Sharper Image 203758

User Manual: Sharper Image Filterless Silent UV Air Purifier @ Sharper Image

Open the PDF directly: View PDF PDF.
Page Count: 8

Owners
Manual
This Manual Includes:
• Warranty
• Safety Warnings
• Operating Instructions
• Replacement Directions
• Troubleshooting Tips
• Cleaning and Maintenance Tips
Before operating this unit, carefully
read the contents of this manual.
Filterless UV
Air Purifier
Item No. 203758
Read all instructions carefully before operating
your air purier.
Table of Contents
Table of Contents 1
Safety Instructions and Cautions 2
Warranty 3
Maintenance and Customer Service 4
Placement and Operation 4
Cleaning 4
AHPCO™ Cell Replacement 5-6
Troubleshooting Guide 7
1
WARNING: UV Light Hazard. Harmful to skin and eyes. Can cause
temporary or permanent loss of vision. Never look at the lamp while
illuminated. To prevent exposure to ultraviolet light, be sure the pow-
er is disconnected before servicing.
WARNING: RISK OF ELECTRICAL SHOCK. CAN CAUSE INJU-
RY OR DEATH: UNPLUG OR DISCONNECT UNIT FROM POWER
SUPPLY BEFORE SERVICING.
Replacement Date Reminder
The AHPCO™ Cell should be replaced at least every three years.
Replacement Date:_________________
Hg lamp contains mercury. Manage in accord with disposal laws.
Find disposal centers at www.earth911.org.
2
Important Safety Instructions
When operating electrical appliances, basic precautions should always be
followed.
WARNING To reduce the risk of re, electric shock or injury:
• Do not use outdoors or on wet surfaces.
• Use only as described in this manual.
Do not use with a damaged cord or plug. If appliance is not working as it should,
has been dropped, damaged, left outdoors, or dropped into water, call Customer
Service at 1-877-210-3449.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
• Do not handle plug or appliance with wet hands.
Do not put any object into openings.
• Turn off all controls before unplugging.
CAUTION
AHPCO™ Cell contains Hg (Mercury) and should be disposed of according to
disposal laws. Find disposal centers at www.earth911.org.
If the UV lamp is broken do not touch the cell or glass with your hands.
UV lamp may be hot and could cause serious burns if not handled properly. Please
wait until the AHPCO Cell has cooled to room temperature to remove from unit.
Warranty
Sharper Image gives you the following limited warranty for this product only if it
was originally purchased directly from Sharper Image.
Sharper Image will repair or replace, free of charge, to the original purchaser,
any part that is found to be defective in material or workmanship within
one (1) year of the date of purchase.
This limited warranty covers the replacement of expendable or consumable parts
such as the AHPCO Cell for one (1) year.
This limited warranty does not apply to any part subjected to accident, abuse,
industrial use, alteration, misuse, damage caused by act of God, the use of
voltages other than indicated on the label displayed on this product or service of
this product by anyone other than Sharper Image.
Sharper Image does not authorize any person or representative to assume or
grant any other warranty obligation with the sale of this product.
Sharper Image’s limited warranty is valid only if you retain proof of purchase from
Sharper Image or a Sharper Image Authorized Retail Dealer for this product. If
you purchase this product from any other source, your purchase is “AS IS”, which
means Sharper Image grants you no warranty, and that you, not Sharper Image,
assume the entire risk of the quality and performance of this product, including the
entire cost of any necessary servicing or repairs of any defects.
Sharper Image’s liability for damages to you for any costs whatsoever arising out
of this statement of limited warranty shall be limited to the amount paid for this
product at the time of original purchase, and Sharper Image shall not be liable for
any direct, indirect, consequential or incidental damages arising out of the use or
inability to use this product.
ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT,
INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION
TO THE WARRANTY PERIOD, AND NO WARRANTIES, WHETHER
EXPRESS OR IMPLIED, WILL APPLY AFTER THIS PERIOD.
Some states do not allow limitations on the duration of implied warranties, so the
above limitation may not apply to you. This warranty gives you speci ic legal
rights, and you may also have other rights which vary from state to state.
For return authorization and a prepaid return label,
call 1-877-714-7444.
3
Maintenance and Customer Service
Placement and Operation
Optional Cleaning
If you require any additional information or have problems with your Sharper
Image appliance, you may call Customer Service at: 1-877-714-7444.
Please have your serial and model numbers, found on bottom of unit, handy when
calling.
Save your sales receipt to show if your Sharper Image appliance should ever need
any warranty service.
Off / On
Switch
Make sure that the power cord is unplugged prior to cleaning.
Base and Honeycomb - We recommend wiping with a dry towel to remove dust
and build up.
Aluminum Shell - We recommend using stainless steel/aluminum spray on polish
or multi-surface cleaners. Make sure the polish or cleaner is recommended for
use on aluminum.
Internal - Take a dry cloth and wipe inside the shell and around the aluminum
brackets and the ballast or spray with compressed air.
NOTE: Use compressed air only to clean the AHPCO Cell. Any removal of cata-
lyst coating will decrease the effectiveness of your unit and void the warranty.
For best results the unit should be placed in a central location, and three
feet or higher from the ground.
Operation is very simple. Remove the device from the packaging. Place it
in the desired location, plug it in and rock the switch to the on position. The
unit can remain in the on position 24/7.
4
AHPCO™ Cell Replacement
Step 1
CAUTION: Before attempting to service the Sharper Image unit, be sure
the power is off and unplugged.
DANGER - NEVER LOOK DIRECTLY AT ILLUMINATED AHPCO CELL
1. Remove two (2) screws at the
bottom sides holding outer shell
in place. Then slide the shell up
and off of the internal base.
Step 2
Step 3
3. Grasp the AHPCO Cell and pull
upward to release from bracket
then remove the lamp connector.
2. Use a 5/16 inch socket to
remove the nuts from the AHPCO
Cell.
CAUTION
UV lamp may be hot and could cause
serious burns if not handled properly.
Please wait until AHPCO Cell has cooled
to room temperature to remove from unit.
5
WARNING
OPTICAL RADIATION EXPOSURE HAZARD
DO NOT ATTEMPT TO OPERATE UNIT WITHOUT
ALLUMINUM SHELL COVERING AHPCO CELL.
DO NOT ATTEMPT TO REPLACE AHPCO
CELL WITHOUT DISCONNECTING POWER.
PERMANENT EYE AND SKIN DAMAGE MAY RESULT.
Step 4
Step 5
Step 6
4. Connect the lamp connector
securely onto the AHPCO Cell.
6. Slide shell down onto base and
replace screws. (Cord and
switch are to the back.)
5. Use a 5/16 inch socket to
tighten nuts to secure the AHPCO
Cell.
6
Troubleshooting Guide
Problem Reason Solution
Unit does not turn on. 1. Power Supply
2. Switch
3. AHPCO™ Cell
1. Check to make
sure power supply is
plugged in.
2. Check to make sure
switch is in the on
position.
3. Check to make
sure UV lamp within
AHPCO™ Cell in
plugged in completely.
There is a beeping
sound.
1. Defective AHPCO™
Cell or the AHPCO
Cell is unplugged
1. Check to make sure
the AHPCO™ Cell’s
four pins are plugged
in completely and the
cell has a blue glow.
If you see no glow,
contact Sharper Image
Customer Service.
Customer Service number: 1-877-210-3449 (TOLL FREE)
Monday - Friday, 9:00 a.m. to 6:00 p.m. EST
Email customerservice@sharperimageonline.com.
Please include where the product was purchased from,
as well as the date that the product was purchased.
Sharper Image® name and logo are registered trademarks.
Manufactured and Marketed by Camelot SI, LLC under license.
© Sharper Image. All Rights Reserved.

Navigation menu