Introduction
The RP-ZS repeater is a device built in transceiver, and it is used to ‘
expand the coverage of radio signals. To avoid useless ‘— (Egg?‘;‘,§:\,,§’,le§‘,‘§,’,§0
retransmission and to minimize the possibility of interference, ‘ '
RP-ZS only relays the specific sensors/transmitters' signal, which ,
have been enrolled during installation. Max. 10 sensors/transmitters EB‘;‘J$§’[LHE,”\‘C
can be enrolled in a RP-ZS. r;
<— BATTERY
When the RP-ZS is used, the proper location is somewhere between 0‘ WWW
the base unit and sensors. Please refer to the diagram as below, #\ LED
<—‘ l I'VDL
it lPLIT
S7 Sl
V 1 <— Exl {MAL Al\lTEl\ll\ll\
,, (Ft: LtEtvtnc)
tcnn't tench Base Umll
runs '0 LS-30 ‘ 82 i
> Base Unit
tcan'l reach Base Unit) A
S3
Fig. 1
Code enrolling and Installation
I. Stick the supplied antenna into the hole on the left top of the RP-ZS carefully.
2. Plug the power adapter of RP-ZS, and turn on the battery switch. You will hear a beep, then the
red LED starts flashing once every 5 seconds.
Note: In case the sensors have been mounted already, for the sake of convenience, you may
merely turn on its battery switch (without connecting (I power adapter, only if the internal
battery can supply power for operation), and then bring the kP—ZS close to tlte sensors to
enroll the codes.
3. when the first time you press the Enrolling Button of RP-ZS (with the tip ofa paper clip or a ball
pen) for 1 second. you will hear one beep, and the red LED keeps lighting up. Then you press the
TEST button on the sensor. or activate Disarm function on wireless keypad which needs to be
relayed, for 2 seconds then release. If RP«ZS reads a valid RF signal within 25 seconds, you will
hear two beeps, and the code enrolling terminates. Otherwise. you hear one beep when 25
seconds expire.
Note:- Please keep the enrolling process as short as possible to prevent RP-ZS from enrolling arty
nltwanterl sensor signal in the air.
- Remote C ontroller can ’I be relayed by the repeater:
4. To make sure the correct code has been enrolled, press the test button on the sensor again, the
LED on RP-2S should turn into green and flash.
5. You may repeat step} to enroll more sensor/transntittet"s code (up to l0). Each time a successful
code enrolling increases one beep to prompt next code enrolling. For instance, if 3
sensors/transit]itters have been enrolled in a RP—ZS successfully, then when you press the
Enrolling Button for the next enrolling, it will generate 4 beeps to indicate this
sensor/transmitter will be saved in the 4‘" memory ofthe RP-2S.
Remarks:
1) To optimize the system's performance, the sensor's signal which can reach the base unit
directly (ex. SI, 82, $3 in Fig. l) is no need to be enrolled into the RP-ZS. For all
sensors/transntitters needing to be relayed through the RP-ZS (ex. 58, S9 in Fig. 1), you
also have to enroll them into the base unit.
2) During the process of code enrolling. if you hear 5 beeps with the red LED flashing afler
pressing the sensor/transmitter's button, it means this sensor/transmitter has been enrolled
previously; the second code enrolling is ignored.
3) Afier 10 sensors/transmitters have been saved, the RP-ZS will generate 5 beeps with the red
LED flashing, if you press the Enrolling Button for enrolling next one. Under this condition, v
the RP-ZS will not save sensor/transmitter any more.
Erase enrolled codes
Turn off the power of the RP»ZS first (both power adapter and battery switch), press the Erolling
Bunou first then turn on the power. You will hear 3 beeps, which indicates all the previous settings
in the memory have been erased.
Installation Locations
Fig. I explains how to place the RP-ZS in a proper location. Assume all sensors' radio signals can
reach the base unit, except S7 and SE. First, you have to enroll the codes of S7 and 38 into RP-2S
and Base Unit then put the RP-ZS at somewhere between S7 & S8 and the base unit, usually closer
to S7 & 88 side. A proper location must meet two conditions, the place where A). The RP-ZS can
receive the radio signals from 878188 (you can check this by observing the LED status on the
RP—ZS) , B). The re-tralISI ion signal from the RP-ZS can reach the base unit, it's
recommended that you may do site test at several different locations before fixing the RP—ZS. For
the sake of convenience, you can turn on the battery switch of RP-ZS. without connecting a power
adapter during the test.
Remarks:
1. When the RP-ZS receives the signal from a enrolled sensor, it will re
Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2013:02:20 11:30:38+08:00
Create Date                     : 2012:11:28 10:06:13+08:00
Page Count                      : 3
Mod Date                        : 2013:02:20 11:30:38+08:00
Creation Date                   : 2012:11:28 10:06:13+08:00
Metadata Date                   : 2013:02:20 11:30:38+08:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TYLRP2N

Navigation menu