2

1

To avoid streaks or misses, slightly overlap each
strip over the edge of the previous strip. Line
up the arrow on the hopper with the wheel
track from the previous row.
Do not use wheel for alignment.

For irregular-shaped lawns, apply one header
strip around the entire lawn, and then go back
and forth.

For rectangular lawns, apply two header
strips at each end of the lawn and then go back
and forth.

Application Tips

Arrow
Wheel tracks from
previous row

Start walking, then squeeze and hold trigger to release product.

Apply

DO NOT fill spreader on the lawn. Sweep up any spilled product.

With the spreader hopper closed (trigger control away from handle), fill
the spreader over a patch of bare ground or driveway/sidewalk.

Fill Hopper

Turn the micrometer until that number appears in the micrometer window.

Find the rate setting for "Scotts Drop Spreader" found on the back of the
Scotts product package.

Set Rate

Never leave product in spreader. Pour leftover
material back into the package and seal package tightly.

For best results, follow the Scotts® Annual Lawn Care Program™, and for
seeding projects use Scotts® Pure Premium® Grass Seed.

03-AG1000 Printed in USA
P/N: 735307-001

© 2003, Licensed by The Scotts Company. World rights reserved.

®

Trusted by generations of homeowners, Scotts is
dedicated to helping you enhance and protect the
natural beauty of your home environment.

Dedicated To A Beautiful World™

The Scotts Company
14111 Scottslawn Rd.
Marysville, Ohio 43041

Scotts No-Quibble Guarantee®
If for any reason you, the consumer, are not
satisfied after using this product, you are
entitled to get your money back. Simply send
us proof of purchase and we will mail you a
refund check promptly.

Questions, Comments, Information
Call the toll-free Scotts Consumer Helpline: 1.800.543.TURF
or visit www.scotts.com

Store in a dry place.

Lubricate axle bearings with light oil.

0 32247 73445 5

Wash spreader after each use.

Spreader Maintenance

How to Apply Product

73445
ACCUGREEN 1000

125030423
PROOF OF PURCHASE

AccuGreen® 1000™

Made in the U.S.A.

Backed by Scotts No-Quibble Guarantee®

Folds for easy storage

12-inch (30cm) wheels provide stability and maneuverability

Durable, rustproof plastic parts

Holds 5,000 sq. ft. (470 sq. meters) of Scotts fertilizer

18-inch (46cm) spread width, for fast, easy coverage

U-shaped handle with handle mounted on/off control

The Scotts Difference®

accurate, easy to use, more durable and longer lasting.

to improve its entire line of spreaders, to make them more

spreader for home lawns, back in 1946. Today, Scotts continues

Drop Spreader! The Scotts Company was first to market a

®

Thank you for purchasing a Scotts

Instructions for Assembly and Use

1

11. Hubcap, 2 ea.

11

10

9

8

7

6

5

4

3

4

Micrometer
Window

3

If the bar is below the line, turn the
adjustment screw clockwise.

Tighten handle assembly and all other nuts.

Adjust Calibration Screw
If the shutoff bar covers the calibration line,
turn the adjustment screw counter-clockwise.

4

You may need to pull the shutoff bar
towards you to see the calibration line.

With your foot on the control lever, the front
edge of the shutoff bar at bottom of hopper
should line up with the calibration line
engraved into the bottom of the hopper.

Check Shutoff Bar

Screw micrometer barrel (3) into the
micrometer housing (2).

Micrometer Wire

Attach handle assembly (1) using bolts and
thumbnuts. Micrometer window must face the
front of the spreader, thumbnuts face inside.

Handle

Align hubcaps (11) and snap into place.

Slip cotter pins (10) through axle holes and
bend the ends around the axle.

10. Cotter Pin, 2 ea.*

2

Press gently with your foot on the control
lever and observe the position of the
shutoff bar.

8. Wheel, 2 ea.

7. Hopper Assembly

Slide axle washers (9) onto axle.

Position Spreader

9. Axle Washer, 2 ea.*

3

2

Shutoff bar

Calibration line

6

Calibration screw

6 centered in window

Turn micrometer until 6 is centered in window.

Set Micrometer

Stand the spreader on its handle with the
Scotts logo facing away from you.

Wheels

Hopper Slot

1

OF PRODUCT.

ASSEMBLING IT OR IT MAY SPREAD THE INCORRECT AMOUNT

IT IS NECESSARY TO CALIBRATE YOUR SPREADER AFTER

How to Calibrate
the Spreader

Slide wheels (8) onto axle with the hub
facing out.

6. Thumbnut, 4 ea.*

5. Frame Leg, 2 ea.

4. Bolt, 4 ea.*

3. Micrometer Barrel

2. Micrometer Housing

2

Parts List *Furnished in Hardware Kit

1. Handle Assembly

Attach legs to hopper, inserting bolts (4)
through hopper then leg. Fasten legs in place
with thumbnuts (6) on outside of hopper.

Frame Legs
Insert frame legs (5) into the hopper
assembly (7) slots.

1

Do not completely tighten nuts until the spreader assembly is complete.

Check to see if you have all parts shown below.

®

How to Assemble Your
AccuGreen 1000™



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2003:12:12 14:52:29Z
Modify Date                     : 2004:11:10 13:26:59-05:00
Page Count                      : 2
Creation Date                   : 2003:12:12 14:52:29Z
Mod Date                        : 2004:11:10 13:26:59-05:00
Producer                        : Acrobat Distiller 5.0.5 for Macintosh
Author                          : Adam's Computer
Metadata Date                   : 2004:11:10 13:26:59-05:00
Creator                         : Adam's Computer
Title                           : ag1000_73445-2_10-03.ai
EXIF Metadata provided by EXIF.tools

Navigation menu