Sears Kenmore 758 144151 Users Manual
758144151 758144151 KENMORE HUMIDIFIER - Manuals and Guides L0104162 View the owners manual for your KENMORE HUMIDIFIER #758144151. Home:Heating & Cooling Parts:Kenmore Parts:Kenmore HUMIDIFIER Manual
KENMORE Humidifier Manual L0104162 KENMORE Humidifier Owner's Manual, KENMORE Humidifier installation guides
KENMORE 758.144151 L0104162
758.144151 to the manual c2fd8228-e5d8-4139-ad8b-142bab2532c8
2015-02-05
: Sears Sears-Kenmore-758-144151-Users-Manual-399067 sears-kenmore-758-144151-users-manual-399067 sears pdf
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
f Save this manual for future reference I SEARS owner's manual Stock No. 42-14415 Model No. 758.144151 _J ® QUIET COMFORT WHOLE HOUSE HUMIDIFIER FOR YOUR SAFETY: R EAD ALL INSTRUCTIONS CAREFULLY 13 Gallon Output Innovative Twin Fan Technology • Operating Instructions • Parts List Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part NO, SP6327 Printed in Canada GENERAL SAFETY INSTRUCTIONS Safety Signal Words 4 Keep the humidifierclean. 5. Do not put foreign humidifier. DANGER: means if the safety information is not followed, someone will be seriously injured or killed. WARNING: means if the safety information is not followed, someone could be seriously injured or killed. CAUTION: means if the safety information is not followed, someone may be seriously injured or killed. 1. To reduce the risk of fire or shock hazard, plughumidifierdirectlyintoa 120V, A.C. triceloutlet. Do not use extensioncords. 2. Keep the electric cord out of traffic areas. To reduce the riskof fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters. 3. Always unplug the humidifier before moving it, before cleaning, or whenever the humidifier is not in service. objects inside the 6. Never use your humidifier while any part is missing or damaged in any manner. 7. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running. 8. To reduce the risk of damage to humidifier, unplug humidifier, when water bottles are empty or when the humidifier is not in use. 9. To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands. t0.Note the warning label shown below. WARNING: To reduce risk of fire, elec- I tric shock, or injury always unplug before filling, servic ng or cleaning. Table of Contents Warranty Information .................................. 2 2 3 Humidifier 4 Operations ................................ Assembly .................................................... Location Instructions ............................... Electrical Hook-Up ...................................... To Save a Service Water Fill .................................................. 5-6 Operating Humidifier Controls ................... 7 Manual DWout ............................................. 7 Using Your Humidifier ................................. 8 Operating Tips for Best Performance ......... 8 Replacement and Care of Filters ........... 9-10 Cleaning Your Humidifier ..................... 11-12 Troubleshooting ....................................... 13 Repair Parts ......................................... 14-15 2 General Safety Instructions ........................ To Save A Service Call ............................... Know Your Humidifier ................................. 4 4-5 5 Call Check the following if your humidifier will not operate. 1. Is power cord attached to outlet? 2. Is themeelectrical power to outlet? 3. Is airflow control in operating position? 4. Is humidity control set high enough? 5. Is the cabinet sitting on a level surface? 2 I Know Your Humidifier, Control Panel Cover & Pivoting Lid Removed for Clarity Desired Humidity Controls Fill L Fan Assembly Light \ Bottles Filter Filters: Description 42-14415 Gallon Output/24 Hrs. Capacity of Bottles Sq. Ft. Coverage Fan Speeds Filters 13 2-3/8 Gallons Each 2700 3 4 Yes Yes Yes Rotary Yes Yes 120 A.C. 60 2.88 165 Fill Light Desired Humidity Light Automatic Humidistat Controls CUL Listed AHAM Certified Volts Hertz Amps Watts Based on an area with average insulation and an 8 foot ceiling height. Humidifier Operations Your new Sears humidifier is designed to satisfy home humidity requirements through the principle of evaporation of water in the air. After water is added to the bottle, the filters begin to soak up the water and become totally saturated in approximately 30 minutes. Air is drawn in from the rear of the humidifier and through the filters by means of circulation fans. As air passes through the filters, moisture is absorbed into the air and then released in the form of vapor. No water droplets will enter the home. All evaporation into the air takes place in the humidifier, which means that the residue left by evaporating water is not passed into the home, but remains in the filter. Humidified Air is Then Released Through the Top ii'f,liil Dry Air Enters CAUTION: To reduce the risk of injury, fire or damage to humidifier, use only cleaners specifically recommended for humidifiers. Never use flammable, combustible or poisonous materials to clean your humidifier. To reduce the risk of scalds and damage to humidifier, never put hot water in humidifier. CAUTION: Use only 42-14900 EPA Registered Bacteriostat available from SEARS Retail store. Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers. Assembly Your new Sears Kenmore humidifier is completely assembled fer you to use. Remove the packaging material from inside your humidifier and follow the instructions of this Location owner's manual for proper usage. The packaging material is located under the fan assembly. Remove the packaging material and discard. Instructions WARNING: For your own safety, do not I use humidifier if any parts are damaged or missing. casters to sink deeper into the carpet. If this happens, the water level will be higher towards the front of the humidifier, and lower towards the back. The water level float (located at the rear of the cabinet) may not sense the water so the fill light will be on and the unit will not energize. If this happens, the unit will need to be leveled in order for the humidifier to be energized, it may be necessary to purchase leveling coasters from your local hardware store. The coasters should be positioned under the front two casters of the humidifier. Step 1 Place humidifier on a flat level surface in an area of house where most humidity is needed, or one which would likely result in moist air being circulated throughout the house, such as near a cold air return. Placing the unit level is very important if the humidifier is located on carpeting. NOTE: The 13 gallon humidifier contains water bottles. The weight of the bottles in the front of the cabinet may cause the front 4 Location Instructions (continued) NOTE: Due to release of cool, moist air from humidifier, it is best to direct air away from home thermostat and hot air registers. It is best to position humidifier next to an inside wall. Hot air registers and cold air from outside walls can affect the efficiencies of the controls. Unit should not be placed where warm air from a hot air register blows directTyon unit. Moist air (humidity) produced will disperse intothe whole house, but area closest to the unit will have the highest humidity. If the unit is positioned close to a window, condensation may form on the window pane. If this is not appropdate the unit should be repositioned in another location. Electrical Step 2 The humidifier should be positioned with the back (cord exit side), at least 2 inches away from the wall. Air needs to enter through the Iouvres in the rear panel in order for the humidifier to operate at peak efficiency. --_ "-I At Least 2" From Wall Hook-Up Locate nearest 120V A.C. wall socket in the location desired, preferably on inside wall. Plug in the electrical cord. electrician to install the proper outlet. Do not change the plug in any way. WARNING: To reduce the risk of fire or shock hazard, humidifier should be plugged into a 120VA.C. outlet. Do not use extens on cords To reduce the risk of electrical shock, this humidifier has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse plug. If it still does not fit, contact a qualified Water Fill Fan WARNING: To reduce the risk of shock, I always unplug humidifier before clean- I ing or servicing. I Pivoting lid Removed for Clarity Assembly WARNING: To reduce the risk of fire or shock hazard, do not pour or spill water into control or motor area. Close the control cover. If controls get wet, let them dry completely and have unit checked by an authorized sewice personnel before plugging in. This humidifier is designed for use with the two water bottles th_ are located under the pivoting lid. Open the pivoting lid of the humidifier. Remove the water bottles by lifting them straight up and out of the cabinet. Front of Humidifier 5 Water Fill (continued) Notice the water bottles are designed as right and left hand units. Position them in the correct location so the humidifier can function properly. The water bottles should rest in the front of the cabinet. Each "E-ZFill Side-Cap" must be facing the rear of the unit. ___-'_ Each water bottle is designed with an =EZ-Fill Side-Cap" that is easily removable, Remove the =E-Z-Fill Side-Cap" on the side of the water bottle by twisting counterclockwise. ,_ Rear of _"'_ Humidifier "E-Z-Fill Side-Cap" Should Always Face Rear Place the opening of the water bottle under a water faucet (the bottle should fit under a four-inch clearance faucet). Fill with recommended mixture of cold water and Sears Bacteriostat #42-14900 (if necessary) only. Solid debris could make the valve leak. Turn Counterclockwise ove Cap Install the "E-Z-Fill Side-Cap" by twisting clockwise, Hand tighten only. Check for possible leaks by performing the following: 1. Grasp bottle handle and hold the bottle upright over a sink. 2. Press up on valve cap plunger for about one second to let out a little water. Valve Cap Plunger 3. Release the plunger. 4. Listen for air bubbles. Look for leaks around the "E-Z-Fill Side-Cap". 5. If you hear air bubbles or see leaks, retighten the "E-Z-Fill Side-Cap" and repeat steps 1-4. Wipe off excess water from the bottle. Position the water bottle back into the unit by grasping the water bottle handle and lower it into the cabinet until the bottle sits Pivoting Lid Removed for Clarity on pads at bottom of cabinet. The =E-Z-Fill Side-Cap" must be facing the rear of the cabinet, When positioned properly, the plunger will open and water will flow into the cabinet. The water level will automatically remain at approximately 1/2" until the bottles are empty. The unit is now ready for operation. 6 Operating Humidifier Controls The operating controls of your Kenmore Quiet Comfort whole house humidifier are located on the top center of the humidifier. The controls are found under the smoked control cover, located between the air circulating fans. Fill Light When the humidifier is almost out of water, the Fill light will come on and the fans will automatically shut off. Lift the control cover by placing your finger in the round cutout and lifting. The cover will stay open. Now you can clearly see the control area. Familiarize yourself with the controls and reference the diagram of the control area for the correct naming used in this manual. To Operate Humidity °°oo e MIN 0 MAX • the Controls Control: _bi't Adjust the amount of humidity depending on your needs. The humidifier will turn on and off as required to maintain level of humidity selected. A medium setting is recommended, but there are times when low or high amount of humidity may be preferred. For constant operation of humidifier, MAX allows for the maximum amount of humidity to be evaporated into the air continuously. IMPORTANT: Water damage may result if condensation starts to form on windows or walls. Humidity Control setting should be lowered until condensation no longer forms. Desired eoO°e Humidity Light When the selected humidity level is met, the fans will shut off and the green "Desired Humidity" light will illuminate. When more humidity is called for, the fans will turn on and theI_t will go out. Speed Control The unit is adjusted from "OFF" to "3" with a rotary speed control. The higher the air flow speed, the more water is evaporated and released into the air. Low speed (1) is the quietest and is provided for conditions that may not require as high an evaporation rate. T13 Manual Dryout At the end of the humidification season or if you do not plan to run the humidifier for one week or more, you can override the automatic shutoff function to completely dry the humidifier cabinet out. To do this, simply slide the float retainer located at the back of the humidifier cabinet to the fop position of the slot it is Iocated in. This will hold the float in an upward position and the fans will run until you turn the power oft. NOTE: Be sure to position float retainer to the normal operating mode (lowest position in slot) for humidifier operation. Below is a diagram of the slot the float retainer is located in at the back of the cabinet. MANUAL .<_ t_ DRYOUT OP POSITION IS FOR Bo'n'OM POSITION IS FOR NORMAL OPERATION MODE Using Your Humidifier Step 1 Be sure Step 4 humidifier is full of water and plugged in. Step 2 Set Speed Control _(_ to 1. Step 3 Set Humidity Control position. _'_ to medium NOTE: Humidifier should operate with humidity control on the recommended medium setting. If it does not, the humidity is at a relatively high level. To test the unit under this condition, turn Humidity Control all the way to MAX and unit should begin to operate. After the unit has been tested, set Humidity Control to medium or desired level. Allow 24 hours for humidifier to adjust. if humidity level in home is sufficient, the humidifier wig only operate with Humidity Control set on MAX. If humidifier stops running and the "Desired Humidity" indicator is illuminated, the humidity level is at the normal requirements for that setting or it is adjusting to the home conditions• The chart below shows recommended indoor humidity levels.The figure below shows approximate relative humidity percentages which correspond to the various settings of the Humidity Control. When Outdoor Temperature is: Recommended Indoor Relative Humidity is: -10°F 0°F 10 ° F 20°F & above 20% 25% 30% 35% IMPORTANT: Water damage may result if condensation starts to form on windows or wails. Humidity Control setting should be lowered until condensation no longer forms. _'_ MAX \ Relative Humidity Operating Tips for Best Performance 1. Position the humidifier at least 2 inches from any wall and away from any heat registers. 2. Do not restrict airflow from entering or exiting the humidifier. 3. Use Sears recommended bacteriostat 42-14900 to retard bacteria growth that may cause odors and may be harmful to your health. 4. Perform regular cleaning as instructed in "Cleaning Your Humidifier" section of this manual. 5. Replace the evaporative wicking filters at least once per humidification season or more depending on water conditions in your area. Replacement and Care of Filters WARNING: To reduce the risk of shock] or injury from moving parts, always| unplug humidifier before removing or/ replacing any parts. | CAUTION: To help retard bacteria growth and keep maximum efficiency, the filters should be replaced at least once per season, or more often under hard water conditions. Use Sears recommended replacement filter 42-14911. _,llfilters may be dnsed in clear water onl Fake care not to damage paper. To replace _vaporative wicking filters in your Kenmore Quiet Comfort Whole House humidifier, follow the instructions below. Pivoting Lid 1. Unplug humidifier and proceed to clean. Before removing the filters, we recommend moving the humidifier to an area where floor coverings are not susceptible to water damage, i.e. kitchen or bath areas. Fan Assembly 2. Open the pivoting lid and remove water bottles and set aside. Grasp the fan assembly front center and rear center. Lift off and set aside on a clean fiat surface. The fitter housings are now accessible. fumidifier Cabinet 3. Lift fiifer housing out of cabinet and place where you may work on them comfortably. With a soft, absorbent cloth remove any remaining water or loose mineral deposits not trapped in the filter from the humidifier cabinet. Front of Humidiifer Spring Tabs Filter 4. To open filter housing for easy access to filters: a. Deflect the two spring tabs on top of filter housing. Lift top cover off of the filter housing and set aside. b. Remove the two filters and dispose of properly. Clean internal parts of humidifier per the "Cleaning of Humidifier" section of your owner's manual. 9 Replacement and Care of Filters (continued) m c, Install new filters in the filter housing track with the glue beads of the wicking pad to the inside of the filter housing. Fixed Tabs d. Return the top cover of the filter housing by installing the cover over the fixed tabs on the rear of the lower Spring Tabs _J filter housing and pivoting the cover down over the top of the filters, Snap the cover over the two spring tabs. e. Replace the filter housing in the cabinet. Note: There is a left and a right filter housing. There is also a front and back orientation. To position the filter housings correctly: Humidifier - Make sure the two indents in the cylinder section of the top covers are positioned towards the center of the cabinet. • Be sure that the spring tabs of filter housings are towards front of cabinet. Top Cover indents Towards Center of Cabinet • Align the lower portion of the filter assembly over the six ribs located at the boilom rear of the humidifier cabinet. f. Position fan assembly onto the cabinet. Make sure the fan venturi (lowest cylinder section below the fan) is placed inside the filter housing, g. Replace water bottles. h. Close the pivoting lid. Fiat Portion of Filter Housing Towards Back of Cabinet i. The unit is ready for use or to be stored away for next season. NOTE: For correct operation of the filter housing assembly, filters must be fully contained inside the flange of the top cover. Indents Toward Center of Cabinet Step 4 e. 10 Cleaning Your Humidifier Step 2 To Remove Parts WARNING: To reduce the risk of injury, fire or damage to humidifier, use only cleaners specifically recommended for humidifiers. Never use flammable, combustible or poisonous materials to clean your humidifier. To reduce the risk of scalds and damage to humidifier, never put hot water in humidifier. a. Open the pivoting lid and remove water bottles and set aside. Grasp the fan assembly front center and rear center. Lift off and set aside on a clean flat surface. The filter housings are now accessible. b. Before removing the internal pads of the humidifier cabinet, we recommend moving the humidifier to an area where floor coverings are not susceptible to water damage, i.e., kitchen or bath area. Lift the filter housing assemblies out of the cabinet and set to the side. c. Remove the water level float from the humidifier cabinet by pinching the float retainer to release it from the cabinet. The cabinet should be empty before cleaning. The cabinet consists of the lower areas of the humidifier where the filters are during normal operation time. CAUTION: Local water purity varies from area to area and under certain conditions water impurities and airborne bacteria may promote the growth of microorganisms in the reservoir of the humidifier. To retard bacteria growth that may cause odors and be harmful to your health, use only Sears replacement filters. We also recommend using EPA approved bacteriostat, 42-14900 and humidifier cleaner 42-14713, available at your local Sears store. d. Empty cabinet of any remaining water. e. Proceed to "Bi-Weekly Maintenance" or "End of Season Maintenance." NOTE: If it is necessary to use approved bacteriostat, follow directions correctly. The bottles of the whole house humidifier will hold 2-3/8 gallons of water each. f. Remove old filters and dispose of properly as described on page 9 and 10. Step 3 Install new filters (purchase the correct evaporative wicking filter pads 42-14911 for your humidifier) into the location where the old filters were positioned. Install the filter housings with the new filters into the correct location. Reinstall the water level float. NOTE: Float retainer should be positioned in normal operating mode. Assure that it is positioned in the bottom of the slot in the back of the cabinet. (See page 7 for diagram of slot.) Position the fan assembly on top of the cabinet and return the humidifier to the desired location for use. Step 1 To make cleaning easier, the humidifier cabinet should be empty and completely dried out. To accomplish this, use the following method: a. On the back side of the humidifier cabinet, find the float retainer. In normal operating mode, the retainer will be positioned in the bottom of the slot in the cabinet. Push the retainer up to the top slot position in the cabinet until it locks in place. (See "Manual Dryout" section on page 7.) b. Allow the humidifier to run until there is no water left in the cabinet. Refill humidifier bottles with fresh cool water and return them to the cabinet. Plug the unit into a 120 volt A.C. power outlet and set the controls per the "Operating Humidifier Controls" section of this manual. c. Unplug humidifier. WARNING: If humidifier is not un- plugged, fan could start after housing is removed. 11 Cleaning of Humidifier (continued) End of Season Bi-Weekly Maintenance Removing Scale 1. Fitl the humidifier cabinet with one 8 oz. cup of undiluted white vinegar. Let solution stay 20 minutes. 2, Clean all interior surfaces with a soft brush. Dampen a soft cloth with undiluted white vinegar and wipe out the cabinet to remove scale. 3. Maintenance 1. Follow "Bi-Weekly instructions at end season. Maintenance" of humidification 2, Remove and throw away filters. 3. Let humidifier dry completely before storing. Do not store with water inside cabinet or water bottles. 4, Store in cool, dry location. 5. Install a new filters in clean humidifier before next season begins. Rinse thoroughly with clean warm water to remove scale and cleaning solution before disinfecting cabinet. 6. "Bi-Weekly" is also recommended if you do not plan to rue the humidifier for one week or more. 4. Dust the fan assembly and outside surfaces with a soft cloth only. Disinfecting Humidifier Cabinet and Water Bottles 1, Fill humidifier cabinet with 1 teaspoon chlorine bleach in 1 gallon of water, Let solution stay for 20 minutes, swishing every few minutes. Wet all surfaces normally exposed to water. 2. Empty humidifier cabinet after 20 minutes. Rinse with water until bleach smell is gone. Allow unit to dry out completely. 3. Water bottles should be cleaned in the same manner. 12 Troubleshooting Trouble Probable Cause Remedy Unit will not run and neither control panel light is illuminated, • No Power. Unit will not shut off. • Slide float retainer down to • Float retainer is positioned in "Manual Dryout" position. normal operation mode. Refer to "Manual Dryout" • Float is not free. section on page 7. • Check 120 volt power source. Free float from obstruction. Unit will not dry out completely. • Float is positioned in normal operation mode. This is normal. A small amount of water remains in the cabinet after Fill Light comes on, Position float retainer in "Manual Dryout" position to completely dry out. See page 7. Bottles continue to empty. • Air is entering water bottles. Check "E-Z-Fill Side-Caps" and valve assembly caps to ensure tightness. Check for leak in water bottJes. Ensure gaskets for "E-Z-Fill Side Caps" are in place (son repair parts list). Neither bottle emptying. • Dirty filters Change to fresh new filters. (42-14911 ) Check orientationof bottles. RepesitJon so that bottle cap plunger (stem) is depressed by post in bottom of cabinet. • Bottle cap plunger missing post in bottom of cabinet Left bottle not emptying, • Right bottle contains water The humidifier is designed so the right bottle empties first. Continue to run until fill light comes on. Right bottle not emptying • Wrong valve assembly cap on right bottle • Ensure that the valve assembly cap on the dght bottle has a yellow stem. Fill Light turns on before bottles are empty. • Unit is not set up on a level surface. (Float will not sense water at the rear of the cabinet.) • Position unit level. (Some carpet padding may allow unit to sit lower in front than rear with the additional weight of water bottles in the front of the cabinet. Install coasters under front casters. CAUTION: Use only 42-14900 EPA Registered Bacteriostat available from Sears Retail store. Use of other water treatment products may damage the filter elements. Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers. 13 28 27 24 23 Key No. t. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Part No. 823884 823730 823724-1 828381 828429 8264OO 823912 825858 825858-1 13805-02 823728 826401 824101-1 828200 824690 828192 828191 Description Key No, Cover, Dust Lid, Stationary Lid, Pivoting Knob Label, Control Cover, Control Switch, Rotary Light, Fill Light, Humidity Humidistat Switch, Micro Enclosure, Electronics Retainer, Float Float, Water Level "Easy-Fill Side-Cap" Bottle, Left (IncludesKeyNo's15 &18) Bottle, Right (IncludesKeyNo's15& 1E 18 19 20 21 22 23 24 25 26 27 28 30 31 32 33 - * Standard Hardware Item - May be purchased locally. Pad No. 509229-1 828199-1 823726 STD601107 828515 823849 42-14911 828197 828534 828115-1 822406-1 828196 824120 826367 STD610603 SP6327 Description Cap, Valve Assembly Cabinet Rail, Kick * Screw, Pan Hd. Ty "AB" #10 x 3/4 Caster, Twin Wheel Support, Filter Lower 1"Filter,Evaporative Support, Upper L.H. Filter Support, Motor Motor (Includesmountinghardware) Fan Support, Upper R.H. Filter Cord w/Plug Retainer, Micro Switch * Screw, Pan Hd. Type AS #6 x 3/8 Owner's Manual (not illustrated) Stock }tern - May Be Secured Through Sears Retail and Catalogue Stores. O z == c i.= For the repair or replacement parts you need Call7 am - 7 pm, 7 days a week 1-8OO-366-PART (1-800-366-7278) For in-home major brand repair service Call 24 hours a day, 7 days a week 1-800-4-REPAIR (1-800-473-7247) For the locationof a Sears Repair Service Centerin your area Call 24 hours a day, 7 days a week ,_pm_h , 1-800-488-1222 For information on purchasinga Sears MaintenanceAgreementor to inquire about an existingAgreement Call 9 am - 5 pm, Monday-Saturday 1-800-827-6655 SEARS ,4r_eijca S V]ep_r Sp_c_IIStS 1he model number will be found on the Humidifier identilication label. When requestingservice or ordering pads, always providethe following information: • ProductType * Model Number • Part Number • Part Description © 2000 Emerson Electric CO. Sear_, Roebuck Part. No. SP6327 and Co., Hoffman Form. Estates, No. SP6327 IL 60179 U.S.A. Printed in Canada 11/00
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 16 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Tue Aug 14 12:08:03 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools