Data Acquisition System MTR-5000 MTR-L03 Monitors operating conditions by PC Stores operating records in the PC Informs a user of abnormality of device by e-mail Operating conditions can be set through LAN. Two-step/day operation is programmable. Cooled Incubator MIR-254 CO2 Incubator MCO-19AIC CO2 Incubator MCO-80IC Biomedical Freezer MDF-U537D Ultra-Low Freezer Ethernet (LAN) Interface MDF-U53V MTR-L03 Connection examples of a monitoring computer and SANYO biomedical devices to be monitored by LAN* *For connectable devices, consult with our company. *Those devices and the monitoring computer are connected using the special software, MTR-5000. *A personal computer is not included in this system. SANYO Data acquisition software MTR-5000 Data Acquisition System Features • Device-related information such as temperature, CO2 and O2 concentration, and operating condition can be integratedly monitored with one LANconnected personal computer. Items that can be monitored depend on the connected devices. • Operating records are stored in sequence in the PC. It is unnecessary to fill in paper records or to enter in a record book. It is easy to convert the data into a graph. Please note that there is a case in which data must be recorded on a paper. • Devices can be set up remotely from a distant point, which saves entering a clean room. When the operating setting can be changed through the network, it is impossible to change the operation setting on the panel of each device. Specifications • Setting the upper/lower limits will cause you to be informed of an abnormality by e-mail if the data is out of the range, and you will also be informed when the system recovers from the abnormality. In addition, the system can be set so that the device conditions will be informed at a designated time whether or not there is an abnormality. A mail account which can be connected to an SMTP-compatible mail server is required. Model Product name Exterior dimensions (W x D x H) Power supply • System access is protected by ID/Password. Main functions Ethernet (LAN) Interface 74 x 63 x 58mm (2.9” x 2.5” x 2.3”) DC5V (to be supplied from the attachment device) Output terminal RJ-45 twist pair cable 8-pin connector Compatible protocol TCP/IP *Only static IP (Impossible to use DHCP.) Note MTR-L03 is not equipped with sensors for temperature, etc. As information such as in-box temperature, etc., results measured at the sensors of the incubators and freezers are transmitted to the network. Model Product name MTR-5000 • Two-step/day operation to set up two different temperatures is programmable. For example, energy saving can be expected by changing to different setting temperatures for day and night operations. MTR-L03 SANYO Data acquisition software No. of devices to 32 devices at most (up to 100 ch) be monitored Devices to be monitored SANYO biomedical devices connected to MTR-L03 or MTR480 (RS232C or RS-485) Monitoring PC CPU: Core2DUO or higher Recommendable Memory: 1GB or more HDD: 80 GB or more specifications OS: Microsoft Windows XP SP3 (compatible with Windows Vista) • SANYO cannot guarantee operations of all PCs satisfying the above recommendable specifications. • If other software is installed in a PC in which this software was installed, information may be deleted due to malfunction. Caution: SANYO guarantees the product under certain warranty conditions. SANYO in no way shall be responsible for any loss of content or damage to content. • Appearance and specifications are subject to change without notice. Map Display Conditions of biomedical devices can be displayed on the map intelligibly. (A device showing a warning is displayed in red.) Channel List The condition of each channel (measurement item) is displayed together with the upper and lower limit setting data. Dimensions MTR-L03 [Unit : mm (inch)] 65 (2.6”) 28 (1.1”) 63 (2.5”) 58 (2.3”) 74 (2.9”) Set Value Information Set values of SANYO biomedical devices can be changed through the network. Graph Display Condition change of a selected channel can be displayed on a graph. *The above function is only applicable to remotecontrollable devices. Note: All screen images shown in the catalog are composite images. In the unlikely event of a mechanical failure, the contents of the incubator and any recorded data cannot be guaranteed. SANYO Electric Co., Ltd., Biomedical Division, Gunma is certified for: Quality management system: ISO9001 / Medical devices quality management system: ISO13485 / Environmental management system: ISO14001 Distributed by: SANYO Electric Co., Ltd. Biomedical Division http://biomedical.sanyo.com/ ©2009 SANYO Printed in Japan 2009.7 MA SHR147
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2009:07:10 13:53:12 Producer : Acrobat Distiller 4.05 for Macintosh Author : wakafuji miharu Creator : Adobe Illustrator(R) X Title : mtr_5000_L03_print Modify Date : 2009:07:10 13:53:39+09:00 Page Count : 2EXIF Metadata provided by EXIF.tools