Sensus Metering Systems FXZIG210 Remote Telemetry Module User Manual 72127191 Manual Coverx

Sensus Metering Systems Inc. Remote Telemetry Module 72127191 Manual Coverx

Manual

Download: Sensus Metering Systems FXZIG210 Remote Telemetry Module User Manual 72127191   Manual Coverx
Mirror Download [FCC.gov]Sensus Metering Systems FXZIG210 Remote Telemetry Module User Manual 72127191   Manual Coverx
Document ID3518115
Application IDTPNATlwQcrEK7aLTD4L3vA==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize21.29kB (266170 bits)
Date Submitted2017-08-18 00:00:00
Date Available2017-08-18 00:00:00
Creation Date2017-08-18 11:13:15
Producing SoftwareNuance PDF Create
Document Lastmod2017-08-18 11:14:14
Document TitleMicrosoft Word - 72127191 - Manual Cover.docx
Document CreatorMicrosoft Word - 72127191 - Manual Cover.docx
Document Author: geris-je

Certification Exhibit
FCC ID: SDBFXZIG210
IC: 2220A-FXZIG210
FCC Rule Part: CFR 47 Part 24 Subpart D, Part 101, Subpart C and
15.247
ISED Canada’s Radio Standards Specification: RSS-119, RSS-134 and
RSS-247
TÜV SÜD Project Number: 72127191
Manufacturer: Sensus Metering Systems, Inc.
Model: FXZIG210
Manual
2320 Presidential Drive, Suite 101, Durham, NC 27703 USA Voice: 919-381-4235
Q UI CK G UI DE
FlexNet® SmartPoint® Module
for Aclara i210+c
Quick Guide
The Sensus FlexNet™ SmartPoint® module provides wireless communication capability to electric utility meters. The
Aclara i210+c™ meter is an electronic, single-phase or network, demand and time-of-use (TOU) electricity meter intended primarily for residential applications.
SPECIFICATIONS
The I-210+c meter with the FlexNet module
will have a visible label containing the following information:
Contains
Model: FXZIG210
Contains
FCC ID: SDBFXZIG210
Contains
IC: 2220A-FXZIG210
Technical Overview
The FlexNet communications network offers a simple, reliable, and secure
system that is economical for mass meter deployments, strategic deployments, and rural applications while providing a multi-application solution
for all AMI end points. The FlexNet network enhances the i210+c meter by
providing AMI capability.
The FlexNet SmartPoint module is a printed circuit board which provides
wireless communication capability to the Aclara i210+c electric meter. The
SmartPoint module interrogates the meter registers on a programmable
interval from five minutes to daily readings. The SmartPoint module then
transmits the meter consumption and status information at regular intervals.
Board Location
The module mounts into the existing i210+c meter and acts as a “third
party AMR board.” It is designed to mount mechanically into the meter
with no additional mechanical modification required.
The module communicates via the FlexNet fixed wireless telemetry
network to provide electric meter readings and diagnostic data from the
meter to the utility provider via radio.
The module contains both a receiver and transmitter to allow for two-way
communications over the FlexNet network.
EQG-10006-04
FlexNet® SmartPoint® Module for Aclara i210+c
Warnings & Hazards
WARNING
Sensus devices are for professional installation only. They are to
be serviced by professional personnel only. This product is NOT
for consumer installation or servicing.
WARNING
The antenna used for this transmitter must not be co-located in
conjunction with any other antenna or transmitter.
AT TENTION
Note: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different
form that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for
help
WARNING
If you are not sure of the rated power of your radio, contact your
Sensus representative or dealer and supply the product model
number found on the product label. If you cannot determine the
rated power out, then assure 3-feet separation from the body to
the device.
WARNING
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS
INSIDE. REFER TO QUALIFIED SERVICE PERSONNEL.
R ADIATION HA Z ARD
In order to satisfy the FCC RF exposure limit for transmitting
devices, a separation distance of 20cm (7.87 inches) or more
should be maintained while operating the Sensus FXZIG210. To
ensure compliance, operation at closer than this distance is not
recommended. This minimum safe distance is required between
personnel and the antenna of this device.
R ADIATION HA Z ARD
In order to satisfy the ISED RF exposure limit for transmitting
devices, a separation distance of 29cm (11.4 inches) or more
should be maintained while operating the Sensus FXZIG210. To
ensure compliance, operation at closer than this distance is not
recommended. This minimum safe distance is required between
personnel and the antenna of this device.
Afin de satisfaire à la limite d’exposition RF pour les appareils de
transmission, une distance de séparation de 29cm (11.4 pouces)
ou plus doit être maintenu pendant le fonctionnement du Sensus
FXZIG210. Pour assurer la conformité, un fonctionnement à
distance inférieure à celle est pas recommandée. Cette distance
minimale de sécurité est nécessaire entre le personnel et l’antenne
de cet appareil.
AT TENTION
Any modifications made to this device that are not approved by
Sensus may void the authority granted to the user by the FCC to
operate equipment.
AT TENTION
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes : (1) l’appareil ne doit
pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le fonctionnement.
AT TENTION
This radio transmitter the Sensus FXZIG210 has been approved
by Industry Canada to operate with the antenna types listed
below with the maximum permissible gain and required antenna
impedance for each antenna type indicated. Antenna types not
included in this list, having a gain greater than the maximum
gain indicated for that type, are strictly prohibited for use with
this device.
Le présent émetteur radio (Sensus FXZIG210) a été approuvé
par Industrie Canada pour fonctionner avec les types d’antenne
énumérés ci-dessous et ayant un gain admissible maximal
et l’impédance requise pour chaque type d’antenne. Les types
d’antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour
l’exploitation de l’émetteur.
• 1/4 wave printed monopole with peak gain of 2.77dBi
EQG-10006-04
FlexNet® SmartPoint® Module for Aclara i210+c
Warnings & Hazards
AT TENTION
Under Industry Canada regulations, this radio transmitter may
only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and
its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communication.
Conformément à la réglementation d’Industrie Canada, le présent
émetteur radio peut fonctionner avec une antenne d’un type et
d’un gain maximal (ou inférieur) approuvé pour l’émetteur par
Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l’intention des autres utilisateurs, il faut choisir
le type d’antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire
à l’établissement d’une communication satisfaisante.
AT TENTION
ICES-003 Class B Notice—Avis NMB-003, Class B
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numerique de la classe B est conforme à la norme
NMB-003 du Canada.
8601 Six Forks Rd, Ste 700
Raleigh, NC 27615
1-800-638-3748
sensus.com
©2017 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at either sensus.com/TC or
1-800-638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer.
The Sensus logo is a registered trademark of Sensus.
This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT. FURTHERMORE,
THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR
PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : geris-je
Create Date                     : 2017:08:18 11:13:15-04:00
Modify Date                     : 2017:08:18 11:14:14-04:00
XMP Toolkit                     : 3.1-701
Creator Tool                    : Microsoft Word - 72127191 - Manual Cover.docx
Metadata Date                   : 2017:08:18 11:14:14-04:00
Document ID                     : uuid:7893669c-77cf-7084-9b77-33bb8d7b5563
Instance ID                     : uuid:b9ecca21-08fd-b630-53aa-b8ba447d940b
Producer                        : Nuance PDF Create
Creator                         : geris-je
Title                           : Microsoft Word - 72127191 - Manual Cover.docx
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SDBFXZIG210

Navigation menu