Sensor Developments 90305 User Manual
Sensor Developments Inc.
User Manual
‘ bensor evelo ments Cine. INNOVATIONS |N FORCE MEASUREMENT Phone' (248) 39I-3000 Fax: (248) 39l-0I07 TELEMETRY TRANSMITTER MODEL: 90305 Operators Manual The transmitter consists of a strain gage amplifier, a 4 pole low pass butterworth filter, analog to digital converter, control electronics‘ and a 900MHz radio transmitters Operation of the transmitter is as follows: L Connect the strain gage sensor to the sensor-input pins as shown in figure I. 2, Connect the required gain resistor to the gain pins as shown in figure 1, This resistor sets the full-scale input range of the transmitter. See “Selecting the Gain Resistor” on the next page for more information 3, Select the desired channel by the proper pin combination as shown in table l, Use figure 1 for a reference Grounding the pin inputs a 0. Leaving it unconnected inputs a l. 4. Connect power to the power input pins as shown in figure It Polarity does not matter. Maximum input voltage is 20 volts DC When powered up the unit will transmit the sensor information to the receiver on the same channel, For proper operation the antenna must be kept away from the transmitter. To obtain maximum range, place the antenna far from other metal objects and insure that it is fully extended, Sensor Inputs Battery Connection l +Excitation 12 Input#l \ 2 +Signal 13 Input #2 i 3 -Signal 4 Excitation 5 Gain resistor m 6 Gain resistor 7 Shield ‘BATTERY ANYENNA Channel Selection 8 Ground 9 C80 Mail" P 0an 2917 Lake Orion, MI 4K36l -(J290 www.sendev.com Shipping: 1050 wt Silver Bell Rd. Orion. Ml 48359 lOCSI ll CS2 Fig. 1 — Transmitter Connections Table 1 - Channel Selections Selecting the Gain Resistor Select the gain resistor using the following equation; Rg = (250xfull scale output in mV/V) /(.88 — (1005 xfull scale output in mV/V)) Example; For a 2mV/V full-scale sensor output, using the equation above, we have.., Rg = (250x 2mV/V)/(.88— (.005x2mV/V)) = 500/(.88 - 01) = 500/87 = 575 ohms: Choose the standard resistor value closest to the calculated va uer Do not go under the calculated value by more than 2%, as this will cause the transmitter to overrange with a full-scale load on the sensorr Choose good quality, low temperature drift resistors See table 2 for a list of standard I% resistors to use for gain and the corresponding input ranges Resistor r—Full Scale Resistor I— Full Scale (ohms) Influt (mV/V) __ (ohms) lnmlt (mV/V) 174 .6 698 2,4 226 '— .s 750 2.6 287 110 806 2.8 340 1,2 866 3.0 402 _| 14 —']_ 931 L— 3.2 l_ 464 1,6 976 3.4 523 I— 1.8 _|_ 1050 I 3.6 576 20 1100 3,8 I: 634 _ 2.2 ,_ 1150 4.0 Maul: Shippmg' P.04Box 200 1050 W. Silver Bell Rd. Lake Orimit Ml 4X31iI-11290 Orion. MI 48359 www.sendev.com Table 2 — Input Ranges from Gain Resistors FCC NOTICE This device complies with Part 15 of the FCC rulesi Operation is subject to the following two conditions: I, This device may not cause harmful interference 2, This device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part IS of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation, This device generates, uses, and can radiate radio frequency energy and, if installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in the particular installation If this device does cause harmful interference to radio or television reception, the user is encouraged to try to correct the interference by one or more of the following measures: 1, Reorient or relocate the receiving antenna 2. Increase the separation between the computer and receiver, 3, Connect the computer into an outlet on a circuit different from that to which the receiver is connected 4, Consult the dealer or an experienced radio/TV technician for help. Caution Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. Specifications General Sensor input .......... Sensor input range Gain ................ .Full Bridge Strain Gage .+/-r2mV/V to +/- IOmV/V . table with external resistor Excitation . ,,+SVDC Resolution ‘ (11 bits plus sign) Accuracy ., .. 05% of Full Scale Sample rate 1250 samples/second Low pass filter cutoff iiiii 300HZ Power supply input ..... 6 » 20VDC Power supply current (w/o sensor) xxxx mA Mail. Shipping: Form 290 1050 w Sllvcr Bell Rd. Lake Orion MI “30141290 0mm MI 43359 www,sendev,c0m Temgerature Operation ..... Sensor input an W0— 70 deg C .01% per deg C Recommended Battery TypeA ............................................................................. 9VDC alkaline Approxnmule buttery llfe (350 ohm sensor) xx hrs4 Mail Shipping P OBox 290 mu w. Silver Bell Rd. Lake Orion. M14836I~UZ90 Orion. MI 43359 Wwwvsendcvrom
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Modify Date : 1999:06:08 11:13:12 Creator : Photoshop PDF Plug-in 1.0 Producer : Photoshop PDF Plug-in 1.0 Create Date : 1999:06:08 11:12:27 Page Count : 4EXIF Metadata provided by EXIF.tools