Secure Care 678TESTER System Tester User Manual A07390680

Secure Care Products Inc System Tester A07390680

User Manual

Download: Secure Care 678TESTER System Tester User Manual A07390680
Mirror Download [FCC.gov]Secure Care 678TESTER System Tester User Manual A07390680
Document ID2197353
Application IDu4dw0fKEPPbFyOj1uR/pMw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.47kB (193419 bits)
Date Submitted2014-02-21 00:00:00
Date Available2014-02-21 00:00:00
Creation Date2014-02-13 08:20:45
Producing SoftwareAcrobat Distiller 10.1.8 (Windows)
Document Lastmod2014-02-13 08:20:45
Document TitleMicrosoft Word - A07390680.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: jdrummond

User Guide
Please contact your
Distributor /
Installer for service …
Tel.: ___________________________
Model 6.78
STAT® Tester
39 Chenell Drive
Concord, NH USA 03301-8501
Phone: (800) 451-7917 / (603) 223-0745
Fax: (603) 227-0200
http://www.securecare.com
© 2013 Secure Care Products®, LLC.
CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE
FOR THE LATEST UPDATED MANUALS PLEASE VISIT AND LOG INTO THE DISTRIBUTOR PORTAL AT
WWW.SECURECARE.COM
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
TABLE OF CONTENTS
SECTION 1
IMPORTANT NOTICES
PLEASE READ THIS MANUAL BEFORE BEGINNING THE INSTALLATION OF A SECURE CARE SYSTEM
SECTION 2
SPECIFICATIONS
SECTION 3
STANDARD FEATURES
SECTION 4 TESTING INSTRUCTIONS
SECTION 5
SECTION 6
CHANGING THE SECURITY CODE
GENERAL PRODUCT WARRANTY STATEMENT
11
12
1. Notices
12
2. Limited Warranty
14
3. Limitations of Liability
15
4. Governing Law and Arbitration
15
5. Severability
16
6. Waiver
16
SECTION 7
COMPLIANCE INFORMATION
17
SECTION 8
6.78 SYSTEM TEST LOG
19
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
SECTION 1
IMPORTANT NOTICES
PLEASE READ THIS MANUAL BEFORE BEGINNING THE INSTALLATION
OF A SECURE CARE SYSTEM
This installation manual is provided for reference by purchasers and installers of Secure Care Products, LLC
(“Secure Care’s”) systems. This manual is not intended as a catalog of warnings for the protection of anyone or as a
substitute for obtaining professional training or assistance in the design of a facility’s security procedures and systems, or in
the installation, set-up, testing, support, operation, maintenance, repair or use of Secure Care’s systems. Nothing in this
manual modifies the terms of Secure Care’s General Product Warranty Statement or of any written agreement signed by
Secure Care or creates further warranties or extends benefits of any sort to anyone beyond those already expressly
established in Secure Care’s General Product Warranty Statement and in any written contract signed by Secure Care.
1.
Secure Care is Not Responsible for the Locks
ALL LOCKS USED WITH SECURE CARE’S SYSTEM ARE DESIGNED, MANUFACTURED, LABELED
AND DELIVERED SOLELY BY AN INDEPENDENT VENDOR OVER WHOM SECURE CARE HAS NO
CONTROL AND FOR WHOSE ACTIONS OR FAILURES TO ACT SECURE CARE DISCLAIMS ALL
RESPONSIBILITY. REGARDLESS OF WHETHER THE LOCKS CARRY SECURE CARE’S LOGO OR
NAME OR ANY OTHER TRADEMARK, SERVICE MARK OR TRADE NAME USED OR CLAIMED BY
SECURE CARE, SECURE CARE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, WITH
RESPECT TO THE LOCKS AND/OR THEIR USE WITH OR OPERATION IN THE SECURE CARE SYSTEM,
INCLUDING, WITHOUT LIMITATION, ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS
FOR A PARTICULAR PURPOSE, TITLE AND/OR NON-INFRINGEMENT. SECURE CARE ALSO
DISCLAIMS ALL OBLIGATIONS WITH RESPECT TO THE LOCKS AND/OR THEIR USE WITH OR
OPERATION IN THE SECURE CARE SYSTEM THAT MIGHT OTHERWISE ARISE OR BE IMPLIED FROM
THE FACT THAT SUCH LOCKS CARRY SECURE CARE’S LOGO OR NAME OR ANY OTHER
TRADEMARK, SERVICE MARK OR TRADE NAME USED OR CLAIMED BY SECURE CARE OR FROM
THE DELIVERY OR INSTALLATION OF THE LOCKS WITH SECURE CARE SOFTWARE, PARTS AND/OR
PRODUCTS OR FROM A COURSE OF DEALING OR USAGE IN TRADE. ALL RESPONSIBILITY FOR
DESIGNING, MANUFACTURING, LABELING AND WARNING OF HIDDEN DEFECTS OR DANGERS IN
THE LOCKS AND/OR THEIR USE WITH AND OPERATION IN THE SECURE CARE SYSTEM RESTS
EXCLUSIVELY WITH THE INDEPENDENT VENDOR, AND ANY CLAIMS, COSTS, DAMAGES OR
LIABILITIES ARISING FROM THE LOCKS AND/OR THEIR USE WITH OR OPERATION IN THE SECURE
CARE SYSTEM SHALL BE MADE SOLELY AGAINST THE INDEPENDENT VENDOR.
2.
Secure Care Is Not Responsible for The Computer Hardware.
IF YOU PURCHASE COMPUTER HARDWARE THROUGH SECURE CARE AND REQUEST THAT SECURE
CARE SOFTWARE BE INSTALLED AND TESTED ON THAT HARDWARE AT THE FACTORY, SECURE
CARE WARRANTS ONLY THAT THE HARDWARE AND THE SOFTWARE PACKAGES WERE
INSTALLED, SET-UP AND TESTED PRIOR TO SHIPMENT IN ACCORDANCE WITH ALL SECURE CARE
PRODUCT MANUALS AND THAT, AT THE TIME THE HARDWARE AND THE SOFTWARE PACKAGES
WERE FINALLY INSPECTED AT THE FACTORY, THEY WERE PERFORMING (SUBJECT TO SECURE
CARE’S SPECIFIED TOLERANCES) IN ACCORDANCE WITH SECURE CARE’S SPECIFICATIONS.
SECURE CARE WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN OR PROBLEMS CAUSED BY THE
HARDWARE, ALL CLAIMS FOR WHICH MUST BE MADE TO THE HARDWARE MANUFACTURER
AND/OR VENDOR. SECURE CARE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, WITH
RESPECT TO THE HARDWARE AND/OR ITS USE WITH OR OPERATION IN THE SECURE CARE
SYSTEM, INCLUDING, WITHOUT LIMITATION, ALL IMPLIED WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, TITLE AND/OR NON-INFRINGEMENT. SECURE CARE ALSO
DISCLAIMS ALL OBLIGATIONS WITH RESPECT TO THE HARDWARE AND/OR ITS USE WITH OR
OPERATION IN THE SECURE CARE SYSTEM THAT MIGHT OTHERWISE ARISE OR BE IMPLIED FROM
THE FACT THAT SUCH HARDWARE CARRIES SECURE CARE’S LOGO OR NAME OR ANY OTHER
TRADEMARK, SERVICE MARK OR TRADE NAME USED OR CLAIMED BY SECURE CARE OR FROM
THE DELIVERY OR INSTALLATION OF THE HARDWARE WITH SECURE CARE SOFTWARE, PARTS
AND/OR PRODUCTS OR FROM A COURSE OF DEALING OR USAGE IN TRADE. ALL RESPONSIBILITY
FOR DESIGNING, MANUFACTURING, LABELING AND WARNING OF HIDDEN DEFECTS OR DANGERS
IN THE HARDWARE AND/OR ITS USE WITH AND OPERATION IN THE SECURE CARE SYSTEM RESTS
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
EXCLUSIVELY WITH THE HARDWARE MANUFACTURER AND/OR VENDOR, AND ANY CLAIMS,
COSTS, DAMAGES OR LIABILITIES ARISING FROM THE HARDWARE AND/OR ITS USE WITH OR
OPERATION IN THE SECURE CARE SYSTEM SHALL BE MADE SOLELY AGAINST THE HARDWARE
MANUFACTURER AND/OR VENDOR.
3.
Several Factors Outside the Secure Care System Can Affect its Performance
Secure Care’s software, parts and products are designed for operation in a wireless system. However, the range,
performance, and predictability of any wireless system, including Secure Care’s, is dependent on several factors,
including, but not limited to, the following: building structure; environmental extremes (e.g., temperature, earth
tremors, air pollution, etc.); the proximity of other wireless devices; the presence of variable speed products; sources
of Radio Frequency Interference (RFI); physical orientation and positioning of the equipment; and sources of Electro
Static Discharge (ESD). Secure Care is not responsible for the effect of these types of factors on operation of its
software, parts and products and disclaims all responsibility for any claim relative thereto.
4.
The Secure Care System Must be Properly Installed
Secure Care's system must be installed, set-up, tested, supported, operated, maintained, repaired and used only in
accordance with all manuals and instructions (including the user, installation, technical and other manuals) issued by
Secure Care (the "Product Manuals"). It is your responsibility to assure that any person who might be installing,
setting-up, testing, supporting, maintaining or repairing the Secure Care system knows the contents of and has access
to the Product Manuals and has successfully completed Secure Care technical training. It is also your responsibility
to assure that any person who might be operating or using this Product knows the contents of and has access to the
Product Manuals and has successfully completed Secure Care in-service training. Secure Care can not be
responsible for performance problems caused by a failure to follow prescribed and appropriate procedures for
installation, set-up, testing, support, operation, maintenance, repair and use.
All adjustable features on new and repaired Secure Care software, parts and products are shipped with “factory
default” settings. These “factory default” settings may not comply with building and life safety codes or other
applicable laws and regulations in the location where they are installed or operated. Secure Care strongly
recommends, therefore, that the settings on all Secure Care software, parts and products be checked and, if
necessary, reset to comply with local building and life safety codes and other applicable laws and regulations at the
time of any installation, set-up, testing, support, maintenance or repair.
5.
Performance of the Secure Care System Software Depends on Proper Maintenance
Secure Care’s system is driven by software. However, the performance and reliability of any software-driven system
depends on adequately maintaining the recommended minimum configuration of computing platform, operating
systems and applications programs and on regularly performing industry-standard and application-specific backup
processes. If recommended minimum configurations of computing platform, operating systems, and applications
programs are not adequately maintained, or if appropriate backups are not regularly performed, the software may not
drive the system as intended. Secure Care is not responsible for operational problems caused by a failure to perform
these maintenance and backup procedures and disclaims all responsibility for any claim relative thereto.
6.
Only a Qualified Service Technician Should Work on a Secure Care System
Secure Care does not authorize, and strongly recommends against, any installation or field replacement of software,
parts or products by untrained contractors or facility staff. Such work can be hazardous, can render the system
ineffective and will void any Secure Care warranty or liability that might otherwise relate to the system.
Before any software, parts or products which have been designed and manufactured by Secure Care can be safely
installed, set-up, tested, supported, maintained or repaired, technical training in accordance with standards
established by Secure Care is required. Regardless of how Secure Care’s software, parts or products are obtained,
they should not be installed, set-up, tested, supported, maintained or repaired by any person who has not
satisfactorily completed that technical training (a “qualified service technician”.) When Secure Care’s software,
parts or products are sold separately from installation services, it is assumed that only a qualified service technician
will conduct any installation, set-up, testing, support, maintenance or repair involving that software, part or products.
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
7.
Any Work Must Comply with Electrical and Life Safety Codes
It is important that any installation, set-up, testing, support, operation, maintenance, repair or use involving the
system comply with all local and national electrical and life safety codes. If you have any questions about
compliance with those codes, please contact your local authorities.
8.
Immediately Have Replacements or Repairs Checked On-Site by a Qualified Service Technician
Secure Care receives and responds to telephone and dial-in inquires (the “Help Line”) about its software, parts and
products for the purpose of discussing users’ experiences with Secure Care’s system, helping users better understand
how their systems work, and providing ideas about what may be causing difficulties. However, Secure Care cannot
accurately diagnose the cause of any problems or give complete instructions on how to fix problems over the
telephone or Internet. The only way to assure that software, parts or products are installed, set-up, tested, supported,
maintained or repaired correctly or that a Secure Care system is functioning properly is to have it examined on site
by a qualified service technician. In addition, Secure Care software, parts and products cannot be operated or used
correctly by anyone who has not successfully completed Secure Care in-service training. Secure Care’s Help Line is
not a substitute for on-site diagnosis and servicing by a qualified service technician or for successful completion of
Secure Care in-service training. Secure Care strongly recommends that any installation, set-up, testing, support,
maintenance or repair of a system that is performed by a person who has not satisfactorily completed technical
training in accordance with standards established by Secure Care be immediately checked on-site by a qualified
service technician.
WARNING: EVEN SLIGHT MODIFICATIONS TO THE SYSTEM OR CHANGES IN THE OPERATING
ENVIRONMENT MAY CAUSE SECURE CARE’S SYSTEM TO MALFUNCTION. THE ONLY WAY TO
ASSURE THAT SECURE CARE’S SYSTEM HAS BEEN INSTALLED, SET-UP, TESTED, SUPPORTED,
MAINTAINED AND REPAIRED CORRECTLY IS TO HAVE A QUALIFIED SERVICE TECHNICIAN DO
THE WORK.
9.
The Secure Care System is not a Substitute for Careful Identification and Monitoring by
Professional Staff
Secure Care’s software, parts and products have been designed to augment a facility’s reasonable procedures for
protecting residents, patients, and infants. However, no system or combination of procedures and equipment can
eliminate all risk or assure complete security. Secure Care’s system is not intended as a substitute for the careful
identification and monitoring of residents, patients, and infants by a facility’s professional staff.
Revised 01/22/14
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
SECTION 2
SPECIFICATIONS
Dimensions:
3.20" (W) x 8.25" (L) x 1.78" (D)
Input Voltage:
9VDC alkaline battery
Indicators:
Eight character LCD display,
Green and yellow LED’s
Programming Range:
Tester must be placed on the face of the transmitter.
Auto-off feature:
Automatic shut-off after two minutes of inactivity.
All Specifications are subject to change without notice.
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
SECTION 3
STANDARD FEATURES

Transmitter ID Code Tester-Default mode of Operation

Exit Tester

Cutband Tester

Transmitter “Sleep Mode” Activator

Keypad Programmable

Auto-Off feature

Programmable Security Code

9 Volt Battery Powered
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
SECTION 4 TESTING INSTRUCTIONS
NOTE: The Tester will automatically shut off after two minutes of inactivity.
NOTE: Transmitters that are not in use should be stored in a metal container.
How to Check a Transmitter ID Code
1.
Press
ON
on the Tester. A steady green power (“PWR”) light should display;
NOTE: A blinking green power (PWR) light indicates a
low battery. Replace the Tester battery before proceeding.
2.
After the strap has been on the transmitter for at least one minute, position the 6.78MHz transmitter so that it is
touching the display end of the Tester. (See Fig. 1 below for proper positioning of the transmitter
relative to the Tester unit.)
Figure 1. Transmitter-to-Tester Orientation
3.
The yellow (“Signal”) LED should begin flashing. The ID code of the transmitter should be received by the
unit and displayed on the LCD display. The display will toggle between the transmitter’s four digit ID and
"TX OK".
If only the transmitter ID number is displayed, then the tag is in cutband mode. If the proper ID code has
been received and displayed by the Tester, then the transmitter is assumed to be operating properly. “TX
OK” not appearing on the display implies you have a problem strap or strap connection. In order to get the
Tester to show “TX OK” you will need to replace the strap and test again.
If a transmitter ID was received incorrectly then the tester will display either "CHK XMTR", or "_ _ _ _".
(Ensure the transmitter is positioned correctly relative to the top of the Tester. (See Fig. 1))
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
SECTION 4 TESTING INSTRUCTIONS
How to Test the Exit System
1. Press
ON
on the Tester. A steady green power (“PWR”) light should display;
NOTE: A blinking green power (PWR) light indicates a
low battery. Replace the Tester battery before proceeding.
2. Enter the currently programmed security code (*23456 default) on the Tester keypad
3. Press and hold
DOOR
4. Approach the exit under test. When in range of the door receiver, the red lock LED (top right LED) on the Exit
Panel turns on, the door should lock if so equipped, and the exit system should arm.
5. Release the Door button and the exit system should un-arm.
6. With the door in the open position, press and hold the Door button, the Exit Panel should enter an alarm state. The
top center red LED (bell symbol) on the panel will flash and an on/off tone will be emitted.
7. Close the door and reset the Exit Panel.
NOTE: The Tester is not to be used to test range or to adjust the range of
the door exit system. The tester is only used to test the function of the exit
system.
How to Test the Cutband Zone Receivers
Be sure to alert all Nursing and Security staff prior to testing the Cutband Zone Receivers. When the Cutband Zone
Receiver is tested, all exit systems will enter an armed state, locking all doors equipped with electromagnetic locks.
1. Press
ON
on the Tester. A steady green power (“PWR”) light should display;
NOTE: A blinking green power (PWR) light indicates a low battery. Replace
the Tester battery before proceeding.
2. Go to the cutband zone under test.
3.
Enter the currently programmed security code (*23456 default) on the Tester keypad
4. Press
CUT
BAND
5. Within a few seconds, all exit systems should enter the armed state, locking all doors equipped with
electromagnetic locks.
6. The Nurse Station should enter an alarm state with an audible alarm and the “cutband in alarm” will flash and turn
red on the display.
7. Document which cutband zones have received the cutband test.
8. Go to other areas of the protected area and repeat the above test. Continue testing in various areas until all cutband
zones have been tested and displayed on the Nurse Station.
NOTE: The above tests are designed to simulate the actual operating characteristics of the
system. Testing should be done on a weekly basis using a live transmitter to verify the
actual operation of the exit systems and cutband zones. Forms are included at the end of
this Section to document test results.
NOTE: The Tester is not to be used to test range or to adjust the range of
the cutbands. The tester is only used to test the function of the cutbands.
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
SECTION 4 TESTING INSTRUCTIONS
Placing a Transmitter into the "Sleep" Mode
Prior to removing the Cutband Transmitter from the monitored resident or infant, the Transmitter must be placed into the
"Sleep" mode using the Tester. If the Transmitter is not placed into the "Sleep" mode prior to cutting the Transmitter strap,
then the system will detect a cut strap and produce a cutband alarm. The alarm will lock all door exits and create an alarm
condition at the Nurse Station.
The following procedure must be followed:
1. Press
ON
on the Tester. A steady green power (“PWR”) light should display;
NOTE: A blinking green power (PWR) light indicates a
low battery. Replace the Tester battery before proceeding.
2. Enter the security code *23456 on the Tester keypad;
3. Ensure that the "ENABLE" message is displayed on the Tester; this should occur within two seconds. The Tester
will then display a blinking black square;
4. Orient the Transmitter to the front of ankle/shin of the infant;
5. Bring the top of the Tester up to the Transmitter;
6. Ensure that there is a blinking yellow “Signal” light on the Tester;
7. Also ensure that the Tester displays a four-digit ID code and “TX OK”. (The displayed ID code should be the
same as the engraved ID code on the Transmitter itself.);
8. Enter the sleep code # with the Tester positioned with display end touching the transmitter;
9. Hold the tester against the transmitter until a "SLEEP OK" message is displayed and you hear 5 beeps.
This may take up to 15 seconds.
10. If the "SLEEP OK" message is displayed, then cut the band. You will have 30 seconds to do so. Do not attempt to
re-enter another sleep code within the 30 second time period;
11. If the Tester displays a “SLP FAIL” (sleep fail) message, then this procedure should be repeated beginning with
Step 4 above. Verify that the Tester and Transmitter are properly oriented before re-starting the procedure. You
do not have to re-enter your security code to proceed;
NOTE: In order for the Tester unit to transmit a Sleep command to the Transmitter, the
Tester must initially display the "ENABLE" message and, when the Tester is placed on
the Transmitter, display an ID code and produce a blinking “Signal” light.
To Activate a Transmitter that is Already in “Sleep” Mode
Obtain a new cradle/strap assembly. Slide the cradle/strap onto the back of the Transmitter. This will reactivate the
Transmitter and start transmissions after 30 seconds.
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
10
SECTION 5
CHANGING THE SECURITY CODE
To Change the Tester’s Security Code
1. Press
ON
on the Transmitter Tester; A steady green power (“PWR”) light should display;
NOTE: A blinking green power (PWR) light indicates a low battery. Replace the Tester
battery before proceeding.
2.
3.
4.
5.
Press *23456 (security code);
Immediately press 5. The Tester will display "NEW CODE";
Enter the new five digit security code. The Tester will display "CODE OK";
This new code is stored in non-volatile memory and will be retained permanently, or, until the code is changed
again. To make future code changes simply repeat the above procedure – again, using *and the current code,
then 5, and enter the next code to be used.
If you have any questions please call your Distributor/Installer first, then if necessary call Secure Care Products, LLC Service
Department at 1-800-451-7917 or email Orders_39@securecare.com.
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
11
SECTION 6 GENERAL PRODUCT WARRANTY
STATEMENT
BY PERMITTING INSTALLATION OR BY MAKING USE OF ANY PRODUCT OR SERVICE DESIGNED OR
MANUFACTURED BY SECURE CARE PRODUCTS, LLC. (“SECURE CARE”) (INCLUDING SUPPORT SERVICES,
MAINTAINED SOFTWARE AND MAJOR RELEASES, WHETHER OR NOT IT IS COVERED BY ANY SOFTWARE
MAINTENANCE OR LICENSE AGREEMENT) (“THIS PRODUCT”), YOU ACKNOWLEDGE THAT YOU HAVE
READ ALL THE TERMS AND CONDITIONS OF THIS GENERAL PRODUCT WARRANTY STATEMENT, THAT
YOU UNDERSTAND THEM, AND THAT YOU AGREE TO BE BOUND BY THEM. YOU UNDERSTAND THAT, IF
YOU PURCHASED THIS PRODUCT FROM ANY AUTHORIZED DISTRIBUTOR OF SECURE CARE, THAT
DISTRIBUTOR IS NOT SECURE CARE’S AGENT AND IS NOT AUTHORIZED TO MAKE ANY
REPRESENTATIONS OR WARRANTIES OR TO AGREE TO ANY TERMS OR CONDITIONS WHICH ARE
DIFFERENT FROM ANYTHING EXPRESSLY SET FORTH IN THIS GENERAL PRODUCT WARRANTY
STATEMENT.
If you do not agree to the terms and conditions of this General Product Warranty Statement, do not permit the installation or
make use of this Product and promptly return this Product to the place where you obtained it for a full refund. If you have
any difficulty obtaining a refund, please contact Secure Care at the telephone number provided in Section 2.B below.
1. Notices
A. ALL LOCKS USED WITH THE SECURE CARE SYSTEM ARE DESIGNED, MANUFACTURED, LABELED
AND DELIVERED SOLELY BY AN INDEPENDENT VENDOR OVER WHOM SECURE CARE HAS NO CONTROL
AND FOR WHOSE ACTIONS OR FAILURES TO ACT SECURE CARE DISCLAIMS ALL RESPONSIBILITY.
REGARDLESS OF WHETHER THE LOCKS CARRY SECURE CARE’S LOGO OR NAME OR ANY OTHER
TRADEMARK, SERVICE MARK OR TRADE NAME USED OR CLAIMED BY SECURE CARE, SECURE CARE
DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, WITH RESPECT TO THE LOCKS AND/OR THEIR USE
WITH OR OPERATION IN THE SECURE CARE SYSTEM, INCLUDING, WITHOUT LIMITATION, ALL IMPLIED
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE AND/OR NONINFRINGEMENT. SECURE CARE ALSO DISCLAIMS ALL OBLIGATIONS WITH RESPECT TO THE LOCKS
AND/OR THEIR USE WITH OR OPERATION IN THE SECURE CARE SYSTEM THAT MIGHT OTHERWISE ARISE
OR BE IMPLIED FROM THE FACT THAT SUCH LOCKS CARRY SECURE CARE’S LOGO OR NAME OR ANY
OTHER TRADEMARK, SERVICE MARK OR TRADE NAME USED OR CLAIMED BY SECURE CARE OR FROM
THE DELIVERY OR INSTALLATION OF THE LOCKS WITH SECURE CARE SOFTWARE, PARTS AND/OR
PRODUCTS OR FROM A COURSE OF DEALING OR USAGE IN TRADE. ALL RESPONSIBILITY FOR
DESIGNING, MANUFACTURING, LABELING AND WARNING OF HIDDEN DEFECTS OR DANGERS IN THE
LOCKS AND/OR THEIR USE WITH AND OPERATION IN THE SECURE CARE SYSTEM RESTS EXCLUSIVELY
WITH THE INDEPENDENT VENDOR, AND ANY CLAIMS, COSTS, DAMAGES OR LIABILITIES ARISING FROM
THE LOCKS AND/OR THEIR USE WITH OR OPERATION IN THE SECURE CARE SYSTEM SHALL BE MADE
SOLELY AGAINST THE INDEPENDENT VENDOR.
B. IF YOU PURCHASE COMPUTER HARDWARE THROUGH SECURE CARE AND REQUEST THAT SECURE
CARE SOFTWARE BE INSTALLED AND TESTED ON THAT HARDWARE AT THE FACTORY, SECURE CARE
WARRANTS ONLY THAT THE HARDWARE AND THE SOFTWARE PACKAGES WERE INSTALLED, SET-UP
AND TESTED PRIOR TO SHIPMENT IN ACCORDANCE WITH ALL SECURE CARE PRODUCT MANUALS AND
THAT, AT THE TIME THE HARDWARE AND THE SOFTWARE PACKAGES WERE FINALLY INSPECTED AT
THE FACTORY, THEY WERE PERFORMING (SUBJECT TO SECURE CARE’S SPECIFIED TOLERANCES) IN
ACCORDANCE WITH SECURE CARE’S SPECIFICATIONS. SECURE CARE WILL NOT BE RESPONSIBLE FOR
ANY DEFECTS IN OR PROBLEMS CAUSED BY THE HARDWARE, ALL CLAIMS FOR WHICH MUST BE MADE
TO THE HARDWARE MANUFACTURER AND/OR VENDOR. SECURE CARE DISCLAIMS ALL WARRANTIES,
EXPRESS OR IMPLIED, WITH RESPECT TO THE HARDWARE AND/OR ITS USE WITH OR OPERATION IN THE
SECURE CARE SYSTEM, INCLUDING, WITHOUT LIMITATION, ALL IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE AND/OR NON-INFRINGEMENT.
SECURE CARE ALSO DISCLAIMS ALL OBLIGATIONS WITH RESPECT TO THE HARDWARE AND/OR ITS USE
WITH OR OPERATION IN THE SECURE CARE SYSTEM THAT MIGHT OTHERWISE ARISE OR BE IMPLIED
FROM THE FACT THAT SUCH HARDWARE CARRIES SECURE CARE’S LOGO OR NAME OR ANY OTHER
12
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
TRADEMARK, SERVICE MARK OR TRADE NAME USED OR CLAIMED BY SECURE CARE OR FROM THE
DELIVERY OR INSTALLATION OF THE HARDWARE WITH SECURE CARE SOFTWARE, PARTS AND/OR
PRODUCTS OR FROM A COURSE OF DEALING OR USAGE IN TRADE. ALL RESPONSIBILITY FOR
DESIGNING, MANUFACTURING, LABELING AND WARNING OF HIDDEN DEFECTS OR DANGERS IN THE
HARDWARE AND/OR ITS USE WITH AND OPERATION IN THE SECURE CARE SYSTEM RESTS EXCLUSIVELY
WITH THE HARDWARE MANUFACTURER AND/OR VENDOR, AND ANY CLAIMS, COSTS, DAMAGES OR
LIABILITIES ARISING FROM THE HARDWARE AND/OR ITS USE WITH OR OPERATION IN THE SECURE CARE
SYSTEM SHALL BE MADE SOLELY AGAINST THE HARDWARE MANUFACTURER AND/OR VENDOR.
C. Secure Care’s software, parts and products are designed for operation in a wireless system. However, the range,
performance, and predictability of any wireless system, including Secure Care’s, is dependent on several factors, including,
but not limited to, the following: building structure; environmental extremes (e.g., temperature, earth tremors, air pollution,
etc.); the proximity of other wireless devices; the presence of variable speed products; sources of Radio Frequency
Interference (RFI); physical orientation and positioning of the equipment; and sources of Electro Static Discharge (“ESD”).
Secure Care cannot be responsible for the effect of these types of factors on operation of its software, parts and products.
D. This Product must be installed, set-up, tested, supported, operated, maintained, repaired and used only in accordance
with all manuals and instructions (including the user, installation, technical and other manuals) issued by Secure Care (the
“Product Manuals”). It is your responsibility to assure that any person who might be installing, setting-up, testing,
supporting, maintaining or repairing this Product knows the contents of and has access to the Product Manuals and has
successfully completed Secure Care technical training. It is also your responsibility to assure that any person who might be
operating or using this Product knows the contents of and has access to the Product Manuals and has successfully completed
Secure Care in-service training. If you do not have the Product Manuals or if you have any questions regarding this Product
and/or its installation, set-up, testing, support, operation, maintenance, repair or use, please call Secure Care at the telephone
number provided in section 2.B below. Secure Care cannot be responsible for performance problems caused by a failure to
follow published and appropriate procedures for installation, set-up, testing, support, operation, maintenance, repair and use.
All adjustable features on new and repaired Secure Care software, parts and products are shipped with “factory default”
settings. These “factory default” settings may not comply with building and life safety codes or other applicable laws and
regulations in the location where they are installed or operated. Secure Care strongly recommends, therefore, that the settings
on all Secure Care software, parts and products be checked and, if necessary, reset to comply with local building and life
safety codes and other applicable laws and regulations at the time of any installation, set-up, testing, support, maintenance or
repair.
E. Secure Care’s system is driven by software. However, the performance and reliability of any software-driven system
depends on adequately maintaining the recommended minimum configuration of computing platform, operating systems and
applications programs and on regularly performing industry-standard and application-specific backup processes. If
recommended minimum configurations of computing platform, operating systems, and applications programs are not
adequately maintained, or if appropriate backups are not regularly performed, the software may not drive the system as
intended. Secure Care cannot be responsible for operational problems caused by a failure to perform these maintenance and
backup procedures.
F. Secure Care does not authorize, and strongly recommends against, any installation or field replacement of software,
parts or products by untrained contractors or facility staff. Such work can be hazardous, can render the system ineffective
and will void any Secure Care warranty or liability that might otherwise relate to the system.
Before any software, parts or products, which have been designed and manufactured by Secure Care can be safely installed,
set-up, tested, supported, maintained or repaired, technical training in accordance with standards established by Secure Care
is required. Regardless of how Secure Care’s software, parts or products are obtained, they should not be installed, set-up,
tested, supported, maintained or repaired by any person who has not satisfactorily completed that technical training (a
“qualified service technician”.) When Secure Care’s software, parts or products are sold separately from installation services,
it is assumed that only a qualified service technician will conduct any installation, set-up, testing, support, maintenance or
repair involving that software, part or products.
G. It is important that any installation, set-up, testing, support, operation, maintenance, repair or use involving the system
comply with all local and national electrical and life safety codes. If you have any questions about compliance with those
codes, please contact your local authorities.
13
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
H. Secure Care receives and responds to telephone and dial-in inquires (the “Help Line”) about its software, parts and
products for the purpose of discussing users’ experiences with Secure Care’s system, helping users better understand how
their systems work, and providing ideas about what may be causing difficulties. However, Secure Care cannot accurately
diagnose the cause of any problems or give complete instructions on how to fix problems over the telephone or Internet. The
only way to assure that software, parts or products are installed, set-up, tested, supported, maintained or repaired correctly or
that a Secure Care system is functioning properly is to have it examined on site by a qualified service technician. In addition,
Secure Care software, parts and products cannot be operated or used correctly by anyone who has not successfully completed
Secure Care in-service training. Secure Care’s Help Line is not a substitute for on-site diagnosis and servicing by a qualified
service technician or for successful completion of Secure Care in-service training. Secure Care strongly recommends that
any installation, set-up, testing, support, replacement, maintenance or repair of a system that is performed by a person who
has not satisfactorily completed technical training in accordance with standards established by Secure Care be immediately
checked on-site by a person who has completed that technical training.
WARNING:
EVEN SLIGHT MODIFICATIONS TO THE SYSTEM OR CHANGES IN THE OPERATING
ENVIRONMENT MAY CAUSE SECURE CARE’S SYSTEM TO MALFUNCTION. THE ONLY WAY TO ASSURE
THAT SECURE CARE’S SYSTEM HAS BEEN INSTALLED, SET-UP, TESTED, SUPPORTED, MAINTAINED, AND
REPAIRED CORRECTLY IS TO HAVE A QUALIFIED SERVICE TECHNICIAN DO THE WORK.
I. Secure Care’s software, parts and products have been designed to augment a facility’s reasonable procedures for
protecting residents, patients, and infants. However, no system or combination of procedures and equipment can eliminate
all risk or assure complete security. Secure Care’s system is not intended as a substitute for the careful identification and
monitoring of residents, patients, and infants by a facility’s professional staff.
2. Limited Warranty
A. Subject to the limitations set forth in this general product warranty statement (as amended from time to time by
Secure Care in its absolute discretion), and unless a different period is specified in writing by Secure Care for a particular
product or service, Secure Care warrants that this product (subject to Secure Care's specified tolerances and excluding any
expendable items), if sold by Secure Care to an authorized Secure Care distributor, shall conform to the specifications which
accompany this product for a period of one (1) year from the date of delivery of this product by Secure Care to a common
carrier, f.o.b. Secure Care’s manufacturing facility in Concord, New Hampshire or, in the case of services, from the date of
first provision of such services. This warranty does not extend to and is not for the benefit of any person other than an
authorized Secure Care distributor who purchases this product from Secure Care, any sub-distributor thereof and/or the
customer to whom this product is first provided for use, by Secure Care, an authorized Secure Care distributor or any subdistributor thereof. In the event that this product does not comply with this warranty, Secure Care will, at its option, either
repair or replace this product or refund the purchase price, provided that this product is returned as provided in section 2.b
below. Replacement of this product under warranty will not extend the original warranty period.
Secure Care will also, at its option, either repair or replace this Product after the warranty has expired, for an additional
charge, provided that this Product is returned as provided in Section 2.B below. If Secure Care repairs or replaces this
Product after the warranty has expired, the terms of the warranty set forth in this Section 2.A for a new Product will apply to
the repaired or replaced Product, with the exception that the term will run for ninety (90) days from the date of repair or
replacement.
Repair may include the replacement of parts and products with functionally equivalent, reconditioned parts or products. Any
part or product replaced by Secure Care will become the property of Secure Care upon replacement.
B. Warranty service is available by contacting Secure Care at 800-451-7917 and obtaining a Return Authorization
Number. No Product may be returned to Secure Care without first obtaining a Return Authorization Number. When this
Product is returned to Secure Care, please include the Return Authorization Number and a detailed written description of the
problem. Issuance of a Return Authorization Number by Secure Care will not constitute an admission that there is a problem
with the Product being returned, that any problem is covered by warranty or that Secure Care has any responsibility to repair,
replace, make refunds for or pay claims, costs, damages or liabilities connected with the Product being returned.
NOTE: Transmitters are not repaired, nor is the warranty extended, beyond the expiration date.
14
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
If this Product is returned to Secure Care for any reason, you will retain title (unless and until a part or product is replaced, in
which case you will obtain title to the replacement part or product at the time of replacement), the risk of loss, and the
obligation to pay all costs of shipping, storage and other charges and obligations relating to this Product.
C. Except as stated in this section 2, Secure Care disclaims all warranties, express or implied, with respect to the whole or
any part of this product, including, without limitation, all implied warranties of merchantability, fitness for a particular
purpose, title and/or non-infringement. Secure Care also disclaims all obligations that might otherwise arise or be implied
from a course of dealing or usage in trade.
3. Limitations of Liability
A. Regardless of the form of any claim or action, Secure Care’s total liability to all persons, whether singly or together,
for all occurrences combined, for claims, costs, damages or liabilities based on any cause whatsoever and arising from or in
connection with this product, or the manufacture, distribution, promotion, sale, installation, set-up, testing, support,
maintenance, operation, servicing, use or performance of this product, or from or in connection with any delay or failure in
providing this product, shall not exceed the aggregate price (without interest) paid to Secure Care for this product.
B. In no event shall Secure Care be liable to anyone for any loss of data, loss of profits or loss of use of this product or
any equipment, or for any special, incidental, consequential, exemplary, punitive, multiple, or other damages, arising from or
in connection with the manufacture, distribution, promotion, sale, installation, set-up, testing, support, maintenance,
operation, servicing, use or performance of this product or from or in connection with any delay or failure in providing or
delivering this product.
C. In no event shall Secure Care be liable to anyone for any claims, costs, damages or liabilities caused by: (i) any
distributor’s failure to perform its obligations and responsibilities under a distributor agreement with Secure Care; (ii)
improper or defective promotion, distribution, sale, installation, set-up, testing, support, maintenance or repair of this product,
including work performed, without Secure Care’s prior written consent in its absolute discretion, by a person who has not
satisfactorily completed Secure Care technical training, or in a manner not consistent with Secure Care technical training; (iii)
improper or defective operation or use of this product by a person who has not successfully completed Secure Care in-service
training, or in a manner not consistent with Secure Care in-service training; (iv) supply of this product by a distributor for use
in, or the use of this product in, any system or configuration not designed to Secure Care standards or in which a distributor
or any third party has substituted materials and/or goods not specified by Secure Care; or (v) deterioration of this product
during storage.
D. You agree to indemnify and hold Secure Care harmless from all claims, costs, damages and liabilities asserted by
anyone for any damages that are excluded and waived, or are intended to be excluded and waived, by this section 3, or which
are imposed by law on behalf of anyone but which are not expressly stated in this general product warranty statement.
E. The exclusions, waivers and limitations on claims, costs, damages and liabilities and any rights of indemnification set
forth in this Section 3 shall be enforceable to the maximum extent allowed by law and shall not be expanded or negated in
any respect by Secure Care’s operation of a “help line” to receive and respond to telephone or dial-in inquires about this
product, by any communications through that “help line” or by any actions taken by anyone following communications with
Secure Care over such “help line.”
4. Governing Law and Arbitration
A. This General Product Warranty Statement, and all questions arising out of or relating to it, shall be governed by and
construed in accordance with the laws of the State of New Hampshire, without giving effect to the conflict of laws provisions
thereof, and excluding the United Nations Convention on contracts for the international sale of goods, the 1974 convention
on the limitation period on the international sale of goods (the “1974 convention”), and the protocol amending the 1974
convention, done at Vienna April 11, 1980.
B. Any dispute, controversy or claim arising out of or relating to this general product warranty statement shall be resolved
by arbitration. Regardless of the amount in dispute, the arbitration shall be conducted by a single arbitrator selected by the
parties or, if they cannot agree, by a single arbitrator selected in accordance with the commercial arbitration rules of the
American Arbitration Association without regard to the amount in dispute. The arbitration shall be conducted in English, in
15
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
accordance with the commercial arbitration rules of the American Arbitration Association, in Concord, New Hampshire. The
decision of the arbitrator shall be binding and enforceable by any state or federal court in New Hampshire, and you hereby
consent to the personal jurisdiction of any state or federal court in New Hampshire for that purpose. The expense of the
arbitration (excluding each side’s own attorneys' fees, costs, and related expenses) shall initially be paid in equal shares by
each side, but the total of such expenses plus any award of attorneys' fees, cost and expenses shall finally be paid by the
parties as the arbitrator determines. Nothing in this section 4.b shall preclude Secure Care from seeking provisional or
equitable relief from any appropriate court to protect its rights prior to, pending or in the absence of such arbitration
proceedings.
5. Severability
The invalidity or unenforceability of any provision of this General Product Warranty Statement shall not affect the validity or
enforceability of any other provision hereof.
6. Waiver
No term or condition of this General Product Warranty Statement may be waived except in writing signed by Secure Care. A
waiver on one or more occasions of any term or condition of this General Product Warranty Statement shall not constitute or
be deemed to be a waiver of such term or condition on any other occasion. No delay or failure of Secure Care to exercise any
right or remedy under this General Product Warranty Statement will operate as a waiver thereof; no failure to enforce or
insist upon compliance with any provision of this General Product Warranty Statement on any one occasion shall be deemed
to be a waiver of Secure Care's right to do so on another occasion; and no course of dealing will constitute a waiver,
alteration, limitation or expansion of any of the parties' rights and obligations under this General Product Warranty
Statement.
Revised 01/22/14
16
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
SECTION 7 COMPLIANCE INFORMATION
FCC Compliance Statement
FCC ID: KNK678TESTER
This device complies with Part 15 of the FCC Rules
Operation is subject to the following two conditions
(1) This device may not cause harmful interference and
(2) This device must accept any interference received,
Including interference that may cause undesired operation
Information to user
Changes or modifications to the transmitter not expressly approved by Secure Care
Products, LLC may void the users authority to operate the Model 6.78 system.
17
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
18
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14
SECTION 8 6.78 System Test Log
Weekly 6.78 Exit System Test Log
DATE_____________________________
Exit Location
Doors Lock
Doors Alarm
Date
Exit Location
Pass/Fail
Comments
NOTE: Test all the exits on a weekly basis
19
Doc. No.: A07390680
Rev. B
ECO: 11030 Date: 02/XX/14

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : jdrummond
Create Date                     : 2014:02:13 08:20:45-05:00
Modify Date                     : 2014:02:13 08:20:45-05:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 10.1.8 (Windows)
Format                          : application/pdf
Title                           : Microsoft Word - A07390680.doc
Creator                         : jdrummond
Document ID                     : uuid:1f83ae30-aa73-4461-adf2-974dbf87dc2e
Instance ID                     : uuid:42ef8b1a-096e-49f5-b4f7-0c6b8d2523bd
Page Count                      : 19
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KNK678TESTER

Navigation menu