Schlage Electronics CO 100 User Guide 104210
User Manual: Schlage Electronics CO-100 User Guide Installation Manuals
Open the PDF directly: View PDF
.
Page Count: 12
| Download | |
| Open PDF In Browser | View PDF |
*P516-270* P516-270 CO-100 Offline lock user guide Instructions for CO-Series offline locks Para el idioma español, navegue hacia www.allegion.com/us. Pour la portion française, veuillez consulter le site www.allegion.com/us. Contents Overview............................................................................................................................3 Lock functions....................................................................................................................4 Getting started...................................................................................................................4 Construction access mode................................................................................................4 Credential types and functions..........................................................................................5 Important notes:.............................................................................................................5 PROGRAMMING credential..........................................................................................5 NORMAL USE credentials.............................................................................................6 TOGGLE credentials......................................................................................................6 FREEZE credentials......................................................................................................6 PASS THROUGH credentials........................................................................................7 OTHER programming....................................................................................................7 Error codes.......................................................................................................................8 Test lock operation.............................................................................................................8 Mechanical test..............................................................................................................8 Electronic test................................................................................................................8 Normal lock operation........................................................................................................8 Lock status reports............................................................................................................9 Reset to factory defaults..................................................................................................10 Batteries .........................................................................................................................10 To install or replace alkaline batteries..........................................................................10 Low battery indications................................................................................................ 11 Battery failure mode..................................................................................................... 11 LED reference.................................................................................................................. 11 Schlage button............................................................................................................. 11 Optional Inside Push Button (IPB)............................................................................... 11 Troubleshooting...............................................................................................................12 FCC Statements..............................................................................................................12 This product is compliant of UL 294 and ULC S319 standard. This product’s compliance would be invalidated through the use of any add-on, expansion, memory or other module that has not yet been evaluated for compatibility for use with this UL Listed product, in accordance with the requirements of the Standards UL 294 and ULC S319. This product has been evaluated for ULC-S319 Class I. 2 • Schlage • CO-100 user guide Overview The Schlage CO-100 is a keypad-only off-line electronic lock in the CO-Series product line. • This product is listed for UL 294 and ULC S319. • Two factory-configured functions are available: 1) Classroom/Storeroom, and 2) Office. • The lock is powered by four (4) AA batteries. See Batteries on page 10 for more information. • Outside lever is normally locked. • Inside lever always allows egress. Outside Schlage Button Keypad Outside Lever Keyway Inside Thumbturn Battery Compartment Optional Inside Push Button Inside Lever CO-100-CY CO-100-MS CO-100-MD CO-100-993 3 • Schlage • CO-100 user guide Lock functions The CO-100 lock is available in one of two functions: Office (50): Lockset is normally secure. Inside Push Button may be used to select passage or secured status. Classroom/Storeroom (70): Lockset is normally secure. Valid toggle credentials may be used to change to a passage or secure status. Getting started Follow these steps when setting up a new lock. 1. Install the lock. See the installation guide that came with the lock or visit www.allegion.com/us (see Support>Schlage Electronics>Electronic Locks Technical Library) for more information. 2. Test the lock for proper mechanical and electronic operation. See Test lock operation on page 8 for more information. 3. When ready to set up for normal use, enter a new programming code, then program the user credentials. See Manual programming instructions on page 5. 4. Familiarize yourself with the information in this guide. Save this user guide for future reference. Construction access mode Construction access mode is used to allow access before the lock has been programmed, and for testing purposes. Construction access mode is enabled by default. TIP If you press the default PIN code on a new lock and the code is not Offline locks with keypads have a default PIN of 13579 accepted, the lock has already and “#”, which can be used for installation, testing and been programmed. construction access. If the new PIN is not known, or to • To test, enter the default PIN (13579 and “ #”). put the lock back into construction • The Schlage button will blink and the lock will access mode, reset the lock to unlock. factory settings. See Reset to • The default PIN is automatically deleted when a factory defaults on page 10 for new programming credential is created. more information. 4 • Schlage • CO-100 user guide Credential types and functions Programming credential: A 5 digit code used only for lock programming. PIN credential: A 3-6 digit code entered on the keypad. Note: A unique credential must be used for each credential type described below (for example, a single credential may not be used for both normal use and toggle functions). Credential type Function Programming PIN Used only to program the lock. Does not unlock the lock. Normal use PIN Unlocks the lock momentarily after a credential is entered. Toggle PIN Freeze PIN Changes the state of the lock from locked (secured) to unlocked (unsecured), or vice versa, unless in a Freeze state. Freezes the lock in the current state. The lock remains frozen until any Freeze credential is entered again. (A pass-through credential will override a lock in frozen state as described below). Unlocks a lock momentarily, regardless of state. Pass-through PIN A valid Pass-through credential can unlock a door set to any secured lockout mode (e.g., Freeze, Privacy, Time Zones, Door Auto-Locks and Holidays). The door will relock after the specified relock time. Manual programming instructions Important notes: LL Wait for the Schlage button LEDs to stop flashing before continuing to the next step. LL Programming mode will time out if no entry is made in 20-25 seconds. Time out is indicated by three left and nine right red blinks of the Schlage button. LL An incorrect entry is indicated by a solid red left and blinking green right LED on the Schlage button. Refer to Error codes on page 12 to interpret error code patterns. LL A unique PIN must be used for each credential type (for example, a single PIN may not be used for both normal use and toggle functions). PROGRAMMING credential To complete this action: Create new Programming Code (PIN) Perform the following steps: Wait for 1 Enter (This is the default programming PIN) to stop flashing between each step! 2 Enter 3 4 Enter new 5 digit Reenter the new 5 Programming digit Programming code and code and Wait for right Wait for confirmation: green light. 2 right green blinks. Note: Programming codes such as 1-1-1-1-1 or 1-2-3-4-5 can be easily selected by non-authorized users and should not be used. 5 • Schlage • CO-100 user guide NORMAL USE credentials Note: Until a new Normal Use PIN is created, the default PIN is Perform the following steps: To complete this action: Wait for 1 Enter Create a Normal Use Programming PIN and PIN 2 Enter to stop flashing between each step! 3 4 5 Enter new For another Press 3-6 digit PIN, go again PIN and back to to finish step 3 6 Wait for confirmation: 2 right green blinks. TOGGLE credentials Perform the following steps: To complete this action: Create a Toggle PIN Wait for 1 Enter Programming PIN and 2 Enter to stop flashing between each step! 3 Enter 4 5 Enter new For another 3-6 digit PIN, go PIN and back to step 3 OR Wait for press right green again to light. finish 6 Wait for confirmation: 2 right green blinks. FREEZE credentials To complete this action: Create a Freeze PIN Perform the following steps: Wait for 1 Enter Programming PIN and 6 • Schlage • CO-100 user guide 2 Enter to stop flashing between each step! 3 Enter 4 5 6 Wait for For another PIN, go back confirmation: 2 right green to step 3 blinks. OR press Wait for again to right green finish light. Enter new 3-6 digit PIN and PASS THROUGH credentials Perform the following steps: To complete this action: Create a Pass Through PIN Wait for 1 Enter Programming PIN and to stop flashing between each step! 2 3 Enter Enter 4 5 Enter new 3-6 digit PIN and 6 Wait for For another PIN, go back confirmation: 2 right green to step 3 blinks. OR press Wait for again to right green finish light. OTHER programming To complete this action: Perform the following steps: Wait for 1 Enter Delete a PIN Programming PIN and to stop flashing between each step! 2 3 4 Enter Enter the PIN to be deleted and Enter Change PIN Programming length PIN and (Available Enter Enter Enter Change relock delay Programming PIN and period Enter Enter Each button press adds to the total delay time Example: + adds a 10 second delay Enter Enter Enter to disable beeper OR with firmware version 2.5.0 or higher.) Disable/ enable beeper Enter Programming PIN and To delete another PIN, go back to step 3 OR press again to finish Enter , , , OR for desired PIN length to enable beeper 5 Wait for confirmation: 2 right green blinks. Press again to finish Wait for confirmation: 2 right green blinks. Press again to finish Wait for confirmation: 2 right green blinks. Press again to finish Wait for confirmation: 2 right green blinks. 7 • Schlage • CO-100 user guide Error codes LL All error codes are indicated on the Schlage button by a solid red left LED, and a blinking green right LED. The number of green blinks indicates the error code. Red Green Left LED Right LED Error code functions have not been verified by Underwriters Laboratories Inc. Number of Error code description green blinks 1 Computer programming error (not complete). Too long programming/user code entered. 2 Programming code must be five (5) digits. User code length cannot exceed six (6) digits. 3 Memory full, too many codes. Delete some codes. 4 Programming code cannot be deleted, only changed. Programming code entries do not match. 5 Programming code not changed. 6 Invalid command. Invalid function code entered. 7 Code not found. Code too short. Programming code length must be five 8 (5) digits. User code minimum length is three (3) digits. 9 Not a unique code. 10 Manual programming not allowed. Test lock operation If you encounter problems while performing any of the following tests, review the installation guide and correct any problems. Mechanical test 1. Rotate the inside lever or depress the push bar to open the door. Operation should be smooth, and the latch should retract. 2. Insert the key into the keyway and rotate the key and the outside lever to open the door. Operation should be smooth, and the latch should retract. Electronic test 1. Press any number key. The lock will beep. Use the default PIN (13579 and “#”) to verify access. Normal lock operation After PIN credentials have been programmed, enter a PIN to operate the lock: Press a valid PIN. The green LED will blink and access is granted. The “#” key is used as ENTER key for PINs with fewer than six digits. Default minimum digits is six (6). PIN length may be manually configured so users do not have to push the “#” key (see Change PIN length on page 7). If the PIN credential is entered incorrectly, press “ * ” to start over. 8 • Schlage • CO-100 user guide Lock status reports Follow the steps below to obtain lock status reports: LL Lock status reporting is available with firmware version 2.5.0 or higher. LL The left and right Schlage button LEDs will blink red once with each button press, followed by the status indicator as described below. Function / Report Press Press and hold Initiate report mode while pressing Indicator/Report result Wait until only the right Schlage button LED is on to indicate the lock is in report mode and awaiting an entry. If no entry is made, then timeout will occur in 20 seconds. Left LED: Solid green = excellent Blinking green = good Blinking red = low No indicator = critical battery Battery status Once a status is reported, both left and right LEDs will light green, followed by solid green on the right LED only. The right green LED indicates the lock is awaiting another entry. Obtain an additional status report as described below, or press report mode. Function / Report Firmware status Hardware status PCB serial number Press to exit Indicator/Report result Left LED blinks green for the version number Decimal point is indicated by one red blink “Zero” is indicated by two red blinks Left LED blinks green for each number Each number is separated by two red blinks Press number after two red blinks to display the next If no entry is made within 20 seconds of the solid green right LED, then timeout will occur. To exit report mode at any time, press . 9 • Schlage • CO-100 user guide Reset to factory defaults All information in the main controller in the lock will be deleted and reset to factory defaults! Main controller configurations that will reset to factory default include: programming and user codes. The door must be locked (not toggled open or in the middle of normal access) before resetting to factory defaults. Follow these steps to reset to factory defaults. 1. Remove the top inside cover. 2. Remove one battery from the battery pack to disrupt power. Wait 5 to 10 seconds for power to run out in the lock. 3. Press and hold the Schlage button while reconnecting the battery into the battery pack to resupply power. 4. Continue holding the Schlage button, and wait for two beeps to sound and two green blinks of the Schlage button. 5. Release the Schlage button. 6. Press and release the Schlage button three (3) times within 10 seconds of the beeps and blinks at step 4. One beep will sound and one red blink will occur with each press. 7. The Schlage button will light green for one second and a one-second beep will sound, indicating that the lock has been reset. LL If the Schlage button is not pressed 3 times within 10 seconds, two beeps and two red blinks indicate timeout. 8. Replace the top inside cover. To test, enter 13579 and “#”. The Schlage button will blink and the lock will unlock momentarily. Batteries To install or replace alkaline batteries LL 1. 2. 3. Changing batteries does not affect any programmed data. Remove the battery cover. Remove the battery bracket. Do not allow the battery pack to hang from the wires. Install the new batteries (install only new AA Alkaline batteries). Make sure the batteries are installed in the correct orientation. 4. Reinstall the battery pack and battery bracket. 5. Reinstall the battery cover, making sure the plug is to the right of the battery pack (CY, MS and MD locks). Be careful not to pinch the battery wires when installing the battery cover. CAUTION! Danger of explosion if batteries are incorrectly replaced! Replace only with new AA alkaline batteries. Dispose of used batteries according to the manufacturer’s instructions. This product has been evaluated for ULC-S319 compliance with AA and coin cell batteries listed below. For installations requiring ULC-S319, these battery models should be used. AA batteries: Duracell PC1500, MN1500; Energizer E91, EN91, AX91, XR91; RayoVac 815, 815-HE Coin cell batteries: Energizer CR2025, CR2032; Maxell CR2025, CR2032, Panasonic CR2025, CR2032; RayoVac KECR2025, KECR2032. 10 • Schlage • CO-100 user guide ! Plug MUST Be on Right CY, MS, & MD 993 Low battery indications Condition Indicator Batteries low After credential PIN is pressed, 9 red blinks of Schlage button, then normal indicator. Battery No LED or beeps failure Valid credentials do not grant access Solution Replace batteries immediately to avoid battery failure. Lock is intended to operate for 500 cycles in low battery condition. Replace batteries immediately. Mechanical override key must be used to unlock the lock. Battery failure mode In the event of battery failure, the lock will fail As-Is (lock remains in current state, locked or unlocked, until batteries are replaced). LED reference Schlage button Condition Access denied Valid PIN entered while lock in Freeze mode Factory default reset Low battery indicator, AA batteries Momentary unsecured access Optional Inside Push Button (IPB) Action Office Mode Press IPB to lock Press IPB to unlock 1 Lights 2 red blinks 12 red blinks indicating lockout One-second solid green with one-second beep 9 left red blinks 1 green blink, then one red blink on relock Lights 1 red blink 1 green blink 1 Unlocking the lock with the IPB will cause the lock to remain unlocked until the IPB is depressed again. 11 • Schlage • CO-100 user guide Troubleshooting Problem The lock does not function when a valid PIN credential is entered, or the lock beeper does not sound. Possible cause The beeper may be turned off. Solution Use manual programming to enable the beeper (see Disable/enable beeper on page 7). Check that the battery or wired power is The battery or wired connected correctly. power may be improperly connected. Check that batteries are inserted in the correct The batteries may be polarity. inserted with incorrect Replace batteries. polarity. Check that the optional IPB through-door ribbon The batteries may be cable is plugged in correctly (if applicable). The depleted. red wire should be on the left and not pinched in the door. If applicable, the IPB through-door ribbon Check that there are no bent pins on the optional cable may not be IPB through-door cable. properly plugged in, or Refer to the installation instructions that came may have bent pins. with the CO-100 lock, or this user guide for details on the above mentioned procedures. FCC Statements This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. Customer Service 1-877-671-7011 www.allegion.com/us © Allegion 2015 P516-270 Rev. 12/15-f
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2015:12:07 10:17:38-07:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2017:01:25 16:31:17-07:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2017:01:25 16:31:17-07:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:a7500e46-9654-4058-81ec-121807487a36 Original Document ID : xmp.did:90CB078F985ADE11B2FCC04FCB4A3E34 Document ID : xmp.id:7FE2E461069DE511B135FBC2F388C77D Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:7EE2E461069DE511B135FBC2F388C77D Derived From Document ID : xmp.did:8FF36E95D599E511AF66BF92D81433D5 Derived From Original Document ID: xmp.did:90CB078F985ADE11B2FCC04FCB4A3E34 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2015:12:07 10:17:38-07:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 12EXIF Metadata provided by EXIF.tools