Sargent A6427H 8893 Exit Device Inactive Trim Installation Instructions
User Manual: Sargent 8893 Exit Device Inactive Trim Installation Instructions Instruction Sheets
Open the PDF directly: View PDF .
Page Count: 1
INSTALLATION INSTRUCTIONS
8893 Exit Device Inactive Trim
FOR ASSISTANCE CONTACT SARGENT AT 800-727-5477 or www.sargentlock.com
BEFORE STARTING
• Door should be fitted and hung
• Mullion should be installed if used
• Available stock lengths
Length E – 32" Door. No cut-off required.
Can be cut to fit doors down to 24" wide*
Length F – 36" Door. No cut-off required.
Can be cut to fit doors down to 30" wide*
Length G – 48" Door. No cut-off required.
Can be cut to fit doors down to 36" wide*
*Flush doors only
A6427H
9/12
Copyright © 2009, 2012 Sargent Manufacturing Company,
an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
1
U.S. Patent No. 268003
Canadian Patent No. RD 1981
For 19-8893,
Touch Pad is Omitted
Mounting
Plate
End Cap
8893 Illustration
Edge of Door
Hinge side
of Door
Use (2) Round Head Screws (Do Not Tighten)
3"
41" From
Finished Floor
ATTACH MOUNTING PLATE TO DOOR
2IF CUTTING IS REQUIRED, DETERMINE CUT-OFF LENGTH X
BY SUBTRACTING 1-3/4" FROM LENGTH Y. MARK CUT-OFF POINT
ON BACK END OF RAIL ASSEMBLY.
For doors with stile, cut-off must leave 1/2" min. overlap with rail.
Cut-off length
X
Y3-7/16" Ref.
3
CUT-OFF AND DE BURR
LEVEL RAIL AND ATTACH SECOND MOUNTING PLATE
Level
Tighten all screws BOTH MOUNTING PLATES
TIGHT AGAINST INSERT
4ATTACH END CAPS TO MOUNTING
PLATES WITH COVER SCREWS
THRU-BOLTING APPLICATION
Use (2) round head
screws and grommet
nuts per mtg. plate
Slide rail under
mounting plate
1-3/4"