WT1 Wiegand Test Unit : Wiring and Use Instructions
FOR INSTALLATION ASSISTANCE, CALL 1-800-810-WIRE
Copyright © 2008, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Inc. is prohibited.
WTMN1 – PAGE 1
CONTENTS WT1, plastic, 6.25” x 3.5” x 2.375”
AC / DC power adapter
ElectroLynx cable
Wiring harness
As part of their promise to provide innovative, fast and
effective, and higher security solutions to their customers,
ASSA ABLOY Group companies offer ElectroLynx, a universal
quick-connect system that simplifies the electrification of
the door opening. ElectroLynx™ is a trademark of ASSA
ABLOY, Inc.
Designed for compatibility with ASSA ABLOY products and
other Wiegand output devices, the ASSA ABLOY WT1, or
Wiegand Test Unit, is a user-friendly tool that demonstrates
products features and capabilities.
The WT1 also provides field troubleshooting by verifying
proper wiring, card reader data integrity, lock functionality
including lock/unlock, door position status, and request-to-
exit (REX) status.
The WT1 connects directly to Wiegand output for testing.
Connect your product's interface board (if required) to
translate to Wiegand, then connect the WT1 to the interface
board. If your product does not need an interface board to
provide Wiegand output, you may connect it directly to the
WT1.
To connect the WT1 to the product, use the enclosed
ElectroLynx cable; if an interface board is required, connect the
WT1 to the interface board using the enclosed wiring harness.
TEST BOX
PRODUCT
DESCRIPTION
Adapter
End View
n Fail Safe /Fail Secure Selector
o Open Override
p Learn Button
q 12VDC / 24VDC Selector
r To Power Adapter
s To Lock
function of interface module
^ LEDs refer to the following product features:
DPS Door position switch
RX Request to exit
LX Latch bolt monitoring
DX Dead bolt monitoring
CX Cylinder monitoring (not currently in use)
TMPR Tamper
VISUAL
MONITORING
INDICATORS
PWR ON Indicates unit powered
IMPORTANT 1. Disconnect unit to be tested from access control
system before servicing.
2. Installer must be a trained, experienced service
person.
3. Wiring must comply with applicable local electrical
codes, ordinances and regulations.
4. Unit is grounded to Common (-) for Electrostatic
Discharge (ESD) protection. Use appropriate ESD
practices when handling the circuit board, (i.e.
standard grounding precautions). Common (-) must
be grounded to earth (EG) at the power supply.
5. Ensure that no wires are pinched or damaged during
installation.
Install equipment on door according to manufacturer’s instructions. Please refer these websites for installation
instructions at:
INSTALLATION
INSTRUCTIONS
ASSA ABLOY: www.intelligentopenings.com
HES: www.hesinnovations.com
Securitron: www.securitron.com
1 2 34
6
5
6
1 2 34
7
WT1 Wiegand Test Unit : Wiring and Use Instructions
FOR INSTALLATION ASSISTANCE, CALL 1-800-810-WIRE
Copyright © 2008, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Inc. is prohibited.
WTMN1– PAGE 2
CONNECT THE WT1 To connect the WT1, determine whether your lock provides a direct Wiegand output, or if it requires an
interface panel to convert to Wiegand.
If your lock is direct-connect, follow the diagram under the ElectroLynx Wiegand Wiring Diagram. If your
lock requires an interface panel, follow the diagram under Wiring Diagram for Interface Board to WT1.
ElectroLynx Hinge with Pin Connections
Lock Cable ElectroLynx Cable to WT1
ELECTROLYNX
WIEGAND WIRING
DIAGRAM
Use the provided
ElectroLynx cable when the
product has direct Wiegand
output.
Lock to
WT1 Connections
Notes
The System is designed to
be installation friendly with
ElectroLynx quick
connectors.
Hinge With ElectroLynx
Cable Detail
Important
ElectroLynx connectors plug
and lock together in only
one way, as shown. Do NOT
force connectors together.
Reference ElectroLynx
Catalog A7738.
Power Input AC 100 – 240V 800mA 50Hz/60Hz
Power Output The WT1 is capable of supplying a total of 900 MA output to the unit under test.
The 900 MA is the total output for both reader interface and the lock.
PIN ASSIGNMENT TABLE FOR WIRE HARNESS
The following chart shows the wiring assignments for the wire harness included with the WT1. This harness is only used when the lock's
output must first go through an interface board to translate to Wiegand.
See the connection diagram on the following page for how to wire the interface board to the WT1.
PIN # DESCRIPTION WIRE COLOR WIRE CABLE ELYNX CABLE MISCELLANEOUS COMMENTS
1 Reader Power - Black Controller TS1 8 PIN -1 Ground
2 Reader Power + Red Not Used 8 PIN -2 +12 VDC always
3 Wiegand Data 1 White Controller TS4 8 PIN -3 +5 goes to ground for data 1 bit
4 Wiegand Data 0 Green Controller TS4 8 PIN -4 +5 goes to ground for data 0 bit
5 REX Switch NC/NO (Keeper Switch on Strike) Orange Controller TS4 8 PIN -5 LED on when REX used or when Keeper closed
6 REX Switch COM (Keeper Switch on Strike) Blue Controller TS4 8 PIN -6 LED on when REX used or when Keeper closed
7 Beeper Control - Cylinder Switch Brown Not Used Not Used
8 LED Control Yellow Not Used 8 PIN -8 +5 goes to ground to turn LED Green
9 Lock Power Violet Not Used 4 PIN -1 Ground
10 Lock Relay Out Grey Not Used 4 PIN -2 Lock Power+
11 DPS Switch NC/NO Pink Controller TS4 4 PIN -3 LED on when switch closed
12 DPS Switch COM Tan Controller TS4 4 PIN -4 LED on when switch closed
13 Beeper Control Brown Controller TS4 Not Used +5 to turn Beeper on
14 LED Control Yellow Controller TS4 Not Used +5 to turn LED Green
15 Dead Bolt Switch NC/NO White/Orange AUX Board TS1 AUX-2 Not Used LED on when secure (Dead Bolt extended)
16 Latch Bolt Switch NC/NO White/Red AUX Board TS1 AUX-1 Not Used LED on when secure (Latch Bolt extended)
17 Cylinder Switch NC/NO - Spare White/Black Not Used Not Used LED on when Key in use (future)
18 Tamper Relay NC/NO White/Blue Controller TS1 Not Used LED on when Tamper true
19 Lock Power + / Controller Power Red Controller TS1 See Table 1 v.N1 controller can be 12 or 24 (switch selected)
20 Lock Relay IN Violet See Table 1 See Table 1 Use for Fail Secure Lock
Rece
p
tacle
Lockin
g
Mechanism
Plu
g
WT1 Wiegand Test Unit : Wiring and Use Instructions
FOR INSTALLATION ASSISTANCE, CALL 1-800-810-WIRE
Copyright © 2008, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Inc. is prohibited.
WTMN1 – PAGE 3
WIRING DIAGRAM FOR INTERFACE BOARD TO WT1
The following wiring diagram shows how to connect the WT1 wiring harness:
ElectroLynx
To
Interface
Board
Wie
g
and Test Box Wirin
g
Harness Connections
(
re
f
er to Wire Harness Table
)
WT1 Wiegand Test Unit : Wiring and Use Instructions
FOR INSTALLATION ASSISTANCE, CALL 1-800-810-WIRE
Copyright © 2008, ASSA ABLOY Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Inc. is prohibited.
WTMN1– PAGE 4
OPERATING
INSTRUCTIONS FOR
ALL CARDS
NOTES: Failure to
connect the WT1 to the
lock before applying
power result in false
reads.
The WT1 is capable of
remembering up to the
last 20 programmed, or
learned, cards. To clear
all cards from memory,
hold down the learn
button while applying
power.
The door device green
LED flashes.
To initialize the test box for all cards:
1. Connect all wires to the WT1 first.
2. Select Fail Safe or Fail Secure according to sample.
3. Select the appropriate solenoid lock voltage (12 or 24 VDC).
4. Apply power to the WT1.
5. Once the door device completes its visual and audio signaling, it will unlock
when ANY Wiegand card is presented.
OPERATING
INSTRUCTIONS FOR
LIMITED NUMBER
OF CARDS
NOTES: Failure to
connect the WT1 to the
lock before applying
power result in false
reads.
The WT1 is capable of
remembering up to the
last 20 programmed, or
learned, cards. To clear
all cards from memory,
hold down the learn
button while applying
power.
The door device green
LED flashes.
To initialize the test box for a limited number of specific cards:
1. Connect all wires to the WT1 first.
2. Select Fail Safe or Fail Secure according to sample.
3. Select the appropriate solenoid lock voltage (12 or 24 VDC).
4. Apply power to the WT1.
5. Present a card to the lock.
6. That card is recognized and added to the list of cards that will unlock the
lock. Other cards will not work until each is presented while holding down
the learn button.
NOTES Once a single card/cards are recognized, the door device will no longer
operate by the presentation of any random card until it is been reset.
To reset the device, cycle the power while holding the learn button until it
flashes three times. Any card will then activate the lock.