Scientech Electronics GA2N Gas Leakage Detector User Manual

Scientech Electronics Co., Ltd. Gas Leakage Detector

User Manual

Download: Scientech Electronics GA2N Gas Leakage Detector User Manual
Mirror Download [FCC.gov]Scientech Electronics GA2N Gas Leakage Detector User Manual
Document ID1939229
Application IDwt6TqpINf6rX2Bu1AbVNJA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize92.69kB (1158617 bits)
Date Submitted2013-04-15 00:00:00
Date Available2013-04-15 00:00:00
Creation Date2012-11-28 09:49:54
Document Lastmod2013-02-19 11:30:25
Document TitleUser Manual

‘ GAS’L’EAKAGEaDETECTORiGA-ZS' "
INTRODUCTION
The GA-ZS is a gas detector, It uses electrochemical sensor to detect LNG(Liquefled
natural gas) and LPG (Liquefied petroleum gas).
The GA-ZS is built in a radio transmitter, it sends check-in signal to LS-30 base unit
regularly, and sends alarm signal when it‘s trlggered by LNG or LPG.
INSTALLATION “M
L Put the GA-ZS close to LS-30 Base LED
Unit, and plug in the power cord (Red)
of the GA-ZSl rowm _
2, Select “Installer Mode" on the motnaron
LS-30 Base Unit, and enter (Green)
Installer Password to gain access
authority. Then select \Set
Device\Enroll Devlce\l-‘ire
Sensor\Enter Zone No. to enroll
the ID of GA-ZS by presslng its TEST button. You may change its various
attributes under \Set Device\Change Device Settlng\Fire Sensor Change, to fulfill
different requirements. For lnltial installalion, thls can be done through computer
with supplied sofiware too, it‘s easier.
3‘ To detect leakage of natural gas, the detector should he placed at a higher position
near the ceiling, because Natural Gas is lighter than alri For LPG, a proper
location for detection is about 300m above the floor, since LPG is heavier than
air. Refer to the figure below.
For LNG
{H rayon,
eman- or
£004 Alcohol)
For LPG
(Isa butane)
it
4‘ After the power ofthe GA-ZS is plugged In, the red LED lights up for l minute or
so, and then the green LED llghts up while the red LED extinguishes. To test the
GA—ZS, you can put a gas lighter closely to the bottom of the detector, and then
leak its gas for about 3 seconds. The GA-ZS would beep with the red LED light
up. It would trigger “FIRE" alum of the LS-30 system at the some time
Important notice: The GA-ZS uses an electrochemical sensor wlwse life is
ubnui 5 years, the user slum/1! replace a new (FA—ZS before its life time
expires.
SPECIFICATIONS:
Detection: LNG (Liquefied Natural Bus) and LPG (quuefied Petroleum Gas)
Alarm Sensitivlty: 8,000ppm for LNG, 3.300ppm for LPG
Power: 120V or 230V AC as requested.
Power Consumption: maxi 2W
Buzzer: built in
Slze: 88 x45 x 123.5 mm
Weight: about 309g
(6
Manual-Eackcoveupg (2544xasesx16M peg)
WARRANTY
The Manufacturer warrants its products (hereinafter referred to as the Product) to
be in conformance with its own plans and specifications and to be free of defects
in materials and workmanship under normal use and service for a period of twelve
months from the date of shipment by the Manufacturer. The Manufacturer’s
obligations shall be limited within the warranty period. At its option, to repair or
replace the Product or and part thereof. To exercise the warranty the Product must
be returned to the Manufacturer freight prepaid and insured.
This warranty does not apply in the following cases: improper installation, misuse,
failure to follow installation and operating instructions, alteration, abuse, accident
or tampering, and repair by anyone other than the manufacturer.
This warranty is exclusive and expressly in lieu of all other warranties, obligations
or liabilities, whether written, oral, express or implied, including any warranty of
merchantability or fitness for a particular purpose, or otherwise. In no case shall
the Manufacturer be liable to anyone for any consequential of incidental damages
for breach of this warranty or any other warranties whatsoever, as aforesaid.
This warranty shall apply to the Product only. All Products, accessories or
attachments of others used in conjunction with the Products, including batteries,
shall be covered solely by their own warranty, if any. The Manufacturer shall not
be liable for any damage or loss whatsoever, whether directly, indirectly,
incidentally, consequentially or otherwise, caused by the malfunction of the
Product due to Products, accessories, or attachments of others, including batteries,
used in conjunction with the Products.
The Manufacturer shall have no liability for any death, personal and/or bodily
injury and/or damage to property or other loss whether direct, indirect, incidental,
consequential or otherwise, based on a claim that the Product failed to function.
NOTE: The changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
To comply with the FCC RF exposure compliance requirements, this device and
its antenna must not be co-located or operating to conjunction with any other
antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause hannful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation,
CE

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2013:02:19 11:30:25+08:00
Create Date                     : 2012:11:28 09:49:54+08:00
Page Count                      : 3
Mod Date                        : 2013:02:19 11:30:25+08:00
Creation Date                   : 2012:11:28 09:49:54+08:00
Metadata Date                   : 2013:02:19 11:30:25+08:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TYLGA2N

Navigation menu