OWNER'S
MANUAL

Model No.
390.303302
390.303491

CRAFTSMAN
Model No. 390.303302

CAUTION:
Read and Follow
All Safely Rulesand
Operating Instructions
Before FirstUse of
This Product.

CRAFTSMANPROFESSIONAL
Model No. 390.303491

CRAFTSMAN+
PEDESTAL SUMP PUMP
• Safety Instructions

Save ThisManual For
Future Reference.

• Operation
• Installation
• Service
• Repair Parts

Sears, Roebuck and Co., Hoffman Estates, IL 60179
PRINTED

IN

U.S.A.

U.S.A.

Form No.

F642-2001

(Rev. 4/19/04)

CONTENTS
Introduction

INTRODUCTION

........................................................................

2

Warranty ..............................................................................
Safety Rules ..........................................................................
Installation
........................................................................
Service .................................................................................

2
2
3-5
5

Repair

6-7

Parts .......................................................................

Please read our instructions
before you install and use your
new pump; this will help you obtain full value and good service from it. It will also help you avoid needless service costs
that result from causes we cannot control and cannot cover
in our warranty.

+

RULES
Carefully
read and follow
manual
or on pump.

FOR SAFE INSTALLATION
all safety

instructions

in this

warns
injury,

death

[&WARNING t warns
personal

injury,

death

[& CAUTION ] warns
minor

personal

The word
important

injury

about

hazards

or major
about

that

property

hazards

that

or major property
about

hazards

or property

will cause
damage

2,

serious

serious

[.&WARNING] Risk

if ignored.

lows

which

atmospheres.

if pmnp

of electric

needs

shock.

motors

Proceed

are de-

as fol-

servicing:

A. Disconnect
power
to pump
outlet
box before
pulling
pump
cord plug! After plug is pulled, let
pump cool for 20 minutes before attempting
to work
on it.

if ignored.

NOTICE indicates special instructions
but not related to hazards.

Check your local Electrical and Plumbing Codes before
installing pump. You must comply with their rules.

Do not touch an operating motor. Modern
signed to run at high temperatures.

that will or can cause
damage

•

OPERATION

['_WARNING_DO not use in explosive
Pump water only with this pump.

if ignored.

can cause
damage

•

1. Read these Instructions
and Safety Rules carefully.
Failure to follow them could cause serious bodily injury
and!or property
damage.

This is the safety alert symboL
When you see this
symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential
for personal injury!

personal

AND

•

are

Electrically powered
sump pumps normally give many years
of trouble-free
service when correctly
installed, maintained,
and used. However,
unusual circumstances
(interruption
of
power to the pump, dirt/debris
in the sump, flooding that exceeds the pump's capacity, electrical or mechanical
failure in
the pump, etc.) may prevent
your pump from functioning
normally. To prevent possible water damage due to flooding,
consult your local Sears store about installing a secondary
sump pump or a DC backup sump pump. See "Service",
Page 5, for information
about common
sump pump problems and remedies.

B. Take extreme
care when
changing
fuses. To reduce the chance of fatal electrical
shocks, DO NOT
stand in water or put your finger in the fuse socket.
C. Ground
the electrical outlet box.
D.Use

only

a grounded

outlet

for cord plug.

E. Do not handle pump motor with wet hands or when
standing on wet or damp surface, or in water.
3.

NOTICE: This unit is not designed for applications
involving
salt water or brine! Use with salt water or brine will void
warranty.

Never run pump dry. To do so can damage internal parts,
overheat the pump (which can cause burns to people handling or servicing the purnp), and will void the warranty!
[.&WARNING IF IRE HAZARD

- Do not store

or rest ob-

jects on or near motor
or switch
linkage.
Keep
flamLmmble objects
or liquids away from motor.

2

all

PUMP INSTALLATION

4. This pump is recommended
for use in permanent installations only. Do not install on clay, earth, or sand surfaces.
1
A CAUTION j Pump

must

cal) when operating.
switch may overheat

be level

(column

If motor is tilted,
and damage motor.

must

internal

be vertistart/run

ADDITIONAL
INSTALLATION
MATERIALS
SumpFLTtility Pump Hose Kit, SEARS Stock No. 27909, containing 24' of 1-1/4" flexible plastic pipe, a 1-1/4" plastic
adapter and a stainless steel clamp.
Check

Valve, SEARS Stock

No. 2789 or 2792.

THE SUMP
The sump should be located at the lowest place in the basement or area to be drained. Floor drains from other areas in
the basement may be tiled into the sump. Drain tile around
a house foundation can also be tried into the sump, effectively removing water and relieving pressure from this area.
A suitable sump can be a 20" or 24" sewer tile. Sump must
be at least 12" in diameter.
A sump
Consult

cover is desirable
to exclude refuse from the sump.
local code for sump cover specifications.

SPECIFICATIONS
Power

supply

required

....................................

115V, 60 HZ.

Horsepower

(390.303302)

.............................................

1/3

Horsepower

(390.303491)

.............................................

1/2

Motor

duty .........................................................

Liquid Temp.
Individual
Requirement

Range ........................

Branch

Intermittent

Check your local Electrical and Plumbing Codes before installing pump. You must comply with their rules.
Set the pump on the bottom of the sump, making sure that
it sits solidly and is level. Be sure there is enough space
around the pump to allow the switch free movement as
the sump water level changes. Do not install on clay,
earth, or sand.
[A _
Risk of flooding. If a flexible discharge
hose is used, pump may move around in sump
when motor starts. If it moves far enough so that the
switch hits the side of the sump, the switch may stick and
prevent pump from starting. Make sure that pump is secured so that it cannot "walk around" in sump.
NOTE: To avoid backflow into the sump when the pump
shuts off, install a Check Valve, SEARSStock No. 2789, in the
threaded discharge port of pump (390.303302) or 1-1/2"xl1/4" reducer bushing (390.303491). Reducer bushing is included with Model 390.303491. Be sure arrow on check
valve body points away from the pump. This Check Valve is
equipped with an air bleed hole to prevent airlocking the
pump. If using any other check valve, drill 1/8" (3.2 ram)
hole in discharge pipe just above pump body but below
check valve to prevent air locks.
Use 1-1/4" plastic pipe from Hose Kit No. 27909 for the discharge pipe. Run the discharge pipe to the nearest sewer
outlet or other point of disposal. Use the most direct route
with the fewest turns and elbows possible.
Use Teflon tape to seal threads in plastic pipe. Hand tighten
only.

32 ° F to 70 ° F (0°-21°C)

Circuit

20 =to 24"

GFCI Class A ......................................

1/4"

15 Amps

Motor

full load (maximum

- 390.303302)

.............

Motor

full load (maximum

- 390.303491)

............. 7.3 Amps

Sump Cover
\
Basement Floor

3.5 Amps

Discharge

(390.303302)

......................................

1-1/4" NPT

"_ischarge

(390.303491)

......................................

1-1/2" NPT

SewerTile
12" Mm
Sewer Tile , ',',,

20" to 24" Diam.
Figure

I

+
_ g

Concrete

ROD AND FLOAT
SWITCH
INSTALLATION

The switch

2.

float rod into float until it is firmly hand tight.

Slide rod guide over float rod; follow it with a rod stop
bushing (A) set about eight inches down from the top of
the rod.

3.

Slide float rod up through the eye in the switch
a rod stop bushing (B) at the top of the rod.

4.

Open large loop on
column. Fasten with
hangs vertically from
rod guide. Make sure

Adjust rod stop bushings

6.

Lift the rod up and down to be sure the switch
and that the arm does not bind on the rubber
The rod must also move freely in the guide.

7.

Fill the sump and run pump
to check switch operation.

for designed

through

level control.

Switch Arm

When the water rises in the sump, the float lifts the svdtch
rod. The buoyancy will push the switch arm up and turn
the switch on.

3. When the water is pumped out of the sump, the float
drops down again. The weight of the float will allow the
rod and switch arm to lower and turn the drainer switch
off.

DO NOT ALLOW

cycle

Ill

PUMP TO RUN DRY

Pump should not be allowed
To do so voids the warranty

to run dry prior to shutting
and could ruin the pump.

ELECTRICAL

CONNECTIONS

Risk of electric
shock.
The Sump Pump
has a 3-prong
electric
plug. The third prong
is used to
ground
the pump to prevent
possible
fatal shock. The
third prong should
never be removed.
Your electrical
outlet should
be the 3-prong,
polarized
type with an
internal
ground.

DO NOT
Testing

into a 15 amp GFCI protected

USE AN EXTENSION

for Ground

For your safety, check your outlet for ground using a Circuit
Analyzer, (Figure 3). A Circuit Analyzer will tell you by a pattern of lights if the power, neutral, and ground wires are correctly connected
to your outlet. It can also be used to check
other outlets in your home. A Circuit Analyzer is available in
the SEARS Electrical Department.

UL Listed
Analyzer

Rod Guide
Outl_

Figure 3

Figure 2

individ-

CORD.

Sump Cover

Float

off.

adjust the float so this will not happen.

Pump must be wired
ual branch circuit.

III

Float Rod

2.

If necessary,

will click
bushings.

one complete

Rod Sto

Rod Stop (A)

arm. Add

rod guide and mount it around the
screw, making sure that the float rod
the switch and moves freely in the
the rod guide is tightly clamped.

5.

as follows:

1. When the sump is dry, the float rod hangs from the switch
alan. Its weight holds the switch off.

See Figure 2 for stop positions.
1. Thread

unit operates

8650194

Grounding

GENERATOR

Outlet

SIZING

If outlet is not grounded, install a copper wire (at least 14
gauge) from the outlet box, as shown in Figure 4, to a metal
cold water pipe. Use ground clamp on pipe.

Below is the Engine-Generator
Watt rating required
to
power this pump motor. Any additional loads, such as lights,
must be added to the listed load and the generator
sized ac-

IMPORTANT: The cold water pipe you use as a ground
must have metal continuity to electrical ground. If continuity
is interrupted by plastic, rubber, or other electrical insulators; such as hoses, fittings, washers or gaskets (including
water meter or pump), a metal bypass must be used. Any
electrically insulated connector should be jumped (as shown
in Figure 5), with a length of No. 4 wire clamped securely
at both ends.

cordingly.
Pump
Motor HP

Minimum Watt
Rating of Generator

1/3

2,200

1/2

2,800

SERVICE

Outlet
Box

General
AWARNING]Risk
Bare co per wire to

coldwatPe_r
pipe.

6690194

Figure 4

1.

No, 4
Wire

of electric

shock.

When

servicing

pump
always
disconnect
power
to electrical
outlet
and remove
pump
electric
cord from outlet. Inspect
sump pump
and system
components
monthly.
Keep
free of debris
and foreign
objects.

Clamp

If pump

does not operate:

a.

Check

b.

Check for blown fuses or tripped
fuse box/circuit
breaker box.

for loose

plug at electric

outlet.
circuit

breakers

at

c. Be sure nothing interferes with action of float switch.
d. ff a, b, and c above check OK, plug in a light that you
know works, ff it fights, take your pump to SEARS for
service, flit doesn't light, the electrical circuit is faulty;
consult a licensed electrician.

Metal Water
Pipe

Metar
670 01_4

Figure 5

Automatic

Thermal

Overload

2. Pump

Protection

This pump motor has a built:m automatic
thermal overload
protector.
If the motor overheats,
the protector
will open
and cut off power to the motor before the heat damages it
internally.
The overload
will reset automatically
and the
pump will restart after the pump cools down below the danger point.

IA WARNING]DO NOT attempt to work on the pump or
motor if the overload
seems to have tripped. The
motor may restart without warning at any time. You
could be injured and the pump damaged if it starts
when you are working on it.
DO NOT attempt to repair a sump pump. Take it to SEARS
for service by a qualified technician.

starts,

but blows

fuses/trips

circuit

breakers:

After disconnecting
power
to pump, remove
it from
sump. Remove the plate from the bottom of the pump
and make sure that the impeller turns freely. Remove any
debris obstructing
impeller. If pump still does not operate correctly,
return it to your nearest
SEARS Service
Department
for repairs.
3.

Pump

runs, but does not empty
intake

sump:

a.

Clean pump

screen.

b.

Water may be enteO.ng sump
discharge it.

c.

Be sure vertical distance from pump discharge outlet
to discharge
pipe outlet is 18 feet or less for Model
390.303302
(20 feet or less for Model 390.303491).

d.

Be sure discharge

faster than the pump

pipe is not plugged

can

or frozen.

LUBRICATION
Motor has been lubricated
at the factory.
additional
oil. Bronze hearing
in volute
pregnated.
It does not require additional

It does not require
housing
is oil imoil.

Craftsman
Model 390.303302

,,

3

-..

4

9A

6

"-5
659 0594

Key No.
1
2
3
4
5
6
7
8
9
9A
10
11

Part Number
U30-932ZP
RP0005257
RP0005246A
$101-33P
SC004-116
FT0013-63
RP005168S
RP0005249
U30-929ZP
2773
RP0005248
U17-318

• Not illustrated.
** If motor fails, replace entire pump.

Description
Motor with Cord and Switch
Screw #8 x 1/2" Hex Head (2 Required)
Shaft
Column
Impeller Assembly
Screw #8-18 x 3/8 Self Tap
Float
Rod
Rod Guide
Screw #8 x 1" Phillips Head
Switch
Float Stop (2 Required)
Cord and Plug

Craftsman Professional
Model 390.303491
13
10

1
2

12

3
4

I

6
I

7

27121196

Key No,
1
2
3
4
5
6
7
8
9
9A
10
11
12
13

Part Number

Description
Motor with Cord and Switch

U30-946PH
RP0005257
$15-37SS
$1-32B
$5-13P
PS4-17P
U30-571BT
RP0005249
U30-929ZP
RP0005248
FT0013-63
RP005168S
2773
U17-318
U78-130P*

Set Screw (4 Required)
Shaft
Column
Volute
impeller
Base Plate
Screw #8-32 x 1/2 Hex Head (8 Required)
Rod Guide
Screw #8xl" Phillips Head
Rod Bushing (2 Required)
Float
Rod
Switch
Cord and Plug
1-1/2" x 1-1/4" Reducer Bushing

• Not illustrated
* May be purchased locally.
** If motor fails, replace entire pump.
"7

SEARS
OWNER'S
MANUAL

I:RRFTSMRN°
PEDESTAL SUMP PUMP

Model No.
390.303302
390.303491

Forthe repair or replacementpartsyou need
Call7 am - 7 pm, 7 daysa week

1-800-366-PART
(1-800-366-7278)

Forin-homemajorbrandrepairservice
Call24 hours a day, 7 days a week

The model number of

1-800-4-REPAIR
(1-80D-473-7247)

your PedestalSump Pump
will be located on the side
of the motor.
When requesting service
or ordering parts, always
give the following
information:
• Product Type
• Model Number
• Part Number
• Part Description

Forthe locationof a
SearsRepairServiceCenterin yourarea
Call24 hours a day,7 daysa week

1-800-488-1222

Forinformationonpurchasinga Sears
MaintenanceAgreementor to inquire
aboutan existingAgreement
call 9 am - 5 pm, Monday-Saturday

A

,_SSARS

1-800-827-6655

SEARS
Arner_.a's Repair SpecJalists

Sears, Roebuck and Co., Hoffman Estates, IL 60179

U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 8
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Wed Aug 15 00:18:32 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu