
2 Inverter driven Rotary
& 1 fixed speed scroll
6 - 100%
2 Inverter driven Rotary
& 2 fixed speed scroll
6- 100%
FAN
TYPE/QUANTITY
FAN MOTOR OUTPUT: (KW)
EXTERNAL STATIC PRESSURE
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
POWER SUPPLY
V/PH/HZ
MINIMUM CIRCUITS AMPS (MCA): (A)
MAX. OVERCURRENT PROTECTION (MOCP): (A)
208 - 230/ 3/ 60
52
80
208 - 230/ 3/ 60
60
85
208 - 230/ 3/ 60
68
90
WEIGHT: (LBS) 1168 1267 1366
COIL:
COIL FACE AREA:(SQ. FT.)
NUMBER OF ROWS:
29.5(ea)
4(ea)
29.5(ea)
4(ea)
29.5(ea)
4(ea)
PROTECTION DEVICES
HIGH PRESSURE SWITCH/OVERCURRENT
(CT METHOD)
CRANKCASE HEATERS:(W)
Yes
25 + 25
Yes
25 + 25 + 32
Yes
25 + 32 X 2
* NOTE: *460 Volt Step Down Transformers (460-230) available for 6 and 8 ton condensers
EACH OUTDOOR UNIT REQUIRES A SEPARATE ELECTRICAL FUSED DISCONNECT,
SEE INDIVIDUAL OUTDOOR REQUIREMENTS.
(R) indicates with salt protection - Special Order
WCHDZSERIES 3-Way ECOi VRF Heat Recovery combined units
DESCRIPTION WCHDZ
21663
WCHDZ
24063
WCHDZ
26463
WCHDZ
28863
PERFORMANCE
COOLING CAPACITY: BTU/H
POWER INPUT: KW
HEATING CAPACITY: BTU/H
POWER INPUT: KW
includes (3)
CHDZ07263
216,000
15.84
243,000
17.37
includes (2)
CHDZ07263 and (1)
CHDZ09663
240,000
18.25
270,000
20.18
includes (1)
CHDZ07263 and (2)
CHDZ09663
264,000
20.66
297,000
22.99
includes (3)
CHDZ09663
288,000
23.07
324,000
25.8
COOLING MODE NOMINAL CONDITIONS
INDOOR: °F WB/ °F DB
OUTDOOR: °F DB
PIPE LENGTH: FEET
LEVEL DIFFERENCE: FEET
80/67
95
25
0
80/67
95
25
0
80/67
95
25
0
80/67
95
25
0
HEATING MODE NOMINAL CONDITIONS
INDOOR: °F DB
OUTDOOR: °F DB/ °F WB
PIPE LENGTH: FEET
LEVEL DIFFERENCE: FEET
70
47/43
25
0
70
47/43
25
0
70
47/43
25
0
70
47/43
25
0
OPERATING RANGE
COOLING: °F DB
HEATING: °F WB
14 to 113
-4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
COMPRESSOR
TYPE/QUANTITY
CAPACITY CONTROL RANGE: %
3 Inverter driven Rotary
6 - 100%
3 Inverter driven Rotary
& 1 fixed speed scroll
6 - 100%
3 Inverter driven Rotary
& 2 fixed speed scroll
6 - 100%
3 Inverter driven Rotary
& 3 fixed speed scroll
6 - 100%
FAN
TYPE/QUANTITY
FAN MOTOR OUTPUT: (KW)
EXTERNAL STATIC PRESSURE
1 Propeller (ea)
0.7 kW
.04 / .25
1 Propeller (ea)
0.7 kW
.04 / .25
1 Propeller (ea)
0.7 kW
.04 / .25
1 Propeller (ea)
0.7 kW
.04 / .25
POWER SUPPLY
V/PH/HZ
MINIMUM CIRCUITS AMPS (MCA): (A)
MAX. OVERCURRENT PROTECTION (MOCP): (A)
208 - 230/ 3/ 60
78
120
208 - 230/ 3/ 60
86
125
208 - 230/ 3/ 60
94
130
208 - 230/ 3/ 60
102
135
WEIGHT: (LBS) 1752 1851 1950 2049
COIL:
COIL FACE AREA:(SQ. FT.)
NUMBER OF ROWS:
29.5(ea)
4(ea)
29.5 (ea)
4
29.5 (ea)
4
29.5 (ea)
4
PROTECTION DEVICES
HIGH PRESSURE SWITCH/OVERCURRENT (CT
METHOD)
CRANKCASE HEATERS:(W)
Yes
25 + 25 + 25
Yes
25 + 25 + 25 + 32
Yes
(2 X 25 + 32) + 25
Yes
3 X 25 + 32
* NOTE: *460 Volt Step Down Transformers (460-230) available for 6 and 8 ton condensers
EACH OUTDOOR UNIT REQUIRES A SEPARATE ELECTRICAL FUSED DISCONNECT,
SEE INDIVIDUAL OUTDOOR REQUIREMENTS.
(R) indicates with salt protection - Special Order
10
11
SANYO’s Mini ECOi is suited
for numerous commercial and
premium residential applications.
SANYO OUTDOOR
CHXSERIES
Mini ECOi Multi Split VRF Heat Pump
CHX (R) 03652 / CHX (R) 05252
KEY FEATURES:
* Single Phase 208/230 volts
* One Outdoor Unit Connects As Many As 9 Indoor Units
(50%-130% ratio of indoor to outdoor capacity)
* Inverter Driven Twin Rotary Compressor
* Operating Range (Outdoor Ambient)
- Cooling 14 FDB to 113 FDB
- Heating -4 FWB to 59 FWB
* Ultra Quiet Operation As Low As 51dB(a)
* Variable Speed DC Fan Motor
* Piping:
-656 Feet - Maximum Total Liquid Line
-164 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Above Indoor)
-131 Feet - Maximum Vertical Between Indoor and Outdoor (Outdoor Below Indoor)
* Defrost control, Reverse cycle, microprocessor control
* External finish: Galvanized steel plate with powder paint
* Refrigerant control: Electronic expansion valve
DESCRIPTION CHX (R) 03652 CHX (R) 05252
POWER SOURCE 208-230V/1PH/60Hz 208-230V/1PH/60Hz
PERFORMANCE
COOLING CAPACITY
SEER
HEATING CAPACITY
HSPF
AIR CIRCULATION (HI)
Ducted Non-Ducted Mix
40,000 39,000 39,000 BTU/H
14.20 16.40 15.30
40,500 42,500 41,500 BTU/H
8.20 9.60 8.90
3,530 CFM
Ducted Non-Ducted Mix
51,500 52,000 51,500 BTU/H
14.6 17.3 16
57,500 58,000 58,500 BTU/H
7.7 9.5 8.6
3,530 CFM
ELECTRICAL RATINGS
VOLTAGE RATING
AVAILABLE VOLTAGE RANGE
RUNNING AMPERES
MAX. RUNNING AMPERES
POWER INPUT
MAX. POWER INPUT
MIN. CIRCUIT AMPACITY
MAX CIRCUIT AMPACITY
COOLING HEATING
208 / 230 V 208 / 230 V
187—253 V 187—253 V
14.6 / 13.6 A 14.6 / 13.6 A
23.6 / 23.6 A 23.6 / 23.6 A
2.76 / 2.76 Kw 2.88 / 2.88 Kw
4.85 / 4.85 Kw 4.85 / 4.85 Kw
18 A
30 A
COOLING HEATING
208 / 230 V 208 / 230 V
187—253 V 187—253 V
23.5 / 21.9 A 23.5 / 21.9 A
28 / 28 A 28 / 28 A
4.57 / 4.57 Kw 4.58 / 4.58 Kw
5.72 / 5.72 Kw 5.7 2 / 5.72 Kw
29 A
50 A
REFRIGERANT TUBING
LIMIT OF TUBING LENGTH
LIMIT OF ELEVATION DIFFERENCE
BETWEEN THE 2 UNITS
656 ft
Outdoor unit is higher than indoor unit: 164
Outdoor unit is lower than indoor unit: 131
656 ft
Outdoor unit is higher than indoor unit: 164
Outdoor unit is lower than indoor unit: 131
REFRIGERANT TUBE DIAMETER
LIQUID TUBE IN.
GAS TUBE IN.
3/8"
5/8"
3/8"
3/4"
UNIT DIMENSIONS
INCHES (") / LBS.
SHIPPING WEIGH / VOLUME
EXTERNAL AIR TEMP. OPERATION RANGE
Height/ Width/ Depth/ Net Weight
49”/ 37”/ 14”/ 229 lbs.
247 lbs. / 19.8 ft.3
Cooling:14 to 113 (DB)/Heating: -4 to 59 (WB)
Height/ Width/ Depth/ Net Weight
49”/ 37”/ 14”/ 229 lbs.
247 lbs. / 19.8 ft.3
Cooling:14 to 113 (DB)/Heating: -4 to 59 (WB)
* NOTE: *(R) in Model # indicates Salt Protection - Special Order
12
CHDXSERIES 2-Way ECOi VRF Heat Pump
DESCRIPTION (Type: Nominal Cooling Capacity, etc) Volt PH
CHDX 07263 * 72,000 BTU Heat Pump 208-230V/60 HZ 3
CHDX (R) 07263 * 72,000 BTU Heat Pump
With Salt Protection - Special Order
208-230V/60 HZ 3
CHDX 09663 * 96,000 BTU Heat Pump 208-230V/60 HZ 3
CHDX (R) 09663 * 96,000 BTU Heat Pump
With Salt Protection - Special Order
208-230V/60 HZ 3
* NOTE: *460 Volt Step Down Transformers (460-230) available for 6 and 8 ton condensers
CHDX 07263 / CHDX (R) 07263
CHDX 09663 / CHDX (R) 09663
KEY FEATURES:
* One Outdoor Unit Connects As Many As 17 Indoor Units
(50%-130% ratio of indoor to outdoor capacity)
* CHDX07263 one Inverter Driven Rotary Compressor
* CHDX09663 includes one Inverter Driven Rotary Compressor
and One AC Constant Speed Scroll Compressor
* Operating Range (Outdoor Ambient)
- Cooling 14 FDB to 113 FDB
- Heating -4 FWB to 59 FWB
* Ultra Quiet Operation As Low As 52dB(a)
* Variable Speed DC Fan Motor (ESP adjustable to 0.25” wc)
* Flexible Piping Design:
- 984 Feet - Maximum Total Liquid Line
- 492 Feet - Maximum Outdoor To Most Distant Indoor Unit
- 164 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Above Indoor)
- 131 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Below Indoor)
SANYO’s ECOi is an all-in-one modular
conditioning solution. Suited for
numerous commercial and industrial
applications it offers flexible installation,
superior heating and cooling.
(R) indicates with salt protection - Special Order
13
SANYO OUTDOOR
CHDXSERIES
2- Way ECOi VRF Heat Pump
* NOTE: *460 Volt Step Down Transformers (460-230) available for 6 and 8 ton condensers
(R) indicates with salt protection - Special Order
DESCRIPTION CHDX (R) 07263 CHDX (R) 09663
PERFORMANCE
COOLING CAPACITY: BTU/H
POWER INPUT: KW
HEATING CAPACITY: BTU/H
POWER INPUT: KW
72,000
5.28
81,000
5.79
96,000
7.69
108,000
8.6
ELECTRICAL RATINGS
VOLTAGE RATING
COOLING RUNNING AMPERES
HEATING RUNNING AMPERES
MIN. CIRCUIT AMPACITY
MAX. CIRCUIT AMPACITY
208 - 230 V
15.1 - 14.1 A
16.5 - 15.5 A
26 A
40 A
208 - 230 V
23.0 - 21.4 A
25.4 - 23.7 b A
34 A
45 A
COMPRESSOR
TYPE - QUANTITY
MOTOR OUTPUT
REFRIGERATION OIL TYPE
REFRIGERATION OIL CHARGE AMOUNT
CRANKCASE HEATER
REFRIGERANT AMOUNT AT SHIPMENT
REFRIGERANT CONTROL
DEFROST METHOD
HEAT EXCHANGER
CAPACITY CONTROL
Inverter Driven Rotary Type
4.1 kw
FV68S (Ether oil - PVE)
1.4 gal
25 w
R410A - 25.9 lbs
Electronic expansion valve
Reverse-cycle, outdoor unit cycle
Aluminum plate fin / Copper tube
10-100%
Inverter Driven Rotary
(3 + 3.75) kw
FV68S (Ether oil)
1.56 gal
25 + 32 w
R410A - 25.9 lbs
Electronic expansion valve
Reverse-cycle, outdoor unit cycle
Aluminum plate fin / Copper tube
10-100%
FAN DEVICE
TYPE - QUANTITY
MOTOR OUTPUT
PROTECTIVE DEVICES
CFM
EXTERNAL STATIC PRESSURE
Propeller fan x 1
0.7 kw
High pressure switch, overcurrent (CT method)
5.300
0.04 / 0.25
Propeller fan x 1
0.7 kw
High pressure switch, overcurrent (CT method)
5.650
0.04 / 0.25
TUBING
REFRIGERANT TUBING GAS TUBE
REFRIGERANT TUBING LIQUID TUBE
REFRIGERANT TUBING BALANCE TUBE
EXTERNAL AIR TEMP. OPERATION RANGE
OPERATION SOUND (HI)
3/4" (Brazing)
ø3/8" (Brazing)
ø3/8" (Flare)
Cooling: 14 to 113 (DB) / Heating: -4 to 59 (WB) °F
54.5 (Quiet mode: 51.5) dB-A
7/8" (Brazing)
3/8" (Brazing)
ø3/8" (Flare)
Cooling: 14 to 113 (DB) / Heating: -4 to 38 (WB) °F
55.0 (Quiet mode: 52.0) dB-A
UNIT DIMENSIONS
Inches (") / lbs.
Color (Munsell code)
82"/ 35"/ 35"/ 584 lbs.
Height/ Width/ Depth/ Net Weight
Silky shade (1y 8.5/0.5)
82"/ 35"/ 35"/ 683 lbs.
Height/ Width/ Depth/ Net Weight
Silky shade (1y 8.5/0.5)
14
WCHDXSERIES W 2-Way ECOi VRF Heat Pumps combined units
WCHDX 14463 / WCHDX 16863 / WCHDX 19263
WCHDX 21663 / WCHDX 24063
WCHDX 26463 / WCHDX 28863
KEY FEATURES:
* Heat Pump
* Combine 3 outdoor units up to 24 tons
* Combined Series Allows Up to 40 Indoor Units (50%-130% ratio of
indoor to outdoor capacity)
*“ECO Friendly” R410A Refrigerant
* 208/230V, 3 Phase, 60Hz
* Multiple Compressors For Precise and Efficient Operation
* Operating Range (Outdoor Ambient)
-Cooling 14 FDB to 113 FDB
-Heating -4 FWB to 59 FWB
* Ultra Quiet Operation As Low As 51.5dB(a)
* Variable Speed DC Fan Motors
* Flexible Piping Design:
- 984 Feet - Maximum Total Liquid Line
- 492 Feet - Maximum Outdoor To Most Distant Indoor Unit
- 164 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Above Indoor)
- 131 Feet - Maximum Vertical Between Indoor and Outdoor
(Outdoor Below Indoor)
SANYO’s Combined ECOi outdoor units offer
superior heating and cooling coupled with cost
effective installation. Providing a single refrigerant
pipe network means there’s only one penetration
into the building and ultimately less piping material
required, saving you time and money. A smart
conditioning solution for large capacity jobs.
WCHDX COMBINED SERIES.
SYSTEM Outdoor Unit Cooling & Heating Power input
208/230
Control Range
WCHDX 14463 CHDX 07263 (quantity of 2) 144,000 & 162,000 BTU/H 10.56/11.58 kW 6 - 100%
WCHDX 16863 CHDX 07263
CHDX 09663
168,000 & 189,000 BTU/H 12.97/ 14.39 kW 6 - 100%
WCHDX 19263 CHDX 09663 (quantity of 2) 192,000 & 216,000 BTU/H 15.38/ 17.2 kW 6 - 100%
WCHDX 21663 CHDX 07263 (quantity of 3) 216,000 & 243,000 BTU/H 15.84/ 17.37 kW 6 - 100%
WCHDX 24063 CHDX 07263 (quantity of 2)
CHDX 09663
240,000 & 270,000 BTU/H 18.25/ 20.18 kW 6 - 100%
WCHDX 26463 CHDX 09663 (quantity of 2)
CHDX 07263
264,000 & 297,000 BTU/H
20.66/ 22.99 kW 6 - 100%
WCHDX 28863 CHDX 09663 (quantity of 3)
288,000 & 324,000 BTU/H
23.07/ 25.8 kW 6 - 100%
* NOTE: *460 Volt Step Down Transformers (460-230) available for 6 and 8 ton condensers
(R) indicates with salt protection - Special Order
15
SANYO OUTDOOR
WCHDXSERIES
W 2-Way ECOi VRF Heat Pumps combined units
DESCRIPTION WCHDX 14463 WCHDX 16863 WCHDX 19263
PERFORMANCE
COOLING CAPACITY: BTU/H
POWER INPUT: KW
HEATING CAPACITY: BTU/H
POWER INPUT: KW
includes (2) CHDX07263
144,000
10.56
162,000
11.58
includes (1) CHDX07263 and
(1) CHDX09663
168,000
12.97
189,000
14.39
includes (2) CHDX09663
192,000
15.38
216,000
17.2
COOLING MODE NOMINAL CONDITIONS
INDOOR: °F WB/ °F DB
OUTDOOR: °F DB
PIPE LENGTH: FEET
LEVEL DIFFERENCE: FEET
80/67
95
25
0
80/67
95
25
0
80/67
95
25
0
HEATING MODE NOMINAL CONDITIONS
INDOOR: °F DB
OUTDOOR: °F DB/ °F WB
PIPE LENGTH: FEET
LEVEL DIFFERENCE: FEET
70
47/43
25
0
70
47/43
25
0
70
47/43
25
0
OPERATING RANGE
COOLING: °F DB
HEATING: °F WB
14 to 113
-4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
COMPRESSOR
TYPE/QUANTITY
CAPACITY CONTROL RANGE: %
2 Inverter driven Rotary
6 - 100%
2 Inverter driven Rotary
& 1 fixed speed scroll
6-100%
2 Inverter driven Rotary
& 2 fixed speed scroll
6-100%
FAN
TYPE/QUANTITY
FAN MOTOR OUTPUT: (KW)
EXTERNAL STATIC PRESSURE
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
POWER SUPPLY
V/PH/HZ
MINIMUM CIRCUITS AMPS (MCA): (A)
MAX. OVERCURRENT PROTECTION (MOCP): (A)
208 - 230/ 3/ 60
52
80
208 - 230/ 3/ 60
60
85
208 - 230/ 3/ 60
68
90
WEIGHT: (LBS) 1168 1267 1366
COIL:
COIL FACE AREA:(SQ. FT.)
NUMBER OF ROWS:
29.5(ea)
4(ea)
29.5(ea)
4(ea)
29.5(ea)
4(ea)
PROTECTION DEVICES
HIGH PRESSURE SWITCH/OVERCURRENT
(CT METHOD)
CRANKCASE HEATERS:(W)
Yes
25 + 25
Yes
25 + 25 + 32
Yes
25 + 32 X 2
* NOTE: *460 Volt Step Down Transformers (460-230) available for 6 and 8 ton condensers
EACH OUTDOOR UNIT REQUIRES A SEPARATE
ELECTRICAL FUSED DISCONNECT, SEE INDIVIDUAL
OUTDOOR REQUIREMENTS.
(R) indicates with salt protection - Special Order
16
WCHDXSERIES W 2-Way ECOi VRF Heat Pumps combined units
DESCRIPTION WCHDX
21663
WCHDX
24063
WCHDX
26463
WCHDX
28863
PERFORMANCE
COOLING CAPACITY: BTU/H
POWER INPUT: KW
HEATING CAPACITY: BTU/H
POWER INPUT: KW
includes (3)
CHDX07263
216,000
15.84
243,000
17.37
includes (2)
CDDX07263 and (1)
CHDX09663
240,000
18.25
270,000
20.18
includes (1)
CHDX07263 and (2)
CHDX09663
264,000
20.66
297,000
22.99
includes (3)
CHDX09663
288,000
23.07
324,000
25.8
COOLING MODE NOMINAL CONDITIONS
INDOOR: °F WB/ °F DB
OUTDOOR: °F DB
PIPE LENGTH: FEET
LEVEL DIFFERENCE: FEET
80/67
95
25
0
80/67
95
25
0
80/67
95
25
0
80/67
95
25
0
HEATING MODE NOMINAL CONDITIONS
INDOOR: °F DB
OUTDOOR: °F DB/ °F WB
PIPE LENGTH: FEET
LEVEL DIFFERENCE: FEET
70
47/43
25
0
70
47/43
25
0
70
47/43
25
0
70
47/43
25
0
OPERATING RANGE
COOLING: °F DB
HEATING: °F WB
14 to 113
-4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
14 to 113
-4 to 59
COMPRESSOR
TYPE/QUANTITY
CAPACITY CONTROL RANGE: %
3 Inverter driven
Rotary
6 - 100%
3 Inverter driven Rotary
& 1 fixed speed scroll
6 - 100%
3 Inverter driven Rotary
& 2 fixed speed scroll
6 - 100%
3 Inverter driven
Rotary
& 3 fixed speed scroll
6 - 100%
FAN
TYPE/QUANTITY
FAN MOTOR OUTPUT: (KW)
EXTERNAL STATIC PRESSURE
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
1 Propeller (ea)
0.7 kW (ea)
.04 / .25
1 Propeller
0.7 kW
.04 / .25
POWER SUPPLY
V/PH/HZ
MINIMUM CIRCUITS AMPS (MCA): (A)
MAX. OVERCURRENT PROTECTION (MOCP): (A)
208 - 230/ 3/ 60
78
120
208 - 230/ 3/ 60
86
125
208 - 230/ 3/ 60
94
130
208 - 230/ 3/ 60
102
135
WEIGHT: (LBS) 1752 1851 1950 2049
COIL:
COIL FACE AREA:(SQ. FT.)
NUMBER OF ROWS:
29.5(ea)
4(ea)
29.5(ea)
4(ea)
29.5(ea)
4(ea)
29.5(ea)
4(ea)
PROTECTION DEVICES
HIGH PRESSURE SWITCH/OVERCURRENT (CT
METHOD)
CRANKCASE HEATERS:(W)
Yes
25 + 25 + 25
Yes
25 + 25 + 25 + 32
Yes
(2 X 25 + 32) + 25
Yes
3 X 25 + 32
EACH OUTDOOR UNIT REQUIRES A SEPARATE ELECTRICAL FUSED DISCONNECT,
SEE INDIVIDUAL OUTDOOR REQUIREMENTS.
* NOTE: *460 Volt Step Down Transformers (460-230) available for 6 and 8 ton condensers
(R) indicates with salt protection - Special Order
17
SANYO INDOOR
KHX 0752 / KHX 0952 / KHX 1252 / KHX 1862
KHX 1962 / KHX 2452 / ATK-SVRK56BA
KEY FEATURES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Easy Wall Mount for Any Application
* Washable Long Life Filter
* Electronic Expansion Valve (EEV)
for Accurate Refrigerant Control
* Light Weight, Only 31 lbs. (KHX2452 is 46 lbs.)
* Wired or Wireless Remote Control
* Easy Service
MODELS (Type: Nominal Cooling Capacity, etc) Volt PH
KHX 0752 7500 BTU 208-230V/60 HZ 1
KHX 0952 9600 BTU 208-230V/60 HZ 1
KHX 1252 12000 BTU 208-230V/60 HZ 1
KHX 1862 18000 BTU 208-230V/60 HZ 1
KHX 1962 19000 BTU (special order) 208-230V/60 HZ 1
KHX 2452 25000 BTU 208-230V/60 HZ 1
ATK-SVRK56BA External EEV (required for use with KHX 1962)N/A N/A
KHXSERIES
Wall-Mounted Unit
SANYO’s wall-mounted units work well with any interior
design. Flexible and compact, offering individualized zoned
comfort for complete temperature control throughout the day.
Over five different air flow directions and wireless remotes
provide control in the palm of your hand.
DESCRIPTION KHX 0752 KHX 0952 KHX 1252 KHX 1862 KHX 1962
needs ATK-SVRK56BA KHX 2452
PERFORMANCE
COOLING CAPACITY
HEATING CAPACITY
7,500 BTU/H
8,500 BTU/H
9,600 BTU/H
11,000 BTU/H
12,000 BTU/H
14,000 BTU/H
18,000 BTU/H
20,000 BTU/H
19,000 BTU/H
21,000 BTU/H
25,000 BTU/H
27,000 BTU/H
CURRENT
COOLING
HEATING
0.25/0.26 A
0.25/0.26 A
0.20/0.21 A
0.20/0.21 A
0.20/0.21 A
0.20/0.21 A
0.30/0.32 A
0.30/0.32 A
0.30/0.32 A
0.30/0.32 A
0.37/0.39 A
0.38/0.32 A
POWER INPUT
COOLING
HEATING
50/56 W
50/56 W
50/56 W
50/56 W
50/56 W
50/56 W
61/72 W
61/72 W
61/72 W
61/72 W
72/83 W
72/83 W
HEAT EXCHANGER
FAN TYPE X QUANTITY
FAN AIRFLOW RATE
FAN EXT. STATIC PRESS (230V)
FAN MOTOR TYPE
FAN MOTOR OUTPUT
CROSS FLOW X1
350/280/210
0 IN. WC
AC
30 W
CROSS FLOW X1
350/280/210
0 IN. WC
AC
30 W
CROSS FLOW X1
350/280/210
0 IN. WC
AC
30 W
CROSS FLOW X1
565/495/353
0 IN. WC
AC
30 W
CROSS FLOW X1
565/495/353
0 IN. WC
AC
30 W
CROSS FLOW X1
565/495/350
0 IN. WC
AC
30 W
REFRIGERANT PIPE DIMENSIONS
LOW PRESSURE (FLARE)
HIGH PRESSURE (FLARE)
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
3/8"
5/8"
UNIT DIMENSIONS
Inches (") / lbs.
11.5"/ 39.5"/ 8"/ 31 LBS.
HEIGHT/ WIDTH/ DEPTH/ NET WEIGHT
13"/ 45"/ 9"/ 46 LBS.
HEIGHT/ WIDTH/ DEPTH/ NET WEIGHT
DRAINPIPE DIMENSION 3/4" OD
SOUND LEVELS
(LOW-MED-HIGH) DB(A) @ 230V 28/32/36 28/32/36 28/32/36 35/38/42 35/38/42 35/38/42
18
THXSERIES Ceiling Suspended Unit
DESCRIPTION THX 1252 THX 1852 THX 2452
CAPACITY
COOLING
HEATING
12,000 BTU
14,000 BTU
19,000 BTU
21,000 BTU
25,000 BTU
27,000 BTU
CURRENT
COOLING
HEATING
0.14/0.17 A
0.14/0.15 A
0.15/0.14 A
0.15/0.17 A
0.34/0.31 A
0.34/0.36 A
POWER INPUT
COOLING
HEATING
15/16 W
15/16 W
16/16 W
16/18 W
38/37 W
40/40 W
UNIT DIMENSIONS
Inches (") / lbs.
8.5"/ 36"/ 27"/ 46 lbs.
Height/ Width/ Depth/ Net Weight
8.5"/ 46.5"/ 27"/ 55 lbs.
Height/ Width/ Depth/ Net Weight
HEAT EXCHANGER
FAN TYPE X QUANTITY
FAN AIRFLOW RATE
FAN EXT. STATIC PRESS (230V)
FAN MOTOR TYPE
FAN MOTOR OUTPUT
SCIROCCO X1
450/390/320 - CFM - (H/M/L)
0 - In. WC
DC
60 - W
SCIROCCO X1
450/390/320 - CFM - (H/M/L)
0 - In. WC
DC
60 - W
SCIROCCO X1
653/530/495 - CFM - (H/M/L)
0 - In. WC
DC
60 - W
REFRIGERANT PIPE DIMENSIONS
LOW PRESSURE (FLARE)
HIGH PRESSURE (FLARE)
1/4"
1/2"
1/4"
1/2"
3/8"
5/8"
DRAINPIPE DIMENSION 1" OD 1" OD 1" OD
SOUND LEVELS
(LOW-MED-HIGH) 30/32/35 - DB(A) @ 230V 30/33/36 - DB(A) @ 230V 33/36/38 - DB(A) @ 230V
MODELS (Type: Nominal Cooling Capacity, etc) Volt PH
THX 1252 12,000 BTU 208-230V/60 HZ 1
THX 1852 18,000 BTU 208-230V/60 HZ 1
THX 2452 24,000 BTU 208-230V/60 HZ 1
KEY FEATURES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Low Profile Design Fits Into Numerous Ceiling
Suspended Locations
* One Way Air Discharge with Vanes and Auto
Louvre for Efficient Air Distribution
* Washable Long Life Air Filter
* Electronic Expansion Valve (EEV) for Accurate
Refrigerant Control
* Less Than 9 Inches Tall and Less than 36 Inches
Wide (47 Inches Wide For THX2452)
* Wired or Wireless Remote Control
* Easy Service
THX 1252 / THX 1852 / THX 2452
SANYO’s ceiling suspended units are an ideal solution for
any medium to light commercial space perfectly.
Suited for retail stores, schools and restaurant applications,
its wide air opening provides comfortable airflow and ultra
quiet operation.
SYSTEM/MODEL Components (Type: Nominal Cooling Capacity, etc) Volt PH
07AHX 52
System 7500 BTU 1-Way Ceiling cassette (includes grille) 208-230V/60 HZ 1
AHX 0752 cassette 208-230V/60 HZ 1
PNR-AH1252 grille
09 AHX 52
System 9000 BTU 1-Way Ceiling cassette (includes grille) 208-230V/60 HZ 1
AHX 0952 cassette 208-230V/60 HZ 1
PNR-AH1252 grille
12 AHX 52
System 12000 BTU 1-Way Ceiling cassette (includes grille) 208-230V/60 HZ 1
AHX 1252 cassette 208-230V/60 HZ 1
PNR-AH1252 grille
SANYO INDOOR
AHXSERIES
ONE WAY Ceiling Cassette, with condensate Pump
DESCRIPTION 07AHX 52 09 AHX 52 12 AHX 52
PERFORMANCE
COOLING CAPACITY
HEATING CAPACITY
7,500 BTU/H
8,500 BTU/H
9,600 BTU/H
11,000 BTU/H
12,000 BTU/H
14,000 BTU/H
CURRENT
COOLING
HEATING
0.29/0.28 A
0.28/0.26 A
0.29/0.28 A
0.28/0.26 A
0.32/0.31 A
0.34/0.32 A
POWER INPUT
COOLING
HEATING
48/50 W
44/46 W
48/50 W
44/46 W
52/55 W
50/52 W
HEAT EXCHANGER
FAN TYPE X QUANTITY
FAN AIRFLOW RATE
FAN EXT. STATIC PRESS (230V)
FAN MOTOR TYPE
FAN MOTOR OUTPUT
SCIRROCO X1
282/247/212
0 IN. WC
DC
60 W
SCIRROCO X1
282/247/212
0 IN. WC
DC
60 W
SCIRROCO X1
320/280/250
IN. WC
DC
60 W
REFRIGERANT PIPE DIMENSIONS
LOW PRESSURE (FLARE)
HIGH PRESSURE (FLARE)
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
UNIT DIMENSIONS
Inches (") / lbs.
13"/ 30"/ 24.5"/ 43 LBS.
HEIGHT/ WIDTH/ DEPTH/ NET WEIGHT
DRAINPIPE DIMENSION 1 1/4" OD
SOUND LEVELS
(LOW-MED-HIGH) DB(A) @ 230V 29/31/33
SANYO’s semi-concealed ceiling
units are flexible and space-
saving. A perfect conditioning
solution for small spaces. Barely
visible, the unit blends with any
interior design. Powerful enough
to cool and comfort those inside.
07 AHX 52 / 09 AHX 52/ 12 AHX 52
KEY FEATURES:
*“ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* One-Way Air Throw – Perfect for Small Spaces
* Washable Long Life Air Filter
* Built-In Drain Pump 24 Inch Lift Possible Above
Outlet Drain Connection
* Electronic Expansion Valve (EEV) for Accurate
Refrigerant Control
*Only 13 Inches Tall (Not Including Decorative Panel),
30 Inches Wide and 25 Inches Deep
* Wired or Wireless Remote Control
* Optional Fresh Air Intake
* Easy Service
19
XMHXSERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump4-Way Ceiling Cassette 24" x 24", with Condensate Pump
12 XMHX 52 / 18 XMHX 52
KEY FEATURES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Four Way Air Throw
* Washable Long Life Air Filter
* Built-In Drain Pump 25 Inch Lift
Possible Above Outlet Drain Connection
* Electronic Expansion Valve (EEV)
for Accurate Refrigerant Control
* A Low Profile Unit Perfectly Suited
for Compact Ceiling Voids (as little as 12-14 inches)
* Wired or Wireless Remote Control
* Easy Service
* Optional Fresh Air Intake
SYSTEM/MODEL Components (Type: Nominal Cooling Capacity, etc) Volt PH
12 XMHX 52
System 12000 BTU 4-Way Ceiling cassette 24" x 24" (includes grille) 208-230V/1ø/60 HZ 1
XMHX 1252 cassette 208-230V/1ø/60 HZ 1
PNR-XMH1252 grille
18 XMHX 52
System 18000 BTU 4-way Ceiling cassette 24" x 24" (includes grille) 208-230V/1ø/60 HZ 1
XMHX 1852 cassette 208-230V/1ø/60 HZ 1
PNR-XMH1852 grille
SANYO’s 4-Way semi-concealed ceiling
units areexible, efficient and space-saving.
Now available to fit within standard
24"x24"ceiling grids.
DESCRIPTION 12 XMHX 52 18 XMHX 52
PERFORMANCE
COOLING CAPACITY
HEATING CAPACITY
12,000 BTU/H
14,000 BTU/H
19,000 BTU/H
21,000 BTU/H
CURRENT
COOLING
HEATING
0.22/0.20 A
0.19/0.17 A
0.30/0.32 A
0.27/0.30 A
POWER INPUT
COOLING
HEATING
38/43 W
30/35 W
52/56 W
48/47 W
HEAT EXCHANGER
FAN TYPE X QUANTITY
FAN AIRFLOW RATE
FAN MOTOR TYPE
FAN MOTOR OUTPUT
TURBO X1
320/280/250
DC
20 W
TURBO X1
440/370/320
DC
20 W
REFRIGERANT PIPE DIMENSIONS
LOW PRESSURE (FLARE)
HIGH PRESSURE (FLARE)
1/4"
1/2"
1/4"
1/2"
UNIT DIMENSIONS
Inches (") / lbs.
12.5"/ 24.75"/ 24.75"/ 41 LBS.
HEIGHT/ WIDTH/ DEPTH/ NET WEIGHT
DRAINPIPE DIMENSION 1 1/4" OD
SOUND LEVELS
(LOW-MED-HIGH) DB(A) @ 230V 27/29/31 33/37/41
4-WAY AIR DISCHARGE
24" X 24" SYSTEM
(INCLUDES GRILLE)
20
SANYO INDOOR
XHXSERIES
4-Way Ceiling Cassette 35" x 35", with Condensate Pump
24 XHX 52 / 36 XHX 52
KEY FEATURES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Four Way Air Throw
* Washable Long Life Air Filter
* Built-In Drain Pump 25 Inch Lift
Possible Above Outlet Drain Connection
* Electronic Expansion Valve (EEV)
for Accurate Refrigerant Control
* A Low Profile Unit Perfectly Suited
for Compact Ceiling Voids (as little as 12-14 inches)
* Wired or Wireless Remote Control
* Easy Service
* Branch Duct Available
* Optional Fresh Air Intake
SYSTEM/MODEL Components (Type: Nominal Cooling Capacity, etc) Volt PH
24 XHX 52
System 25000 BTU 4-Way Ceiling cassette 35" x 35" (includes
grille)
208-230V/60 HZ 1
XMX 2452 cassette 208-230V/60 HZ 1
PNR-XMH1252 grille
36 XHX 52
System
36000 BTU 4-Way Ceiling cassette 35" x 35" (includes grille)
208-230V/60 HZ 1
XMX 3652 cassette 208-230V/60 HZ 1
PNR-XMH1852 grille
SANYO’s 4-Way semi-concealed ceiling
units areexible, efficient and
space-saving. Two sides can be adjusted
simply to accommodate corner airflow.
DESCRIPTION 24 XMHX 52 36 XMHX 52
PERFORMANCE
COOLING CAPACITY
HEATING CAPACITY
25,000 BTU/H
27,000 BTU/H
36,000 BTU/H
39,000 BTU/H
CURRENT
COOLING
HEATING
0.29/0.26 A
0.30/0.31 A
0.51/0.46 A
0.54/0.49 A
POWER INPUT
COOLING
HEATING
38/40 W
33/33 W
74/79 W
76/76 W
HEAT EXCHANGER
FAN TYPE X QUANTITY
FAN AIRFLOW RATE
FAN MOTOR TYPE
FAN MOTOR OUTPUT
TURBO X1
705/565/495
DC
50 W
TURBO X1
990/810/740
DC
90 W
REFRIGERANT PIPE DIMENSIONS
LOW PRESSURE (FLARE)
HIGH PRESSURE (FLARE)
3/8"
5/8"
3/8"
5/8"
UNIT DIMENSIONS
Inches (") / lbs.
12"/ 35"/ 35"/ 58 LBS.
HEIGHT/ WIDTH/ DEPTH/ NET WEIGHT
12" / 35" / 35" / 58 LBS.
HEIGHT/WIDTH/DEPTH/NET WEIGHT
DRAINPIPE DIMENSION 1 1/4 "OD
SOUND LEVELS
(LOW-MED-HIGH) DB(A) @ 230V 28/31/34 33/36/39
TWO SIDES CAN BE
ADJUSTED SIMPLY TO
ACCOMMODATE
CORNER AIRFLOW.
21
UMHXSERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump
UMHX 0762 / UMHX 0962 / UMHX 1262
UMHX 1562 / UMHX 1862
KEY FEATURES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Electronic Expansion Valve (EEV) for Accurate
Refrigerant Control
* Adjustable External Static Pressure
* Built-In Drain Pump – 20 Inch Lift
* Wired or Wireless Remote Control
* Bottom or Rear Return Air
* Easy Service
* 8 inches high"
* Low Profile fits into tight ceiling spaces
* Optional Fresh Air Intake
* Washable Long Life Filter
MODELS (Type: Nominal Cooling Capacity, etc) Volt PH
UMHX 0762 7500 BTU ESP = 0.04 / 0.12 208-230V/60 HZ 1
UMHX 0962 9600 BTU ESP = 0.06 / 0.12 208-230V/60 HZ 1
UMHX 1262 12000 BTU ESP = 0.06 / 0.16 208-230V/60 HZ 1
UMHX 1562 15000 BTU ESP = 0.06 / 0.16 208-230V/60 HZ 1
UMHX 1862 19000 BTU ESP = 0.16 / 0.16 208-230V/60 HZ 1
DESCRIPTION UMHX 0762 UMHX 0962 UMHX 1262 UMHX 1562 UMHX 1862
PERFORMANCE
COOLING CAPACITY
HEATING CAPACITY
7,500 BTU/H
8,500 BTU/H
9,600 BTU/H
11,000 BTU/H
12,000 BTU/H
14,000 BTU/H
15,000 BTU/H
17,000 BTU/H
19,000 BTU/H
21,000 BTU/H
CURRENT
COOLING
HEATING
0.22/0.21 A
0.23/0.22 A
0.261/0.25 A
0.28/0.28 A
0.28/0.26 A
0.30/0.37 A
0.34/0.33 A
0.36/0.35 A
0.47/0.43 A
0.51/0.47 A
POWER INPUT
COOLING
HEATING
32/30 W
32/30 W
35/37 W
37/40 W
37/39 W
39/40 W
44/46 W
47/49 W
59/61 W
63/64 W
HEAT EXCHANGER
FAN TYPE
FAN AIRFLOW RATE
FAN EXT. STATIC PRESS (230V)
FAN MOTOR TYPE
FAN MOTOR OUTPUT
CENTRIFUGAL
212 / 247 / 283
0.04 / 0.12 IN. WC
AC
50 W
CENTRIFUGAL
230 / 265 / 300
0.06 / 0.12 IN. WC
AC
50 W
CENTRIFUGAL
247 / 283 / 318
0.06 / 0.16 IN. WC
AC
50 W
CENTRIFUGAL
283 / 336 / 371
0.06 / 0.16 IN. WC
AC
50 W
CENTRIFUGAL
0353 / 406 / 442
0.06 / 0.16 IN. WC
AC
50 W
REFRIGERANT PIPE DIMENSIONS
LOW PRESSURE (FLARE)
HIGH PRESSURE (FLARE)
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
UNIT DIMENSIONS
Inches (") / lbs.
7 7/8", 29 17/32", 25 13/64", 42 LBS
HEIGHT/ WIDTH/ DEPTH/ NET WEIGHT
DRAINPIPE DIMENSION 1 1/4" OD
SOUND LEVELS
(LOW-MED-HIGH) DB(A) @ 230V 25/27/28 27/29/30 28 / 30 / 32 30 / 32 / 34 31 / 33 / 35
8 inches high
Low Profile fits into tight ceiling spaces.
22
SANYO INDOOR
UHXSERIES
Concealed Ducted - Medium Static
DESCRIPTION UHX 0762 UHX 0962 UHX 1262 UHX 1562 UHX 1862 UHX 2462 UHX 3662 UHX 4862 UHX 5462
PERFORMANCE
COOLING CAPACITY
HEATING CAPACITY
7,500 BTU/H
8,500 BTU/H
9,600 BTU/H
11,000 BTU/H
12,000 BTU/H
14,000 BTU/H
15,000 BTU/H
17,000 BTU/H
19,000 BTU/H
21,000 BTU/H
25,000 BTU/H
27,000 BTU/H
36,000 BTU/H
39,000 BTU/H
47,800 BTU/H
54,600 BTU/H
54,600 BTU/H
61,400 BTU/H
CURRENT
COOLING
HEATING
0.45/0.49 A
0.42/0.46 A
0.45/0.49 A
0.42/0.46 A
0.52/0.55 A
0.49/0.54 A
0.52/0.55 A
0.49/0.54 A
0.90/0.96 A
0.89/0.95 A
0.90/0.96 A
0.89/0.95 A
1.15/1.25 A
1.10/1.18 A
1.25/1.34 A
1.13/120 A
1.25/1.34 A
1.13/120 A
POWER INPUT
COOLING
HEATING
92/112 W
87/104 W
92/112 W
87/104 W
107/125 W
100/122 W
107/125 W
100/122 W
183/219 W
182/214 W
183/219 W
182/214 W
235/282 W
224/267 W
254/301 W
230/271 W
254/301 W
230/271 W
HEAT EXCHANGER
FAN TYPE
HI/MED/LOW FAN AIRFLOW RATE
FAN EXT. STATIC PRESS (230V)
FAN MOTOR TYPE
FAN MOTOR OUTPUT
CENTRIFUGAL X1
353/300/247
0.40 IN. WC
AC
50 W
CENTRIFUGAL X1
353/300/247
0.40 IN. WC
AC
50 W
CENTRIFUGAL X1
424/371/318
0.40 IN. WC
AC
70 W
CENTRIFUGAL X1
424/371/318
0.44 IN. WC
AC
70 W
CENTRIFUGAL X1
671/565/459
0.48 IN. WC
AC
100 W
CENTRIFUGAL X1
671/565/459
0.48 IN. WC
AC
100 W
CENTRIFUGAL X1
1060/919/742
0.49 IN. WC
AC
140 W
CENTRIFUGAL X1
1116/1060/883
0.45 IN. WC
AC
140 W
CENTRIFUGAL X1
1166/1060/883
0.45 IN. WC
AC
140 W
REFRIGERANT PIPE DIMENSIONS
LOW PRESSURE (FLARE)
HIGH PRESSURE (FLARE)
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
3/8"
5/8"
3/8"
5/8"
3/8"
5/8"
3/8"
5/8"
UNIT DIMENSIONS
Inches (") / lbs.
12.5"/ 27.5"/ 25"/ 53 LBS.
HEIGHT/ WIDTH/ DEPTH/ NET WEIGHT
12.5"/ 39.5"/ 25"/ 71LBS.
HEIGHT/ WIDTH/ DEPTH/ NET WEIGHT
12.5"/58.5"/ 25"/ 104LBS.
HEIGHT/ WIDTH/ DEPTH/ NET WEIGHT
12.5"/ 58.5"/ 25"/104 LBS.
HEIGHT/ WIDTH/ DEPTH/ NET WEIGHT
12.5"/ 58.5"/ 25"/ 104 LBS.
HEIGHT/ WIDTH/ DEPTH/ NET WEIGHT
DRAINPIPE DIMENSION 1 1/4" OD
SOUND LEVELS
(LOW-MED-HIGH) DB(A) @
230V 24/28/31 24/28/31 24/28/31 26/30/33 27/32/36 27/32/36 31/33/38 33/37/40 33/37/40
UHX 0762 / UHX 0962 / UHX 1262
UHX 1562 / UHX 1862 / UHX 2462
UHX 3662 / UHX 4862 / UHX 5462
KEY FEATURES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Includes 8" round duct connections (two 8" duct collars for 7-15,000 BTU units three
8" duct collars for 18-24,000 BTU unit and four 8" duct collars for 36-54,000 BTUs units)
can be removed for plenum ducting.
* Electronic Expansion Valve (EEV) for Accurate
Refrigerant Control
* Adjustable External Static Pressure
* Built-In Drain Pump – 20 Inch Lift
* Wired or Wireless Remote Control
* Bottom or Rear Return Air
* Easy Service
* Optional Fresh Air Intake
MODELS (Type: Nominal Cooling Capacity, etc) Volt PH
UHX 0762 7500 BTU 0.28 / 0.40 ESP 208-230V/60 HZ 1
UHX 0962 9600 BTU 0.28 / 0.40 ESP 208-230V/60 HZ 1
UHX 1262 12000 BTU 0.28 / 0.40 ESP 208-230V/60 HZ 1
UHX 1562 15000 BTU 0.28 / 0.44 ESP 208-230V/60 HZ 1
UHX 1862 19000 BTU 0.32 / 0.48 ESP 208-230V/60 HZ 1
UHX 2462 25000 BTU 0.32 / 0.48 ESP 208-230V/60 HZ 1
UHX 3662 36000 BTU 0.32 / 0.49 ESP 208-230V/60 HZ 1
UHX 4862 48000 BTU 0.31 / 0.45 ESP 208-230V/60 HZ 1
UHX 5462 54600 BTU 0.31 / 0.45 ESP 208-230V/60 HZ 1
SANYO’s concealed ceiling units are compact and space
saving. Advanced zoning capabilities. Efficient design.
A perfect conditioning solution for shorter duct runs.
23
DHXSERIES Concealed Ducted - Medium-High Static
DESCRIPTION DHX 3652 DHX 4852
CAPACITY
COOLING
HEATING
36,000 BTU
39,000 BTU
47,800 BTU
54,600 BTU
CURRENT
COOLING
HEATING
2.84/2.89 A
2.74/2.80 A
3.24/3.19 A
3.17/3.42 A
POWER INPUT
COOLING
HEATING
548/620 W
528/602 W
644/695 W
627/756 W
UNIT DIMENSIONS
Inches (") / lbs.
16.5"/ 42"/ 24.5"/ 110 lbs.
Height/ Width/ Depth/ Net Weight
18"/ 42"/ 24.5"/ 119 lbs.
Height/ Width/ Depth/ Net Weight
HEAT EXCHANGER
FAN TYPE X QUANTITY
FAN AIRFLOW RATE
FAN EXT. STATIC PRESS (230V)
FAN MOTOR TYPE
FAN MOTOR OUTPUT
CENTRIFUGAL X1
1,060/988/883 - CFM - (H/M/L)
0.70 - In. WC
AC
200 - W
CENTRIFUGAL X1
1,272/1,237/1,160 - CFM - (H/M/L)
0.67 - In. WC
AC
400 - W
REFRIGERANT PIPE DIMENSIONS
LOW PRESSURE (FLARE)
HIGH PRESSURE (FLARE)
3/8"
5/8"
3/8"
5/8"
DRAINPIPE DIMENSION 1 1/4" OD 1 1/4" OD
SOUND LEVELS
(LOW-MED-HIGH) 42/44/45 - DB(A) @ 230V 44/46/47 - DB(A) @ 230V
SANYO’s concealed ceiling units are flexible and space saving,
helping maximize floor and wall space. Advanced zoning
capabilities condition large areas simply and efficiently.
Completely concealed, they offer simple installation.
MODELS (Type: Nominal Cooling Capacity, etc) Volt PH
DHX 3652 36,000 BTU ESP = 0.70" 208-230V/60 HZ 1
DHX 4852 48,000 BTU ESP = 0.67" 208-230V/60 HZ 1
KEY FEATURES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Electronic Expansion Valve (EEV) for
Accurate Refrigerant Control
* Perfect for Long Duct Runs
* Wired or Wireless Remote Control
* Easy Service
* Built-in float safety
DHX 3652 / DHX 4852
A PERFECT APPLICATION FOR
LONGER DUCT RUN INSTALLATIONS.
24
SANYO INDOOR
FHX/FMHXSERIES
Floor Mounted
FMHX 0762 / FMHX 0962 / FMHX 1262
FMHX 1562 / FMHX 1862 / FMHX 2462
KEY FEATURES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Electronic Expansion Valve (EEV) for
Accurate Refrigerant Control
* Wired or Wireless Remote Control
* Easy Service
* Washable Long Life filter
FLOOR MOUNTED
WITH OUT DECORATIVE PANEL
FHX 0762 / FHX 0962 / FHX 1262
FHX 1562 / FHX 1862 / FHX 2462
KEY FEATURES:
* “ECO Friendly” R410A Refrigerant
* 208/230V, 1 Phase, 60Hz
* Electronic Expansion Valve (EEV) for
Accurate Refrigerant Control
* Wired or Wireless Remote Control
* Easy Service
* Washable Long Life filter
FLOOR MOUNTED
WITH DECORATIVE PANEL
DESCRIPTION FHX/FMHX
0762
FHX/FMHX
0962
FHX/FMHX
1262
FHX/FMHX
1562
FHX/FMHX
1862
FHX/FMHX
2462
CAPACITY
COOLING
HEATING
7,500 BTU
8,500 BTU
9.600 BTU
11,000 BTU
12,000 BTU
14,000 BTU
15,000 BTU
17,000 BTU
19,000 BTU
21,000, BTU
24,000 BTU
27,000 BTU
CURRENT
COOLING
HEATING
.22/.24 A
.22/.23 A
.22/.24 A
.22/.23 A
.42/.44
.40/.42
.58/.60
.53/.55
.58/.60
.53/.55
.61/.63
.56/.58
POWER INPUT
COOLING
HEATING
45/54 W
43-50 W
45/54 W
43-50 W
86/101
83/96
116/134
106/122
116/134
106/122
119/138
109/125
FHX UNIT DIMENSIONS
Inches (") / lbs.
24.25"/42"/9"/64 lbs.
Height/ Width/ Depth/ Net Weight
24.2"/42"/9"/64 lbs.
Height/ Width/ Depth/ Net Weight
24.2"/42"/9"/64 lbs.
Height/ Width/ Depth/ Net Weight
24.0"/54.5"/9"/86 lbs.
Height/ Width/ Depth/ Net Weight
24.0"/54.5"/9"/62 lbs.
Height/ Width/ Depth/ Net Weight
24.0"/54.5"/9"/62 lbs.
Height/ Width/ Depth/ Net Weight
FMHX UNIT DIMENSIONS
Inches (") / lbs.
24.25"/35.5"/9"/46 lbs.
Height/ Width/ Depth/ Net Weight
24.25"/35.5"/9"/46 lbs.
Height/ Width/ Depth/ Net Weight
24.25"/35.5"/9"/46 lbs.
Height/ Width/ Depth/ Net Weight
24.25"/48"/9"/62 lbs.
Height/ Width/ Depth/ Net Weight
24.25"/48"/9"/62 lbs.
Height/ Width/ Depth/ Net Weight
24.25"/48"/9"/62 lbs.
Height/ Width/ Depth/ Net Weight
HEAT EXCHANGER
FAN TYPE X QUANTITY
FAN AIRFLOW RATE
FAN MOTOR OUTPUT
Centrifugal
247/212/177
10 W
Centrifugal
247/212/177
10 W
Centrifugal
318/247/212
20 W
Centrifugal
424/318/283
20 W
Centrifugal
530/459/389
30 W
Centrifugal
601/495/424
60 W
REFRIGERANT
PIPE DIMENSIONS
LOW PRESSURE (FLARE)
HIGH PRESSURE (FLARE)
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
1/4"
1/2"
3/8"
5/8"
DRAINPIPE DIMENSION 1 1/4" OD 1 1/4" OD 1 1/4" OD 1 1/4" OD 1 1/4" OD 1 1/4" OD
SOUND LEVELS
(LOW-MED-HIGH) 28/30/33 28/30/33 29/35/39 31/35/38 31/36/39 35/38/41
25
CONTROL SYSTEMS
SANYO’s system control network is the heart and soul
of the ECOi™ unit, enabling it to live with the living
inside. With a simple two-wire loop installation,
we put control in your hands, literally. No outside
specialists required, it’s an all-in-one solution for
you, and a way to further build profits by keeping
installation in-house. The logic resides in the ECOi
system and the control is the gateway.
RCS-TM80BG / RCS-BH80AAB.WL / RCS-SH80AAB.WL
RCS-TRP80AAB.WL / RCS-XM18AAB.WL
RCS-SH1AAB.WL / RCS-KR1EG / SHA-KC64UG
SHA-TM64AGB / SHA-KT256EA / SHA-KA128AAB
ART-K45AGB / SHA-LN16UBA / BMS-CTRL1
TECS-5000KA / TECS-5000AA / TECS-5000GA
TECS-5000BA / TECS-5000WA
PART NUMBER DESCRIPTION NOTES
RCS-TM80BG WIRED REMOTE CONTROLLER — 7- day setback, mode, temp, service, etc.
RCS-BH80AAB.WL WIRELESS REMOTE CONTROLLER — For use with UHX, UMHX, DHX, FHX and FMHX models
RCS-SH80AAB.WL WIRELESS REMOTE CONTROLLER — For use with XHX models
RCS-TRP80AAB.WL WIRELESS REMOTE CONTROLLER — For use with AHX and THX models
RCS-XM18AAB.WL WIRELESS REMOTE CONTROLLER — For use with XMHX models
RCS-SH1AAB WIRELESS REMOTE CONTROLLER — For use with KHX models
RCS-KR1EG SIMPLE REMOTE CONTROLLER (wired) — on/off, Mode, Temp, Fan Speed, Flap, Service Function
SHA-KC64UG SYSTEM CONTROLLER — Set individual indoor unit temps for up to 4 zones, 16 indoor units max per zone
SHA-TM64AGB SCHEDULE TIMER — Thermal On/Off at program times only, no set back temperature
SHA-KT256EA INTELLIGENT CONTROLLER ( Web Enabled ) — Controls Max of 256 indoor units with SHA-KA128AAB
SHA-KA128AAB COMMUNICATIONS ADAPTOR — Used with INTELLIGENT CONTROLLER and BMS interface
ART-K45AGB REMOTE SENSOR
SHA-LN16UAB LONWORKS INTERFACE — Maximum of 16 indoor units
BMS-CTRL1 BMS INTERFACE — BACnet, LONworks, N2 or MODBUS (also requires SHA-KA128AAB)
TECS-5000KA STAIMS — Base Software Package
TECS-5000AA STAIMS — Electrical Power Distribution Proportioning Software (also requires TECS-5000KA)
TECS-5000GA STAIMS — Layout Graphic Display Software (also requires TECS-5000KA)
TECS-5000BA STAIMS — BACnet Interface Software (also requires TECS-5000KA)
TECS-5000WA STAIMS — Web Enabling Software (also requires TECS-5000KA)
NO OUTSIDE SPECIALISTS REQUIRED,
IT’S AN ALL-IN-ONE SOLUTION FOR YOU.
Simple System Control Network S-Net
26
SANYO Control System
27
CONTROL SYSTEMS
Simple System Control Network
WIRED REMOTES
SIMPLE TO INSTALL
KEY FEATURES: (SIMPLE REMOTE)
* Thin and Easy To Read
* Simple To Install and Use
* Can Be Adapted for Use On All ECOi Indoor Units
* Mode
* Operating Mode (Heating/Cooling/Auto/Dry/Fan)
* Vacation Mode for Continued Energy Efficiencies
* Fan Speed Control
* Set Temperature
* On/Off
* Airflow Direction
* Perfectly Suited for Applications Where Simpler
Functionality is Required (ie: Hotel Rooms, Nursing
Homes, Offices)
KEY FEATURES (STANDARD REMOTE/7 DAY TIMER):
* Thin and Easy To Read
* Simple To Install and Use
* Can Be Adapted for Use On All ECOi Indoor Units
* Fan Speed Control
* Airflow Direction
* Operating Mode (Heating/Cooling/Auto/Dry/Fan)
* Vacation Mode for Continued Energy Efficiencies
* Full 7 Day Set-Back Functionality, With Up To 6 Time
Periods/Day
* Full System Diagnostic Capability
(Diagnostic History Provides Immediate View of System
Past and Present.)
They enable the user to truly take control of the entire
system, from mode, temperature, airflow, and system
diagnosis, all through an easy-to-read liquid crystal
display. Control at your fingertips.
WIRELESS REMOTES
CONTROL IN THE PALM
OF YOUR HAND.
KEY FEATURES:
* Thin and Easy To Read
* Simple To Install and Use
* Can Be Adapted for Use On All ECOi Indoor Units
* Fan Speed Control
* Timer Mode Start/Stop
* Timer Mode On/Off
* Operating Mode
* Inspection/Test Indication
* Remote Can Be Configured To Sense Temperature
RCS-SH1AAB
For Use With KHX Indoor Units
SANYO’s wireless remotes control more than comfort.
RCS-SH80AAB.WL
For Use With XHX Indoor Units
RCS-TRP80AAB.WL
For Use With AHX and THX Indoor Units
Simple remotes offer control where minimal functionality is best suited for those
inside. SANYO’s Standard Remote with 7 Day Timer is perfectly suited
for those requiring more programmed management over multiple zones.
By offering immediate diagnostics and up to six-daily set temperature schedules,
it’s a perfectly controlled solution offering intuitive simplicity.
SANYO’s wired remote controls offer multiple conditioning solutions
to meet the needs of any project.
RCS-KR1EG
Simple Remote Controller
RCS-TM80BG
Standard Remote/7 Day Timer
For Use With All Indoor Units
RCS-BH80AAB.WL
For Use With UHX, UMHX,
DHX, FHX and FMHX Indoor Units
CONTROL SYSTEMS Simple System Control Network
SHA-KT256BA
Intelligent Controller
KEY FEATURES (INTELLIGENT CONTROL):
* 6.5 Inch Touch Screen Panel
* Controls up to 256 Indoor units with added
Communication Adapter (128 indoors without)
* New Control Wiring System (S Net) Connects Up
To 64 Units To a Single Control Line
* Offers a Maximum Installation of Two System
Controls (One Main, One Sub)
* Provides Individual Tenant Billing data for
3 systems addition systems are done by adding
Communication Adapters. Requires watt hour meters
* Provides Individual Tenant Billing Data Through
Calculations Based on a Per-Tenant Basis
* Individual Zone Override Feature
(High/Low Setting)
* Web Accessible/Real Time Diagnostics
Through Individual IP Address
* Diagnostic History of System Past and Present
MULTIPLE ZONE
CONTROLLERS
THE HEART AND SOUL
OF CONDITIONING.
KEY FEATURES (SYSTEM CONTROL):
* Controls Up To 64 Units Into
4 Individualized Zones
* Alarm and Operational Signal Output
* Single Access Points for All Connected
Wired Remotes
Controls Up To 64 Units Into 4 Individualized Zones
SANYO’s system and intelligent controls are the central nervous system
to the conditioning system. The gateway to all data, temperature and
system diagnostics.
Web Accessible/Real Time Diagnostics Through Individual IP Address
SHA-KC64UG
System Controller
CONTROLS UP TO
256 INDOOR UNITS
28
SANYO Control System
29
CONTROL SYSTEMS
Building Management Integration
KEY FEATURES:
* Communicate With LonWorks Compatible Systems
* Start/Stop
* Controls Up To 16 Groups (Maximum 64 Indoor Units)
* For 17 or more groups of indoor units connect additional
interface units.
* Temperature Setting, Fan Speed, etc.
* Schedule Time Setting
* Alarm Notification
KEY FEATURES:
* Able to provide BMS integration to a variety of BMS
protocols including BACnet, Modbus LonWorks and N2
* Communicates with up to 90 indoor units and 10 out
door units (note; N2 can communicate with 40 indoor
and 10 outdoor units)
* Provides control of operating mode, fan, set temperature
* Provides status of operating modes and alarm status
SANYO’s LonWorks interface integrates into many compatible
Building Management Systems. Single point of control. Access
to all of the ECOi™ conditioning mechanics.
SANYO’s BMS Controller sets a new standard for multiple
equipment protocol conversion.
LONWORKS INTERFACE
BMS CONTROLLER
SHA-LN16UAB
LonWorks Interface
BMS-CTRL1
BacNet Interface
SINGLE POINT OF CONTROL
BMS-CTRL1
BMS-CTRL1
NETWORK DIAGRAM
Building Automation
System
OEMPrtl Pro
(Up to 10 outdoor units & 90
indoor units)
Communication
Adaptor
Outdoor unit Remote
Controller
Remote
Controller Weekly
Timer
Group control
Group control
BACnet
LonWorks
Modbus
N2
30
ACCESSORIES
PART NUMBER DESCRIPTION 2-Way Distribution Kits (cut to fit)
Simple System Control Network
APR-P160UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 2 Pipe indoor Unit Piping - Up to 76,400 BTUs
APR-P680UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 2 Pipe indoor Unit Piping - 76,500 to 232,000 BTUs
APR-P1350UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 2 Pipe indoor Unit Piping - 232,200 to 460,700 BTUs
APR-CHP680UK DISTRIBUTION JOINT KIT CUT TO FIT Used to Connect Multiple 2 Pipe Outdoor Units - Up to 232,000 BTUs
APR-CHP1350UK DISTRIBUTION JOINT KIT CUT TO FIT Used to Connect Multiple 2 Pipe Outdoor Units - 232,200 to 460,700 BTUs
3-Way Distribution Kits (cut to fit)
APR-RZP224UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 3 Pipe Indoor Unit Piping - Up to 76,400 BTUs
APR-RZP680UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 3 Pipe Indoor Unit Piping - 76,500 to 232,000 BTUs
APR-RZP1350UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 3 Pipe Indoor Unit Piping - 232,200 to 460,700 BTUs
APR-CHRZP900UK DISTRIBUTION JOINT KIT CUT TO FIT Used to Connect Multiple 3 Pipe Outdoor Units - Up to 307,100 BTUs
3-Way Solenoid Valve Kits
ATK-RZP56BAWB SOLENOID VALVE KIT Total Indoor Capacity of Less than 19,000 BTUs (for 3 Pipe System)
ATK-RZP160BAWB SOLENOID VALVE KIT Total Indoor Capacity of 19,100 to 54,600 BTUs (for 3 Pipe System)
Ball Valves
BVT 14 1/4" Ball Valve With Access Port Fitting
BVT 38 3/8" Ball Valve With Access Port Fitting
BVT 12 1/2" Ball Valve With Access Port Fitting
BVT 58 5/8" Ball Valve With Access Port Fitting
BVT 34 3/4" Ball Valve With Access Port Fitting
BVT 78 7/8" Ball Valve With Access Port Fitting
BVT 118 1-1/8" Ball Valve With Access Port Fitting
BVT 138 1-3/8" Ball Valve With Access Port Fitting
BVT 158 1-5/8" Ball Valve With Access Port Fitting
460 Transformers
ACC-195674 460V TO 230V, 11 KVA TRANSFORMER For Use With CHDX07263, or CHDZ07263, One Per Outdoor Unit
ACC-195679 460V TO 230V, 14 KVA TRANSFORMER For Use With CHDX09663, or CHDZ09663, One Per Outdoor Unit
Mini Condensate Pumps
ASP-MA115 115 VOLT MINI AQUA ASPEN CONDENSATE PUMP Max 26' Lift, 3.7 GPH @ 0 Lift, 0.8 GPH @ 26'
ASP-MA230 230 VOLT MINI AQUA ASPEN CONDENSATE PUMP Max 26' Lift, 3.7 GPH @ 0 Lift, 0.8 GPH @ 26'
ASP-ML115 115 VOLT MINI LIME ASPEN CONDENSATE PUMP Max 26' Lift, 3.7 GPH @ 0 Lift, 0.8 GPH @ 26'
ASP-ML230 230 VOLT MINI LIME ASPEN CONDENSATE PUMP Max 26' Lift, 3.7 GPH @ 0 Lift, 0.8 GPH @ 26'
ASP-MO115 115 VOLT MINI ORANGE ASPEN PUMP Max 26' Lift, 3.7 GPH @ 0 Lift, 0.8 GPH @ 26'
ASP-MO230 230 VOLT MINI ORANGE ASPEN PUMP Max 26' Lift, 3.7 GPH @ 0 Lift, 0.8 GPH @ 26'
CMB-FS140AA FRESH AIR CHAMBER For Use With XHX2452 and XHX3652 Indoor Units Only (Requires CMB-GS140AA)
31
SERVICES
SERVICES
Simple System Control Network
PART NUMBER DESCRIPTION
ECO-SC-4 ECOi COMMISSIONING (Per normal business day, up to 24 tons)
IC-SC-1 COMMISSIONING OF INTELLIGENT CONTROLLER (Base fee for each Intelligent Controller)
IC-SC-INDOOR COMMISSIONING OF INTELLIGENT CONTROLLER (Indoor Units)
LW-SC-1 COMMISSIONING OF LONWORKS INTERFACE MODULE (Base fee)
LW-SC-INDOOR COMMISSIONING OF LONWORKS INTERFACE (Indoor Units fee)
PP-SC-1 COMMISSIONING OF INTELLIGENT BACnet INTERFACE (Base fee for each BMS-CTRL 1)
PP-SC-INDOOR COMMISSIONING OF INTELLIGENT BACnet (Indoor Units fee)
CA-SC-1 COMMISSIONING OF COMMUNICATIONS ADAPTER (Base fee for each Comm. Adapter)
CA-SC-INDOOR COMMISSIONING OF COMMUNICATIONS ADAPTER (Indoor Units fee)
STAIMS-SC-1 COMMISSIONING OF STAIMS MANAGEMENT SYSTEM (Base fee for each overall system)
STAIMS-SC-INDOOR COMMISSIONING OF STAIMS MANAGEMENT SYSTEM (Indoor Units fee)
AC-SC-1 PROGRAM 2-WAY SYSTEM TO ENABLE AUTO CHANGEOVER OF MODE (Base fee /Indoor Units fee)
AC-SC-INDOOR PROGRAM 2-WAY SYSTEM TO ENABLE AUTO CHANGEOVER OF MODE (Indoor Units fee)
IPO-SC-1 PROGRAM "IGNORE INDOOR POWER OFF FAILURE" FOR 2-WAY SYSTEM (Base fee /Indoor Units fee)
IPO-SC-INDOOR PROGRAM "IGNORE INDOOR POWER OFF FAILURE" FOR 2-WAY SYSTEM (Indoor Units fee)
CNBH COMMISSIONING COMPLETED DURING NON-BUSINESS HOURS OR NON-BUSINESS DAYS
COUS ALL COMMISSIONING OF SYSTEMS OR COMPONENTS OUTSIDE CONTINENTAL U.S.
RP-SIT-1 TRAINING - MINI SPLIT SYSTEMS (1 class per day at Customer Location)
RP-SIT-2 TRAINING - MINI SPLIT SYSTEMS (2 classes / same location / same day)
ECOi-IST TRAINING - ECOi INSTALLATION AND COMMISSIONING TRAINING (at customer location)
ECOi-SERT TRAINING - ECOi SERVICE TRAINING (at customer location)
TOUS TRAINING (Conducted outside of the Continental U.S.)
ECO-SIT-4 TRAINING (On-Site Supervised ECOi installation training)
ECO-SIT-NR TRAINING (Supervised installation On-Site training where attendee's did not show up agreed upon)
ECO-SIT-OS TRAINING (Supervised installation Training Outside Continental U.S.)
ACC-CR-USB Pac Checker Service & diagnostics tool for all ECOi and SANYO Splits greater than 26,000 BTUs
Usage
The air conditioners listed herein are only for cooling/heating areas used by
people. Do not use the unit for foods, animals, plants, precision machines,
works of art or other objects. Doing so may cause damage to the unit. Do not
use the unit for vehicles or vessels. Doing so may cause unit water leakage
and short circuiting.
Please read the Operating Instructions carefully and use the air conditioner
properly.
Requires a qualified technician/installer to install the air conditioner.
Improper self-installation may result in water leakage, electric shock or fire.
When installing in a small room, take measures to keep refrigerant leakage
within acceptable density limits, as outlined by local/national safety code
requirements.
Do not install where inflammable gas may leak or inflammable objects
exist. Do not install where there is any inflammable gas emission, inflow or
leftover, or where carbon fibers are in the air. This could be the cause of fire.
Location
Blocking air intake or outlet can be the cause of trouble including the
loss of air flow power, or short-cycled air emission drawn into the
intake. Be sure to install in an airy place.
Avoid Installation in Highly Humid Locations
(1) Avoid installation where the humidity is excessive. This causes
condensation during cooling.
(2) Installation in a room where the temperature and humidity are
high around the ceiling due to sunlight will result in condensation.
Use insulation or take other preventive measures to block the
sunlight.
Exposure to Oil
Avoid installation where there is exposure to oil or soot (such as in
kitchens or machinery plants). Oil will adhere to the heat exchange.
This will lower heat exchange performance, emit mist, or deform or
damage synthetic resin parts.
Cleaning
After using the air conditioner for several seasons, the insides
become dirty and this results in low performance. In addition to
regular cleaning, a maintenance contract with a service person is
recommended.
Features of Heat Pump Heating
Heating power (kW) indicated in the catalog is based on the following
conditions: outdoor temperature of 47°F (DB) and indoor temperature of
70°F (DB), as specified by ARI. Heating capacity decreases as outdoor
temperature drops. Therefore, if heating power is insufficient due to low
outdoor temperature, use the air conditioner together with other heating
equipment. When heated air rises and collects in a room with a high
ceiling, install an air circulator as well.
Operation Range
Outdoor Air Intake Temperature:
Cooling: 14 ~ 109°F (DB) Heating: - 4 ~ 59°F (WB)
Noise Emissions
The noise emission rate indicated in the catalog shows values (A
scale) measured in an anechoic chamber. In actual installation
conditions, noise emission is generally greater than the indicated
rate due to surrounding noise and echoing.
Odor Emissions
Even though an air conditioner does not contain odor-emitting parts,
discharged air can, in certain conditions, have an unpleasant odor.
This is the result of odorous particles such as ones from smoke,
cosmetics, and foods, affixing themselves to the air conditioner.
Although the odor does not affect the performance, cleaning the air
filter and the inside of the air conditioner is recommended.
Noise Caused by Electromagnetic Waves
When installing near equipment that emits electromagnetic waves,
be sure that the air conditioner does not suffer noise damage.
Remote Control Wiring
For remote control wiring and control wiring between indoor units,
do not install with the power wiring (208/230V) in the same tube nor
wherever power wiring exists. Doing so may cause a malfunction
Do not install an air conditioner in a room where the limit density will be exceeded if refrigerant leaks. The refrigerant (R410A) used by this system is it-
self a safe refrigerant; however, if for some reason the refrigerant leaks and the limit density is exceeded, there is a risk of injury to persons due to a lack
of oxygen. For further information, ask your dealer or consult references such as an engineering manual to ensure you install the air conditioner correctly.
For further information and training or to request additional product catalogs, please contact:
SANYO North America Corporation
Commercial Solutions Division
1690 Roberts Blvd., NW Suite 110
Kennesaw, GA 30144
Phone: (678) 355-6635
Fax: (678) 355-6684
Web: http://us.sanyo.com/hvac
©2011 SANYO North America Corporation. All rights reserved. CSDHVACECO0111
Dealer Network Courses: http://us.sanyo.com/hvac/Dealer-Certification
ECOi Web Based Dealer Training Video: http://us.sanyo.com/hvac/On-Demand-Videos
• Includes ECOi Installation & Commissioning procedures and much more.
ISO Certification
SANYO Electric Air Conditioning Co., Ltd. (Tochigi Japan)
ISO 9001 ISO 14001
Certificate Number: JQ116B Certificate Number: EC00J0303-33
Caution On Installation and Use
Safety Precautions

Navigation menu