Sargent A7113E Instructions For Installing KP10G77 Line Bored Locks (Battery Operated Keypad) A7113

User Manual: Sargent Instructions for installing KP10G77 Line Bored Locks (Battery Operated Keypad) Instruction Sheets

Open the PDF directly: View PDF PDF.
Page Count: 26

DownloadSargent A7113E Instructions For Installing KP10G77 Line Bored Locks (Battery Operated Keypad) A7113
Open PDF In BrowserView PDF
Installation Instructions For
Keypad 10 Line Lock KP10G77

A7113E
8/08
Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

Table of Contents

Page

1

General Description ............................................................................1

2

Specifications .....................................................................................1

3

Parts Breakdown.............................................................................2-3

4

Features ..............................................................................................4

5

Installation Instructions................................................................5-12

6

Programming Instructions
English ...................................................................................12-15
Chain Programming ....................................................................16
Transaction Log ................................................................................17

8

Guide De Progammation (French) ...................................................18

8/14/08
12/15/07

Copyright © 2005, 2007,2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
© SARGENTinManufacturing
Company
2005,
2007.
All rights
reserved.
Reproduction
whole or in part without
the express
written
permission
of Sargent
Manufacturing Company is prohibited.

7

800-810-WIRE (9473) • www.sargentlock.com • A7113E

Keypad 10 Line Lock

1 General Description
The SARGENT Keypad 10 Line Lock is designed for areas which require authorized entry. It is a
self-contained microprocessor-controlled keypad with non volatile solid-state memory. The keypad will
hold a total of 100 different User Codes. User Codes “01” and “03” are utilized for Master Code and
Supervisory Code, respectively. All programming is done at the keypad, with over 1,100,000 possible
user combinations.
This lock is operated by four (4) “C” batteries with a life span of approximately 50,000 cycles.
A portable infrared printer (52-2069) may be used to download user information.

2 Specifications

A7113E • 800-810-WIRE (9473) • www.sargentlock.com

1

8/14/08

Copyright © 2005, 2007,2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

• Latch bolt - 1/2" standard
3/4" available (41-prefix)
• Deadlocking latch
• Outside lever controlled by keypad or key retracts latch bolt
• Inside lever retracts latch
• Locks furnished for 1-3/4" doors only
• U.L. Listed

Keypad 10 Line Lock

8/14/08
12/15/07

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
© SARGENTinManufacturing
Company
2005,
2007.
All rights
reserved.
Reproduction
whole or in part without
the express
written
permission
of SARGENT
Manufacturing is prohibited.

3 Parts Breakdown
ITEM
1

PART NUMBER
*10-0523
*10-2204
*10-0503
*10-0547
*10-0536
*10-2247
*10-0514
*10-0558

2
2A
4
5
6
6A
7
7A
9
9A
10
10A
11
12
12A
13
14
15
15A
15B
16
17
17A
17B
17C
18
18A

*10-0790
*10-0798
10-0792
10-3048
01-9170
10-0802
01-4388
82-0443
*10-2875
52-2400
45-1340
52-0069
01-0297
*52-2340
52-2299
01-1500
52-0033
10-2642
10-2643
10-2644
10-3049
10-0019
13-3613
13-3614
13-3713
10-0312
10-0313

19
20

13-3266
*10-2251
*10-2205
*10-0502
*10-0546
*10-0525
*10-2206
*10-0503
*10-0547
*10-0535
*10-2246
*10-0513
*10-0557

21
22
22A
22B
22C
23
24
24A
25
26
27
28
28A
29
30

*10-2000
10-2053
*10-2058
*10-2634
01-4414
*08-0312
*08-0066
*10-2052
*10-2070
52-2300
08-0055
01-1157
01-9063
01-1119
10-0043

DESCRIPTION
“B” Inside lever/regular and 30“J” Inside lever/regular and 30“L” Inside lever/regular and 30“P” Inside lever/regular and 30“B” Inside lever/75 handicap warning
“J” Inside lever/75 handicap warning
“L” Inside lever /75 handicap warning
“P” Inside lever/75 handicap warning
See SARGENT web page for Costal Series Levers.
Rose scalp "G"
Rose scalp "L"
Spacer bushing
Inside rose spring assembly (not finished)
Through-bolt screws
Plastic screw holder
8 X 1 SELF TAP SCREW
Turn lever cover plate, plastic -black. not shown
Inside escutcheon assembly
Controller/circuit board assembly only
Flat head screw (security)
Battery cover only
SOCKET ALLEN SAFETY KEY
Outside escutcheon & keypad
Keypad assembly only
SELF TAP SCREW TYPE "AB"
Fire stop plate and screws
77 Lockbody (std, 10, 21, 23, 30, SC, SE, VA & VS prefixes only)
77 Lockbody (60, 63, 64 prefixes only)
77 Lockbody (70, 72, 65-73, 65-73P lockbody)
Outside rose spring assembly (not finished)
Cylinder spacer
Schlage (SC) cylinder (provide keying details)
Schlage (SE) cylinder (provide keying details)
Cylinder (10-Signature)
Cylinder retainer
Cylinder retainer for removable core,
Interchangeable core & Keso
Cylinder (standard) provide keying details
“B” Lever outside standard cylinder
“J” Lever outside standard cylinder
“L” Lever outside standard cylinder
“P” Lever outside standard cylinder
“B” Outside lever/30-competitive cylinder
“J” Outside lever/30-competitive cylinder
“L” Outside lever/30-competitive cylinder
“P” Outside lever/30-competitive cylinder
“B” Outside lever/standard cylinder 76 handicap warning
“J” Outside lever/standard cylinder 76 handicap warning
“L” Outside lever/standard cylinder 76 handicap warning
“P” Outside lever/standard cylinder 76 handicap warning
See SARGENT web page for Costal Series Levers.
Key (provided with cylinder)
2-3/4" Backset latch (standard)
3-3/4" Backset latch (23 prefix)
5" Backset latch (25 prefix)
3/4" Throw (41 prefix)
Screw for standard front and strike
#800 Strike
#808 Strike (28-prefix)
Screw pack- standard (screws (latch, strike, #3) & push pin tool)
Screw pack- 28- prefix (screws (front, strike, #3) &push pin tool)
Screw pack (includes #’s 7, 11, 13, 14, 28, 28A, 29)
Strike Box- standard
8-32unc-2ax 1 1/4
WASHER
PH FL HD 8-32 X 1 1/2
Lever Retainer Push Pin, Not Shown

*Specify Finish

2

800-810-WIRE (9473) • www.sargentlock.com • A7113E

NO. REQ’D
1
1
1
1
1
1
1
1
2
2
2
1
2
2
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
A/R
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1

A7113E • 800-810-WIRE (9473) • www.sargentlock.com

3

8/14/08

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

Keypad 10 Line Lock

Parts Breakdown (Continued)

Keypad 10 Line Lock

4 Features
KP10G77
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

Non volatile memory
Motor driven, battery operated cylindrical lock
Battery operated with 4 each “C” Alkaline Batteries
Low battery alert–4 chirps after code entry
Option Code available to sound horn every time keypad is pressed
External remote “request to exit” connector
External battery input connector included to power unit in event of battery failure
100 users total: one Master Code, one Supervisory Code, with the rest being standard codes,
passage codes, or one time only codes
All programming done at keypad
Operates utilizing any two to six digits per code. Digits may be repeated and codes may start
with zero
Minimum 40,000 cycles per set of batteries
Cylinder override provided
Entry of three wrong User Codes disables all codes for ten seconds. Green LED flashes
Piezo horn can be heard with each keystroke or turned off by Master or Supervisory Code
Last 15 transactions can be output to portable printer via infrared link

Keypad

8/14/08
12/15/07

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
© SARGENTinManufacturing
Company
2005,
2007.
All rights
reserved.
Reproduction
whole or in part without
the express
written
permission
of SARGENT
Manufacturing is prohibited.

•
•
•
•
•

Made of ultraviolet stable material
LED’s indicate valid or invalid entries
Green LED indicates unlocked. Yellow LED indicates unit is in programming mode
Flashing green and yellow LED’s indicate lock in passage mode
Infrared LED for transaction output. Indicates last 15 valid codes

Items included in your KP10G77 Keypad Cylindrical Lock:
• Outside Escutcheon with Keypad
• Motorized Cylindrical Lock with cylinder
• Inside escutcheon with circuit board and battery pack
• Batteries (4 “C”)
• Tools

4

800-810-WIRE (9473) • www.sargentlock.com • A7113E

Keypad 10 Line Lock

5 Installation Instructions
Step #1 Verify Hand and Bevel of Door
Stand on outside/locked side of the door when determining the door hand

Left Hand

Left
hand
Hinges
Left.
hinges
left
Open inward.
open
“LH” inward
LH

Left Hand
Left hand
Reverse
Bevel
reverse
Hinges Left.bevel
hinges
left
Open
Outward
open outward
“LHRB”

Right Hand

Right
Hingeshand
Right
hinges
right
Open Inward.
open
“RH” inward
RH

LHRB

Right Hand
Right hand
Reverse
Bevel
reverse
bevel
Hinges
Right.
hinges
right
Open
Outward.
open outward
“RHRB”

RHRB

Step #2 Door Preparation

Outside of
door
Wood Door Preparation
A7113E • 800-810-WIRE (9473) • www.sargentlock.com

5

8/14/08

Inside of
door

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

Prepare door according to appropriate template (see website www.sargentlock.com):
• For metal door template, see 4486 and 4494
• For wood door template, see A7332 (scale paper template ships with product) and 4375-1
• Prior to installation, all holes must be free of burrs, debris and sharp edges
• If doors are not properly reinforced per ANSI115.2, commercially available reinforcements
should be installed

Keypad 10 Line Lock
Step #3 Frame Preparation for Strike

Step #4 Latch and Fire Stop Plate Installation
1. Install latch with beveled bolt facing the strike
2. Attach with two screws, but DO NOT tighten completely at this time
3. Attach Fire Stop Plate with two screws
Note: Required for all Fire Rated doors

8/14/08
12/15/07

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
© SARGENTinManufacturing
Company
2005,
2007.
All rights
reserved.
Reproduction
whole or in part without
the express
written
permission
of SARGENT
Manufacturing is prohibited.

Fire Rated Doors– Install Fire Stop Plate
(P/N 52-0033) as shown below

Important: Latch bevel must match door
bevel and deadlocking latch must stop on
strike when door is closed

6

800-810-WIRE (9473) • www.sargentlock.com • A7113E

Non Fire Rated Exterior Doors–
Install Weather Conduit (P/N 52-2847)
as shown below

Keypad 10 Line Lock
Step #5 Lock Installation

Lock Preset to:
• Through-bolt location– 12 & 6 o'clock
• Door thickness– 1-3/4" thick- see below for other door conditions
Adjustment for different through-bolt and door thickness:
• Remove outside lever (usually keyed), scalp and spacer bushing
• Rotate mounting plate to either align with through-bolt holes in door,
or adjust for proper door thicknesses (see markings on through-bolt)
• Reinstall spacer bushing (to align with back of lever) scalp and lever
1-3/4" thick door
2" thick door

Through-bolt
holes
Spacer bushing

Rotate to match
through-bolt holes in door

For wood
door only

2

Inside
of door
Screws partially
tightened

IMPORTANT:
Door must remain open
during installation.
Use door stop.

IMPORTANT:
Lockbody
must be
centered in
the door.

3

A7113E • 800-810-WIRE (9473) • www.sargentlock.com

7

8/14/08

1

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

1. Feed wires into the lock body hole from outside of door
2. Install lock body into cross-bore hole from outside of the door (locked side)
3. Lock body must engage both the latch unit prongs and tail piece (as shown)

Keypad 10 Line Lock
Step #6 Securing the Lock to Door
1A. If wood door, feed wires up through
the routed channel as shown
1B. If metal door, feed wire connector within the
door core and out hole on inside of door
2. Attach inside rose assembly and spacer
bushing and secure with screws shown

Step #7 Installation of Outside Escutcheon

8/14/08
12/15/07

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
© SARGENTinManufacturing
Company
2005,
2007.
All rights
reserved.
Reproduction
whole or in part without
the express
written
permission
of SARGENT
Manufacturing is prohibited.

• From the outside of the door,
feed keypad wires through fire
stop plate and to the inside of
the door. Lift plate cover if needed.
• IMPORTANT – Fire stop
plate cover must lay flat
before installing the keypad
to avoid interference

8

800-810-WIRE (9473) • www.sargentlock.com • A7113E

Keypad 10 Line Lock
Step #8 – Security of Outside Escutcheon
• From the inside of the door, use
the #8-32 x 1 1/4” round head
screw with the flat washer to
attach the escutcheon thru the
lower lug
• Straighten escutcheon and tighten
the #8-32 round head screw

Step #9 – Installation of Inside Escutcheon
• Plug the smaller lockbody
wires into the inside
escutcheon. Access holes
vary based on wood or
metal door application

IMPORTANT: Both wire
plug connectors go on
only one way. Do not
offset the connectors.
If not seated, keypad
will not function properly

A7113E • 800-810-WIRE (9473) • www.sargentlock.com

9

8/14/08

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

• Plug keypad ribbon
cable connector into
inside escutcheon

Keypad 10 Line Lock
Step #10 Securing of Inside Escutcheon
• Remove black plastic battery cover with security hex wrench (provided)
• Carefully tuck the wire into the routed groove in wood door. The remainder can fit within
bottom portion of escutcheon. Make certain that wires are not pinched by obstructions in escutcheon
• Place inside escutcheon flat against the door
• Secure inside escutcheon with one flat head screw thru interior of inside escutcheon and into
post of exterior escutcheon
• Secure bottom of escutcheon with flat head screw and ferrule

8/14/08
12/15/07

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
© SARGENTinManufacturing
Company
2005,
2007.
All rights
reserved.
Reproduction
whole or in part without
the express
written
permission
of SARGENT
Manufacturing is prohibited.

Step #11 Test Lockset

• Rotate inside lever
to test for latch
bolt retraction
• Place key into
cylinder and rotate
key for latch
bolt retraction
• Tighten latch
bolt screws on
edge of door
• Test keypad
operation per
manual's
instructions

10

800-810-WIRE (9473) • www.sargentlock.com • A7113E

Keypad 10 Line Lock
Step #12 – Battery Installation
• Place (4) C batteries into the compartment as indicated inside escutcheon
• Attach battery cover to inside escutcheon and secure with #8-32 x 3/8" security screw
DO NOT OVER TIGHTEN

How to Remove Outside Lever Only

11

8/14/08

A7113E • 800-810-WIRE (9473) • www.sargentlock.com

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

1.Insert key, rotate 45° clockwise and hold
2.Depress lever retainer with push pin tool (provided)

Keypad 10 Line Lock

How to Change Cylinder (if required)
1. With outside lever in handuse standard pliers; pull out
cylinder retainer
2. Remove key and cylinder from lever
3. Insert new cylinder
4. Secure by pressing cylinder retainer
flush with shelf*
* NOT SHOWN

Cylinder
retainer
Cylinder
spacer

Key
Outside
lever

Cylinder

Washers
(only 30- prefix)

6 Programming Instructions
The 10 Line Keypad Lock can support 100 users. Each user is assigned a User Number in addition to
the code used for entry.

8/14/08
12/15/07

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
© SARGENTinManufacturing
Company
2005,
2007.
All rights
reserved.
Reproduction
whole or in part without
the express
written
permission
of SARGENT
Manufacturing is prohibited.

Example:

12

USER
TYPE

USER
NUMBER

USER CODE*
(2-6 DIGITS)

Master
Supervisor

01
03

1 2 3 4
3 0 3 0 3 0

Standard

04-97

Special Factory
10 Sec. Time Preset

98
99

800-810-WIRE (9473) • www.sargentlock.com • A7113E

2 6 5
1 3 6 8

Keypad 10 Line Lock

6 Programming Instructions (Continued)
This Keypad 10 Line Lock has 99 User Codes available for programming purposes.
• The Master Code is always User “01”. The Master Code assigns the Emergency and Supervisory Codes.
It is also used for programming. Users are deleted through the Master Programming Code only.
• The Emergency Code is always User “02”. The Emergency Code has an unlock time of 10 seconds.
• The Supervisory Code is always User “03”. The Supervisory Code allows temporary lockout of selected
users, changes duration of unlock time, requests infrared interrogation output, and may add additional
User Codes.
• The first User Code will be User “04” or higher. User numbers do not have to be used or entered
sequentially.
• User codes “98” and “99” have a factory-set unlock time of ten seconds. This allows a handicapped person
extra time which would not be required by other users.

To Begin Programming:
The Keypad 10 Line Lock is preset at the factory with Master Code “1234”. Entering 1234 * will unlock
the lock allowing the lever handle to retract the latchbolt.

Initial Set-Up Procedures:
• The following are typical procedures to follow when setting up your KP10G77 Keypad.
• If a mistake is made during any of procedures, depress the “*” several times until the yellow LED goes out.
• If no keystroke is made in a 30 sec. time frame, the programming up to that point will default and you will
have to start over.

All of the following procedures start with 99#.
If after the last “*” is depressed, the yellow LED does not go out, depress “*” once more.

Change Master Code:

To Enter the Emergency Code: (Unlock Duration is Factory Set at 10 Sec)
• Master Code* (Yellow LED Begins to Blink Slowly)
• 50# 1# 02# Emergency Code* (Yellow LED Blinks Quickly)
• Emergency Code* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out)"

To Enter the Supervisory Code:
• Master Code* (Yellow LED Begins to Blink Slowly)
• 50# 1# 03# Supervisory Code* (Yellow LED Blinks Quickly)
• Supervisory Code* (Yellow LED Blinks Slowly) *(Yellow LED Goes Out)

A7113E • 800-810-WIRE (9473) • www.sargentlock.com

13

8/14/08

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

• 1234* (Yellow LED Begins to Blink Slowly) This example uses the Factory Default Master Code
• 50# 1# 01# New Master Code* (Yellow LED Blinks Quickly)
• New Master Code* (Yellow LED Blinks Slowly) *(Yellow LED Goes Out)

Keypad 10 Line Lock
All of the following procedures start with 99# (continued).
If after the last “*” is depressed, the yellow LED does not go out, depress “*” once more.

To Enter a User Code:
• Supervisory or Master Code* (Yellow LED Begins to Blink Slowly)
• 50# 1# User Number (04-97)# User Code* (Yellow LED Blinks Quickly)
• User Code* (Yellow LED Blinks Slowly)* (Yellow LED Goes Out)
To Enter a Passage (Maintained Mode) Code: When Passage Mode is used, the same User Code
must be used to Re-lock the Lock.
• Supervisory or Master Code* (Yellow LED Begins to Blink Slowly)
• 50# 2# User Number (04-97)# User Code* (Yellow LED Blinks Quickly)
• User Code* (Yellow LED Blinks Slowly)* (Yellow LED Goes Out)
To Enter a One Time User Code:
• Supervisory or Master Code* (Yellow LED Begins to Blink Slowly)
• 50# 3# User Number# User Code* (Yellow LED Blinks Quickly)
• User Code* (Yellow LED Blinks Slowly) * (Yellow LED Goes Out)

8/14/08
12/15/07

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
© SARGENTinManufacturing
Company
2005,
2007.
All rights
reserved.
Reproduction
whole or in part without
the express
written
permission
of SARGENT
Manufacturing is prohibited.

To Deactivate “Beep” With the Depression of Each Key:
• Supervisory or Master Code* (Yellow LED Begins to Blink Slowly)
• 30# 0# 0# (Yellow LED Continues to Blink Slowly)
• * (Yellow LED Blinks Quickly)
• * (No Beep on Depression and Yellow LED Blinks Slowly)
• * (No Beep on Depression and Yellow LED Goes Out)
To Reactivate “Beep” With the Depression of Each Key:
• Supervisory or Master Code* (Yellow LED Begins to Blink Slowly)
• 30# 0# 1# (Yellow LED Continues to Blink Slowly)
• * (Yellow LED Blinks Quickly)
• * (Beep on Depression and Yellow LED Blinks Slowly)
• * (Beep on Depression and Yellow LED Goes Out)
To Clear the Entire Memory:
• Master Code* (Yellow LED Begins to Blink Slowly)
• 46# 00000# 00000# (Yellow LED Continues to Blink Slowly)
• * (Yellow LED Blinks Quickly)
• * (No Beep on Depression and Yellow LED Goes Out)
• PAUSE, Yellow LED Begins to Blink Again
• * (Yellow LED Goes Out)
Note: This Deletes ALL Codes, including Master, Emergency and Supervisory. The Master Code is set back to
1234, Door Number to 0001 and Unlock time 5 Sec. If the Master Code is not known, Factory Assistance will be
required to clear the memory. 1-800-810-WIRE.

To Program Door Numbers into Keypad:
• Master Code* (Yellow LED Begins to Blink Slowly)
• 43# 0# Door Number# (must be four digits) (Yellow LED Blinks Slowly)
• * (Yellow LED Begins to Blink Quickly)
• * (Yellow LED Blink Slowly)
• * (Yellow LED Goes Out)

14

800-810-WIRE (9473) • www.sargentlock.com • A7113E

Keypad 10 Line Lock
Sargent also offers a Data Transfer Device (DTD) To Interrogate the lock.
Go to WWW.SARGENTLOCK.COM for information.

All of the following procedures start with 99# (continued).
If after the last “*” is depressed, the yellow LED does not go out,
depress “*” once more.

To Interrogate Transaction Log:
•
•
•
•

Supervisory or Master Code* (Yellow LED Begins to Blink Slowly)
70# 0# 0# (Yellow LED Blinks Slowly)
* (Yellow LED Begins to Blink Quickly)
* (Yellow LED Goes Out)

Hold an infrared printer up to the
red infrared LED (as shown). An
HP82240B Infrared Printer can
be used to download information
from the keypad to a printout.

For additional information, see “Transaction Log”.
Door #5666
Seq
User
Trans
Note: Seq. # 1 is the
programming request
1
001
003
Door
to output the entries.
2
003
001
Number
Sequence numbers
3
003
001
2-6 are the actual
entries.
4
020
001
5
003
001
Transaction
Number

User
Number

Transaction
type

To Disable / Enable a User Number:
• Supervisory or Master Code* (Yellow LED Begins to Blink Slowly)
• 56# 0# = Enable, 1# = Disable, User Number# (04-99) (Yellow LED Blinks Slowly)
• * (Yellow LED Begins to Blink Quickly)
• * (Yellow LED Blinks Slowly)
• * (Yellow LED Goes Out)
To Set Unlock Time:
• Master Code* (Yellow LED Begins to Blink Slowly)
• 85# Time Duration# (01-99 Sec) 0# (Yellow LED Blinks Slowly)
• * (Yellow LED Begins to Blink Quickly)
• * (Yellow LED Blinks Slowly)
• * (Yellow LED Goes Out)
Note: The Unlock Time is Adjustable for Momentary Operation. A 5 second unlock time is recommended to
extend battery life. Once the unlock time is entered, it is the same for ALL users except 02, 98 and 99 which are
factory set for 10 seconds.
A7113E • 800-810-WIRE (9473) • www.sargentlock.com

15

8/14/08

To Delete a User Number:
• Master Code* (Yellow LED Begins to Blink Slowly)
• User Number# (Yellow LED Blinks Slowly)
• * (Yellow LED Begins to Blink Quickly)
• * (Yellow LED Blinks Slowly)
• * (Yellow LED Goes Out)

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

To Reset / Clear Transaction Log:
• Supervisory or Master Code* (Yellow LED Begins to Blink Slowly)
• 76# 00000# 00000# (Yellow LED Blinks Slowly)
• * (Yellow LED Begins to Blink Quickly)
• * (Yellow LED Goes Out)

Keypad 10 Line Lock
Chain Programming
When programming multiple User Numbers and Codes into the
10 Line Keypad Lock, it is not necessary to leave and re-enter the
programming mode (50) for each entry. Multiple entries may be chained
together and the three different types of user codes (Standard, Passage
and One Time) may be mixed.
The format to be used is as follows where:
“T” is the Type of user code with “1” Standard, “2” Passage and “3” One Time.
“UN_” is User Number (04-99)
“UC_” is User Code (2 to 6 digits) which correlates with the User Number 99# Master or Supervisor
Code* 50# Type# User Number a# User Code a*
User Code a* T# UNb# UCb* UCb* T# UNc# UCc* UCc* ...... T# UN_# UC_* UC_**
An example with four user codes is shown below:

8/14/08
12/15/07

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
© SARGENTinManufacturing
Company
2005,
2007.
All rights
reserved.
Reproduction
whole or in part without
the express
written
permission
of SARGENT
Manufacturing is prohibited.

Type
1
3
2
1

User Number
05
12
08
50

User Code
875
2226
5444
3367

Using Master Code 4732 and above information, the lock would be programmed as follows:
99# 4732* 50# 1# 05# 875* 875* 3# 12# 2226* 2226* 2# 08# 5444* 5444* 1# 50# 3367*
3367**
If all user codes are the same type, it is not necessary to enter the type number with each
entry. The type number has to be entered with the first user code only.
The format now simplifies to:
99# Master or Supervisor Code* 50# Type# User Number a# User code a* User Code a*
UNb# UCb* UCb* UNc# UCc* UCc*....... UN_# UC_* UC_**
An example with three user codes is shown below:
Type
1
1
1

User Number
07
15
91

User Code
77
67832
7568

Using Master Code 45988 and above information, the lock would be programmed as follows:
99# 45988* 50# 1# 07# 77* 77* 15# 67832* 67832* 91# 7568* 7568**
To chain the User Number delete procedure:
99# Master Code* User Number a#** UNb#** UNc#**....... UN_#****
Using the information from the above example:
99# 45988* 07#** 15#** 91#****

16

800-810-WIRE (9473) • www.sargentlock.com • A7113E

Keypad 10 Line Lock

To output the last 15 entries, enter 99 # Supervisory or Master Code * 70 # 0 # 0 # **.
Note: Seq. # 1 is the
programming request to output
the entries. Sequence numbers
2-6 are the actual entries.

7 Transaction Log

Door #5666
Seq
User
Trans
1
001
003
2
003
001
3
003
001
4
020
001
5
003
001

Door Number
• 4 Digits
• Up to 9999 different doors, assigned by user

Door
Number

Transaction Number
• Single digit - 1-6
• Latest transaction - 1
• Oldest transaction - 6
Transaction
Number

User Number

User
Number

Transaction
type

• Three digits - 001 through 099
• User numbers assigned at time of programming
Hold an infrared printer up to the
red infrared LED (as shown). An
HP82240B Infrared Printer can
be used to download information
from the keypad to a printout.

• 001 =Access granted
• 003 = Log printed
Optional Equipment

ElectroLynx®
As part of their promise to provide innovative, fast and effective high
security solutions to their customers, ASSA ABLOY Group companies
offer ElectroLynx®, a universal quick-connect system that simplifies the
electrification of the door opening.
ElectroLynx® is a registered trademark of ASSA ABLOY Inc.

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

• Printer Paper (6 Rolls) - 52-0034 used for infrared printers
• Auxiliary Power Unit (APU) 52-2065 - used to unlock unit if
batteries are too weak and cylinder is not used.
• Infrared Printer - 52-2069 - used to download the user and
transaction type.
• Remote Unlocking - 52-2071 - used for remote unlocking
of keypad 10 Line Lock. When remote unlocking feature is
used, the latchbolt can be retracted by turning the lever
handle. Use a QC2A Hinge.

Remote
unlocking
connector
placement
TB-2

A7113E • 800-810-WIRE (9473) • www.sargentlock.com

17

8/14/08

Transaction Types

Keypad 10 Line Lock

Serrure à clavier KP10G77
Guide de programmation
La serrure à clavier KP10G77 peut accomoder 100 utilisateurs. On doit assigner à chacun un numéro
d’utilisateur, en plus de son code d’entrée.

Example:

Type d’usager

Numéro d’usager

Code d’usager
(2 à 6 chiffres)

Maître
Urgence
Superviseur

01
02
03

1 2 3 4
2 2 2 2 2
3 0 3 0 3 0

Ordinaire

04 à 97

Spécial usine
10 secondes

98
99

2 6 5
1 3 6 8

99 codes d’utilisateurs disponibles à la programmation
• Le code maître est toujours l’utilisateur programmation. Les utilisateurs sont
• Le code d’urgence est toujours l’utilisateur temps de déverrouillage de 10 secondes.
• Le code superviseur est toujours modification du temps de déverrouillage,
• Le premier code d’utilisateur sera

8/14/08

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

• Les codes ‘’98’’ et ‘’99’’ établis en les personnes handicapées.

18

800-810-WIRE (9473) • www.sargentlock.com • A7113E

Keypad 10 Line Lock
Pour commencer :
Le code maître établi en usine est “1234’’. Appuyer sur 1234* déverrouille la serrure, permettant au
levier de retirer le pêne.

Codification initiale :
Dans une séquence typique de programmation, le voyant jaune clignotera doucement après l’entrée
du code maître ou superviseur suivi de “ * ”. Il continuera jusqu’à l’entrée du nouveau code suivi de
“ * ”. Il clignotera ensuite rapidement jusqu’à l’entrée de “ * ”. Si le voyant reste allumé, sans clignoter,
durant la programmation, il y a eu une erreur de programmation et la séquence doit être
recommancée.

Pour changer le code maître
Entrer : 99 # 1234 * 50 # 1 # 01 # Nouveau code maître suivi de * Nouveau code maître suivi de * *

Pour entrer le code d’urgence :
Entrer : 99 # Code maître suivi de * 50 # 1 # 02 # Code d’urgence * Code d’urgence * *
Remarque : La durée de déverrouillage est réglée en usine à 10 secondes.

Pour entrer le code superviseur :
Entrer : 99 # Code maître suivi de * 50 # 1 # 02 # Code d’urgence * Code d’urgence * *
Entrer : 99 # Code maître suivi de * 50 # 1 # 03 # Code superviseur suivi de * Code superviseur suivi de * *

Pour entrer un code passage (fonction maintenue) :
Entrer : 99 # Code maître ou superviseur suivi de * 50 # 2 # Numéro d’utilisateur (entre 04 et 97) suivi
du # et code d’utilisateur suivi de * Code d’utilisateur suivi de * *
Le même code devra être utilisé pour reverrouiller la serrure.

A7113E • 800-810-WIRE (9473) • www.sargentlock.com

19

8/14/08

Entrer : 99 # Code maître ou superviseur suivi de * 50 # 1 # Code d’utilisateur (entre 04 et 97) suivi du
# et du code d’utilisateur suivi de * Code d’utilisateur suivi de *

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

Pour entrer un code d’utilisateur :

Keypad 10 Line Lock
Pour entrer un code servant une fois seulement :
Entrer : 99 # Code maître ou superviseur suivi de * 50 # 3 # Numéro
d’utilisateur suivi du # et code d’utilisateur suivi de * Code d’utilisateur suivi
de * *

Pour annuler la tonalité entendue en appuyant sur les touches :
Entrer : 99 # Code maître ou superviseur suivi de * 30 # 0 # 0 # * * *

Pour remettre la tonalité entendue en appuyant sur les touches :
Entrer : 99 # Code maître ou superviseur suivi de * 30 # 0 # 1 # * * *

Pour effacer entièrement la mémoire :
Entrer : 99 # Code maître suivi de * 46 # 00000 # 00000 # * *  *

Remarque : Ceci annule tous les codes, incluant les codes maître et superviseur.
Le code maître redevient 1234, le numéro de porte 0001 et le temps de déverrouillage 5 secondes.

Pour programmer les numéros de porte :
Entrer : 99 # Code maître suivi de * 43 # 0 # Numéro de porte (doit être quatre chiffres) suivi de # * * *

Pour lire le rapport des activités :
Entrer : 99 # Code maître ou superviseur suivi de * 70 # 0 # 0 # * *

8/14/08

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

Pour effacer le rapport des activités :
Entrer : 99 # Code maître suivi de * 76 # 00000 # 00000 # * *

Remarque : Après chaque programmation, le voyant jaune devrait arrêter de clignoter.
S’il clignote toujours après la dernière * , appuyer de nouveau sur *.

Pour annuler un numéro d’utilisateur :
Entrer : 99 # Code maître suivi de * Numéro d’utilisateur suivi de # * * * *

Pour annuler un numéro d’utilisateur :
Entrer : 99 # Code maître suivi de * Numéro d’utilisateur suivi de # * * * *

Pour invalider et réactiver un numéro d’utilisateur :
Entrer : 99 # Code maître ou superviseur suivi de * 56 # choix # numéro d’utilisateur (04 à 99) suivi de # * *
A noter : choix 0 = réactive, 1 = invalide,

20

800-810-WIRE (9473) • www.sargentlock.com • A7113E

Keypad 10 Line Lock

Pour fixer le temps de déverrouillage :
Entrer : 99 # Code maître suivi de * 85 # Durée suivie de # 0 # * * *
Remarque : Le temps de déverrouillage est réglable entre 01 et 99 secondes. On recommande 5
secondes pour prolonger la durée des piles. Le temps sera le même pour TOUS les utilisateurs, sauf
02, 98 et 99 qui sont pré-réglés en usine à 10 secondes.

Programmation en chaîne
Pour programmer des numéros et des codes d’utilisateurs multiples, il n’est pas nécessaire de quitter
le mode de programmation (50) entre chaque entrée. On peut entrer un après l’autre, en désordre, les
trois différents types de codes d’utilisateurs (ordinaire, passage et une fois).
Le format à suivre est le suivant :
‘’T’’ est le type de code d’usager, soit ‘’1’’ pour ordinaire, ‘’2’’ pour passage et ‘’3’’ pour une fois.
‘’UN_’’ est le numéro d’utilisateur (entre 04 et 99)
‘’UC_’’ est le code d’utilisateur (de 2 à 6 chiffres) qui correspond au numéro d’utilisateur.
99# Code maître ou superviseur * 50# Type# Numéro d’utilisateur a# Code d’utilisateur a *
Code d’utilisateur a * T# Unb# Ucb * Ucb * T# Unc# Ucc * Ucc * ..... T# UN_# UC_ * UC_ **
Ceci est un exemple de quatre codes d’utilisateurs :
Code d’utilisateur

1

05

875

3

12

2226

2

08

5444

1

50

3367

En utilisant le code maître 4732 et les renseignements ci-dessus, la programmation de la serrure serait
la suivante :
99# 4732* 50# 1# 05# 875* 875* 3# 12# 2226* 2226*
2# 08# 5444* 5444* 1# 50# 3367* 3367**

A7113E • 800-810-WIRE (9473) • www.sargentlock.com

21

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

Numéro d’utilisateur

8/14/08

Type

Keypad 10 Line Lock

Il n’est pas nécessaire d’entrer le numéro de type à chaque entrée si tout les codes d’utilisateurs sont
du même type. Le numéro de type doit être entré avec le premier code d’utilisateur seulement.
Le format sera donc simplifié:
99# Code maître ou superviseur* 50# Type# Numéro d’utilisateur a#
Code d’utilisateur a* Code d’utilisateur a* Unb# Ucb* Ucb* Unc#
Ucc* Ucc* ..... UN_# UC_* UC_**
Ceci est un exemple de trois codes d’utilisateurs :
Type

Numéro d’utilisateur

Code d’utilisateur

1

07

77

1

15

67832

1

91

7568

En utilisant le code maître 45988 et les renseignements ci-dessus, la programmation de la serrure sera
la suivante :
99# 45988* 50# 1# 07# 77* 77* 15# 67832* 67832* 91# 7568* 7568**
Pour annuler en chaîne les numéros d’usagers :
99# Code maître * Numéro d’utilisateur a#** Unb#** Unc#** ... UN_#****
En utilisant les renseignements de l’exemple ci-dessus :
99# 45988* 07#** 15#** 91#****

8/14/08

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

ATTENTION
Bien vérifier le branchement entre le clavier extérieur et la plaque du
côté intérieur de la porte. Toutes les broches doivent être bien en
place pour que le clavier fonctionne. Voir étape 6A du manuel
illustré.

22

800-810-WIRE (9473) • www.sargentlock.com • A7113E

Keypad 10 Line Lock

To output the last 15 entries, enter 99 # Supervisory or Master Code * 70 # 0 # 0 # **.
Note: Seq. # 1 is the
programming request to output
the entries. Sequence numbers
2-6 are the actual entries.

7 Transaction Log

Door #5666
Seq
User
Trans
1
001
003
2
003
001
3
003
001
4
020
001
5
003
001

Door Number
Door
Number

• 4 Digits
• Up to 9999 different doors, assigned by user
Transaction Number
• Single digit - 1-6
• Latest transaction - 1
• Oldest transaction - 6

Transaction
Number

User Number

User
Number

Transaction
type

• Three digits - 001 through 099
• User numbers assigned at time of programming
Hold an infrared printer up to the
red infrared LED (as shown). An
HP82240B Infrared Printer can
be used to download information
from the keypad to a printout.

• 001 =Access granted
• 003 = Log printed
Optional Equipment

Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.

• Printer Paper (6 Rolls) - 52-0034 used for infrared printers
• Auxiliary Power Unit (APU) 52-2065 - used to unlock unit if
batteries are too weak and cylinder is not used.
• Infrared Printer - 52-2069 - used to download the user and
transaction type.
• Remote Unlocking - 52-2071 - used for remote unlocking
of keypad 10 Line Lock. When remote unlocking feature is
used, the latchbolt can be retracted by turning the lever
handle.

Remote
unlocking
connector
placement

A7113E • 800-810-WIRE (9473) • www.sargentlock.com

23

8/14/08

Transaction Types

Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2005, 2007,2008, SARGENT Manufacturing, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is prohibited.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisfying end-user needs for security, safety and convenience.

A7113E-8/08



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Create Date                     : 2008:08:18 15:35:25Z
Creator Tool                    : QuarkXPress(R) 7.31
Modify Date                     : 2008:08:28 07:39:59-04:00
Metadata Date                   : 2008:08:28 07:39:59-04:00
Producer                        : QuarkXPress(R) 7.31
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
Format                          : application/pdf
Title                           : A7113E
Document ID                     : uuid:eddc3aa7-dd3f-404b-bcf1-8695f4434c23
Instance ID                     : uuid:92c0cff0-aa3e-4ae6-8d29-bd9070990605
Page Count                      : 26
Creator                         : QuarkXPress(R) 7.31
EXIF Metadata provided by EXIF.tools

Navigation menu