Sensus Metering Systems AMDS1000TR Fixed Microwave Services User Manual 04 0166 User Guide Cover

Sensus Metering Systems Inc. Fixed Microwave Services 04 0166 User Guide Cover

users manual

Download: Sensus Metering Systems AMDS1000TR Fixed Microwave Services User Manual 04 0166 User Guide Cover
Mirror Download [FCC.gov]Sensus Metering Systems AMDS1000TR Fixed Microwave Services User Manual 04 0166 User Guide Cover
Document ID462894
Application IDBFFWJWOTf38sAa5gx32DIA==
Document Descriptionusers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.77kB (97159 bits)
Date Submitted2004-08-25 00:00:00
Date Available2004-08-25 00:00:00
Creation Date2004-08-13 18:11:19
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2004-08-13 14:11:52
Document TitleMicrosoft Word - 04-0166 User Guide Cover.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: Michael Proffitt

Narrowband PCS Transmitter
Certification Test Report
Model: AMDS-1000TR
FCC ID: SDBAMDS1000TR
ACS Report Number: 04-0166-24D
Installation / User’s Guide
Model: AMDS-1000TR
Advanced Compliance Solutions
FCCID: SDBAMDS1000TR
AMDS iCon AMR
Electric Meter
Installation Guidelines
Draft Copy
INTRODUCTION:
The following document briefly describes the installation of an AMDS iCon
Transceiver equipped power meter. The scope of the document is to describe
how to program the meter after proper installation by trained utility company
technicians or licensed electricians.
THIS METER IS ONLY TO BE INSTALLED BY QUALIFIED PERSONNEL!
PROCEDURE:
Confirm that the meter has been installed by a qualified entity or individual.
Turn on the hand-held meter-programming device. (Either the Palm “Zire” or
customized programming device supplied by utility).
Select “Program Electric Meter” when prompted by the meter-programming
device.
Using the wand attached to the meter-programming device, read the bar code on
the front of the power meter (see figure 1 for location). Pass the wand from left
to right over the bar code. A successful read will result in a short beep sound
being generated from the meter-programming device.
After a successful bar code read (i.e. the meter-programming device beeped) the
meter-programming device will prompt the operator to “program device with
magnetic loop”. The magnetic loop is in the wand attached to the meterprogramming device also.
Looking directly at the meter, and mentally superimposing the hands of a clock
on the meter face for reference, place the meter-programming wand at the 3:00
position of the meter face, on the side of the plastic meter cover, touching the
plastic meter cover with the wand. (See photograph below).
Select “Program” on the meter-programming device display. The meterprogramming device will again beep when the meter has been programmed.
Contact your supervisor for confirmation of meter operation.
FCC INFORMATION:
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
•
•
•
•
Reorient of relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet or circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications to this device not expressly approved by
AMDS LLC could void the user’s authority to operate this equipment.
Photograph showing bar code position and 3:00 position for programming wand
placement on meter.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2004:08:13 18:11:19Z
Modify Date                     : 2004:08:13 14:11:52-04:00
Page Count                      : 5
Creation Date                   : 2004:08:13 18:11:19Z
Mod Date                        : 2004:08:13 14:11:52-04:00
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : Michael Proffitt
Metadata Date                   : 2004:08:13 14:11:52-04:00
Creator                         : Michael Proffitt
Title                           : Microsoft Word - 04-0166 User Guide Cover.doc
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SDBAMDS1000TR

Navigation menu