Sheenway Asia ZW4002 Wireless relay switch User Manual 45743 English Manual 012113

Sheenway Asia Ltd. Wireless relay switch 45743 English Manual 012113

User manual

Download: Sheenway Asia ZW4002 Wireless relay switch User Manual 45743 English Manual 012113
Mirror Download [FCC.gov]Sheenway Asia ZW4002 Wireless relay switch User Manual 45743 English Manual 012113
Document ID1980612
Application ID5xVkvE2oIrhjaqOg7UcdgQ==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize297.15kB (3714334 bits)
Date Submitted2013-06-03 00:00:00
Date Available2013-06-03 00:00:00
Creation Date2013-05-30 16:56:24
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2013-05-30 16:56:24
Document Title45743 English Manual 012113.pdf
Document CreatorPScript5.dll Version 5.2.2
Document Author: Jacky Koo

JAeSCO®
Ceretiifd
Wireles Liirghthtl
On/Off/Dim
Dimmer Switch
@vgriwaév 45743(ZW4002)
IU/ Made in China
Introduction:
Thank you for your purchase of a Jasco Z-Wave® control
device. Z-Wave technology is designed to automate
lighting/home control and provide easy remote operation
of all your Z-Wave enabled devices. The Jasco Z-Wave
product family includes a variety of devices to control
lighting in your home. It is up to you whether you want to
control one room or your entire house and whether you
want to do it all now or start with one room and add more
over time.
This dimmer is one component of
a Z-Wave® control system and is
designed to work with all other
Z-Wave enabled devices in a home
control network. It will also act
as a wireless repeater to insure
that commands intended for
another device in the network
are received, thereby extending
the range of the wireless
controller. Z-Wave devices
of other types and brands
can be added to the system
and will also act as range
extenders if they support
this function of repeating
the signal received
to other nodes in the
system.
A CAUTION
This device is intended for installation in accordance
with the National Electric Code and local regulations
in the United States, or the Canadian Electrical Code
and local regulations in Canada. If you are unsure or
uncomfortable about performing this installation
consult a qualified electrician.
This switch is designed for use only with
permanently installed incandescent fixtures. Do
not use it to control fluorescent lighting, transformer
supplied lighting/appliances or receptacles. The
incandescent lighting controlled by this dimmer
switch must not exceed 600 watts.
NOT FOR USE WITH MEDICAL OFI LIFE SUPPORT EQUIPMENT
Z-Wave enabled devices should never be used
to supply power to or control the On/Off status
of medical and/or life support equipment!
There are no user serviceable parts in this
unit.
Dimmer switch
LED light
Air gap switch
WARNING
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
Controlling Appliances:
Exercise extreme caution when using Z-Wave devices to
control appliances. Operation of the Z-Wave device may
be in a different room than the controlled appliance, also an
unintentional activation may occur if the wrong button on the
remote is pressed. Z-Wave devices may automatically be
powered on due to timed event programming. Depending upon
the appliance, these unattended or unintentional operations
could possibly result in a hazardous condition. For these
reasons, we recommend the following:
1. Assign Z-Wave controlled appliances to device
numbers 10 — 18 on the Jasco remote. The likelihood of
unintentionally turning on the appliance will be reduced
significantly because the “Shift” button will need to be
pressed before pressing device numbers 10-18.
Z-Wave devices controlling appliances should be
removed from “All” control setting. Instructions on how
to do this are included in the manual for your Jasco
remote.
Do Not include Z-Wave devices in Groups or Scenes if
they control appliances.
Do Not use Z-Wave devices to control electric heaters
or any other appliances which may present a hazardous
condition due to unattended or unintentional or
automatic power on control.
Double check programs for accuracy before using them.
Wireless Range
This device complies with the Z-Wave standard of open-
air, line of sight transmission distances of 65 feet. Actual
performance in a home depends on the number of
walls between the remote controller and the destination
device, the type of construction and the number of
Z-Wave enabled devices installed in the control network.
Every Z-Wave enabled device acts as a signal repeater
and multiple devices result in more possible transmission
routes which helps eliminate “RF dead-spots”.
Things to consider regarding RF range:
- Each wall or obstacle (i.e.: refrigerator, big screen TV,
etc.) between the remote or Z-Wave device and the
destination device will reduce the maximum range by
approximately 25-30%.
- Brick, tile or concrete walls block more of the RF signal
than walls made of wooden studs and plasterboard
(drywall).
- Wall mounted Z-Wave devices installed in metal
junction boxes may suffer a significant loss of range
(approximately 20%) since the metal box blocks a large
part of the RF signal.
Effects of Home Construction on Wireless Range
Between Z-Wave Enabled Devices.
Note: The distances shown in the table below are typical
examples. Actual performance in your home will vary.
From the Remote (or repeating Z-Wave module) to
destination device:
Type of Construction
Wood Frame Brick, Tile or
w/Drywall Concrete
Plastic
“a.
* For Plug-in Modules or ln-Wall Devices Installed, Plastic Junction
Boxes
** Line of Sight / no obstructions
Number 1
of Walls or
Obstacles 2
Please Note: Z-Wave home control networks are designed to
work properly alongside 802.11 wireless computer networks,
Bluetooth and 2.4GHz, 5.SGHz or DECT devices. Some baby
cams, wireless video devices and older cordless phones using
the 900MHz frequency range may cause interference and limit
Z-Wave functionality. Many 900MHz products have a switch to
select channel “A” or “”.B You may find that one of these channels
will cause less interference than the other.
IMPORTANT NOTE ABOUT 3-WAY CIRCUITS
The term “3-way circuit” refers to a circuit with two switches
and one load (light) like you find at the top and bottom of a
stainNay. There are many ways to physically wire a 3-way
circuit and it is important to understand how the circuit you
wish to upgrade to Z—Wave control is wired. Below is a
description of a typical 3-way circuit.
One of the ways to wire a two-switch/one-load circuit is
to route the incoming power through the first switch, then
to the second switch and then to the load. Although very
common and by no means a standard, it is the easiest to
convert to Z-Wave control. With this type of circuit, Switch
1 is replaced by the Z—Wave auxiliary switch and Switch 2
is replaced with the primary Z—Wave switch. The auxiliary
switch does not actually control the power; instead, it sends
a momentary voltage signal through the traveler wire to the
primary switch which in turn, controls the power to the load.
Typical 3-way circuit:
Black Black
Colored (NOT GREEN)
Wrong Z-Wave switch position for typical 3-way
circuit; Black
Black (Line/ Hot) (Load)
White
White (Neutral)
Correct Z-Wave switch position for typical 3-way
cig'lgcuit:
Z-Wave
Primary
Other
Z-Wave
Auxiliary
White
To change color of the switch
1. Lift the Air Gap tab at the base of the cover.
2. Push side tabs in on one side and then the other to release
cover. Lift the cover up and off.
3. Simply put the new cover onto the switch by inserting the air
gap and side tabs and snapping securly into place.
Please consult an electrician if you have trouble identifying the
type of wiring circuit you wish to convert or if you do not feel
confident in your ability to convert the circuit to Z-Wave control.
INSTALLATION
This dimmer switch may be used in new installations or to
replace an existing wall switch. It may be used by itself
for 2-way control (one switch & one load), with one 45610
Auxiliary Switch* for 3-way control (two switches & one
load) or with two 45610 Auxiliary switches for 4-way control
(three switches & one load). When used by itself for 2-way
control, please make sure that the screw terminal for the
traveler wire is insulated (Do Not Remove the tape over the
terminal if you are not using the traveler connection).
Single Switch Wiring Schematic
White (Neutral) @
Black
(Load)
Wave
Dimmer
Green (Ground)
Black (Line/ Hot)
3-Way Wiring Schematic using one 45612 and one
45610
White (Neutral)
Traveler - Colored (Not Green)
Auxiliary
Green (Ground)
Black (Line / Hot)
Black
(Load)
Z-Wave
Auxiliary
Green (Ground)
While (Neutral)
Traveler , Colored
(Not Green)
Traveler - Colored (Not Green)
. Black
(Load)
Z-Wave
ZrWave Primary
Auxlliary
Green (Ground) ‘
Black (Line / Hm)
Single, Dual and Triple Gang Boxes
The metal plate surrounding the switch assembly is a
heat sink. The maximum load rating (600W) is provided
when installed in a single gang box with the full heat sink.
Multiple 45612 dimmer switches may be installed in dual
or triple gang boxes and, if necessary, one or both sides
of the heat sink may be removed by bending it at the
score lines. There is a corresponding reduction in the
switch’s load rating when ganged. DO NOT exceed the
following loads:
Dimmer Rating Number of Dimmers HeatSink
600W One switch in a Single Gang Box Full
500W Two switches in a Double Gang Box One side
removed
400W Three switches in a Triple Gang Box Both sides
Traveler
¢ '3 ."l_ :_ ,
I. ‘l ‘—
. . .. .n “-m: . .
- ‘IDtMI' Ion-n
“t "A":
gp'rx- €®n
Ground - “'5‘ .mi'ifl..-.
o 0' 4:113“- ‘o o Q
A- _ ..
. J “ ‘ ‘
J .1 + _ -
Black Black
(Load) (HOT)
AWARNING
SHOCK HAZARD!
Turn OFF the power to the branch circuit at the circuit
breaker in your electrical service panel. Ensure power
is OFF before you install this device. All wiring connections
must be made with the POWER OFF to avoid personal
injury and/or damage to the switch.
1. Shut off power to the circuit at fuse box or 15A circuit
breaker.
2. Remove wall plate. ! Warning: Verify power is OFF to
switch box before continuing.
3. Remove the switch mounting screws.
4. Carefully remove the switch from the switch box. DO NOT
disconnect the wires.
5. There are four screw terminals on the 45612 switch; these
are marked LINE (Hot), LOAD, GROUND and TRAVELER.
The Traveler terminal is only used for 3-way or 4-way wiring
and should remain insulated if the 45612 is being installed in
a 2-way system (one switch & one load). Match these screw
terminals to the wires connected to the existing switch. (Do
Not remove the tape over the terminal if you are not using
the traveler connection).
6. Disconnect the wires from the existing switch.
7. Connect the green or bare copper ground wire to the
GROUND terminal.
8.Connect the black wire that goes to the light to the terminal
marked LOAD.
9. Connect the black wire that comes from the electrical
service panel (Hot) to the terminal marked LINE. Note: UL
specifies that the tightening torque for the screws is
14 Kgf-cm (12 lbf-in).
10. OPTIONAL for 3 or 4-way control: Connect the Traveler
wire (usually Red) to the screw terminal marked TRAVELER.
The other end of this Traveler wire connects to the
TRAVELER screw terminal on the 45610 Auxiliary Switch.
See the following section for information about wiring the
45610 Auxiliary Switch.
11. Insert Z-Wave Switch into the switch box being careful
not to pinch or crush wires.
12. Secure the switch to the box using the supplied screws.
13. Mount the wall plate.
14. Reapply power to the circuit at fuse box or circuit breaker
and test the system.
Optional for 3 or 4-Way Control:
1. The 45610 requires the following 3 wiring connections:
a. The Traveler wire. This is used to send voltage signals to
the primary Z-Wave switch. The signals tell the Z-wave switch
what action to perform.
b. Ground.
c. Neutral.
2. DO NOT connect the 45610 auxiliary switch to the home’s
black Hot (Line) wire.
Observe Important Wiring Information
Important: This switch is rated for and intended to only be
used with copper wire.
The home’s electrical wires may be attached to the screw
terminals or inserted into the holes in the back of the switch
enclosure and clamped in place by tightening the screw
terminals. Always follow the recommended wire strip lengths
when making wiring connections.
Wire strip length:
- For attachment to screw terminals: Strip insulation 5/ ” (max
14 AWG wire).
- For attachment using the enclosure’s holes: Strip insulation
5/8” (max 14 AWG wire).
You should now be able to use the rocker to manually turn On/
Off or adjust the brightness of the connected load.
Use your primary controller to include the switch in the home
control network after the switch is wired as shown in the above
diagram. It can then be added to groups and/or lighting scenes
and managed remotely to control the On/Off/Dim status of the
connected lighting.
Air Gap Switch
During normal operation, there is a small amount of power
passing through the switch to the load even when the switch
is turned off. The 45612 has an air gap switch on the lower
left side (see diagram for location) to completely disconnect
power to the load. Pull the air gap switch OUT to disconnect
the power while replacing light bulbs and push it all the way
back in for normal operation. The air gap switch must be all
the way in for the switch to function and control the lighting.
Key Features
- Remote On/Off/Brightness control via the
Z—Wave controller/network
- Manual On/Off/Brightness control with the front panel
rocker
- Compatible with 2, 3, or 4 way wiring configurations
' LED indicates switch location in a dark room
BASIC OPERATION
Remote Control
Jasco Z-Wave remotes provide control of an Individual
device, Groups of devices and Scenes. Other brands of
Z-Wave Certified remotes may not offer as much flexibility
in how you can set up your lighting control network. Please
refer to your remote control’s instructions for details on
its capabilities and instructions for adding and controlling
devices.
Manual Control
The 45612 dimmer switch allows the user to:
Turn ON/OFF and control the brightness level of the
connected lighting.
- To turn the connected lighting ON: Tap the top of the rocker.
- To turn the connected lighting OFF: Tap the bottom of the
rocker.
- To brighten the connected lighting: Press and hold the top of
the rocker; release when desired level is achieved.
- To dim the connected lighting; Press and hold the bottom
of the rocker release when desired level is achieved. Please
note: pressing and holding the rocker until the light intensity
is at the minimum setting does not turn the power OFF; you
must still tap (press & release) the bottom of the rocker to turn
the power OFF.
- When OFF, pressing and holding the bottom of the rocker
will cause the lighting to go to the minimum dim level.
Program your Light Switch (Include or exclude the switch
to/from the Z-Wave home control network.)
- Refer to the instructions for your primary controller to
access the network setup function and include or exclude
devices.
- When prompted by your primary controller, tap the top or
bottom of the rocker.
- The primary controller should indicate that the action
was successful. If the controller indicates the action was
unsuccessful, please repeat the procedure.
- Once the switch is part of the network, the same basic
procedure is used to add the switch to groups & scenes
or change advanced functions. Refer to the primary
controller’s instructions for details.
Note: After a power failure, the 45612 dimmer switch will
default to OFF.
LED Indicator
The LED will be lit when the connected lighting is OFF.
This is the factory default setting and can be changed if your
primary controller supports the node configuration function
(see Advanced Operation below)
ADVANCED OPERATION
The following Advanced Operation parameters require that
you have an advanced controller like the Jasco model 45601
LCD remote. Advanced remotes from other manufacturers
may also be able to change these settings; however, basic
remotes do not have this capability.
All 0n/All Off
Depending upon your primary controller, the 45612 switch can
be set to respond to ALL ON and ALL OFF commands in up
to four different ways. Some controllers may not be able to
change the response from its default setting. Please refer to
your controller’s instructions for information on whether or not
it supports the configuration function and if so, how to change
this setting.
1. The four possible responses are:
2. It will respond to ALL ON and the ALL OFF command
(default).
3. It will not respond to ALL ON or ALL OFF commands.
4. It will respond to the ALL OFF command but will not
respond to the ALL ON command.
5. It will respond to the ALL ON command but will not
respond to the ALL OFF command.
LED
When shipped from the factory, the LED is set to turn ON
when the connected light is turned OFF. This allows the LED
to indicate the switch’s location in a dark room. To make the
LED turn ON when the light is turned ON, change parameter
3’s value to “1 ”
- Parameter No: 3
' Length: 1 Byte
- Valid Values = 0 or 1 (default 0)
Invert Switch
If the switch is accidentally installed upside down with “On"
at the bottom and “Off” at the top, the default On/Off rocker
settings can be reversed by changing parameter 4’s value to
“1
- Parameter No: 4
- Length: 1 Byte
' Valid Values = O or 1 (default 0)
Dim Rate Adjustments
Both the number of steps (or levels) that the dimmer will
change and the timing of the steps can be modified to suit
personal preferences. The timing of the steps can be adjusted
in 10 millisecond intervals.
1. When Receiving a Z-Wave Dim Command
- Parameter 7 (number of steps or levels)
- Parameter 8 (timing of the steps)
- Length: 1 Byte
- Valid Values:
Parameter 7 (default: 1) Valid Values: 1-99
Parameter 8 (default: 3) Valid Values: 1-255
2. Manual Control Dimming (pressing the Dimmer’s rocker)
- Parameter 9 (number of steps or levels)
- Parameter to (timing of the steps)
- Length: 1 Byte
- Valid Values:
Parameter 9 (default: 1) Valid Values: 1-99
Parameter 10 (default: 3) Valid Values: 1-255
3. When Receiving an All-On orAll-Off Command
- Parameter 11 (number of steps or levels)
- Parameter 12 (timing of the steps)
- Length: 1 Byte
' Valid Values:
Parameter 11 (default: 1) Valid Values: 1-99
Parameter 12 (default: 3) Valid Values: 1-255
Ignore Start Level When Receiving Dim Commands
Please note: Every “Dim” command includes a start level
embedded in it. The 45612 can be set to ignore the start level
that is part of the dim command. Setting parameter 5 to a
value of 0 will cause the 45612 to dim or brighten from the start
level embedded in the command.
- Parameter No: 5
- Length: 1 Byte
- Valid Values = 0 or 1 (default 1)
Restoring Factory Defaults
All Configuration Parameters can all be restored to their factory
default settings by using your master controller to delete/reset the
device.
WARRANTY
JASCO Products warrants this product to be free from
manufacturing defects for a period of two years from the original
date of consumer purchase. This warranty is limited to the
repair or replacement of this product only and does not extend to
consequential or incidental damage to other products that may
be used with this product. This warranty is in lieu of all other
warranties, expressed or implied. Some states do not allow
limitations on how long an implied warranty lasts or permit the
exclusion or limitation of incidental or consequential damage, so the
above limitations may not apply to you. This warranty gives you
specific rights, and you may also have other rights which vary from
state to state. Please contact Customer Service at
800-654-8483 (option 4) between 7:30AM — 5:00PM CST or via our
website (www.jascoproducts.com) if the unit should prove defective
within the warranty period,
JASCO Products Company
Building B
10 E Memorial Rd. Oklahoma City, OK 73114
FCC
UZZZW4002
The Federal Communication Commission Radio Frequency
Interference Statement includes the following paragraph:
The equipment has been tested and found to comply with
the limits for a Class B Digital Device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment uses, generates and
can radiate radio frequency energy and, if not installed and
used in accordance with the instruction, may cause harmful
interference to radio communication. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and
receiver
- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for
help
Operation is subject to the following two conditions:
- This device may not cause interference
- This device must accept any interference, including
interference that may cause undesired operation of the
device.
Important Note: To comply with the FCC RF exposure
compliance requirements, no change to the antenna or
the device is permitted. Any change to the antenna or the
device could result in the device exceeding the RF exposure
requirements and void user’s authority to operate the device.
Compliance with IC Rules and Regulations
IC: 6924A-ZW4002
Jasco Products Company
Model: ZW4002
45743
This Class B digital device complies with Canadian ICES-003.
This device complies with Industry Canada licence-
exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause
interference, and (2) this device must accept any
interference, including interference that may cause
undesired operation of the device.
SPECIFICATIONS
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.42 MHZ.
Maximum Loads: 600W, incandescent
Range: Up to 100 feet line of sight between the Wireless
Controller and the closest Z-Wave receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For indoor use only.
Specifications subject to change without notice due to
continuing product improvement
Z-Wave is a registered US trademark of Sigma Designs
© 2012 JASCO Products Company
Distributed by Jasco Products Company LLC,
10 E Memorial Rd., Oklahoma City, Oklahoma 73114
Made in China
Hecho en China
All brand names shown are trademarks of their
respective owners.
Todas Ias marcas que aparecen aqui son marcas
registradas de sus respectivos duefios.
© 2013 Jasco Products
45743(ZW4002)
rev. 01/18/13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2013:05:30 16:56:24+08:00
Create Date                     : 2013:05:30 16:56:24+08:00
Format                          : application/pdf
Title                           : 45743 English Manual 012113.pdf
Creator                         : Jacky Koo
Document ID                     : uuid:23d12c2d-8b27-436f-aded-3508dcf0fd69
Instance ID                     : uuid:5a39c144-5825-4d18-b672-e3c752d1376b
Page Count                      : 25
Author                          : Jacky Koo
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U2ZZW4002

Navigation menu