Sheenway Asia ZW3102 dimmer switch with power consumption measurement User Manual 45652

Sheenway Asia Ltd. dimmer switch with power consumption measurement 45652

user manual

Download: Sheenway Asia ZW3102 dimmer switch with power consumption measurement User Manual 45652
Mirror Download [FCC.gov]Sheenway Asia ZW3102 dimmer switch with power consumption measurement User Manual 45652
Document ID1374882
Application IDOYNdpF6+88v53P4e/tBvnw==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize10.17kB (127115 bits)
Date Submitted2010-11-11 00:00:00
Date Available2010-11-11 00:00:00
Creation Date2010-08-25 10:11:24
Producing SoftwareAcrobat Distiller 8.2.3 (Windows)
Document Lastmod2010-09-02 14:00:41
Document TitleMicrosoft Word - 45652 user manual.doc
Document CreatorPScript5.dll Version 5.2
Document Author: ryan

45652 Instructions
8/25/2010 10:11:20 AM
45652
Wireless Lighting Control
Energy Monitoring Lamp Dimmer
R Z-Wave® Certified Wireless Lighting Control
Add callouts for Z-Wave
outlet and
Program/Manual control
pushbutton
Thank you for your purchase of a GE Z-Wave® control device. Z-Wave technology is designed to automate
lighting/home control and provide easy remote operation of all your Z-wave enabled devices. The GE Z-Wave
product family includes a variety of devices to control lighting in your home. It is up to you whether you want to
control one room or your entire house and whether you want to do it all now or start with one room and add more
over time.
This module is one component of a Z-Wave® control system and is designed to work with all other Z-Wave enabled
devices in a home control network. It will also act as a wireless repeater to insure that commands intended for
another device in the network are received, thereby extending the range of the wireless controller. Z-Wave devices
of other types and brands can be added to the system and will also act as range extenders if they support this
function of repeating the signal received to other nodes in the system.
The incandescent lighting plugged into the Z-Wave controlled outlet on this module must not exceed 400 watts. DO
NOT use with fluorescent lighting. Plugging a non-resistive load such as fluorescent lighting or a device with a
motor into the Z-Wave controlled outlet may result in damage to the Lamp Module and will void the warranty.
There are no user serviceable parts in this unit.
To reduce the risk of electric shock, this product has a grounding type plug that has a third (grounding) pin. This plug
will only fit into a grounding type power outlet. If the plug does not fit into the outlet, contact a qualified electrician to
install the proper outlet. Do not change the plug in any way.
Page 1 of 7
45652 Instructions
8/25/2010 10:11:20 AM
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
The Load-Sense feature on this Z-Wave product will turn the power to the connected device ON when a change in
the load is detected. Z-Wave connected devices should always be unplugged before performing any service or
maintenance of the devices.
Controlling Appliances:
Exercise extreme caution when using Z-Wave devices to control appliances. Operation of the Z-Wave device may
be in a different room than the controlled appliance, also an unintentional activation may occur if the wrong button on
the remote is pressed. Z-Wave devices may automatically be powered on due to timed event programming.
Depending upon the appliance, these unattended or unintentional operations could possibly result in a hazardous
condition. For these reasons, we recommend the following:
1. Assign Z-Wave controlled appliances to device numbers 10 – 18 on the GE remote. The likelihood of
unintentionally turning on the appliance will be reduced significantly because the “Shift” button will need to
be pressed before pressing device numbers 10-18.
2. Z-Wave devices controlling appliances should be removed from “All” control setting. Instructions on how to
do this are included in the manual for your GE remote.
3. Do Not include Z-Wave devices in Groups or Scenes if they control appliances.
4. Do Not use Z-Wave devices to control electric heaters or any other appliances which may present a
hazardous condition due to unattended or unintentional or automatic power on control.
5. Double check programs for accuracy before using them.
NOT FOR USE WITH MEDICAL OR LIFE SUPPORT EQUIPMENT
Z-Wave enabled devices should never be used to supply power to or control the On/Off status of medical
and/or life support equipment!
Wireless Range
This device complies with the Z-Wave standard of open-air, line of sight transmission distances of 65 feet. Actual
performance in a home depends on the number of walls between the remote controller and the destination device,
the type of construction and the number of Z-Wave enabled devices installed in the control network. Most Z-Wave
enabled devices act as a signal repeater and multiple devices result in more possible transmission routes which
helps eliminate “RF dead-spots”.
Things to consider regarding RF range:
• Each wall or obstacle (i.e.: refrigerator, big screen TV, etc.) between the remote or a Z-Wave device and the
destination device will reduce the maximum range of 100 feet by approximately 25-30%.
• Brick, tile or concrete walls block more of the RF signal than walls made of wooden studs and plasterboard
(drywall).
• Wall mounted Z-Wave devices installed in metal junction boxes will suffer a significant loss of range
(approximately 20%) since the metal box blocks a large part of the RF signal.
Page 2 of 7
45652 Instructions
8/25/2010 10:11:20 AM
Effects of Home Construction on Wireless Range Between Z-Wave Enabled Devices
Note: The distances shown in the table below are typical examples. Actual performance in your home will vary.
From the Remote (or repeating Z-Wave module) to destination device:
Number of Walls
or Obstacles
0**
Type of Construction
Wood Frame w/Drywall
Plastic JMetal JBoxes*
Boxes
100'
80'
70'
56'
49'
39'
34'
27'
Brick, Tile or Concrete
Plastic JMetal JBoxes*
Boxes
100'
80'
60'
48'
36'
29'
21'
17'
* For Plug-in Modules or In-Wall Devices Installed in Plastic Junction Boxes
** Line of Sight / no obstructions
Please Note: Z-Wave home control networks are designed to work properly alongside 802.11 wireless computer
networks, Bluetooth and 2.4GHz, 5.8GHz or DECT devices. Some baby cams, wireless video devices and older
cordless phones using the 900MHz frequency range may cause interference and limit Z-Wave functionality. Many
900MHz products have a switch to select channel “A” or “B”. You may find that one of these channels will cause less
interference than the other.
Key Features
•
•
•
•
One Z-wave controlled AC outlet for standard incandescent lighting
o Remote ON/OFF and Brightness control via the Z-Wave controller
o Manual ON/OFF and Brightness control with the front panel pushbutton
o Load-Sensing turns the light ON if the switch on the connected light is used instead of the remote or
pushbutton on the Z-Wave module
Monitors and reports energy values and Watts consumed by the connected device
Space efficient design
o Does not block the lower outlet when plugged in to the upper outlet of a duplex wall receptacle.
(This assumes that the duplex receptacle is mounted with the ground pin down.)
o Plugs and cords for connected devices route to the side allowing close placement of furniture
Grounded 3-wire power connection for safety
Energy Monitoring
This unit incorporates special circuitry to capture and report energy values and the Wattage consumed by the device
plugged into it.
• This energy related data includes Voltage (V), Current (A), Watts (W), Kilowatt hours (KWh) and Power
Factor (PF). V, A, W & PF are instant readings taken at the time of the request while KWh is an
accumulated value.
• This unit is capable of storing readings up to 10,000 KWh. It will automatically reset to zero and start over
when it reaches 10,000. It will also reset and start over if the power to it is turned off.
• The Z-Wave controller must poll (request) the information from the device.
• The energy data is transmitted using Z-Wave’s Meter Command Class v3. If the unit receives a request for
this data from a controller supporting the Meter CC v1, it will report KWh as its default scale.
• Meter Reset is supported so if desired, the unit can delete its previous meter readings and start accumulating
new KWh data.
Page 3 of 7
45652 Instructions
8/25/2010 10:11:20 AM
Basic Operation
The connected light can be turned ON in three ways:
1. With a remote
2. Manually with the pushbutton on the Z-Wave module
3. By the Load-Sensing feature. Normally, the Z-Wave module controls the ON/Off state of the connected light
and power is either turned On or Off at the module (either manually or by the remote). If the switch on the
connected light is used, the Z-Wave control circuitry automatically senses that the light is being turned On
and activates the Z-wave controlled outlet, providing power to the connected device. This feature is disabled
by default; see the section on advanced operation for instructions on how to enable it.
Remote Control
GE Z-Wave remotes provide control of an Individual device, Groups of devices and Scenes. Other brands of ZWave Certified remotes may not offer as much flexibility in how you can set up your lighting control network. Please
refer to your remote control’s instructions for details on its capabilities and instructions for adding and controlling
devices.
Manual Control
The Front Panel Pushbutton on the 45652 Lamp Module allows the user to:
1. Manually turn the connected lighting ON/OFF by pressing the button.
• This is a toggle switch; if the light is OFF, pressing the button turns the light ON and vice versa.
2. Adjust the brightness level of the connected lighting by pressing and holding the button. Release the button
when the desired level is attained.
• This is also a toggle function. The lighting will dim until the minimum level is attained or the button is
released. The next time the button is pressed and held, the level will increase until the maximum level is
attained or the button is released.
3. Include or exclude the module from the Z-Wave home control network with your primary controller.
• Refer to the instructions for your primary controller to access the setup function and include or exclude
devices.
• When prompted by your primary controller, tap the button (press and release).
• The primary controller should indicate that the action was successful. If the controller indicates the
action was unsuccessful, please repeat the procedure.
• Once the module is part of the network, the same basic procedure is used to add the module to groups
or scenes. Refer to the primary controller’s instructions for details.
Please Note: After a power failure, the 45652 module returns to its last used ON/OFF/DIM state.
ADVANCED OPERATION
The following Advanced Operation parameters require that you have an advanced controller like the GE model
45601 LCD remote. Advanced remotes from other manufacturers may also be able to change these settings;
however, basic remotes do not have this capability.
All On/All Off
Depending upon your primary controller, the 45652 lamp module can be set to respond to ALL ON and ALL OFF
commands in up to four different ways. Some controllers may not be able to change the response from its default
setting. Please refer to your controller’s instructions for information on whether or not it supports the configuration
function and if so, how to change this setting.
The four possible responses are:
• It will respond to ALL ON and the ALL OFF commands (default).
• It will not respond to ALL ON or ALL OFF commands.
• It will respond to the ALL OFF command but will not respond to the ALL ON command.
Page 4 of 7
45652 Instructions
•
8/25/2010 10:11:20 AM
It will respond to the ALL ON command but will not respond to the ALL OFF command.
Load Sensing
Load sensing is disabled when shipped from the factory. This feature can be enabled if desired. Setting parameter
29 to a value of 1 will enable the Load Sense function.
•
•
•
Parameter No: 29
Length: 1 Byte
Valid Values = 0 or 1 (default 0)
Note: When replacing a burned-out light bulb, the load sensing feature (if enabled) will automatically turn the light
ON when the new bulb is installed even if the Z-wave module was previously turned OFF.
Dim Rate Adjustments
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit
personal preferences. The timing of the steps can be adjusted in 10 millisecond intervals. As an example, the
default setting for parameter 8 is “3”. This means that the lighting level will change every 30 milliseconds when the
Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined,
the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum
or minimum-to-maximum brightness levels.
1. When Receiving a Z-Wave Dim Command
• Parameter 7 (number of steps or levels)
• Parameter 8 (timing of the steps)
• Length: 1 Byte
• Valid Values:
Parameter 7 (default = 1) Valid Values: 1-99
Parameter 8 (default = 3) Valid Values: 1-255
2. Manual Control Dimming (pressing the Dimmer’s rocker)
• Parameter 9 (number of steps or levels)
• Parameter 10 (timing of the steps)
• Length: 1 Byte
• Valid Values:
Parameter 9 (default = 1) Valid Values: 1-99
Parameter 10 (default = 3) Valid Values: 1-255
3. When Receiving an All-On or All-Off Command
• Parameter 11 (number of steps or levels)
• Parameter 12 (timing of the steps)
• Length: 1 Byte
• Valid Values:
Parameter 11 (default = 1) Valid Values: 1-99
Parameter 12 (default = 3) Valid Values: 1-255
Ignore Start Level When Receiving Dim Commands
Please note: Every “Dim” command from your remote controller includes a start level embedded in it.
The 45652 can be set to ignore the start level that is part of the dim command. Setting parameter 5 to a value of 0
will cause the 45652 to dim or brighten from the start level embedded in the command.
• Parameter No: 5
• Length: 1 Byte
• Valid Values = 0 or 1 (default 1)
Page 5 of 7
45652 Instructions
8/25/2010 10:11:20 AM
Restoring Factory Defaults
All network settings and configuration parameters can all be restored to their factory default settings by using your
master controller to delete it from your network.
Software Fuse
This Lamp Module is designed to protect itself against loads that exceed its maximum power rating. An overload is
automatically sensed by the module and all power to the load is shut OFF immediately.
Troubleshooting: Verify that the lamp wattage does not exceed the 400W rating if the module doesn’t seem to work
properly. Normal operation can be restored by remote when the load is reduced to the proper rating.
Over-Current Protection
Additional over-current protection is provided by an internal fuse which is not user serviceable. Check your home’s
circuit breakers before concluding that the product must be replaced.
Interoperability with Z-Wave™ Devices
A Z-Wave™ network can integrate devices of various classes, and these devices can be made by different
manufacturers. Although every Z-Wave certified product is designed to work with all other Z-Wave certified products,
your controller must include the appropriate device classifications in order to control non-lighting Z-wave devices. As
an example, the GE 45600 basic remote is designed only for controlling Z-Wave devices using the lighting control
classification. The GE 45601 deluxe remote with LCD readout can control other Z-Wave certified devices like
thermostats as well as lighting.
WARRANTY
JASCO Products warrants this product to be free from manufacturing defects for a period of two years from the
original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and
does not extend to consequential or incidental damage to other products that may be used with this product. This
warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an
implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above
limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which
vary from state to state. Please contact Customer Service at 800-654-8483 (option 4) between 7:30AM – 5:00PM
CST or via our website (www.jascoproducts.com) if the unit should prove defective within the warranty period,
JASCO Products Company
Building B
10 E Memorial Rd.
Oklahoma City, OK 73114
FCC
U2ZZW3102
The Federal Communication Commission Radio Frequency Interference Statement includes the following paragraph:
The equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment uses, generates and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction, may cause harmful interference to radio communication. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Page 6 of 7
45652 Instructions
8/25/2010 10:11:20 AM
Operation is subject to the following two conditions:
• This device may not cause interference
• This device must accept any interference, including interference that may cause undesired operation of the
device.
Important Note:
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the device.
FCC/IC RF Radiation Exposure Statement:
1.To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted.
Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void
user’s authority to operate the device.
2.This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This
equipmentshould be installed and operated with a minimum distance of 20 centimeters between the radiator and your
body.
Compliance with IC Rules and Regulations
IC: 6924A-ZW3102
Jasco Products Company
Model: 45652
ZW3102
This Class B digital device complies with Canadian ICES-003.
SPECIFICATIONS
Power 120VAC, 60Hz
Signal (Frequency) 908.42 MHz
Maximum load: 3.3A, 400W Incandescent
Z-Wave controlled outlet is fused @ 6.3A. This fuse is not user serviceable.
Range: Up to 100 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module.
Energy Monitoring Values: Voltage (V), Current (A), Watts (W), Kilowatt hours (KWh) and Power Factor (PF)
Operating Temperature Range: 32-104° F (0-40° C)
For indoor use only.
Specifications subject to change without notice due to continuing product improvement
Z-Wave is a registered US trademark of Sigma Designs
© 2010 JASCO Products Company
Page 7 of 7

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39
Format                          : application/pdf
Title                           : Microsoft Word - 45652 user manual.doc
Creator                         : ryan
Create Date                     : 2010:08:25 10:11:24+08:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2010:09:02 14:00:41+08:00
Metadata Date                   : 2010:09:02 14:00:41+08:00
Producer                        : Acrobat Distiller 8.2.3 (Windows)
Document ID                     : uuid:cadaf6f6-4431-45f7-bfec-9771359d1cc5
Instance ID                     : uuid:efe4bf52-f9bf-4953-99f8-676a79584cd1
Page Count                      : 7
Author                          : ryan
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U2ZZW3102

Navigation menu