Data Acquisition System

MTR-5000
MTR-L03
Monitors operating conditions
by PC
Stores operating records
in the PC
Informs a user of abnormality
of device by e-mail
Operating conditions can be
set through LAN.
Two-step/day operation
is programmable.

Cooled Incubator

MIR-254

CO2 Incubator

MCO-19AIC

CO2 Incubator

MCO-80IC

Biomedical Freezer

MDF-U537D

Ultra-Low Freezer

Ethernet (LAN) Interface

MDF-U53V

MTR-L03

Connection examples of a monitoring computer and
SANYO biomedical devices to be monitored by LAN*
*For connectable devices, consult with our company.
*Those devices and the monitoring computer are connected using the special
software, MTR-5000.
*A personal computer is not included in this system.

SANYO Data acquisition software

MTR-5000

Data Acquisition System
Features
• Device-related information such as
temperature, CO2 and O2 concentration,
and operating condition can be
integratedly monitored with one LANconnected personal computer.
Items that can be monitored depend on the
connected devices.

• Operating records are stored in
sequence in the PC. It is unnecessary to
fill in paper records or to enter in a
record book. It is easy to convert the
data into a graph.
Please note that there is a case in which data must
be recorded on a paper.

• Devices can be set up remotely from a
distant point, which saves entering a
clean room.
When the operating setting can be changed through
the network, it is impossible to change the
operation setting on the panel of each device.

Specifications
• Setting the upper/lower limits will cause
you to be informed of an abnormality by
e-mail if the data is out of the range, and
you will also be informed when the
system recovers from the abnormality.
In addition, the system can be set so
that the device conditions will be
informed at a designated time whether
or not there is an abnormality.
A mail account which can be connected to an
SMTP-compatible mail server is required.

Model
Product name
Exterior
dimensions
(W x D x H)
Power supply

• System access is protected by
ID/Password.

Main functions

Ethernet (LAN) Interface
74 x 63 x 58mm
(2.9” x 2.5” x 2.3”)
DC5V (to be supplied from the
attachment device)

Output terminal RJ-45 twist pair cable 8-pin
connector
Compatible
protocol

TCP/IP *Only static IP
(Impossible to use DHCP.)

Note

MTR-L03 is not equipped with
sensors for temperature, etc. As
information such as in-box
temperature, etc., results
measured at the sensors of the
incubators and freezers are
transmitted to the network.

Model
Product name

MTR-5000

• Two-step/day operation to set up two
different temperatures is
programmable.
For example, energy saving can be expected by
changing to different setting temperatures for day
and night operations.

MTR-L03

SANYO Data acquisition software

No. of devices to
32 devices at most (up to 100 ch)
be monitored
Devices to be
monitored

SANYO biomedical devices
connected to MTR-L03 or MTR480 (RS232C or RS-485)

Monitoring PC

CPU: Core2DUO or higher

Recommendable Memory: 1GB or more
HDD: 80 GB or more
specifications
OS: Microsoft Windows XP SP3
(compatible with Windows Vista)
• SANYO cannot guarantee operations of all PCs satisfying the
above recommendable specifications.
• If other software is installed in a PC in which this software
was installed, information may be deleted due to malfunction.
Caution: SANYO guarantees the product under certain
warranty conditions. SANYO in no way shall be responsible for
any loss of content or damage to content.
• Appearance and specifications are subject to change without
notice.

Map Display
Conditions of biomedical devices can be
displayed on the map intelligibly. (A device
showing a warning is displayed in red.)

Channel List
The condition of each channel (measurement
item) is displayed together with the upper and
lower limit setting data.

Dimensions MTR-L03
[Unit : mm (inch)]
65 (2.6”)

28 (1.1”)

63 (2.5”)

58 (2.3”)

74 (2.9”)

Set Value Information
Set values of SANYO biomedical devices can
be changed through the network.
Graph Display
Condition change of a selected channel can be
displayed on a graph.

*The above function is only applicable to remotecontrollable devices.

Note:
All screen images shown in the catalog are composite images.
In the unlikely event of a mechanical failure, the contents of
the incubator and any recorded data cannot be guaranteed.

SANYO Electric Co., Ltd., Biomedical Division, Gunma is certified for:
Quality management system: ISO9001 / Medical devices quality management system: ISO13485 / Environmental management system: ISO14001
Distributed by:

SANYO Electric Co., Ltd.
Biomedical Division
http://biomedical.sanyo.com/
©2009 SANYO Printed in Japan 2009.7 MA

SHR147



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2009:07:10 13:53:12
Producer                        : Acrobat Distiller 4.05 for Macintosh
Author                          : wakafuji miharu
Creator                         : Adobe Illustrator(R) X
Title                           : mtr_5000_L03_print
Modify Date                     : 2009:07:10 13:53:39+09:00
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu