LEVEL

MONITOR

SYSTEM

The TankWatch Level Monitor System is
designed to operate on 12 VDC in a sewage
holding tank, and to signal a nearly full tank
condition. This instrument will give years of
reliable service if installed properly.

DO-IT-YOURSELF
INSTALLATION INSTRUCTIONS
Your TankWatch Level Monitor System contains these items:

HOW IT WORKS...
SWITCH ASSEMBLY
INDICATOR
ASSEMBLY
Plenty of capacity...
all is well.

Red light glows...
nearly full.

2-No. 4x1/2”
MOUNTING SCREWS

GASKET

4-No. 8x3/4”
MOUNTING SCREWS

CAUTION! DO NOT USE IN FUEL TANK!

1

Select a location as far as possible away from other
tank fittings. Drill 1 1/4-in. (32mm) dia. hole (hole
saw is best) in tank TOP.
NOTE FOR SAILBOATS: Locate switch on
athwartships centerline of tank to assure accuracy
when heeled.

3

Drill mounting holes using 1/8-in.
(3mm) dia. drill bit. DO NOT mount
Switch Assembly at this time.

4

2

Locate Switch Assembly into the 1 1/4-in. hole
using care to stay on center. Mark four mounting
holes. Remove Switch Assembly.

Select a location for your Indicator Assembly. Drill
a 1-in. (25mm) dia. hole to accommodate the LED
wires.
MOUNTING TEMPLATE FOR
TANKWATCH PANEL

Drill 1-in.
(25mm) hole

5

Following the wiring diagram, route wires on a
12VDC circuit using good electrical practice.

A. Connect the red wire
through a 1/2-amp fuse
(not supplied), to the
positive DC source.
B. Connect the white wire
from the red LED to one
of the white wires on the
Float Switch Assembly.
C. Connect the remaining
white wire from the Float
Switch Assembly to the
negative DC source.

6

Place the Switch Assembly into the tank with the
gasket in place. Drive four No. 8 x 3/4” mounting
screws using care to tighten evenly. DO NOT
OVER-TIGHTEN.

MODEL INFORMATION
Part Number
313000312

Description
TankWatch 1 Panel, Float Assembly

7

Mount the Indicator Assembly. Fasten with the two
No.4 x 1/2” screws provided.

SPECIFICATIONS

Average Current Consumption:

0.016 amps

Dometic Corporation • Sanitation Systems
13128 State Rt. 226, P.O. Box 38
Big Prairie, OH 44611-0038 USA
330-496-3211
1-800-321-9886 • Fax: 330-496-3097
® Registered; ™ Trademark of Dometic Corporation
© Dometic Corporation
600340507 4/03



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2004:02:12 15:17:37Z
Modify Date                     : 2004:02:12 10:19:57-05:00
Subject                         : TankWatch 1 Holding Tank Alert System
Keywords                        : TankWatch, marine, holding, tank, alert, system
Page Count                      : 2
Creation Date                   : 2004:02:12 15:17:37Z
Mod Date                        : 2004:02:12 10:19:57-05:00
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : Technical Publications
Metadata Date                   : 2004:02:12 10:19:57-05:00
Creator                         : Technical Publications
Title                           : TankWatch 1 installation instructions
Description                     : TankWatch 1 Holding Tank Alert System
Page Mode                       : UseThumbs
EXIF Metadata provided by EXIF.tools

Navigation menu