Sensus Metering Systems GS0003 AUTOMATIC GAS METER TRANSMITTER User Manual S175 TX IS1

Sensus Metering Systems AUTOMATIC GAS METER TRANSMITTER S175 TX IS1

USERS MANUAL

Download: Sensus Metering Systems GS0003 AUTOMATIC GAS METER TRANSMITTER User Manual S175 TX IS1
Mirror Download [FCC.gov]Sensus Metering Systems GS0003 AUTOMATIC GAS METER TRANSMITTER User Manual S175 TX IS1
Document ID507916
Application ID98YTqtG0uLGy8Q1jiseSow==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize178.48kB (2230980 bits)
Date Submitted2005-01-20 00:00:00
Date Available2005-01-20 00:00:00
Creation Date2004-12-30 10:19:52
Producing SoftwareAFPL Ghostscript 8.14
Document Lastmod2004-12-30 10:19:52
Document TitleS175_TX_IS1
Document CreatorFreePDF XP 1.3 - http://shbox.de
Document Author: ShimonZ

Automated Meter Reading (AMR)
Transmitter Mounting Instructions
For Schlumberger/Sprague Gas Meters
Applicable Meters
S175, S240, S250, Schlumberger Metris MET250 and S400, with slant index interface.
RF Exposure Note
In order to comply with FCC RF Exposure requirements, the Automatic Meter
Reading unit must be installed in such a way that there is a 20c”m separation
distance between it and all persons during normal operation.
The installer of this radio equipment must ensure that the antenna is located or
pointed such that it does not emit RF field in excess of Health Canada limits for
the general population; consult Safety code 6, obtainable from Health Canada's
website www.hc-sc.gc.ca/rpb
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV
INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.
SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT
AMR Transmitter Mounting Instructions for Schlumberger/Sprague
models S175, S240, S250, MET250, S400 with slant interface
Components
Verify that all the required components for the installation are available:
GS0003 AMR Transmitter
Index cover (supplied with the transmitter)
Hardware
Screw kit (see Appendix – Transmitter Installation Screws as identification
guide):
 3x mounting screws (thread length 1”)
 2x index screws (thread length ⅜”)
 4x index cover screws (thread length ¾”)
 2x snap seals
Tools
Verify that all the required tools for the installation are available:
#2 Phillips screwdriver
Flat screwdriver (blade size ¼”)
Small flat screwdriver (blade size 5/32”)
Stiff blade putty knife
¼” Nut driver
Mint handheld terminal (HHT)
AMR Transmitter Mounting Instructions for Schlumberger/Sprague
models S175, S240, S250, MET250, S400 with slant interface
3
AMR Transmitter Mounting Instructions for Schlumberger/Sprague
models S175, S240, S250, MET250, S400 with slant interface
AMR Transmitter Installation
Installation Tasks
1.
2.
3.
4.
5.
Remove index cover.
Remove index from gas meter.
Mount AMR transmitter onto gas meter.
Assemble index and cover onto AMR transmitter.
Initialize AMR transmitter with HHT.
Remove index cover
1. Use small flat screwdriver to punch out the seals that cover two (2) of the
three (3) index cover screws.
2. Remove and properly dispose the three (3) screws holding the index
cover onto meter, with flat screwdriver. If any screws shear off during
the cover removal (or were previously sheared off), the meter will need
to be replaced by a qualified utility representative. Reinstall any index
cover screws that were removed and cap with seals if possible. Enter the
appropriate information in the Mint HHT and skip to the next work
order.
3. Remove the index cover and dispose of properly.
AMR Transmitter Mounting Instructions for Schlumberger/Sprague
models S175, S240, S250, MET250, S400 with slant interface
Remove index
1. Remove and properly dispose the two (2) screws holding the index onto
the meter, with small flat or Phillips screwdriver.
2. Remove the index and carefully clean any debris from it. Inspect for
proper index operation by turning the input shaft and verifying that the
gearing turns freely. Also, inspect the index for any missing or broken
hands. Place the index, or a new index if necessary, on a clean surface
near you for reinstallation later.
3. With a putty knife, scrap away any gasket material that remained on the
meter when the index cover was removed.
AMR Transmitter Mounting Instructions for Schlumberger/Sprague
models S175, S240, S250, MET250, S400 with slant interface
Mount Transmitter on meter
Verify that the transmitter is functional: check that the magnet on the front cam is
visible; with the HHT check the transmitter ID and validate with the transmitter
label.
Insure the three (3) mounting screws are available and within reach.
Place the AMR Transmitter onto the gas meter. Adjust the Transmitter shaft’s
position by holding it on the front side, and combine the Transmitter shaft
gearwheel with the gas meter shaft gearwheel.
1. While holding the Transmitter in place, check that the shafts are correctly
positioned by gently rotating the Transmitter’s shaft with your other
hand. There should be just a slight freedom of motion.
2. Attach the Transmitter to the meter using the three (3) mounting screws
with a Phillips screwdriver. Place all screws, then torque down the top
screw. Check shaft motion transfer again, then tighten the last two (2)
screws.
3. Should any screws shear or strip during the installation, the meter will
need to be replaced by a qualified utility representative. Remove the
transmitter and reinstall the index and index cover on the meter with the
original screws. Enter the appropriate information in the Mint HHT and
skip to the next work order.
AMR Transmitter Mounting Instructions for Schlumberger/Sprague
models S175, S240, S250, MET250, S400 with slant interface
Assemble index and new cover onto
transmitter
1. Install the two (2) index screws to their place in the Transmitter with the
Phillips screwdriver. Do not insert the screws fully, to leave space for the
index to slide in.
2. Align the index shaft with the Transmitter’s shaft; adjust the wriggler’s
position by holding the proving hand on the index front side, and insert
so that there is no interference.
3. Tighten the index screws, securing the index to the Transmitter.
AMR Transmitter Mounting Instructions for Schlumberger/Sprague
models S175, S240, S250, MET250, S400 with slant interface
4. Install the index cover supplied (it only fits in one direction – the bump
fits in the right side of the Transmitter). Check that the gasket is properly
aligned and fasten to the Transmitter with the four (4) index cover
screws.
CAUTION
Use care when working with a
power screwdriver to insert screws
in the plastic Transmitter box. Over
tightening will damage the box
and/or weaken the contact.
5. Install the two snap seals in the index cover and insert fully with the aid
of a ¼” nut driver. Align the end of the nut driver on the snap seal and
tap the end of the nut driver handle with your hand until it is fully seated.
AMR Transmitter Mounting Instructions for Schlumberger/Sprague
models S175, S240, S250, MET250, S400 with slant interface
Initialize AMR Transmitter with HHT
On operating the Mint HHT, see Gas AMR Installation HHT (Mint) User’s
Guide. When you are ready to initialize (program) the AMR Transmitter,
position the HHT with the upper back part of the HHT against the Transmitter
receive area (see below) and press the PRG key (7-dot mark).
AMR Transmitter Mounting Instructions for Schlumberger/Sprague
models S175, S240, S250, MET250, S400 with slant interface
Appendix – Transmitter
Installation Screws
Mounting Screws
1.
Equimeter/Rockwell commercial meter (e.g. R750) –
2.
American commercial meter (e.g. AL800) – #18-18 x 84 Phillips pan head
3.
American residential meter (e.g. AC250) –
4.
Schlumberger/Sprague residential meter (e.g. S175) – 10-24 x 1” Phillips fillister
5.
Equimeter/Rockwell residential meter (e.g. R275) – 10-24 x ¾” Phillips fillister
5/16” x 3½” combo fillister
¼” x 1” Phillips fillister
Index Screws
6.
Equimeter/Rockwell commercial meter (e.g. R750) – WN1411 KA 60x14 Phillips
8.
Equimeter/Rockwell residential meter (e.g. R275) – WN1412 KA 35x22 Phillips
9.
American & Schlumberger/Sprague residential meter– WN1411 KA 40x12 Phillips
Index Cover Screws
7.
All residential meters – WN1412 KA 50x20 Phillips
10
AMR Transmitter Mounting Instructions for Schlumberger/Sprague
models S175, S240, S250, MET250, S400 with slant interface

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 10
Producer                        : AFPL Ghostscript 8.14
Create Date                     : 2004:12:30 10:19:52
Modify Date                     : 2004:12:30 10:19:52
Title                           : S175_TX_IS1
Creator                         : FreePDF XP 1.3 - http://shbox.de
Author                          : ShimonZ
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KCHGS0003

Navigation menu