Seiko Instruments AB000005 Module User Manual 20160616 v1 IFWL 001 rev 160617
Seiko Instruments Inc Module 20160616 v1 IFWL 001 rev 160617
User Manual_20160616_v1 - IFWL-001_User Manual_rev 160617.pdf
IFWL-001 User’s Manual Overview IFWL-001 is a Wireless LAN module for Seiko Instruments Printer. This module provides functions for printing over Wireless LAN. Install and set default value 1. Install IFWL-001 to Printer with 12pin FFC. 2. Turn the power ON and set default value from Web page or USB connection on FFC. Web page: http://192.168.0.1 To set default value with USB connection, use commands by vendor request on USB. For more detail information, please see specifications document. How to use 1. #9100 port Connect #9100 port and send printer command. 2. LPR port Connect LPR port and send data with LPR protocol. 3. #26100 port Connect #26100 port and send SVRP command. Specifications Standard: 802.11b/g/n, 802.11a/n Input voltage: 3.0 to 3.6V Maximum current: 500mA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference, including interference that may cause undesired operation. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Operations in 5150-5250 MHz band is for indoor use only. Requirements to end product This module must be integrated only by OEM integrators under the following conditions. (1) OEM integrator has to be aware not provide information to the users regarding how to install or remove this module in the user’s manual of the end product which integrate this module. Installation by end users is strictly prohibited. (2) Antenna OEM integrator shall use this module without any modifications including antenna. If module integrator uses a unique antenna, the FCC certification is required for the end product. OEM integrator must make sure that 20cm minimum separation is maintained between users and the antenna. (3) Co-location. This module must not be co-located or operated in conjunction with any other antenna or transmitter. The module integrator shall obtain FCC approval for the end product, if the module is used for co-location operation. (4) Markings To satisfy FCC/IC exterior labeling requirements, the following text must be placed on the exterior of the end product. Contains Module FCC ID: C4ZAB000005, IC: 4445A-AB000005 Any similar wording that expresses the same meaning may be used. (5) Caution to user for modification The following caution is expressed on the user’s instruction manual. The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the device. (6) Compliance statement to FCC The following statement is expressed on the user’s instruction manual. For Class A device; NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. For Class B device; NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. (7) Compliance statement to IC The following statement is expressed on the user’s instruction manual. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : 1) l’appareil ne doit pas produire de brouillage; 2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. RF exposure compliance 1) To comply with FCC/IC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. 2) This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. le respect de l'exposition aux RF 1) Afin de se conformer aux normes FCC / IC RF exigences de conformité de l'exposition , une distance de séparation d'au moins 20 cm doit être maintenue entre l'antenne de cet appareil et toutes les personnes . 2) Cet émetteur ne doit pas être situé ou opérant en conjonction avec une autre antenne ou émetteur. Seiko Instruments Inc. 1-8, Nakase, Mihama-ku, Chiba-shi, Chiba 261-8507, Japan Print System Division Telephone:+81-43-211-1106 Facsimile:+81-43-211-8037 Seiko Instruments USA Inc. Thermal Printer Div. 21221 S. Western Avenue, Suite 250, Torrance, CA 90501, USA Telephone:+1-310-517-7778 Facsimile:+1-310-517-7779 Seiko Instruments GmbH Siemensstrasse 9, D-63263 Neu-lsenburg, Germany Telephone:+49-6102-297-0 Facsimile:+49-6102-297-222. Seiko Instruments (H.K.) Ltd. 4-5/F, Wyler Center 2,200 Tai Lin Pai Road, Kwai Chung, N.T., Kowloon, Hong Kong Telephone:+852-2494-5160 Facsimile:+852-2424-0901 (Specifications are subject to change without notice.)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Page Count : 5 Producer : iTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version); modified using iTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version) Create Date : 2016:06:08 10:53:28+09:00 Modify Date : 2016:06:08 10:53:28+09:00 Title : Subject : Creator : CubePDF Author :EXIF Metadata provided by EXIF.tools