Sensitech T11012294 TempTale RF2 Datalogger, RF Temperature Monitor User Manual RF2 System Operating Manual Rev 7

Sensitech, INC. TempTale RF2 Datalogger, RF Temperature Monitor RF2 System Operating Manual Rev 7

User Manual

Download: Sensitech T11012294 TempTale RF2 Datalogger, RF Temperature Monitor User Manual RF2 System Operating Manual Rev 7
Mirror Download [FCC.gov]Sensitech T11012294 TempTale RF2 Datalogger, RF Temperature Monitor User Manual RF2 System Operating Manual Rev 7
Document ID2466023
Application IDyyGOHd2r8E3CBL4HGhTExA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize93.04kB (1162997 bits)
Date Submitted2014-12-07 00:00:00
Date Available2015-06-05 00:00:00
Creation Date2014-04-29 08:04:54
Producing SoftwareGPL Ghostscript 9.02
Document Lastmod2014-04-29 08:04:54
Document TitleRF2_System_Operating_Manual_Rev_7
Document CreatorPDFCreator Version 1.2.1
Document Author: Rdesmarais

TempTale® RF2 System
Installation Manual
T82003843
Revision 7
April 29, 2014
Table of Contents
1.
2.
3.
Overview of the TempTale RF2 System ................................................................................................. 1
1.1.
Important Installation Notes......................................................................................................... 3
1.2.
Mounting the Gateway and Repeater .......................................................................................... 4
TempTale RF2 Gateway ......................................................................................................................... 6
2.1.
Gateway Components................................................................................................................... 6
2.2.
Gateway Assembly ........................................................................................................................ 7
2.3.
RF2 Gateway Specifications ........................................................................................................... 9
TempTale RF2 Repeater....................................................................................................................... 10
3.1.
Repeater Components ................................................................................................................ 10
3.2.
Repeater Assembly ..................................................................................................................... 11
4.
Repeater Specifications ...................................................................................................................... 12
5.
TempTale RF2 Datalogger .................................................................................................................... 13
6.
5.1.
Datalogger Components ............................................................................................................. 13
5.2.
RF Auto-Roaming ........................................................................................................................ 13
5.3.
Logging Data................................................................................................................................ 14
5.4.
Alarms ......................................................................................................................................... 14
5.5.
Datalogger Specifications............................................................................................................ 15
TempTale RF2 Gateway Software........................................................................................................ 16
6.2.
Windows Services \ Applications ................................................................................................ 16
Sensitech Network Manager............................................................................................................... 16
Sensitech Rule Manager ..................................................................................................................... 16
DataTransporter .................................................................................................................................. 17
Configuration Utilities ......................................................................................................................... 17
Sensitech Rule Viewer......................................................................................................................... 17
Sensitech Manual API Updater ........................................................................................................... 17
Declaration of Conformity (DoC) ................................................................................................................ 18
FCC Statement ............................................................................................................................................ 19
Industry Canada Statement ........................................................................................................................ 19
1. Overview of the TempTale RF2 System
The TempTale® RF2 system consists of infrastructure components and dataloggers. The infrastructure
components, TempTale RF2 Gateways (Gateways) and TempTale RF2 Repeaters (Repeaters), are installed
permanently while the TempTale RF2 Dataloggers(Dataloggers) travel with the cargo and report their
data when they arrive at a location that has an installed TempTale RF2 infrastructure.
This manual presents information relevant to Sensitech personnel who have been trained to install the
TempTale RF2 system.
Each location can only have one Gateway installed but many Repeaters. The Gateway receives and
sends data to and from Repeaters using RF signals and also connects to the Internet to make this data
widely available. Repeaters receive and send data or commands to the TempTale RF2 Dataloggers
through RF signals. The infrastructure devices, the TempTale RF2 Gateway and TempTale RF2 Repeaters,
communicate with each other at 2.4 GHz frequencies. However, the system can accommodate smaller
installations as the Repeaters and Gateways can also communicate directly with the TempTale RF2
Dataloggers at 868 MHz or 915 MHz frequencies. This unique feature makes the infrastructure scalable
and flexible for use at large or small installations.
The Gateway consists of a ruggedized, embedded computer loaded with the programs required to read,
process the data and connect to the Internet. The Gateway programs also performs data buffering and
error checking and data decryption to insure data integrity.
Sensitech TempTale RF2 System Installation Manual
Page 1
Revision 7
The layout of the system can be viewed as a tree with the Gateway as the root and Repeaters as nodes.
When planning for the layout of the TempTale RF2 infrastructure, keep in mind that Repeaters can
communicate with other Repeaters, as shown below.
Since the Gateway is also capable of the same functions as Repeaters, a Gateway could also
communicate directly with Dataloggers to download data.
The maximum network coverage for a single Repeater or Gateway is about 80 - 100 meters, but this is
very dependent on the location. To cover more area, the network can be expanded simply by adding
more Repeaters.
Sensitech TempTale RF2 System Installation Manual
Page 2
Revision 7
The following is a diagram illustrating the network layout for a 150 meter x 150 meter warehouse:
1.1.
Important Installation Notes
Regarding RF2 installation, the following important rules must be taken into consideration when
determining where to mount the Gateway and Repeater infrastructure components:
1. The Gateway and Repeater MUST be mounted inside a building, where they would not be
exposed to rain or dripping water. They are designed to be installed in an location with
temperatures in the range of 0C to 40C, 10% to 90% humidity, non-condensing.
2. The Gateway and Repeater MUST NOT be mounted in a location where they would be exposed
to an explosive atmosphere, a corrosive atmosphere or conductive debris.
3. The Gateway and Repeater MUST ONLY be installed with the antennas included in the kit.
Changing antenna types or installation of an outside antenna is not permitted and will void the
Agency Approvals for the system.
4. The Gateway and Repeater MUST ONLY be powered by a +12 Vdc SELV Limited Power Source
only.
5. The RF2 system has been tested for compliance to relevant standards and approved. Changes or
modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED
BATTERIES ACCORDING TO THE INSTRUCTIONS.
Sensitech TempTale RF2 System Installation Manual
Page 3
Revision 7
1.2.
Mounting the Gateway and Repeater
The Gateway enclosure has a set of mounting tabs integrated into the enclosure, and the Repeater is
supplied with a plastic mounting plate. When securing either, the correct fasteners for the wall type
must be used.
For hollow wall construction studded with metal or wood framing and sheathed with Drywall,
Plaster or Plywood, an appropriate hollow wall such as a 3/16” toggle bolt or #10 re-usable
anchor.
Typical drill size is ½” for the 3/16” toggle bolt.
Each of the four Re-Usable Anchors used must be rated for 10 lb. (4.6 kg) minimum and be the
appropriate size for the sheathing thickness. Use #10 size minimum.
Typical drill size is 3/8” for the #10 re-usable anchor shown. Follow the manufacturer’s
instructions.
If the rear side of the sheathing is accessible, it is alternately acceptable to bolt the units to the
wall sheathing using four #10-#12 Pan Head Steel Machine Screws with fender washers and lock
nuts behind the sheathing. Length used must be adequate to fully engage all threads on the
nuts.
For concrete or masonry wall construction, use 3/16” concrete screws. Each of the four screws
must be rated for 10 lb (4.6 kg) minimum.
Typical drill size is 5/32” for the 3/16” concrete screw. Follow the manufacturer’s instructions.
Follow the manufacturer’s recommendation for drill depth for screws being used.
Sensitech TempTale RF2 System Installation Manual
Page 4
Revision 7
Various types of concrete inserts are available that are adequate for use in concrete, such as
conical lead or flanged Polypropylene that will be adequate for installation. They must be
individually rate to support 10 lb. (4.6 kg) minimum. Use sizes that support a #10 screw,
minimum.
Typical drill size is 5/16” for the #10 conical lead anchor for concrete. Follow the manufacturer’s
instructions. Follow the manufacturer’s recommendation for drill depth for insert being used.
Typical drill size is 1/4” for the #10 flanged Polypropylene anchor for concrete. Follow the
manufacturer’s recommendation for drill depth for insert being used.
Sensitech TempTale RF2 System Installation Manual
Page 5
Revision 7
2. TempTale RF2 Gateway
As mentioned previously, the TempTale RF2 Gateway is the core of the infrastructure for the network
and only one Gateway can be installed per facility. The Gateway is a ruggedized, self-contained
embedded computer with four antennas; two of the antennas are for 868 MHz or 915 MHz operation
while the other two antennas are for 2.4 GHz operation. The 2.4 GHz frequency is fixed regardless of
where the Gateway is installed, but the 868 MHz and 915 MHz frequencies are specific to the country of
installation. Some countries use 868 MHz, so when installing in those countries both 868 MHz antennas
must be used. When installing in countries where 915 MHz is the supported standard, two 915 MHz
antennas must be used. A universal power supply is shipped with the Gateway. When ordering the
Gateway, specify the location where it will be installed so Sensitech can provide the power cable with
the correct type of plug.
The TempTale RF2 Gateway components are pictured in the next section.
2.1.
Gateway Components
Sensitech TempTale RF2 System Installation Manual
Page 6
Revision 7
2.2.
Gateway Assembly
When you receive the Gateway, carefully remove it from the shipping container and inspect for damage,
especially if the shipping packaging appears to be damaged. If you determine there has been shipping
damage, contact the carrier immediately.
Determine if 915 MHz or 868 MHz antennas are required, and attach them as indicated in the diagram
below. The 915 MHz antennas have two yellow stripes and the 868 MHz antennas have two gray
stripes.
If you attach the wrong antennas, the RF performance of the Gateway may be degraded.
Sensitech TempTale RF2 System Installation Manual
Page 7
Revision 7
Next, connect the power supply provided at either of the two barrel power connectors provided. You
may need to first loosen the two thumbscrews that hold the securing plate into place. After you slide
the plate back, insert the power connector, slide the plate in place and tighten the thumbscrews.
NOTE: YOU SHOULD ONLY USE THE 12 VDC POWER SUPPLY PROVIDED! USING ANY OTHER POWER
SUPPLY MAY DAMAGE THE GATEWAY. THE SECURING PLATE IS NOT DESIGNED TO PHYSICALLY
SUPPORT THE POWER SUPPLY. DO NOT CONNECT THE REPEATER POWER SUPPLY TO THE GATEWAY!
There are additional connectors under the metal TempTale RF2 nameplate, but they are typically not
required at installation. During installation, the plate should be left in place and only removed under the
direction of Sensitech factory personnel.
Sensitech TempTale RF2 System Installation Manual
Page 8
Revision 7
2.3.
RF2 Gateway Specifications
Input Power
+12Vdc from a SELV limited power source
Weight
6 lbs.(2.75 kg)
RF Band: Gateway to Datalogger
North American ISM Band from 902 – 928 MHz
European SRD Band from 863 to 870 MHz
Frequencies - 915 MHz band
921.5 MHz
923.0 MHz
923.5 MHz
924.0 MHz
924.5 MHz
Frequencies - 868 MHz band
866.1 MHz
866.5 MHz
866.7 MHz
867.1 MHz
867.3 MHz
RF Reading Distance
80 to 100 meters clear-line-of-sight
RF Data Rate
200 Kbit/s at 868 MHz; 250 Kbit/s at 915 MHz
RF Band: Gateway to Repeater
2.4 GHz ISM Band
RF Power Output - 2.4 GHz band
2442
MHz
2443
MHz
2444
MHz
2445
MHz
2446
MHz
2454
MHz
IMPORTANT: The RF2 Gateway contains a CR2032 lithium battery. This battery is not a customer
serviceable item and if replacement is needed, it should be done only by Sensitech personnel.
Sensitech TempTale RF2 System Installation Manual
Page 9
Revision 7
3. TempTale RF2 Repeater
The TempTale RF2 Repeater serves as a connection between the Datalogger and the Gateway. The
Repeater will receive the temperature records from the TempTale RF2 Datalogger and then pass the
data to the Gateway which then delivers the data to the end-user software application or host
computer. An installation may require no Repeaters or many, depending on the coverage area needed.
The Repeater components are pictured in the next section.
3.1.
Repeater Components
Sensitech TempTale RF2 System Installation Manual
Page 10
Revision 7
3.2.
Repeater Assembly
When you receive the Repeater, carefully remove it from the shipping container and inspect for
damage, especially if the shipping packaging appears to be damaged. If you determine there has been
shipping damage, contact the carrier immediately.
Determine if 915 MHz or 868 MHz antennas are required, and attach them as indicated in the diagram
below. The 915 MHz antennas have two yellow stripes and the 868 MHz antennas have two gray
stripes.
If you attach the wrong antennas, the RF performance of the RF2 Repeater may be degraded!
Next, connect the power supply provided at the two barrel power connector provided facing down on
the Repeater enclosure.
NOTE: YOU SHOULD ONLY USE THE 12 VDC POWER SUPPLY PROVIDED! USING ANY OTHER POWER
SUPPLY MAY DAMAGE THE REPEATER. DO NOT CONNECT THE GATEWAY POWER SUPPLY TO THE
REPEATER!
Sensitech TempTale RF2 System Installation Manual
Page 11
Revision 7
4. Repeater Specifications
Input Power
+12Vdc from a SELV limited power source
Weight
2 lbs.(1 kg)
RF Band: Repeater to Datalogger
North American ISM Band from 902 – 928 MHz
European SRD Band from 863 to 870 MHz
Frequencies - 915 MHz band
921.5 MHz
923.0 MHz
923.5 MHz
924.0 MHz
924.5 MHz
Frequencies - 868 MHz band
866.1 MHz
866.5 MHz
866.7 MHz
867.1 MHz
867.3 MHz
RF Reading Distance
80 to 100 meters clear-line-of-sight
RF Data Rate
200 Kbit/s (868 MHz) , 250 Kbit/s (915 MHz)
RF Band: Gateway to Repeater
2.4 GHz ISM Band
RF Power Output - 2.4 GHz band
2442
MHz
2443
MHz
Sensitech TempTale RF2 System Installation Manual
Page 12
2444
MHz
2445
MHz
2446
MHz
2454
MHz
Revision 7
5. TempTale RF2 Datalogger
The TempTale RF2 Datalogger will travel with the cargo and continuously store temperature information
and a corresponding time stamp. The Datalogger will start operation when the “Start” button is
pressed.
The Datalogger also has two LEDs visible on the front panel; the greed LED blinks to indicate that the
Datalogger is operating, taking data points, while the red LED blinks to indicate an error or alarm
condition.
Until a Datalogger enters a TempTale RF2 network, it will remain in low power mode where it does not
transmit but instead wakes up on a specific time interval to collect data. Each time the Datalogger
wakes up, it also checks if it can ‘hear’ the RF signals from a TempTale RF2 infrastructure network. If it
does hear the RF signals, it communicates with the network. The Gateway can then determine what
information it needs from the Datalogger and send the appropriate commands.
Dataloggers also support a secondary download to a local PC using a Sensitech RF download cable. The
Datalogger can be downloaded using the Sensitech ColdStream or TempTale Monitor Download
application (TTMD).
The Datalogger and secondary download cable are pictured in the next section.
5.1.
Datalogger Components
5.2.
RF Auto-Roaming
The TempTale RF2 Gateway and Repeater infrastructure devices can be configured for operation at 868
MHz or 915 MHz, depending where they are installed. The Datalogger will automatically detect the
frequency of the infrastructure and switch to the corresponding frequency for the network detected.
Sensitech TempTale RF2 System Installation Manual
Page 13
Revision 7
5.3.
Logging Data
The Datalogger has the capacity to store 1920 temperature records. When the 1920 record locations
are full, the Datalogger will stop taking new temperature records so no existing temperature records will
be overwritten. The time interval used to store data points is configurable based on the desired length
of operation and is programmed into the Datalogger when shipped.
When the Datalogger is running and no alarms have been triggered, the green LED will flash once every
four seconds. If the Datalogger is stopped and no alarms have been triggered, the green LED will flash
once every eight seconds. If there is no red Alarm LED and no green Status LED flashing, the device has
not been started and is not logging data points.
5.4.
Alarms
Based on programmed parameters, the Datalogger makes its own decision as to whether it is in alarm
and if it is, it flashes a red LED to indicate that. Once the red LED is lighted because of an alarm, the
alarm will be sent to the TempTale RF2 network infrastructure as soon as the Datalogger detects it.
If the red Alarm LED is flashing once every four seconds, this means an alarm was triggered and the
Datalogger is still running. If the LED flashes once every eight seconds, this means an alarm has been
triggered but the Datalogger has stopped taking data point.
There are four different alarm types and the logic behind each is listed below:
Alarm Type
Alarm Logic
Continuous events for high alarm
Alarm will trigger when a certain number of consecutive
temperature records are higher than a predetermined level.
Cumulative events for high alarm
Alarm will trigger when a certain number of cumulative
temperature records are higher than a predetermined level.
Continuous events for low alarm
Alarm will trigger when a certain number of consecutive
temperature records are lower than a predetermined level.
Cumulative events for low alarm
Alarm will trigger when a certain number of cumulative
temperature records are lower than a predetermined level.
Sensitech TempTale RF2 System Installation Manual
Page 14
Revision 7
5.5.
Datalogger Specifications
RF Band: Gateway to Datalogger
North American ISM Band from 902 – 928 MHz
European SRD Band from 863 to 870 MHz
Frequencies - 915 MHz band
921.5 MHz
923.0 MHz
923.5 MHz
924.0 MHz
924.5 MHz
Frequencies - 868 MHz band
866.1 MHz
866.5 MHz
866.7 MHz
867.1 MHz
867.3 MHz
RF Reading Distance
80 to 100 meters clear-line-of-sight
RF Data Rate
200 Kbit/s (868 MHz), 250 Kbit/s (915 MHz)
Anti-Collision
Algorithm accommodates more than 200 active Dataloggers
Battery Life
Shelf
Operation
12 Months
12 Months
Battery Type
Lithium CR123A
Temperature Range
-30 C to +70 C
Temperature Accuracy
Secondary Download Option
-30 C to -10 C
-10 C to +25 C
+25 C to +70 C
+/- 1.0 C
+/- 0.5 C
+/- 1.0 C
Datalogger can be downloaded via USB using Sensitech ColdStream or
TempTale Manager Desktop applications
IMPORTANT: The Datalogger contains a CR123A-type lithium battery and is not removable. If you plan
to dispose of the monitor, it must be done in a manner consistent with local and national regulations for
a device containing a lithium battery of this type.
Sensitech TempTale RF2 System Installation Manual
Page 15
Revision 7
6. TempTale RF2 Gateway Software
6.1.
Software Overview
The program to perform the functionality of the RF2
Gateway is installed on the embedded computer at
the factory.
This program handles 4 main functions:
•
•
•
•
Manage the network and Dataloggers
Download and transmit data to the server
Manage alarms and event triggering
Log network activity
6.2.
Windows Services \ Applications
The functionality required for the Gateway has been divided into a number of different programs and
groups of programs, which are:
•
•
•
•
•
•
Sensitech Network Manager
Sensitech Rule Manager
Data Transporter
LCRF Configuration Utilities
Sensitech Rule Viewer
Sensitech Manual API Updater
Sensitech Network Manager
The Sensitech Network Manager is a service that manages the TempTale RF2 Repeater network, handles
data routing and talks with Dataloggers.
Sensitech Rule Manager
Sensitech Rule Manager is the core of the system and it decides what commands are to be issued to
Dataloggers. It also handles all the rules updates and communicates with Sensitech’s web service.
Sensitech TempTale RF2 System Installation Manual
Page 16
Revision 7
DataTransporter
This is a utility provided by Sensitech to transfer downloaded Datalogger data to Sensitech’s server.
Configuration Utilities
This is the collection of software tools that communicate with the Sensitech Network Manger to allow
an operate to manually issue commands to the Gateway and Repeater network. These tools are usually
used exclusively for diagnostic and testing purpose.
Sensitech Rule Viewer
This is a tool that visually illustrates the rule system. It tracks all the Dataloggers in use in the system
and shows the progress on how the rules are being executed.
Sensitech Manual API Updater
This is a tool for network setup, used before deploying the system for unattended operation.
Sensitech TempTale RF2 System Installation Manual
Page 17
Revision 7
Declaration of Conformity (DoC)
We,
Sensitech, Inc.
800 Cummings Center, Suite 258X
Beverly, Massachusetts 01915-6197 USA
declare under our own responsibility that the product:
Product Description:
Model Number:
Battery powered device that transmits temperature
data and related information by RF
TempTale RF2 Datalogger, TempTale RF2 Gateway, TempTale RF2 Repeater
to which this declaration refers conforms with the relevant standards or other standardizing documents:
EN60950
FCC Part 15
EN300 220
EN 301 489-1 / -3
I understand that the manufacturer would take all the responsibilities for the above product(s).
For and on behalf of
Authorized person
Location
Name:
Position:
Date of issue:
*I hereby declare that I am entitled to sign on behalf of the applicant and that the information supplied is correct and complete.
Sensitech TempTale RF2 System Installation Manual
Page 18
Revision 7
FCC Statement
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada Statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
CAN ICES-3(B)/NMB-3(B)
Sensitech TempTale RF2 System Installation Manual
Page 19
Revision 7

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 21
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : ff3e2213-d1f1-11e3-0000-b507477bfe9b
Producer                        : GPL Ghostscript 9.02
Keywords                        : ()
Modify Date                     : 2014:04:29 08:04:54-04:00
Create Date                     : 2014:04:29 08:04:54-04:00
Creator Tool                    : PDFCreator Version 1.2.1
Document ID                     : ff3e2213-d1f1-11e3-0000-b507477bfe9b
Format                          : application/pdf
Title                           : RF2_System_Operating_Manual_Rev_7
Creator                         : Rdesmarais
Description                     : ()
Author                          : Rdesmarais
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SRMT11012294

Navigation menu