Schneider Electric Altivar 58 Trx Users Manual 8806CT9901
58 TRX to the manual 21fa05ec-d5b2-495f-95be-45d154e607f1
2015-02-06
: Schneider-Electric Schneider-Electric-Altivar-58-Trx-Users-Manual-526930 schneider-electric-altivar-58-trx-users-manual-526930 schneider-electric pdf
Open the PDF directly: View PDF
Page Count: 232 [warning: Documents this large are best viewed by clicking the View PDF Link!]
- Drives Product Support and Contacts
- Product Overview
- User Interface Options and Accessories
- ATV58 TRX Type H Drive Controllers
- ATV58 TRX Type E Drive Controllers
- ATV58 TRX Type F Drive Controllers
- ATV58 TRX Type N Drive Controllers
- ATV58 Type FVC Drive Controllers
- Terminal Locations For ATV58 TRX Type H and Type FVC Drives
- Terminal Locations For ATV58 TRX Type H Drives
- Description of Power Terminals
- Conduit Connections for Type E and Type F Drive Controllers
- Description of Control Terminals
- Description of ATV58 Type FVC Control terminals
- keypad display
- PowerSuite Option
- Magelis Terminal
- Summary of User Interface Options
- I/O Extension Cards
- Communication Options
- Ventilation Kits
- Conduit Entry Kits
- Dynamic Braking Resistor Kits
- Electromagnetic Compatibility (EMC) Kits
- Internal RFI Filters
- External RFI filters
- line reactors
- Motor protecting output filters
- Macro-Configuration Programming
- Drive Controller Identification Screen: Increasing Power Rating for Variable Torque Applications
- Display Parameters
- Adjustment Parameters
- Drive and Motor configuration Parameters
- Input Frequency
- Nominal Motor Voltage
- Nominal Motor Frequency
- Nominal Motor Current
- Nominal Motor Speed (rpm)
- Motor Power Factor
- Auto Tune
- Automatic Adaptation of the Deceleration Ramp
- Alternate Ramp Switching using Frequency Threshold
- Acceleration and Deceleration Ramp Profile
- Torque Limit
- Current Limit
- Switching Frequency
- Motor Noise Reduction
- Energy Economizer
- Volts/Hertz Adjustment
- Current Limit Adaptation
- Special Motor Adaptation
- Thermal Protection of Motor
- Thermal Protection with PTC Probes
- Thermal Protection of ATV58 TRX Controller
- Drive Control Parameters
- Configurable I/O Functions
- Function Compatibility
- Assignment of Logic Inputs (LIx)
- Reverse Operation
- Alternate Ramp Switching
- Jog Speed
- + Speed
- +/– Speed
- Setpoint Memory
- Preset Speeds
- Controlled Stop Functions
- Switching Between Two Motors
- Freewheel Stop Below Selectable Frequency
- Torque Limit by Logic Input (Constant Torque Rated Products)
- Forced Local
- Fault Reset
- External Fault
- Reference Switching (Auto – Manual)
- Auto Tune
- Assignment of Analog Inputs (AIx)
- Assignment of Analog Inputs (AIx) With Analog I/O Extension Card
- Assignment of Logic Outputs (R2 or LOx)
- Assignment of Analog Outputs (AOx)
- Fault Management Parameters
- Additional Functionality Provided in the ATV58 Type FVC Drive
- ATV58 Type FVC Adjustment Parameters
- ATV58 Type FVC Analog Inputs
- ATV58 Type FVC Analog Outputs
- ATV58 Type FVC Logic Outputs
- Parameter summary
- Menu Overview
- Communication Parameters (Parameters Available Via The Communication Link)
- Power section construction Information
- Block Diagram for ATV58HU09M2 to ATV58HD12M2 (0.5 to 10 hp, 208/230 Vac) and ATV58HU18N4 to ATV58...
- Block Diagram ATV58HD16M2 to ATV58HD46M2 (15 to 40 hp/50 hp VT 208/230 Vac) and ATV58HD28N4 to AT...
- Block Diagram for ATV58HC10N4X to ATV58HC33N4X (125 to 500 hp, 400/460 Vac)
- Integration reduces the part count which allows for smaller package size while increasing the rel...
- Performance Information (Constant Torque Rated Products)
- Speed Regulation (Constant Torque Rated Products)
- Installation Recommendations
- Wiring Recommendations
- Recommendations for Wire Sizing
- Output Wiring Precautions
- Grounding
- Using a Line Contactor or an Output Contactor
- Wiring Diagrams for ATV58 TRX Type H and Type N Controllers
- Wiring Diagram for ATV58 TRX Type E Controllers (Single Phase)
- Wiring Diagram for ATV58 TRX Type E Controllers (Three Phase)
- Wiring Diagram for ATV58 TRX Type F Controllers (Single Phase)
- Wiring Diagram for ATV58 TRX Type F Controllers (Three Phase)
- Recommended Branch Circuit Protection Devices
- Fuses
- Circuit Breakers
- ATV58 TRX Type H Specifications
- ATV58 Type FVC Specifications
- Dimensions
- ATV58 TRX Type H and Type FVC Models
- ATV58 TRX Type E and Type F Models
- ATV58 TRX Type N Models
- Conduit Entry Kit (VW3A58842 to VW3A58845)
- Conduit Entry Kit (VW3A58846 and VW3A58847)
- Ventilation Fan Kits (VW3A58821 to VW3A58826)
- Single-Phase Line Reactors (VW3A58501 and VW3A58502)
- RFI Input Filters (EMC) (VW3A58401 to VW3A58407)
- Plate for EMC Mounting
- Weights
- Selection
- Suggested Specifications For ATV58 Type H Controllers
- Introduction
- Enclosure Types
- Power Circuits
- Operator Control Device Options
- Pilot Light Options
- Communication and Option Cards
- Miscellaneous Options
- Control Options
- Enclosure & miscellaneous modifications
- Power Options
- Line Reactors:
- Motor Protecting Output Filters:
- Notes:
- .Class 8839 58M Enclosed Drives 1–20 hp CT Controllers and 1–25 hp VT Controllers @ 460 V and 1–1...
- 125–500 hp VT Controllers @ 460 V
- 125–500 hp VT Controllers @ 460 V with Integrated or Barriered Bypass (Front and Side Views)
- 125–500 hp VT Controllers @ 460 V with Integrated or Barriered Bypass (Conduit Views)
- AC Drive Selection
- Ambient Temperature/Altitude
- AC Line & Motor Voltage
- Power Factor
- Harmonics
- Input Currents Ratings (with and without Line Reactor)
- Drive Isolation Transformer
- Speed Range & Regulation
- Accelerating Torque
- Dynamic Braking
- Follower Signals
- PI Regulator
- Bypass Operation
- Motor Selection
- Enclosure Types
- Relay Contact Ratings
- ENCLOSED ADJUSTABLE FREQUENCY DRIVES (1 to 500 HP)
- PART 1 GENERAL
- PART 2 PRODUCT
- 2.01 MANUFACTURERS
- 2.02 GENERAL DESCRIPTION
- 2.03 CONSTRUCTION
- 2.04 MOTOR DATA
- 2.05 APPLICATION DATA
- 2.06 ENVIRONMENTAL RATINGS
- 2.07 RATINGS
- 2.08 PROTECTION
- 2.09 ADJUSTMENTS AND CONFIGURATIONS
- 2.10 OPERATOR CONTROLS
- 2.11 AC DRIVE SEQUENCING REQUIREMENTS
- 2.12 SYSTEM CONTROL AND INTERFACE REQUIREMENTS
- 2.13 Communication and Networking Requirements
- 2.14 MESSAGE DISPLAY CENTER REQUIREMENTS
- 2.15 EMERGENCY FULL SPEED REQUIREMENTS
- 2.16 HARMONIC MITIGATION EQUIPMENT REQUIREMENTS
- 2.17 HARMONIC ANALYSIS
- PART 3 EXECUTION
- Drive Selection
- Standard Features
- Factory Modifications
- FACTORY Modifications (CONTINUED)
- FACTORY Modifications (CONTINUED)
- Component Locations
- Component LOCATIONS (Continued)
- Component LOCATIONS (CONTINUED)
- Controller Ratings
- Controller Ratings (continued)
- Input Current Ratings
- Input Current Ratings (continued)
- Technical Characteristics
- Dissipated Watts Loss
- Dimensions and Weights for Type 1 and Type 12K Enclosures
- Dimensions and weights for Type 1 and Type 12K Enclosures (continued)
- Recommended Spare Parts
- Circuit Breaker List
- Application Information
- Application Information (Continued)
- SPECIFICATIONS FOR CENTRIFUGAL PUMP AND FAN APPLICATIONS CLASS 8839 Econoflex™ AC DRIVES
- General Information
- MCC Package Features
- Factory Options
- Monitoring and Indication
- AC Drive Options
- Basic “Drive” Power Circuit
- Space Requirements
- Power Contactor Options
- Pilot Devices
- Miscellaneous Options
- Multi-drive Process Line Cabinets
- Wiring Diagrams
- EncDrives (Screen).pdf
- Drive Selection
- Standard Features
- Factory Modifications
- FACTORY Modifications (CONTINUED)
- FACTORY Modifications (CONTINUED)
- Component Locations
- Component LOCATIONS (Continued)
- Component LOCATIONS (CONTINUED)
- Controller Ratings
- Controller Ratings (continued)
- Input Current Ratings
- Input Current Ratings (continued)
- Technical Characteristics
- Dissipated Watts Loss
- Dimensions and Weights for Type 1 and Type 12K Enclosures
- Dimensions and weights for Type 1 and Type 12K Enclosures (continued)
- Recommended Spare Parts
- Circuit Breaker List
- Application Information
- Application Information (Continued)
- SPECIFICATIONS FOR CENTRIFUGAL PUMP AND FAN APPLICATIONS CLASS 8839 Econoflex™ AC DRIVES
- Sec01Page1 Screen.pdf
- Product Overview
- User Interface Options and Accessories
- ATV58 TRX Type H Drive Controllers
- ATV58 TRX Type E Drive Controllers
- ATV58 TRX Type F Drive Controllers
- ATV58 TRX Type N Drive Controllers
- ATV58 Type FVC Drive Controllers
- Terminal Locations For ATV58 TRX Type H and Type FVC Drives
- Terminal Locations For ATV58 TRX Type H Drives
- Description of Power Terminals
- Conduit Connections for Type E and Type F Drive Controllers
- Description of Control Terminals
- Description of ATV58 Type FVC Control terminals
- keypad display
- PowerSuite Option
- Magelis Terminal
- Summary of User Interface Options
- I/O Extension Cards
- Communication Options
- Ventilation Kits
- Conduit Entry Kits
- Dynamic Braking Resistor Kits
- Electromagnetic Compatibility (EMC) Kits
- Internal RFI Filters
- External RFI filters
- line reactors
- Motor protecting output filters
- Macro-Configuration Programming
- Drive Controller Identification Screen: Increasing Power Rating for Variable Torque Applications
- Display Parameters
- Adjustment Parameters
- Drive and Motor configuration Parameters
- Input Frequency
- Nominal Motor Voltage
- Nominal Motor Frequency
- Nominal Motor Current
- Nominal Motor Speed (rpm)
- Motor Power Factor
- Auto Tune
- Automatic Adaptation of the Deceleration Ramp
- Alternate Ramp Switching using Frequency Threshold
- Acceleration and Deceleration Ramp Profile
- Torque Limit
- Current Limit
- Switching Frequency
- Motor Noise Reduction
- Energy Economizer
- Volts/Hertz Adjustment
- Current Limit Adaptation
- Special Motor Adaptation
- Thermal Protection of Motor
- Thermal Protection with PTC Probes
- Thermal Protection of ATV58 TRX Controller
- Drive Control Parameters
- Configurable I/O Functions
- Function Compatibility
- Assignment of Logic Inputs (LIx)
- Reverse Operation
- Alternate Ramp Switching
- Jog Speed
- + Speed
- +/– Speed
- Setpoint Memory
- Preset Speeds
- Controlled Stop Functions
- Switching Between Two Motors
- Freewheel Stop Below Selectable Frequency
- Torque Limit by Logic Input (Constant Torque Rated Products)
- Forced Local
- Fault Reset
- External Fault
- Reference Switching (Auto – Manual)
- Auto Tune
- Assignment of Analog Inputs (AIx)
- Assignment of Analog Inputs (AIx) With Analog I/O Extension Card
- Assignment of Logic Outputs (R2 or LOx)
- Assignment of Analog Outputs (AOx)
- Fault Management Parameters
- Additional Functionality Provided in the ATV58 Type FVC Drive