SEARS
OWNER'S
MANUAL
Model No.
47003
CAUTION:
ReadandFollowAll Safety
',:','B_fore Every'Use"of ibis Product.
10/2/50 AMP
MANUAL
BATTERY CHARGER
ENGINE STARTER
Sears Canada, Inc., 222 Jarvis St., Toronto, Ontario, Canada M5B 2B8
Table Of Contents
Warranty .................................................................. 1
Important Safety Instructions .................................. 2
Parts ......................................................................... 3
Before Using Your Battery Charger ........................ 4
Plugging it in .......................................................... 4
Using an extension cord ........................................ 4
Preparing your battery to be charged .................... 5
Using Your Battery Charger .................................... 6
Setting the controls ................................................ 6
Charging your battery ............................................ 6
Calculating charge time ......................................... 8
Using the engine start feature ............................... 9
Maintenance and care ........................................... 9
Troubleshooting ..................................................... 10
Please read this Owner's Manual before using your Battery Charger
The Sears model 47003, Manual Battery Charger/Engine Starter, offers a wide range of features to
accommodate the needs for home or light commercial use. This manual will show you how to use your
charger safely and effectively. Please read and follow these instructions and precautions carefully.
Warranty
FULL TWO-YEAR WARRANTY
If, within two years from the date of purchase this battery charger fails due to a defect in materials or work-
manship, simply RETURN IT TO THE NEAREST SEARS STORE IN CANADA, and Sears will replace it, free
of charge.
This warranty gives you specific legal rights, and you may also have other rights which vary from province to
province.
Seam, Canada, Inc.
Toronto, Ontario, M5B 2B8
Important Safety Instructions
- SAVE THESE INSTRUCTIONS -
• Read all instructions and cautions printed on the
battery charger, battery, and vehicle or equipment
using battery.
•Use charger only on lead-acid type rechargeable
batteries, such as those used in cars, trucks, trac-
tors, airplanes, vans, RV's, trolling motors, etc.
This charger is not intended to supply power to
alow voltage electrical system other than in an
automotive application.
•Use only attachments recommended or sold by
manufacturer. The use of attachments not recom-
mended by the manufacturer may result in fire,
electric shock, or injury.
•Do not disassemble charger. Take it to a qualified
service professional if service or repair is required.
Incorrect assembly may result in fire or electrical
shock.
• To reduce risk of electrical shock, unplug the
charger from the outlet before attempting any
maintenance or cleaning.
• Always charge battery in a well ventilated area.
Help us help you
Remember:
•Place charger as far away from battery being
charged as the charger cables will permit.
•Do not expose charger to rain or snow.
•Never charge a frozen battery. If battery fluid (electro-
lyre) becomes froze n, bring battery into a warm area
to thaw before you begin charging.
• Never allow battery acid to drip on charger when
reading specific gravity or filling battery.
• Never set a battery on top of the charger.
• Never place charger directly above battery being
charged. The gases from the battery will corrode
and damage the charger.
• Never use charger for charging dry-cell batteries that
are commonly used with home appliances. These
batteries may burst and cause personal injury.
•Never touch the battery clamps together when the
charger is energized.
•Never operate charger if it has received a hard blow,
been dropped, or otherwise damaged. Take it to a
qualified professional for inspection and repair.
•Be sure to position the charger power cord to
prevent it from being stepped on, tripped over, or
damaged.
•Never pull out the plug by the cord when unplug-
ging the charger. Pulling on the cord may cause
damage to the cord or the plug.
•Do not operate the charger if it has a damaged
power cord or plug. Have the cord replaced.
Personal Safety Precautions
For your own personal safety, please follow the follow-
ing precautions:
•Wear complete eye and clothing protection when
working with lead-acid batteries.
•Be sure that someone is within range of your voice
to come to your aid if needed while you work with or
are near alead-acid battery.
•Have plenty of fresh water and soap nearby for use
in case battery acid contacts your eyes, skin, or cloth-
ing. If this happens, wash immediately with soap and
water. Then get medical attention.
oAvoid touching your eyes while working with a
battery. Acid particles (corrosion) may get into your
eyes. If this occurs, flush eyes immediately with
running cold water for at least 10 minutes. Then
immediately get medical attention.
•Remove all personal metal Items from your body,
such as rings, bracelets, necklaces, and watches
while working with a leed-acid battery. A battery can
produce a short circuit current high enough to weld
a ring (or the like) to metal, causing a severe burn.
•Take care not to drop any metal tool or metal object
onto the battery. This may spark or short circuit the
battery or another electrical device that may cause
an explosion.
•Always operate your battery charger in an open, well
ventilated area.
•Never smoke or allow aspark or flame in the vicinity
of the battery or engine. Batteries generate explosive
gases.
• Neutralize any acid spills thoroughly with baking
soda before attempting to clean up.
2
Parts
This section shows an illustration of your battery charger. Use it to become familiar with where all the parts are
located, and what they look like,
Item Description Pert Number
1Cover 3799001402
2 Heatsink/DiodeAssembly 2299000846
3 Base 3799001382
4 ACPowerCord 90026055
5 Transformer 93026312
6 OutputCable 3899000515
7 CircuitBreaker(2OA) 399900_72
8 50AClamp(1) 2299000248
SleevingRed(2)required 0399000007
SleevingBlack(2)required 039900DO08
9Meter ,539910D092
10 SwitchSPDT 0499_0031
11 Fmn_Panel 3799001392
12 Decal 0899000532
13 Handle 3599000240
14 Screw8-18x 3/8"(4) 5181806256
15 OwnersManualandPar_List(NotStrewn)000(_00549
Wiring diagram
SII3E VIEW OF SWITCH
XFORMER
BLACK
i
RI_ LEAD
=
LOCATE LUG BETWEEN
RIVET HEAD aBASE.
BLACK--
13
Before Using Your Battery Charger
It is important to understand your charger's requirements. This section will tell you about your charger's electrical
requirements and how to prepare a battery for charging.
Plugging it in
Your charger should be grounded to reduce the risk
of electrical shock.
Your charger is equipped with an electrical cord that
has an equipment grounding conductor and a ground-
ing plug designed to be used on a 120 volt circuit. The
plug must be plugged into an outlet that has been
properly installed and grounded in accordance with all
local codes and ordinances.
A TEMPORARY adapter may be used to connect the
charger to a two-pole outlet if a properly grounded
outlet is not available. Use the adapter ONLY until a
properly grounded outlet can be installed by a qualified
electrician.
DANGER: Before using an adapter as illustrated, be
certain that the center screw of the outlet plate is
grounded. The green colored grounding clip of the
adapter must be attached by a screw to a properly
grounded outlet. If unsure whether outlet is properly
grounded, contact a professional electrician. If neces-
sary, replace the original outlet cover screw with a
longer one that will secure the grounding clip to the
outlet cover and make a ground connection to the
grounded outlet.
Using an extension cord
The use of an extension cord is not recommended. If
you must use an extension cord, please make sure
that you follow these guidelines:
•Make sure that the pins on charger's power cord fit
firmly into the extension cord, and that the extension
cord fits firmly into the receptacle.
•Use only 3-conductor (grounded) extension cord
when necessary.
• Check that the extension cord is properly wired and
in good electrical condition.
•Make sure that the wire size is large enough for its
length and for the AC ampere rating as specified in
the accompanying chart.
Length of Cord, in Feet 25 50 100 150
AWG* Size of Cord 18 18 16 14
*AWG=AmWicsn Wire Gauge
Preparing your battery to be charged
It is important that you read and follow these guidelines
while you are preparing to charge your battery.
•Make sure that you have a 12 volt lead-acid battery.
• Clean the battery terminals. Be careful to keep
corrosion from getting in or around your eyes.
• If you have a battery with removable cell caps, if
required, add distilled water to each cell until the
battery acid reaches the level recommended by the
manufacturer. This will help purge excessive gases
from the cells. Be careful not to overfill. If you have a
sealed battery without cell caps, no action is neces-
sary, Continue to the next step listed below.
• Take time to read all battery manufacturer's specific
precautions, such as removing or not removing
cell caps while charging, and recommended rates
of charge.
• Wear safety glasses. See additional "Personal Safety
Precautions" on page 2.
•Be sure that the area around the battery is well
ventilated while it is being charged. If ventilation is
poor, gas can be manually blown away by using a
piece of cardboard or other non-metallic material as
a fan.
•If it is necessary to remove the battery from the
vehicle to charge it, always remove the grounded
terminal from the battery first. A spark may be
caused if all accessories in the vehicle are not
completely turned off.
NOTE: A marine battery installed in a boat must be
removed and charged on shore.
5
Using Your Battery Charger
For best results from your battery charger, learn to use it properly. This section tells how to set the controls and how
to charge a battery in or out of the vehicle.
Setting the Controls
SELECTOR SWITCHES:
A3-way switch is used to select the 2-AMP or the
10-AMP charge rate or the ENGINE START feature.
AMMETER:
The AMMETER indicates the measured amount of
amperes being drawn by the battery. When you first
start charging a battery, the reading will be high, with
the needle near 10 using the 10 amp charging rate.
As the battery charges, the needle will fall to about
4 or 5 amps, indicating a charged battery.
At the 2amp charging rate you will see little needle
movement.
When using the ENGINE START feature, the needle will
swing into the Start (red) area of the scale while cranking
the engine.
The percent of charge scale is intended as a visual aid to
help simplify reading the state of charge of the battery.
The meter is scaled for use with the 10 amp charge rate
only. For the 2 amp charge rate use the red triangle. The
percent of charge is based on current drawn by the
battery. For this reason accuracy will vary with the size
and battery type.
Iroll
10AMP 2AMP ENGINE
START
DCAMPS
CHARGE %100 75 50 25 0
0 2 4 6 8 10
Charging Your Battery
Charging a battery in the vehicle:
1. Arrange the power cord and charging leads carefully
to avoid damage that could be caused by the hood,
door, or moving engine parts.
2. Keep clear of fan blades, belts, pulleys, and other
parts that can cause injury.
3. Check the polarity of the battery posts as indicated
on the battery case: POSITIVE (POS, P, or +) and
NEGATIVE (NEG. N or -). NOTE: The positive post
on top-post batteries is usually larger than the
negative post.
4. Identify which battery post is ground or connected
to the chassis. THE NEGATIVE POST IS
NORMALLY THE ONE THAT IS GROUNDED.
5, To charge anegative grounded post system:
Connect the red (POSITIVE) battery charger clamp
to the ungrounded POSITIVE (POS, P, +) post of
the battery. Then connect the black (NEGATIVE)
clamp to a heavy, unpainted metal part of the
chassis or engine block, away from the battery. Do
not connect clamp to carburetor, fuel lines, or sheet
metal parts.
To charge a positive grounded post system:
Connect the black (NEGATIVE) battery charger
clamp to the NEGATIVE (NEG, N, -) ungrounded
NEGATIVE GROUNDED SYSTEM
post of the battery. Then connect the red
(POSITIVE) clamp to a heavy, unpainted metal part
of the chassis or engine block. Do not connect
clamp to carburetor, fuel lines, or sheet metal parts.
IMPORTANT: Wear safety glasses and face away
from the battery while making connections.
6
6. Connect the clamp to the battery post and twist or
rock back and forth to make a solid connection.
This will help keep the clamps from slipping off the
posts and causing sparks.
7. Select the charge rate with the Selector Switch then
plug the power cord into a grounded AC outlet to
begin charging.
8. The charger will not stop when the battery is tully
charged. For this reason it is important to check
charging progress frequently. Overcharging can
damage a battery, you must monitor and unplug
charger when battery is tully charged.
9. When the battery is fully charged, the AMMETER
pointer will fall to about half the charge rate
selected. For specific positions, refer to the
"Ammeter" section in =Using your battery charger"
on a page 6.
10. When the battery is fully charged, unplug the
charger power cord before attempting to disconnect
charger clamps.
11. Standing away from the battery, remove the charger
clamps in this order: (1) from the chassis
connection and, (2) from the battery post or terminal.
12. Clean and store the battery charger in adry location.
Charging your battery outside the vehicle:
1. Remove the battery from vehicle, making sure to
disconnect grounded terminal first with all
accessories and lightsturned off in the vehicle.
2. Check the polarity of the battery posts as indicated
on the battery case: POSITIVE (POS, P, +) and
NEGATIVE (NEG, N, -).
NOTE: On top-post batteries, the positive battery
terminal usually has a larger diameter than the
negative one.
3. Connect the red (POSITIVE) charger clamp to the
POSITIVE post of the battery. Be sure to rock the
clip back and forth to make a solid connection.
4. Attach a 6-gauge (AWG) or a 4-gauge (SAE)
insulated battery cable of at least 24-inches in
length to the NEGATIVE battery post. This cable
will provide a safer connection because arcing and
sparking will occur away from the battery. (The
battery cable is not provided with the charger, but
may be purchased at most automotive accessory
outlets.)
5. Take the other end of the 6-gauge (AWG) or a
4-gauge (SAE) insulated 24-inch cable and,
standing as far away from the battery as possible,
connect the black (NEGATIVE) lead of the charger
to the free end of the cable. Rock the clamp to
make a solid connection.
IMPORTANT: Wear safety glasses and face away
from the battery while making this final connection.
6. Select the rate of charge with the Selector Switch
and plug the power cord ir_o a grounded AC outlet
to begin charging.
POSITIVE NEGATIVE
BATTERY CHARGER
POWER
CORD
TO
POWER
OUTLET
7. The charger will not stop when the battery is fully
charged. For this reason it is important to check
charging progress frequently. Overcharging can
damage a battery, you must monitor and unplug
charger when battery is fully charged.
8. When the battery is fully charged, the AMMETER
pointer will fall to about half the charge rate
selected. For specific positions, refer to the
"Ammeter" section in "Using your battery charger"
on page 6.
9. When the battery is fully charged, unplug the
charger power cord before attempting to
disconnect charger clamps.
10. Stand away from the battery and remove the
charger leads from the NEGATIVE connection first,
then from the POSITIVE battery post or terminal.
11. Clean and store the battery charger in a dry location.
7¸
Calculating charge time
The Chart Method
Use the following table to more accurately determine
the time it will take to bring a battery to full charge.
First, identify where your battery fits into the chart.
•Small batteries -- motorcycles, garden tractors, etc.
-- are usually rated in Ampere Hours (AH). For
example; 5 to 12 AH, or 12 to 32 AH.
Batteries in cars and smaller trucks are usually rated
in Reserve Capacity (RC), Cold-Cranking Amps
(CCA), or both.
• Marine, or deep-cycle batteries are usually rated in
Reserve Capacity (RC).
• NR means that the charger setting is NOT
RECOMMENED.
Find your battery's rating on the chart below and note
the charge time given for each charger setting.
The times given are for batteries with a 50-percent
charge prior to recharging. Add more time for severely
discharged batteries.
SMALL
BATI'ERIES
CAR/TRUCKS
Motorcycle, garden
tractor, etc.
200 - 315 CCA
315 - 550 CCA
550 - 1000 CCA
MARINE/DEEP CYCLE
6-12AH
12 -32 AH
40 -60 RC
60 - 85 RC
85 -190 RC
80 RC
140 RC
160 RC
180 RC
2-4
4-10
11 -14
14 -18
18-35
18
27
30
33
NR
NR
2 - 27/8
27/8- 33/4
3%- 7
31/2
51/=
6
7
The Hydrometer or Electronic Method
To find the time needed to fully charge your battery,
determine the battery's charge level with a hydrometer
or electronic Percent-of-Charge Tester. The following
table will help you convert hydrometer readings to
percent of charge values.
1.265 100% 0%
1.225 75% 25%
1.155 25% 75%
1.120 0% 100%
When you know the percent of charge and the Amp
Hour (AH) rating of your battery, you can calculate the
approximate time needed to bring your battery to afull
charge.
To convert Reserve Capacity to Amp Hours, divide
Reserve Capacity by 2, and add 16:
Amp Hours = Reserve CaDacitv + 16
2
To calculate time needed for a charge:
•Find the percent of charge needed. (A battery at
50 percent charge that will be charged to 100
percent needs another 50 percent (.50).
•Multiply the Amp Hour rating by the charge
needed (.50) and divide by the charger setting
(2 or 10 amps).
•Multiply the result by 1.25 and you'll have the
approximate time needed, in hours, to bring the
battery to full charge.
•Add one additional hour for a deep-cycle battery.
Example:
Amp Hour Ratino x charoe needed x 1.25 = hours
Charger Setting of
charge
100 fAll Ratina_ x .50 (charoe needed) x 1.25 = 6.25
10 (Charger Setting) hours
100 x.50 = 5 x 1.25 = 6.25
10
You would need to charge your 100-Ampere Hour Bat-
ten] for approximately 61/4hours at the 10-Amp charge
rate using the above example.
8
Using the engine start feature
Your battery charger can be used to jump start your
car if the battery is low. Follow these instructions on
how to use the ENGINE START feature.
1. Connect the charger to the battery. (Follow con-
necting instructions given in "Charging Your
Battery" on page 6.)
2. Set the Selector Switch on ENGINE START.
3. Crank the engine for no more than 7 seconds.
If it does not start, wait at least 4minutes before
cranking again. In extreme cold or if the battery is
severely discharged, charge the battery for about 5
minutes in the 10 amp postion, before cranking the
engine.
4. After the engine starts, unplug the charger power
cord from the AC outlet. Then disconnect the
charger from the battery.
IMPORTANT: Do not try to start the engine without a
battery in it. You could cause damage to the electrical
system.
If the engine does turn over, but never starts up, there
is not a problem with the starting system, there is a
problem somewhere else in the engine. STOP crank-
ing the engine until the other problem has been
identified and corrected.
Maintenance and care
A minimal amount of care can keep your battery
charger working properly for years.
1. Clean the clamps each time you are finished
charging. Wipe off any battery fluid that may have
come in contact with the clamps to prevent
corrosion.
2. Coil the input and output cords neatly when storing
the charger. This will help prevent accidental
damage to the cords and charger.
3. Occasional cleaning of the case of the charger with
a soft cloth will keep the finish shiny and help
prevent corrosion.
9
Troubleshooting
Performance problems often result from little things that you can fix yourself. Please read through this chart for a
3ossible solution if a problem occurs.
No ammeter reading.
Circuit breakerin
chargercycles on
and off wifh a clicking
sound.
Ammeter reads less
than selected charge
rate when charging.
Charger makes a
loud buzzer hum.
Short start cycle
when cranking
engine.
Clamps not making good
connection.
2-amp charge rate.
No AC power reaching
charger.
Shorted battery clamps.
Shorted battery.
Charger leads reversed
on battery.
Extension cord too long or
gauge to small.
Battery has weak cell or
sulfated plate.
Battery is partially
charged.
Transformer laminations
vibrate (buzz).
Shorted diode (hum).
Drawing more than 50
amps for a period equal to
or less than 7 seconds.
Failure to wait for 4 minutes
(240) seconds) between
cranks.
SOLUTION/REASON s
Check for poor connection at battery. Make sure clamps
and posts are clean.
Ammeter needle will indicate littleactivity at the 2-amp charge
rate.
Check AC outlet and extension cords for loose fitting plug.
Check for open fuse or circuit breaker supplying AC outlet.
Separate the clamps. Circuit breaker cycles when current
draw is too high.
Check for worn cables and replace if needed.
Have a Sears technician test the battery.
Correct connections.
Use shorter or heavier extension cord.
Sulfated battery will eventually take a normal charge if left
connected. If the battery will not take a charge, have it
tested by a Sears technician.
Continue charging battery.
Continue charging. Buzz is not abnormal.
Have charger tested by qualified technician.
Crank time varies with the amount of current drawn from
the charger. If cranking draws more than 50 amps, crank
time may be less than 7 seconds.
Wait 4 minutes before next crank.
If the above solutions do not eliminate the problem...
call toll-free from anywhere in the U.S.A. or Canada
1-800-SEARS-64
(1-800-732-7764)
7 AM to 4:30 PM CST Monday through Friday
10
S£/ S
OWNER'S
MANUAL
Model No.
200.47003
When requesting service or
ordering parts, always provide
the following information:
•Product Type
• Model Number
• Part Number
•Part Description
10/2/50 AMP
MANUAL
BATTERY CHARGER
ENGINE STARTER
Forinformationabouttroubleshooting
Calltoll-freefromanywhereinthe U.S.A.orCanada
7 amto 4:30pmCSTMondaythroughFriday
1-800-SEARS-64
(1-800-732-7764)
8EAR'8
0000000549-1t95