Schneider Electric Connexium Ethernet Gateway Tsxetg100 Users Manual User's Guide
TSXETG100 to the manual 4dfe6a1d-2a0a-44e8-b6da-b1942a12cd73
2015-02-06
: Schneider-Electric Schneider-Electric-Connexium-Ethernet-Gateway-Tsxetg100-Users-Manual-526954 schneider-electric-connexium-ethernet-gateway-tsxetg100-users-manual-526954 schneider-electric pdf
Open the PDF directly: View PDF
.
Page Count: 19
| Download | |
| Open PDF In Browser | View PDF |
ENGLISH Instruction Bulletin ConneXium Ethernet Gateway TSXETG100 63230-319-211A1 2/2006 User’s Guide Instrucciones en Español: página 19 Instructions en Français: page 39 Anweisungen auf Deutsch: Seite 59 Retain for future use. TABLE OF CONTENTS INTRODUCTION ........................................................................................ 2 Supported Ethernet Protocols..................................................................... 2 Hardware .................................................................................................... 2 Additional Resources .................................................................................. 3 ACCESSING THE ETG OVER A NETWORK............................................ 3 Logging into the ETG .................................................................................. 3 Logging Out ................................................................................................ 3 ETG USER INTERFACE OVERVIEW........................................................ 4 SETUP ........................................................................................................ 5 Ethernet and TCP/IP Settings..................................................................... 5 Duplicate IP Address Detection............................................................. 6 Serial Port ................................................................................................... 7 Device List .................................................................................................. 8 Master Mode Device List Setup ............................................................ 8 Slave Mode Device List Setup .............................................................. 9 User Accounts........................................................................................... 10 Web Page Access..................................................................................... 11 Modbus TCP/IP Filtering........................................................................... 12 SNMP Parameters .................................................................................... 13 DIAGNOSTICS ......................................................................................... 14 Statistics.................................................................................................... 14 Interpreting Statistics........................................................................... 15 Read Device Registers ............................................................................. 17 FIRMWARE .............................................................................................. 18 Finding the Firmware Version ................................................................... 18 Getting New Firmware .............................................................................. 18 Updating the Firmware File....................................................................... 18 1 ConneXium™ Ethernet Gateway Introduction INTRODUCTION 63230-319-211A1 2/2006 ENGLISH This manual is to be used with a ConneXium™ ETG100 with firmware version 2.0 or higher. For installation information, see the installation guide. The ETG100 is a communications device that provides connectivity between Ethernet (Modbus TCP/IP) and serial line devices, allowing Modbus TCP/IP clients to access information from serial slave devices. It also allows serial master devices to access information from slave devices distributed across an Ethernet network. Supported Ethernet Protocols The ETG supports the following Ethernet protocols: • Modbus TCP/IP: Modbus TCP/IP is a combination of the Modbus protocol, which provides master-slave communication between devices, and TCP/IP, which provides communications over an Ethernet connection. Modbus TCP/IP is used to exchange data between the ETG and other compatible Modbus TCP/IP devices via TCP port 502. • Hypertext Transfer Protocol (HTTP): HTTP is a network protocol that handles the delivery of files and data on the World Wide Web. It provides web server functionality via TCP port 80. Remote configuration of the ETG and the viewing of diagnostic data is possible using a web browser. • File Transfer Protocol (FTP): FTP is a network protocol that provides the ability to transfer files over the Internet from one computer to another. FTP is used to transfer firmware updates to the ETG via TCP port 21. • Simple Network Management Protocol (SNMP): Based on MIB2 format, SNMP provides the ability to store and send identifying and diagnostic information used for network management purposes via UDP port 161 . • Address Resolution Protocol (ARP): ARP is used to convert IP addresses to Ethernet addresses. ARP requests are sent by the ETG to determine if its address is a duplicate IP address (see “Duplicate IP Address Detection” on page 6). Hardware RJ45 Ethernet port Control power LEDs for Ethernet and serial communications Power and Status LED RS485 serial port Bias, termination, and 2-wire/4-wire jumper switches Reset button RS232 serial port (RJ45 connector) 2 © 2006 Schneider Electric. All Rights Reserved. ConneXium™ Ethernet Gateway Accessing the ETG Over a Network Additional Resources Documentation and Firmware: Go to www.telemecanique.com, select Products > Products index > Systems and architectures > Connexium. ACCESSING THE ETG OVER A NETWORK After you set up the Ethernet parameters (see the installation guide), you can access the ETG over an Ethernet LAN using Internet Explorer 6.0 or higher. ENGLISH 63230-319-211A1 2/2006 Logging into the ETG Action Result 1. Launch Internet Explorer 6.0 or higher. Opens Internet Explorer. 2. In the Address text box, type the address of your ETG (169.254.0.10 is the default), then press Enter. Opens the Login dialog box. 3. Type your user name (Administrator is the default) and password (Gateway is the default) into the text boxes, then click OK. Enters the user name and password, then opens the ETG home page. 4. Click Setup to access the ETG setup page, Opens the Setup or Diagnostics pages. or click Diagnostics to access the ETG diagnostics page. Figure 1: The ETG Home Page Menu bar Logging Out We recommend logging out whenever you do not need access to the ETG. To log out of the ETG configuration session, click Log Out to end your session. © 2006 Schneider Electric. All Rights Reserved. 3 ConneXium™ Ethernet Gateway ETG User Interface OVERVIEW ENGLISH ETG USER INTERFACE OVERVIEW 63230-319-211A1 2/2006 The ETG ships with seven pre-installed web pages used for ETG setup and configuration. See Table 1 for a description of each web page. Table 1: ETG static web pages ETG Web Page Description See Page Setup Ethernet & TCP/IP Configure Ethernet and TCP/IP communication settings. 5 Serial Port Set up or change serial communication parameters. 7 Device List Identify serial devices on the daisy chain. 8 User Accounts➀ Create and edit groups and users. 10 Web Page Access➀ Select web page access rights for each user group. 11 Modbus TCP/IP Filtering➀ Set up which IP addresses can access the ETG through Modbus TCP/IP. 12 SNMP Parameters➀ Enable and configure the Simple Network Management Protocol (SNMP), which allows the ETG to identify itself to network devices requesting SNMP data. 13 Statistics Displays diagnostic data used to troubleshoot network problems. This page also contains information about your specific ETG, including the serial number, manufacturing date, and Media Access Control (MAC) address. 14 Read Device Registers Allows ETG administrators to read register data from a serial device connected to the ETG. 17 Diagnostics ➀Accessible 4 by administrator only © 2006 Schneider Electric. All Rights Reserved. 63230-319-211A1 2/2006 To access the Setup web page links, click Setup on the ETG menu bar. ENGLISH SETUP ConneXium™ Ethernet Gateway Setup Ethernet and TCP/IP Settings Action Result 1. From the Setup page, click Ethernet & TCP/IP. Opens the Ethernet & TCP/IP page. 2. Select your frame format and media type. Contact your network administrator if you do not know. Selects the frame format and media type. 3. Enter your IP address, subnet mask, and default gateway address assigned to your ETG by your network administrator. Enters the Ethernet parameters for the ETG. 4. Click Apply. Updates the ETG Ethernet and TCP/IP settings. NOTE: If you enter an IP address that is used by another device, you will be prompted to select a new IP address. See “Duplicate IP Address Detection” on page 6. * See Table 2 on page 5 for a list of options. NOTE: After making changes to the Ethernet parameters and clicking Apply, the ETG will reboot. Figure 2: Table 2: Ethernet & TCP/IP Page ETG Ethernet and TCP/IP Settings Option Description Setting Frame Format Used to select the format for data sent over Ethernet II, 802.3 SNAP an Ethernet connection. Default: Ethernet II Media Type Used to define the physical Ethernet connection or media type. IP Address Used to enter the static IP address of the ETG. 0.0.0.0 to 255.255.255.255 Subnet Mask Used to enter the Ethernet IP subnet mask address of your network. 0.0.0.0 to 255.255.255.255 Default Gateway Used to enter the gateway (router) IP 0.0.0.0 to 255.255.255.255 address used for wide area network (WAN) Default: 0.0.0.0 communications. • • • • • 10T/100Tx Auto 10BaseT-HD 10BaseT-FD 100BaseTX-HD 100BaseTX-FD Default: 10T/100Tx Auto © 2006 Schneider Electric. All Rights Reserved. Default: 169.254.0.10 Default: 255.255.0.0 5 ConneXium™ Ethernet Gateway Setup Duplicate IP Address Detection 63230-319-211A1 2/2006 ENGLISH While connected to your network, the ETG publishes its IP address. To avoid any duplicate IP address conflicts, the ETG uses the Address Resolution Protocol (ARP) to see if any other device on your network is using the same IP address. Table 3 below explains how the ETG handles a duplicate IP address when it is detected. Table 3: Duplicate IP Detection Scenarios Scenario Duplicate IP Detected Boot Process / Power Restore Reverts to the default ETG IP Four blinks, pause pattern address, subnet mask, and gateway address. ARP requests are sent every 15 seconds until the IP address is available. When the IP address becomes available, the ETG will use it. Ethernet Link Detected Power/Status LED Manual Address Change ETG keeps it’s previous IP address and displays a message indicating that the IP address is already in use by another device. Receives an ARP request Reverts to the default ETG IP address, subnet mask, and gateway address if a connected device sends four ARP requests for the ETG’s IP address. The ETG will send ARP requests every 15 seconds until the IP address is available again. When the IP address becomes available, the ETG will use it. 6 Four blinks, pause pattern © 2006 Schneider Electric. All Rights Reserved. 63230-319-211A1 2/2006 ConneXium™ Ethernet Gateway Setup Serial Port Result ENGLISH Action 1. From the Setup page, click Serial Port. Opens the Serial Port page. 2. Select your mode, physical interface, transmission mode, baud rate, parity, and response timeout (see Table 4 on page 7). Selects the serial port options. 3. If you select Slave mode, enter the IP addresses for the remotely connected devices (see Table 4 on page 7). Enters the IP addresses of the remote devices. 4. Click Apply. Updates the ETG Serial Port settings. Figure 3: Serial Port Page Table 4: Serial Port Settings Option Mode Description Used to select how the COM port on the ETG is utilized (master or slave). Setting Master, Slave Default: Master NOTE: When the Mode is changed, the ETG reboots. Physical Interface Used to select how the ETG serial port is physically wired. RS485 4-wire, RS485 2-wire, or RS232 Transmission Mode Used to select how data is transmitted over Modbus RTU, Modbus ASCII a serial connection. Default: Modbus RTU Baud Rate Used to select the data transmission speed 2400, 4800, 9600, 19200, over a serial connection. 38400, 56000*, 57600* Parity Used to select if data is checked for accuracy using a parity bit. Default: RS485 2-wire Default: 19200 Even, None Default: Even Response Timeout Used to select how long the ETG will wait 0.1 to 10 seconds to receive a response from a serial device. Default: 3 seconds Used to define a list of Modbus TCP/IP Remote Modbus addresses for the ETG to use during slave TCP/IP mode communications. Connections (Slave mode only) — * Available only if the physical interface and transmission mode is RS232/Modbus ASCII. © 2006 Schneider Electric. All Rights Reserved. 7 ConneXium™ Ethernet Gateway Setup Device List 63230-319-211A1 2/2006 Before you begin, keep in mind the following: ENGLISH For master mode usage of the COM port: • Master Mode Device List Setup Modbus devices do not have to be defined in the Device List, but it helps you manage your system. Figure 4: Master Mode Topology Ethernet Connection ETG in master mode RS485 connection Up to 128 serial slave devices using repeaters Serial Slave Devices If you selected Master mode on the Serial Port page, follow the steps below to set up the device list: Action Result 1. From the Setup page, click Device List. Opens the Device List page. 2. Select the number of viewable devices (1 to Selects the number of viewable locations that 128), then click Apply. can be used to define serial slave devices connected to the ETG. 3. In the Local ID text box, type the local ID (address) of the serial slave device. Enters the local address of the device. 4. Repeat step 3 until all of the devices are entered. Enters all of the connected devices. 5. Click Apply. Updates the Device List settings. Figure 5: 8 Device List Page in Master Mode © 2006 Schneider Electric. All Rights Reserved. 63230-319-211A1 2/2006 ConneXium™ Ethernet Gateway Setup Figure 6: Serial port slave mode allows serial Modbus master devices to access information from serial slave devices across a TCP/IP network. Figure 6 below illustrates how the devices are connected using the device list settings in Figure 7. ENGLISH Slave Mode Device List Setup Slave Mode Topology Ethernet Connection ETG in master mode ETG in master mode IP address: 169.254.0.28 IP address: 169.254.0.75 RS485 connection 2 ETG in slave mode RS232 or RS485 connection RS485 connection 5 Up to 16 remote IP connections with up to 128 serial slave devices are possible 2 3 4 5 6 7 Serial Slave Devices Serial Slave Devices If you selected Slave mode on the Serial Port page, follow the steps below to set up the device list: Action 1. From the Setup page, click Device List. Result Opens the Device List page. 2. Select the number of viewable devices (1 to Selects the number of viewable locations that 128), then click Apply. can be used to define remote Modbus TCP/IP devices. 3. In the Local ID text box, type the local ID (address) of the serial slave device. Enters the address of the device that the local Modbus master device will use to access the remote device. 4. In the Remote ID text box, type the remote Enters the serial slave address of the remotely ID (address) of the serial slave device. connected device. 5. Select the Connection. Selects the Modbus TCP/IP address to associate with the remote ID. 6. Repeat steps 3 through 5 until all of the devices are entered. Enters all of the mapping information for the ETG to communicate to the remote devices. 7. Click Apply. Updates the Device List settings. Figure 7: © 2006 Schneider Electric. All Rights Reserved. Device List Page in Slave Mode 9 ConneXium™ Ethernet Gateway Setup User Accounts 63230-319-211A1 2/2006 ENGLISH ETG users are assigned user names and passwords. Each user belongs to a group, and each group has access rights to the ETG Web pages assigned by the ETG administrator. NOTE: There are two default user accounts: Administrator (password is Gateway) and Guest (password is Guest). Action Result 1. From the Setup page, click User Accounts. Opens the User Accounts page. 2. If you want to change a group name, type a Enters a new group name. new name in one of the Groups text boxes (the Administrator group name cannot be changed). 3. In the Users section, enter a Name (1 to 24 Enters the name and password for a user. characters) and Password (0 to 12 characters) for a new user. NOTE: User names and passwords are case-sensitive and can contain only alphanumeric characters. 4. Select a group and the default language for Selects the group and language for a user. the new user. 5. Repeat steps 3 and 4 for each additional user you want to add. Continues adding users. 6. Click Apply. Saves all of the user account settings. Table 5: ETG accounts and passwords Account Gateway Guest Guest User-defined accounts (up to 11 accounts possible) No default –Password is user-defined Figure 8: 10 Default Password Administrator User Accounts Page © 2006 Schneider Electric. All Rights Reserved. 63230-319-211A1 2/2006 ConneXium™ Ethernet Gateway Setup Web Page Access Result Opens the Web Page Access page. 2. In the Ethernet & TCP/IP row, select the See Table 6 below for an explanation of access access level (None, Read-only, or Full) that levels for each group. each user group will have for the Ethernet & TCP/IP web page. Allows the default Guest group to access the 3. To allow Guest access to the web page, select Read-only under the Guest column. web page. NOTE: If the Guest group is Read-only, other groups may only be set to Read-only or Full. 4. Repeat steps 2 and 3 for the Serial Port, Device List, Statistics, and Read Device Registers rows. Selects the access level for each web page. 5. Click Apply. Saves the password settings. Table 6: Group Access Group Access Administrator Full access to all web pages NOTE: We recommend that you change the default administrator password for system security the first time you log in. Guest Read-only access to selected web pages. Three user-defined groups Choosing from the following options, the administrator assigns web page access for each group. Access levels are as follows: • • • Figure 9: © 2006 Schneider Electric. All Rights Reserved. None: a group has no access to selected web page Read-only: password grants a group read-only access to the selected web page Full: a group has the same access as the Administrator group to the selected web page Web Page Access Page 11 ENGLISH Action 1. From the Setup page, click Web Page Access. ConneXium™ Ethernet Gateway Setup Modbus TCP/IP Filtering 63230-319-211A1 2/2006 ENGLISH This function allows the administrator to specify Modbus TCP/IP client devices that have or do not have access to serial slave devices connected to the ETG. NOTE: There is an anonymous Modbus TCP/IP address (***.***.***.***) that can be set to Read-only or None. Setting it to Read-only allows any Modbus TCP/IP client not in the filtered list to access serial slave devices with read-only access. Setting it to None blocks all Modbus TCP/IP clients not in the filtered list. Action Result 1. From the Setup page, click Modbus TCP/IP Filtering. Opens the Modbus TCP/IP Filtering page. 2. Check Enable Filtering. Activates filtering. 3. In the IP address column, enter the Modbus TCP/IP client address Enters an IP address for a Modbus TCP/IP client that will have access to the serial devices connected to the ETG. 4. In the Access Level column, select Readonly or Full. Selects the access level for the corresponding IP address. When set to Read-only, only the following Modbus TCP/IP function codes are allowed: Decimal: 1, 2, 3, 4, 7, 8, 11, 12, 17, 20, 24, 43, 100 Hexadecimal: 01, 02, 03, 04, 07, 08, 0B, 0C, 11, 14, 18, 2B, 64 5. Repeat steps 3 and 4 to add more IP addresses. Continues adding IP addresses for filtering. 6. Click Apply. Saves the Modbus TCP/IP address filtering list. Figure 10: 12 Modbus TCP/IP Filtering Page © 2006 Schneider Electric. All Rights Reserved. SNMP Parameters ConneXium™ Ethernet Gateway Setup The ETG supports SNMP, allowing a network administrator to remotely access an ETG with an SNMP manager and view the networking status and diagnostics in the MIB2 format. Action 1. From the Setup page, click SNMP Parameters. Result Opens the SNMP Parameters page. 2. Check Enable SNMP to turn ON the simple Activates SNMP. network management protocol. NOTE: If you uncheck Enable SNMP and click Apply, the ETG will reboot and SNMP functionality will be turned OFF. 3. Enter the system contact, system name, Enters the SNMP system information and system location, read-only community community access names. name, and the read-write community name. 4. Click Apply. Figure 11: © 2006 Schneider Electric. All Rights Reserved. Saves the SNMP settings. SNMP Parameters Page 13 ENGLISH 63230-319-211A1 2/2006 ConneXium™ Ethernet Gateway Diagnostics DIAGNOSTICS 63230-319-211A1 2/2006 ENGLISH To access the Diagnostics web page links, click Diagnostics on the ETG menu bar. Statistics Action Result 1. From the Diagnostics page, click Statistics. Opens the Statistics page (see Figure 12). 2. View the data. See “Interpreting Statistics”below. 3. Click Reset. Resets the ETG cumulative diagnostic data to 0. NOTE: The Statistics page displays data based on the mode selected in “Serial Port” on page 7. NOTE: This page will show accumulated readings since the ETG was last activated. If power to the ETG is lost, all cumulative values reset to zero. Figure 12: Statistics Page Reading with Serial Port in MASTER MODE 14 Reading with Serial Port in SLAVE MODE © 2006 Schneider Electric. All Rights Reserved. 63230-319-211A1 2/2006 ConneXium™ Ethernet Gateway Diagnostics Interpreting Statistics Description Ethernet Link Status A status string that represents the speed and duplex setting being used to communicate with the linking partner. Frames Transmitted OK A counter that increments each time a frame is successfully transmitted. Collisions A counter that increments each time a frame is retransmitted due to collision detection. Excessive Collisions A counter that increments each time a frame is not able to be sent due to reaching the maximum collision status based on the Truncated Binary Exponential Backoff algorithm. Frames Received OK A counter that increments each time a frame is successfully received. CRC Errors A counter that increments each time a frame is received that has a checksum/CRC that does not match what is calculated. Alignment Errors A counter that increments each time a frame is received that has a checksum/CRC error and does not end on an 8-bit frame boundary. Frames Too Long A counter that increments each time a frame is received that is larger than the allowed maximum size defined in the standards (frames larger than 1518 bytes). Frames Too Short A counter that increments each time a frame is received that is smaller than the allowed minimum size defined in the standards (frames smaller than 64 bytes). Modbus TCP/IP Frames Sent A counter that increments each time a frame is sent. Frames Received A counter that increments each time a frame is received. Protocol Errors A counter that increments each time an ill-formed message is received. Active Connectionsc A status value that represents the number of connections that are active at the moment the diagnostics page is refreshed. A maximum of 32 connections are supported. Clicking Active Connections opens a new window with a list of all of the active client connections. Accumulative Connectionsc A counter that increments each time a connection is made to the ETG. Maximum Connectionsc A status value that represents the maximum number of connections that were active at any given moment. Inbound Read Messagesc A counter that increments each time a read request message is received. Outbound Read Messagesd A counter that increments each time a read request message is sent. Inbound Write Messagesc A counter that increments each time a write request message is received. Outbound Write Messagesd A counter that increments each time a write request message is sent. Inbound Reply Messagesd A counter that increments each time a reply message is received. Outbound Reply Messagesc A counter that increments each time a reply message is sent. c d © 2006 Schneider Electric. All Rights Reserved. Available when the serial port is in Master mode. Available when the serial port is in Slave mode 15 ENGLISH Statistic ConneXium™ Ethernet Gateway Diagnostics 63230-319-211A1 2/2006 Statistic Description ENGLISH Serial Port Frames Sent A counter that increments each time a frame is sent. Frames Received A counter that increments each time a frame is received. CRC Errors A counter that increments each time a message is received that has a CRC that does not match what is calculated. Typically the result of wiring issues. Protocol Errors A counter that increments each time an illformed message is received. Timeouts A counter that increments each time a request message is sent without receiving a corresponding response message within the allowed time. Timeouts are typically the result of configuration errors or a non-responsive device. Inbound Read Messagesd A counter that increments each time a read request message is received. Outbound Read Messagesc A counter that increments each time a read request message is sent. Inbound Write Messagesd A counter that increments each time a write request message is received. Outbound Write Messagesc A counter that increments each time a write request message is sent. Gateway Information Firmware Version The firmware version that is installed on the ETG. System Idle Time A percentage from 0% to 100% indicating the average processor time that is not being used. MAC Address The unique Ethernet hardware address of an ETG. Serial Number The serial number of the ETG. Model Number The ETG model number (100). Hardware Version ETG hardware version. Manufacture Date Date the ETG was manufactured. c d 16 Available when the serial port is in Master mode. Available when the serial port is in Slave mode © 2006 Schneider Electric. All Rights Reserved. 63230-319-211A1 2/2006 ConneXium™ Ethernet Gateway Diagnostics Read Device Registers Result Opens the Read Device Registers page. 2. Enter the device ID, starting register number, and the number of registers to read. Enters the values to begin reading registers for the specified device. 3. Click Read Holding Registers or Read Input Registers. Displays the values for the listed registers. 4. To change how the data is displayed in the Selects how the data values are displayed. Value column, select Decimal, Hexadecimal, Binary, or ASCII. Table 7: ETG Read Device Register Settings Option Description Device ID The address of the device that registers are read. Starting Register The first register to read. 1 1000 Number of Registers The number of registers to read (1 to 10). 10 Register column Lists the register numbers — Value column Lists the data stored in a register. Decimal, Hexadecimal, Select an option to specify how the Value column Binary, or ASCII options data is displayed. Figure 13: © 2006 Schneider Electric. All Rights Reserved. Default — Decimal Read Device Registers Page 17 ENGLISH Action 1. From the Diagnostics page, click Read Device Registers. ConneXium™ Ethernet Gateway Instruction Bulletin FIRMWARE 63230-319-211A1 2/2006 ENGLISH Firmware on the ETG can be updated using File Transfer Protocol (FTP). Check www.telemecanique.com or with your local sales representative for the latest firmware update. Finding the Firmware Version Action Result 1. Log into the ETG. Opens the ETG home page. 2. Locate the firmware version on the bottom-left corner of the page. Determines the firmware version of the ETG. NOTE: If you recently updated your firmware, press F5 to refresh the web page and update the displayed firmware number. 3. Alternatively, you can select Diagnostics > Also determines the firmware version of the Statistics to find the firmware version in the ETG. Gateway Information section. Getting New Firmware Action Result 1. Launch Internet Explorer, type www.telemecanique.com in the Address text box, then press Enter. Opens the Telemecanique web site. 2. Select Products, then click Product Index. Opens the Products page. 3. Select Systems and architectures. Displays the Systems and architectures card. 4. Click ConneXium. Opens the ConneXium systems and architectures page. 5. Click Software/firm. Opens the software/firmware page. 6. Click the firmware file link (eg#####.bin, Opens the File Download dialog box, then where ##### is the firmware number), then saves the firmware file. click Save. Updating the Firmware File Action Result 1. Launch Internet Explorer, type ftp:// and the Opens the Log On As dialog box. IP address of the ETG in the Address text box (for example, ftp://169.254.0.10), then press Enter. 2. Type the user name Administrator and the administrator password in the text boxes, then click Log On. Opens an FTP session with the ETG. 3. Locate the saved firmware file on your computer, select it, then press CTRL+C. Copies the firmware file to the clipboard. 4. Right-click in the Internet Explorer window, Copies the firmware to the ETG, and the ETG then click Paste. reboots. NOTE: Instead of copying and pasting the firmware file, you can drag-and-drop the firmware file into Internet Explorer. 5. Click the Close button on the Internet Explorer window. Closes Internet Explorer and ends the FTP connection to the ETG. 6. To verify that the firmware version was Verifies the updated firmware version. updated successfully, follow the steps in “Finding the Firmware Version” on page 18. www.schneider-electric.com www.telemecanique.com Electrical equipment should be installed, operated, serviced, and maintained only by qualified electrical personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. © 2006 Schneider Electric. All Rights Reserved. ConneXium™ Ethernet Gateway Handbuch 63230-319-211A1 2/2006 Maßnahme Ergebnis 5. Schließen Sie das Internet ExplorerFenster. Schließen von Internet Explorer und Beenden der FTP-Verbindung zum ETG 6. Um zu kontrollieren, ob die FirmwareVersion erfolgreich aktualisiert wurde, befolgen Sie die Schritte unter „FirmwareVersion feststellen“ auf Seite 77. Überprüfung der aktualisierten Firmwareversion DEUTSCH www.schneider-electric.com www.telemecanique.com eine Marke von Elektrisches Gerät sollte stets von qualifizierten Elektrikern installiert, betrieben und gewartet werden. Schneider Electric übernimmt keine Verantwortung für jegliche Konsequenzen, die sich aus der Verwendung dieses Gerãts ergeben könnten. © 2006 Schneider Electric. Alle Rechte vorbehalten.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2006:02:09 16:54:11Z Modify Date : 2006:04:18 08:33:57-05:00 Page Mode : UseOutlines Producer : Acrobat Distiller 7.0.5 (Windows) Mod Date : 2006:04:18 08:33:57-05:00 Creation Date : 2006:02:09 16:54:11Z Author : Brian Wilkins Creator Tool : FrameMaker 7.1 Metadata Date : 2006:04:18 08:33:57-05:00 Document ID : uuid:d6d4114d-a46e-4d29-8be1-a0e55cacfc69 Instance ID : uuid:8d7f04c0-bb0a-4e98-a069-a2e232ebc144 Format : application/pdf Title : Ethernet Gateway TSXETG100 User's Guide Creator : Brian Wilkins Page Count : 19 Has XFA : NoEXIF Metadata provided by EXIF.tools