Digital Access Keypad Manual User Operation for the SK-1131-SQ 1. Using the User Codes: Note: A. User codes operate the door (4-8 digits long). Press u u u u B. The # key must be pressed also if the keypad is in manual-entry mode. Press u u u u u u u u indicates the user code. Note: X X X X indicates the master code. # 2. Using the Master Code: The Master Code can be used to operate any output. Press X X X X # 1 (Relay output #1) Press X X X X # 2 (Relay output #2) Press X X X X # 3 (Relay output #3) MANUAL 3. Using the Inhibit/Lockout Code: Please contact your installer for an explanation of inhibit mode and its operation. SK-1131-SQ 4. Using Duress Codes: For a full explanation of duress codes and their uses, see pg. 12. Digital Access Keypad with 3 Outputs 5. Delete/Add/Change User and Master Code: A. Enter the Master Code first, followed by the * key (If you forgot the master code, see page 15 for more information. Press X X X X * B. Changing/Adding Users: Press 1 00-99 (user ID) u u u u (user code, 4-8 digits) # (for relay output #1) Press 2 0-9 (user ID) u u u u (user code, 4-8 digits) # (for relay output #2) Press 3 0-9 (user ID) u u u u (user code, 4-8 digits) # (for relay output #3) C. Deleting Individual Users: Press 1 00-99 (user ID) # (for relay output #1) Press 2 0-9 (user ID) # (for relay output #2) Press 3 0-9 (user ID) # (for relay output #3) D. Changing the Master Code: Press 0 X X X X # E. To exit programming mode, press the * key. WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else. NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM. SECO-LARM® U.S.A., Inc. 16842 Millikan Avenue, Irvine, CA 92606 Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 Website: www.seco-larm.com E-mail: sales@seco-larm.com ® PIHAK1 MT_08Keypad2sEmail.pmd SECO-LARM U.S.A., Inc. Page 16 Digital Access Keypad Manual Digital Access Keypad Manual TABLE OF CONTENTS Introduction ................................................................................................................ Dimensions ................................................................................................................ Unique features ......................................................................................................... Wiring - Basic diagram .............................................................................................. Specifications ............................................................................................................ Wiring -- Example, with inhibit control authorized ................................................... Wiring -- Example, with connection to lock device and alarm arm/disarm ............. List of user codes worksheet .................................................................................... Wiring -- Mantrap using two keypads ...................................................................... Wiring -- Auxiliary accessories ................................................................................ Programming notes ................................................................................................... LED and buzzer indicators ........................................................................................ User programming ..................................................................................................... Installer programming ............................................................................................... Reprogram the keypad (certain data) ....................................................................... Reprogram the keypad (complete data refresh) ....................................................... Delete user ................................................................................................................ Master code bypass (DAP jumper) ........................................................................... User operation ........................................................................................................... REPROGRAM THE KEYPAD (CERTAIN DATA) 2 2 3 4 5 6 7 8,9 10 11 12 12 13 14 15 15 15 15 16 To change certain data in the keypad (such as to delete or change user codes), do the following: 1. Enter program mode by keying in the master code and the X X X X * DIMENSIONS 27 / 8 " (73mm) 13/8" (34mm) PARTS LIST Keypad x 1 Back box x 1 Diode x 1 Use the programming instructions on page 13 and 14 to make any changes to the keypad's data. 3. Exit the programming mode by pressing the Mounting screws x 2 * key. REPROGRAM THE KEYPAD (COMPLETE DATA REFRESH) Sometimes it may be necessary to completely erase all current data (except the master code) and input new data. An example of when this may be necessary is the sale of a protected building to a new owner. In such a situation, do the following: 1. Enter the programming mode by keying in the master code and the and the # key, then enter the refresh code, * 8 9 0 1 key: X X X X * The keypad is now in the programming mode. 8 9 0 1 # All old data is cleared and the keypad is ready for new data. NOTE: The master code does NOT change. 2. Use the programming instructions on pages 13 and 14 to enter the keypad's data. 3. Exit the programming mode by pressing the * key. DELETE USER To delete a user who has left the company or who no longer has authority to enter the protected area: 1. Enter program mode by keying in the master code and the 2. 3. * * key: The keypad is now in the programming mode. Enter the output # and user ID number and the # To delete user ID 05 from output #1, press 1 0 5 To delete user ID 1 from output #2, press 2 1 # . To delete user ID 7 from output #3, press 3 7 # . * key. Exit the programming mode by pressing the key: # . MASTER CODE BYPASS (DAP jumper) If the master code is forgotten or does not work, use the DAP (direct access to program) jumper to override the forgotten code and permit direct entry into the programming mode as follows: 1. Disconnect the power supply. 2. Move the DAP jumper from OFF to ON. 3. Reconnect the power supply. Keypad active The keypad will start beeping. or alarm output 4. Move the DAP jumper back to the OFF position. selection jumper The keypad will stop beeping as soon as the jumper is removed. Door sensing 5. The keypad is now in the programming mode, ready to (-) AC/DC ON OFF receive new programming data. (+) AC/DC 6. Re-program the keypad as shown starting on page 13. KEY AL EG In - Egress NOTE -- A new master code may be programmed to replace the ON OFF N.O. Relay Relay one that was lost or forgotten. Note that the sequence for Tamp C. 2 1 replacing the old master code is as follows: DAP Installation screws x 2 45 / 8 " (117mm) key: 2. X X X X INTRODUCTION The SK-1131-SQ is the ideal keypad for office, commercial, and home security installations. This selfcontained security keypad has built-in 5-Amp and 1-Amp relay outputs and a transistor ground output for maximum flexibility for connecting to electronic door strikes, door alarms, door chimes, alarm control panels, or other security and access control applications. The outputs can be programmed for timed (1-999 seconds) or ON/OFF operation. The SK-1131-SQ can be programmed for up to 100 4-digit to 8-digit user codes for the primary output, and up to 10 4-digit to 8-digit user codes for each of the other two outputs. All programming and code information is stored in non-volatile EEPROM memory to protect the data in case of power loss. * The keypad is now in the programming mode. K OR A DAP ENFORCER ® N.C. 13 / 4 " (44mm) Page 2 Option* Key in new code Confirm Exit 0 X X X X # * 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 *Zero "0" is for new master code only; see page 13 for other options. SECO-LARM U.S.A., Inc. Page 15 Digital Access Keypad Manual Digital Access Keypad Manual INSTALLER PROGRAMMING These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function. Enter Programming Mode Enter Master code (DEFAULT: 0 Confirm X X X X * * *Key in the Master Code. Note: For first-time use, Master code is Data Refresh Option Confirm 8 9 0 1 # Confirm # 4 1 # 1 to 999 # 5 1 6 0 # 1 to 999 # 6 1 # Wrong Code Lockout Option # of tries Confirm 7 0 7 1 7 2 5 to 10 # # 7 6 0 0 Door Forced-Open Alarm Option Code entry Confirm 8 0 { 1 # 0 # Output Activation Announcer Option Code entry Confirm 8 1 { 1 # 0 # 0 0 0 0 (DEFAULT: Momentary, 1-sec. output for all three outputs) Function Relay #1, momentary mode, from 1 to 999 seconds Relay #1, shunt mode (ON/OFF) Relay #2, momentary mode, from 1 to 999 seconds Relay #2, shunt mode (ON/OFF) Output #3, momentary mode, from 1 to 999 seconds Output #3, shunt mode (ON/OFF) (DEFAULT: 10 tries / 30 seconds) Function After 10 successive wrong codes, 30-second lockout After 10 successive wrong codes, Duress activated After 5 to 10 wrong codes, 15-min. lockout - Can reset with Master Code None of the above (DEFAULT: Disabled) Function Door forced-open alarm is enabled Door forced-open alarm is disabled (DEFAULT: On) Function 1-sec. beep notifies the user to open the door when the output relay is activated with the user code or egress button. Use with a locking device which gives no sound when it activates, such as a magnetic lock. The beep is disabled, replaced by 2 short beeps for valid user codes. User Code Entry Mode Option Code entry 8 2 { 8 3 { (DEFAULT: Manual) Confirm 1 # 0 # Keypress Beeps Option Code entry Function Auto Entry Mode is selected. The # key that follows the user code is NOT required in code entry. The User Codes MUST be set to the same digit length as the Master Code, from 4-8 digits. Manual Entry Mode is selected. The # key that follows the user code is required in code entry. The User Codes can be 4-8 digits, but not necessarily all of the same length. (DEFAULT: On) Confirm 1 # 0 # Door Propped Open Alarm Timer Option Code entry Confirm 0 # 9 1 to 999 # { ) Function Clears all previously stored data. Configure Relay Outputs Option Output time 4 0 1 to 999 5 0 0 0 0 Function Enter into programming mode Function Keypad beeps when a key is pressed. Silent operation -- keypad does not beep when a key is pressed. (DEFAULT: Off) Function No door propped open alarm Allowable time from 1 to 999 seconds that the door can be left open before the door propped open alarm starts Exit Programming Mode Confirm Function Exits programming mode, returns keypad to normal operations * Page 14 SECO-LARM U.S.A., Inc. UNIQUE FEATURES • 12-24V AC/DC universal power -- No programming or jumpers needed. • Mantrap -- Each keypad can be used as a stand-alone keypad. However, the mantrap feature uses two keypads to protect an area with two doors by ensuring that only one door is open at a time. With the mantrap interlock functions, when a user keys in the code to open one door, a signal is sent to disable the second keypad, thereby preventing access through the second door until the first door is closed. • Relay output #1 inhibit control -- Relay output #1 is typically used for a door strike. If the keypad is set to the "inhibited" mode, relay output #1 will not operate. This increases the security of the protected premises during the time it is not expected to be occupied, such as during evening or weekend hours. An authorized user can enable or disable the inhibit control by using the code for relay output #2 or output #3 at any time, depending on how installed. • Door forced open warning -- When used with an optional magnetic contact, the keypad beeps continuously for 1 minute if the door to the protected premises is forced open without using a valid user code. The warning can be stopped at anytime by keying in any output #1 user code. • Door propped open warning -- When used with an optional magnetic contact, the keypad beeps continuously if the door is propped open after the allowed open time. The allowable open time is programmable. The warning stops when the door is reclosed. • Auto or manual code entry checking: o Auto code entry checking mode -- When all the user codes have the same number of digits, the keypad will activate automatically when the code is entered. There is no need to press the "#" key. This is convenient for the users. o Manual code entry checking mode -- The user codes can vary in number of digits, and the user must press the "#" key when finished entering the code. This increases security. • Keypad active output -- This NPN transistor open collector ground (-) output activates for 10 seconds when any key on the keypad is pressed. This can be used to trigger a video recorder or turn on a light, or to signal a guard that someone is entering the protected premises. • Alarm output -- When used with an optional magnetic contact, this NPN transistor open collector ground (-) output can be connected to trigger an optional alarm control panel if a protected door is forced open or propped open. • Door auto relock -- This can be programmed to relock an open door either when the programmed relock time expires or immediately after the door is closed, depending on which occurs first. This prevents unwanted "tailgate" entries, which can happen if an unauthorized person tries to follow an authorized person through the door. • Duress output -- This NPN transistor open collector ground (-) output can be used to trigger a silent alarm if an authorized user is forced under duress to use the keypad. The duress output is activated by adding 2 to the first digit of any user code for output #1. In this case, the protected door opens as it would normally, but a signal is quietly sent to a remote device to call for help without alerting the unauthorized person. • Backlit keypad -- The keypad is backlit to increase nighttime visibility. For convenience, the lighting intensity will increase for 10 seconds after any key is pressed. Page 3 ` ` ` $#9'& ` BBBBBB*5(< BBBBBBBBBBBBBBBBBBBBBBBBBBBBB.H\SDGJUHHQ/('JURXQGLQSXW BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB %/$&. BBBBBBBBBBBBBBBBBBBBBBBBBB &RQQHFWWRWKH1&WDPSHUFLUFXLWRIDQ BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1&WDPSHU BBBBBBBBBBBBBBBBBBBBBBBBB DODUPFRQWUROSDQHOLIGHVLUHG BBBBBBBBBBB5(' BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB1&WDPSHU ` ``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age 4 :,5,1*%$6,&',$*5$0 Digital Access Keypad Manual Digital Access Keypad Manual SECO-LARM U.S.A., Inc. PREPARING TO PROGRAM THE KEYPAD To program the SK-1131-SQ, first determine the following information: 1. The master code -- Allows the system administrator to program or operate the keypad. 2. The user code or codes -- Allows users to use the keypad's functions. 3. Configuration of the relays and outputs -- For relay output #1, relay output #2, and output #3, determine whether the output should operate from 1 to 999 seconds and then turn OFF (momentary mode), or turn ON/OFF via the code (shunt mode). 4. Result of improper code entry -- Choose between a 30-second code lockout, duress output, a 15minute code lockout, or no reaction. * Note: When X X X X appears in the instructions, it indicates master code entry. GETTING STARTED A master code is required to program the keypad. The default master code is set to "0000." To change the master code, go to page 15 and follow the instructions for "MASTER CODE BYPASS (DAP jumper). Once the master code is set, review the programming options and decide exactly what the keypad will do, including the format of the user access codes as well as how the keypad responds via the relay output, buzzer and LEDs. Note that in every case the basic steps for programming are: 1. Enter the master code, followed by the * key, which puts you in programming mode. 2. Enter the programming codes defined in the various sections as needed, followed by the# ENTER PROGRAMMING MODE Enter Master code Confirm X X X X * Note: For first-time use, Master code is Option 0 1 2 3 Option 1 2 3 User ID 00 to 99 0 to 9 0 to 9 User ID 00 to 99 0 to 9 0 to 9 Access code 4 to 8 digits 4 to 8 digits 4 to 8 digits 4 to 8 digits X X X X Confirm # # # Confirm 1. Enter programming mode: Enter Master code Confirm * # # # # key. 3. Enter the * key again to exit programming mode. Note: A rapid string of 5 beeps and/or 5 LED flashes indicates an error, while 2 beeps indicates that the entry has been accepted. USER PROGRAMMING Function Enter into programming mode 0 0 0 0. ADDING OR CHANGING MASTER AND USER CODES Function Master Code Up to 100 User Codes for relay output #1, with duress feature Up to 10 User Codes for relay output #2 Up to 10 User Codes for output #3 Note: No user code may be the same as the master code. Note: For User ID, key in the number of the user. For Access Code, type in the code for that particular user. DELETE A USER To delete a user who has left the company or who no longer has authority to enter the protected area: Function Enter into programming mode 2. Delete code: Function Deletes specific user ID from output #1 Deletes specific user ID from output #2 Deletes specific user ID from output #3 EXIT THE PROGRAMMING MODE BY PRESSING THE " " KEY * Page 13 Digital Access Keypad Manual Digital Access Keypad Manual PROGRAMMING NOTES 1. Master Code: The SK-1131-SQ comes pre-programmed with the Master Code set at 0000. Additional codes and/or data should be programmed at the owner's discretion. However, to ensure security, program a new personal Master Code to replace the factory-set Master Code as soon as possible. 2. Factory defaults: Master code 0000 __________________________________________________________ User code length 4 to 8 digits __________________________________________________________ Main relay output time 1 second __________________________________________________________ Auxiliary relay output time 1 second __________________________________________________________ Transistor ground output time 1 second __________________________________________________________ Wrong code lockout 10 tries / 30 sec. Door forced open alarm disabled __________________________________________________________ Output activation announcer ON __________________________________________________________ User code entry mode manual __________________________________________________________ Keypress beep ON __________________________________________________________ Door propped open alarm OFF __________________________________________________________ Silent operation OFF 3. Code operation: User codes are each four to eight digits and are assigned to two-digit IDs. If all the codes have the same number of digits, the keypad can be programmed for whether the # key must be used or not after entering the code (see programming, option 820 or 821, page 14). The administrator can easily delete the code of one user via the two-digit ID, if the user is no longer authorized to enter a protected area, without the need to teach the new code to all the other users. Relay output #1 allows up to 100 user codes, while relay output #2 and output #3 allow up to 10 user codes each. 4. Using Duress Codes: Duress codes are used to activate a separate device silently to alert a guard or other personnel that a user is operating the keypad under threat. The keypad operates as normal, but a signal is sent to alert others. Duress code is for output #1 only. Duress codes do not need to be programmed. All user codes are automatically turned into duress codes by increasing the first digit of a user code by the number 2. The code is entered the same way as a regular user code. For example: User code 4468 can be entered as duress code 6468 User code 9843 can be entered as duress code 1843 User code 8181 can be entered as duress code 0181 NOTE: If a user code is programmed, its duress code is unique and cannot be programmed as another user code. For example: If user code 4468 is programmed, its duress code of 6468 is automatically programmed. A user code of 6468 cannot be programmed. LED INDICATORS Green LED -- Does not have a pre-determined function. Instead, connect to a switch or output via the grey and green wires in the wire harness. Red LED -- Does not have a pre-determined function. Instead, connect to a switch or output via the light blue and yellow wires in the wire harness. Auxiliary red/green LED -- Flashes green to show the keypad status (see below). It also lights red when the white wire in the wire harness is connected to ground (-) to show, for example, that an output is activated. BUZZER AND LED SIGNALS Red/ The keypad's built-in buzzer and the auxiliary red/green LED can signal the following: STATUS BUZZER TONES* AUX. LED FLASHES _____________________________________________________________________________________ 1. In programming mode --ON _____________________________________________________________________________________ 2. Successful key entry 1 beep 1 flash _____________________________________________________________________________________ Red Green 3. Successful code entry 2 beeps 2 flashes _____________________________________________________________________________________ 4. Unsuccessful code entry 5 beeps 5 flashes _____________________________________________________________________________________ 5. DAP jumper not replaced Continuous beeps Continuous flashes _____________________________________________________________________________________ 6. In standby mode --1 flash in 2-sec. intervals _____________________________________________________________________________________ 7. Output relay activated 1-sec. long beep** Green 1 2 3 4 5 6 7 8 9 * 0 # SPECIFICATIONS Power: • Operation voltage -- 12-24 Volts AC/DC. No jumper needed to set voltage. • Stand-by current drain -- 10mA @12VDC. • Active current drain (press keypad key) -- Under 30mA. • Active current drain (one relay activated) -- Under 80mA. • Active current drain (two relays activated) -- Under 130mA. Outputs: • Relay output #1 -- 5A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second timed output or shunt (start/stop) output. Three terminals. • Relay output #2 -- 1A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second momentary output or shunt (start/stop) output. Three wires. • Output #3 -- Transistor ground, max. 100mA @ 24VDC, programmable for 1 to 999 second momentary output or shunt (start/stop) output. Single wire. • Tamper output -- N.C. output. Connect to tamper circuit of alarm control panel. Two wires. • Keypad active or alarm output -- Transistor ground, max. 100mA @ 24VDC. Switches to ground (-) for 10 sec. when a key is pressed (keypad active output), or switches to ground (-) to indicate a door was forced open or propped open (alarm output). Single wire. • Mantrap (interlock) control output -- Outputs ground (-) for five seconds after relay output #1 is activated, continues while the door is open. Use to disable a second keypad during this time. Single wire. • Ground output -- Steady ground (-), 100mA @ 24VDC. Single wire. • Duress output -- Transistor ground (-), 100mA @ 24VDC. Single wire. Inputs: • Power -- 12-24Volts AC/DC. Two wires. • Egress -- N.O., ground (-). Single wire. • Door sensor input -- N.C., ground (-). Connect to an N.C. magnetic contact to show if door is opened or closed, or connect to ground (-) if not used. Single wire. • Green LED input -- Connect to operate green LED as needed. Two wires. • Red LED input -- Connect to operate red LED as needed. Two wires. • Auxiliary LED input -- Connect to (-) to turn the center LED to red as needed. Single wire. • Relay output #1 disable input -- Connect to ground (-) to prevent relay output #1 from operating, or to the mantrap (interlock) control output of another keypad to disable output #1 while the other keypad is active. Single wire. Code Operation: • Auto or manual code entry. Up to 100 user codes for relay output #1, up to 10 user codes for relay output #2, up to 10 user codes for output #3. 111,110,000 possible user code combinations. Auto refresh time during code entry: • Max. 10 seconds to enter each digit. • Max. 30 seconds to enter each code. Dimensions (keypad with back box): • 4-5/8" x 2-7/8" x 1-7/8" (117 x 74 x 48 mm). Weight (keypad with back box): • 6.3 oz. (180 grams). ENFORCER --- NOTE: * The buzzer can be disabled through programming option 83. ** The output relay activated beep can be disabled through programming option 82. Page 12 SECO-LARM U.S.A., Inc. Page 5 Digital Access Keypad Manual Digital Access Keypad Manual WIRING: WIRING: Example Wiring, with Inhibit Control Authorized Auxiliary Accessories 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 OUTPUT 3 ALARM CONTROL PANEL (1) RED (2) BLACK (3) (4) (5) (6) (7) O/P 1 Disable RED LED TAMPER N.C. WIRE HARNESS (--) (+) (--) (+) RED LED (+) 4 GREEN LED (+) (--) Door 12~24V AC/DC Sens GREEN LED OUTPUT 1 EG N.C. C. N.O. IN 24-hour N.C. protection zone N.C. N.O. OR (for DC Diode use only) 1N4004 Cathode Egress button (inside the N.O. protected premises) DURESS OUTPUT WIRE HARNESS LEDs: Each LED requires a 1.5K-Ohm series resistor for 24V operation. N.O. ALARM CONTROL PANEL (10) (11) (12) (13) (14) (15) YELLOW GREEN (16) WHITE/ORANGE Additional egress buttons can be connected in parallel as needed Note: • Connect a 1N4004 diode as close as possible to and in parallel with the DCpowered electromagnetic or electric lock. This absorbs possible electromagnetic interference to prevent operation of the lock from damaging the keypad. A 1N4004 is not required for AC-powered locks. • Connect the ground (-) terminal of the keypad to earth to prevent electrostatic discharge from damaging the keypad. • The connection of relay output #1 disable to output #3 as shown above is optional. When so wired, output #3 is the inhibit control. To use, program output #3 for shunt on/off operation. When output #3 is ON, relay output #1 will not work. For example, this can be used to prevent users from entering the protected premises during the evening or weekend. See programming option 61. • As wired, the green LED lights while relay output #1 is activated to activate the lock. • As wired, the red LED lights to show that relay output #1 is disabled by the activation of output #3. • Tape all unused wires to prevent short circuits. WARNING: • If the inhibit control is used, all personnel must exit the protected premises before output #3 is activated. Otherwise, personnel in the protected premises will not be able to exit until output #3 is turned OFF. • The user code for output #3 in this case should be given only to personnel authorized to enter the premises any time. It should not be given to other users. 24-hour N.O. protection zone, max. 100mA DOOR SENSING DOOR -- REMARKS: Output relay #1 N.O. output for fail-secure lock. N.C. output for fail-safe lock. -- 12VDC power supply (--) + + Required for: MAGNETIC DOOR CONTACT (N.C.) GND SENS Electric Lock • • • • Door Auto Relock Door Forced-open Alarm Door Propped-up Alarm Mantrap (Interlock) Control KEY ACTIVE or ALARM OUTPUT +12V (3) (4) 1.5k (5) (6) LED (7) (8) PINK (9) +12V (3) (4) (5) (6) (7) (8) PINK (9) Low power piezo buzzer OR (See page 15 for jumper selection) N.O. relay contact Isolation relay The Key Active Output will switch to ground () for 10 seconds whenever a key is touched. Use to turn ON an LED and/or a small buzzer to notify a guard, or to energize a relay to switch ON lights or CCTV camera. Only one connection option is recommended. Make sure the current does not exceed the maximum rating of 100mA. An external power supply and isolation relay are necessary to drive high power devices such as lights or CCTV cameras. RELAY OUTPUT #2 -- Example, to shunt an alarm N.C. zone WIRE HARNESS (8) (9) WHITE/BROWN (10) BLUE (11) (12) WIRE HARNESS To protection zone of an alarm control panel N.C. Use Normally Open (N.O.) output contact to shunt a Normally Closed (N.C.) protection zone of an alarm system. Set relay output #2 to Start / Stop mode (programming option 51) N.C. magnetic contact Wire Harness Page 6 SECO-LARM U.S.A., Inc. Page 11 Digital Access Keypad Manual Digital Access Keypad Manual WIRING: WIRING: Example Wiring, Mantrap Using Two Keypads Example Wiring, with Connection to Lock Device and Alarm Arm/Disarm 1 DOOR 1 2 15 16 N.O. Common GND O/P 1 Disable Electric Lock 5 6 7 GREEN LED (--) + 8 9 10 11 12 Common GND 13 14 15 16 1 2 3 4 5 6 7 -- 8 REMARKS: Output relay #1 N.O. output for fail-secure lock. N.C. output for fail-safe lock. -- 12VDC power supply 9 10 Additional egress buttons can be connected in parallel as needed N.O. 11 12 OUTPUT 4 13 14 15 16 ALARM CONTROL PANEL WHITE/ORANGE N.O. Duress -- To 24-hour N.O. zone YELLOW GREEN (--) Com gnd (--) of keypad & alarm PURPLE N.C. BLUE N.O. WHITE/BROWN COM YELLOW (+) LIGHT BLUE (--) GREEN (+) GREY (--) BLACK RED REMARKS: Output relay #1 N.O. output for fail-secure lock. N.C. output for fail-safe lock. LEDs: Each LED requires a 1.5K-Ohm series resistor for 24V operation. Interlock -- Each keypad can be used as a stand-alone keypad. The mantrap feature is for a protected area with two doors to ensure only one door is open at a time. With the mantrap feature, when a user keys in the code to open one door, a signal is sent to the second keypad to disable it, thereby preventing access through the second door until the first door is closed. Note: PLEASE ALSO REFER TO THE NOTES ON PAGE 6 FOR MORE GENERAL INFORMATION. • Use an N.C. magnetic contact or some other N.C. device to detect whether a door is opened or closed. Do this for the two entrances to the protected premises. • The function of the red and green LEDs depends on how they are connected. • Combine this wiring diagram with the diagram on page 7 if connection to an alarm control panel is required. • Connect output #3 to relay output #1 disable as shown on page 6 if inhibit control is required. • To use the mantrap feature: o Use either the keypad from outside or the egress button from inside the protected premises to open one of the two doors. o While the first door is opened, the first keypad sends a signal to the second keypad to prevent the second keypad from being used to open the second door. o After the first door is closed, both keypads are ready to use. Page 10 OR O/P 1 DISABLE3 3 To (--) GND -- 12VDC power supply N.C. N.O. AUX LED 2 GREEN LED (+) N.C. + (+) (--) Door Sens 12~24V AC/DC (for DC Diode use only) 1N4004 Cathode Egress button (inside the N.O. protected premises) (+) (--) Door Sens Door 2 sensor Egress button (open door 2 from inside) 14 12~24V AC/DC OR (for DC use only) 13 O/P 1 Disable N.O. N.C. N.O. Diode 1N4004 Cathode 11 12 REMARKS: Output relay #1 N.O. output for fail-secure lock. N.C. output for fail-safe lock. LEDs: Each LED requires a 1.5K-Ohm series resistor for 24V operation. (+) -- 10 Mantrap control To (--) GND -- 12VDC power supply DOOR 2 + 9 + 1 Electric Lock 8 To O/P 1 N.O. + Egress button (open door 1 from inside). Additional egress buttons can be connected in parallel as needed. OUTPUT 1 EG N.C. C. N.O. IN 7 Mantrap control GREEN LED (--) Door 1 sensor (for DC use only) Diode 1N4004 Cathode 6 GREEN LED (+) OR -- 5 (+) N.C. N.C. N.O. + 4 OUTPUT 1 EG N.C. C. N.O. IN (+) Electric Lock 3 (+) (--) Door 12~24V AC/DC Sens To O/P 1 N.O. OUTPUT 1 EG N.C. C. N.O. IN SECO-LARM U.S.A., Inc. N.C. } } } } system Relay output #2 Alarm arm/disarm control -Consult alarm system manual for how LEDs: to connect for N.C. or N.O. operation For alarm status indication. Each Red LED LED requires a 1.5K-Ohm series resistor for 24V Green LED operation. } Tamper -To a 24-hour N.C. zone Note: PLEASE ALSO REFER TO THE NOTES ON PAGE 6 FOR MORE GENERAL INFORMATION. • The electromagnetic or electric door lock operation is the same as page 6, except the LED outputs have changed. • The function of the red and green LEDs depends on how they are connected to the alarm control panel. • Relay output #2 controls the arm/disarm of the alarm control panel. Consult the alarm control panel manual for more information. • Connect the duress output to a 24-hour N.O. zone and the tamper output to a 24-hour N.C. zone on the alarm control panel. • The connection of relay output #1 disable to output #3 as shown above is optional. When so wired, output #3 is the inhibit control. To use, program output #3 for shunt on/off operation. When output #3 is ON, relay output #1 will not work. For example, this prevents users from entering the protected premises during the evening or weekend. See programming option 61. In this case, the center auxiliary LED changes from flashing green to steady red to show that relay output #1 is disabled by the activation of output #3. • The keypad's yellow/green wire connects to the ground (-) wire of the alarm control panel to enable the two to work together. Page 7 Page 8 Page 9 Access Code 54321 0 1 2 3 4 Access Code 54321 5 6 7 8 9 Programmed For: _________________________________ 5 6 7 8 9 Programmed For: _________________________________ USER ID User Name 00 SAMPLE - John Doe 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 Note: copy this sheet to use for your installations. Output #3: Output: Shunt / Momentary (____secs.) 0 1 2 3 4 Relay Output #2: Output: Shunt / Momentary (____secs.) USER ID User Name 00 SAMPLE - John Doe 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Relay Output #1:Output: Shunt / Momentary (____secs.) Programmed For__________________________________ EK-1121SQxx - User Control Chart
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Modify, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Create Date : 2008:07:16 16:44:28-07:00 Subject : MT_983A100 Author : Phil Modify Date : 2008:07:16 16:44:30-06:00 XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Creator : Phil Description : MT_983A100 Title : MT_983A100 Creator Tool : Adobe PageMaker 7.0 Producer : Acrobat Distiller 8.1.0 (Windows) Keywords : Document ID : uuid:e492d83a-11fa-4406-9055-af6a9993b2a0 Instance ID : uuid:4a734941-fe12-4570-9954-97262ce9bd39 Page Count : 8EXIF Metadata provided by EXIF.tools