ShenZhen Jumper Medical Equipment JPD100SP Fetal Doppler User Manual
ShenZhen Jumper Medical Equipment Co.,Ltd Fetal Doppler Users Manual
User manual
2.4 SAFETY TERMS AND CONDITIONS User Manual The signal words shown below, left, identify the potential hazard categories. The definition of each category is as follows: Fetal Doppler DANGER: This alert identifies hazards that will cause serious personal injury or death. Model:JPD-100S+ WARNING: This alert identifies hazards that may cause serious personal injury or death. Manual Ver.: 1.1 Issuing Date: May 2017 Thank you for purchasing the Fetal Doppler JPD-100S+ made by Jumper Medical Before using the product, read this manual carefully and operate the product as specified in this manual. SECTION 1: INTRODUCTION 1.1 PACKING LIST Main unit X 1; USB charging cable X 1; Coupling agent X 1; User manual X 1. 1.2 PRODUCT DESCRIPTION The product is mainly used to detect the sound of the fetal heartbeat (SFH). In accordance with classification criteria in Annex IX on “Medical Device Directive 93/42/EEC”, the product is class IIa based on rule 10, “Devices for Direct Diagnosis or Detection on physiological process”. 1.3 OPERATING PRINCIPLE Based on the Doppler's principle, a 2.0MHz ultrasonic probe is used to capture fetal heart signals from the belly of a pregnant woman. After signal processing of the backend circuit, the fetal heart signals are output to the headset socket, and audio signals are wirelessly sent by using the built-in Bluetooth module. A smartphone that has connected to the product receives the data and calculates and displays fetal heart rate information by using specified mobile phone software. SECTION 2: SAFETY GUIDANCE 2.1 INDICATIONS FOR USE The product is normally applied to fetus above 20 weeks growth, difference in pregnant mater. ● Listen to SFH: Operator can listen to the sound of fetal heartbeat from the headset. ● Audio record: The sound of fetal heartbeat can be recorded by a smartphone which is connected with the product. CAUTION: It should not be used in life supporting or life sustaining applications. 2.2 CONTRAINDICATIONS FOR USE Normally none, as a particular case, please consult your doctor. 2.3 NOTE FOR HOME USE Please consult your doctor. CAUTION: This alert identifies hazards that may cause minor personal injury, product damage, or property damage. 2.5 SAFETY ALERT DESCRIPTIONS The following is a list of product safety alerts that appear in this section and throughout this manual. You must read, understand, and pay heed to these safety alerts before attempting to operate the product. When disinfecting the case, use a non-oxidizing disinfectant, such as ammonium salts or glutaraldehyde based cleaning solution, to avoid damage to the metal connectors. CAUTION: Environment of use The product is designed for indoor use. Operator must confirm that the environment of use meets the required operating environmental specifications before using. CAUTION: Cold Environments If the product is stored in an environment with a temperature below the operating temperature, the unit should be allowed to warm up to the needed operating temperature before using. 2.6 SYMBOL DESCRIPTIONS 3.1 The following symbols may appear in this manual, on the product, or on its accessories. Some of the symbols represent standards and compliances associated with the product and its use. 3.1.1 Power on/off DANGER: Fire and Explosion Hazard Do not operate the Product in the presence of flammable gases to avoid possible explosion or fire hazard. Consult instructions for use of the product and/or its accessories. WARNING: Use only Approved Equipment Do not use batteries, gel, cables, or optional equipment other than those approved by Jumper Medical Equipment Co.,Ltd which may cause the product to function improperly during a rescue. Authorized Representative in the European Community. CE Mark: The Product system conforms to essential requirements of the Medical Device Directive 93/42/EEC. Warning Information. Date of manufacture. WARNING: Adjacent and/or Stacked Equipment The Product should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, the Product should be observed to verify normal operation in the configuration in which it will be used. Manufacturer information. type BF applied part CAUTION:Temperature/Humidity/Pressure xtremes Exposing the Product to extreme environmental conditions outside of its operating parameters may compromise the ability of the Product to function properly. CAUTION: Battery Disposal Recycle or dispose of the battery in accordance with all federal, state and local laws. To avoid fire and explosion hazard, do not burn or incinerate the battery. CAUTION: Possible Radio Frequency (RF) Susceptibility RF susceptibility from cellular phones, CB radios and FM 2-way radio may cause interference with the product. Do not operate wireless radiotelephones in the vicinity of the Product – turn power OFF to the radiotelephone and other like equipment near the Product. CAUTION: Systems Statement Equipment connected to the product must be certified to the respective IEC Standards ( IEC 60601-1 for medical equipment). CAUTION: Case Cleaning Solutions PRODUCT Power on: Press and hold this button for about 2s and release this button, the power indicator is on, and the instrument is powered on. Power off: When the instrument is in the power-on state, press and hold this button for about 2s, the power indicator goes out, and the instrument is powered off. 3.1.2 USB charging jack Charging Requirements 1. Before using the instrument for the first time, if the power indicator blinks or the instrument is automatically powered off due to a low battery level after the instrument is powered on, charge the instrument. 2. Charge the instrument by using a mobile phone charger or a computer USB jack. 3. Charge the instrument for about 2 to 4 hours. 3.4 DESCRIPTIONS OF THE INDICATOR STATES Indicator type Specifies serial number of the Product Ipx4 Waterproofing grade 4 It indicates that the equipment should be sent to the special agencies according to local regulation for separate collection after its useful life. SECTION 3: USING THE PRODUCT This section provides the description for operation. Indicator state Steady green Batch code The environmental protection use period is 5 years. STRUCTURE Power indicator/Fetal heart signal indicator Steady orange Blink orange evenly Blink with the fetal heart signal frequency Instrument working state The instrument is powered on/fully charged. The instrument is charging. The instrument is in a low voltage state. The instrument is in the working state, and the ultrasonic probe captures a fetal heart signal. 3.5 USING PRODUCT TO DETECT Locate the position of the fetus by hand touching, firstly to find out the best direction to the fetal heart. Place the faceplate of probe at the best position for detecting fetal heartbeat. Adjust the transducer to obtain an optimum audio signal ideally by angling the transducer around. Generally, the site of heart of fetus is 1/3 below of navel line at its earlier stage, it then moves upward with increasing of gestational period, and the site of heart of fetus will be a little deviation to left or right with different fetus. Pls. make sure that the surface of the probe should be contacted fully with the skin. After the sound become clear, it is the proper functioning. If no coupling gel, water can be used. a solution of soap and wipe dry with a clean cloth immediately.Wipe the transducer body with soft cloth to remove any remaining coupling gel .Clean with soap only. Gestation Antepartum Parturition 3.6 CONNECTING THE INSTRUMENT TO THE SMARTPHONE VIA BLUETOOTH Software Downloading: 1. Download and install the mobile phone APP software "AngelSounds" by scanning the QR code on the packing box or searching for the APP in application stores such as APP Store/Google Market. 2. This software supports iOS 7.0 and later versions, and Android 4.3 and later versions. In addition, hardware of the smartphone needs to support Bluetooth 4.0. Bluetooth connection: 1. Start AngelSounds" on the smartphone, and enable the Bluetooth function of the smartphone to search for a Bluetooth device, find the Bluetooth name of the Fetal doppler, and pair with the instrument. Software Usage: Detailed see software operation manual. SECTION 4: MAINTENANCE & CLEANING AND DISINFECTION 4.1 MAINTENANCE 4.1.1 The transducer acoustic surface is frangible and must be handle with care .Gel must be wiped off from the transducer after use. These precautions will prolong the life of the unit. 4.1.2 The user must check that the equipment does not have visible evidence of damage that may affect patient safety or product’s capability before use .The recommended inspection interval is once per month or less. If damage is evident, replacement is recommended before use. 4.1.3 To ensure the product is always functional when required, the following maintenance shall be performed. ● Visual Inspection ● Cleaning the product and its accessories ● Check the battery fuel gauge ● Testing product performance ● If the product is not been used for a long time, charge the product once every three months. ● The product requires no calibration. 4.2 CLEANING PRODUCT AND ACCESSORIES The following cleaning products may be used to clean the exterior surfaces of the product. Isopropyl alcohol (70% solution in water) Mild soap and water Sodium hypochlorite (chlorine bleach) (3% solution in water). Quaternary ammonium compounds (such as Lysol) (10% solution in water). WARNING: Do not use abrasive cleaners or strong solvents such as acetone or acetone-based cleaners. WARNING: Do not use mixing disinfecting solutions (such as bleach and ammonia) as hazardous gases may result. WARNING:Do not use acid, alkaline, or corrosive detergent. WARNING: Do not clean electrical contacts or connectors with bleach. 4.3 CLEANING INSTRUCTIONS 1. Before cleaning the product, turn off the product. 2. Before cleaning, remove all adherent soil (tissue, fluids, etc.) and wipe thoroughly with a cloth dampened with water before applying the cleaning solution. 3. When cleaning, do not immerse. Keep the exterior surface of the device clean and free of dust and dirt, clean exterior surface of the unit with a dry, soft cloth .if necessary, clean it with a soft cloth soaked in CAUTION: To prevent damage to the product, do not clean any part of the Product or Accessories with phenolic compounds. Do not use abrasive or flammable cleaning agents. Do not steam, autoclave, or gas-sterilize the Product or accessories. CAUTION: Cleaning liquids: do not submerge the product in liquids or pour cleaning liquids over, into or onto the product. 4.4 DISINFECTION Cleaning the unit surface and the transducer as the above mentioned, then wipe the surface of transducer with 75% ethanol or alcohol, clean the transducer surface with a dry, soft cloth. WARNING: Don’t use low temperature steam sterilization or other way to sterilize. WARNING:Don’t use high temperature sterilizing process. Power-on failure No sound Fetal heart cannot be found Low sensitivity A 1.2 Electromagnetic Immunity Charge the instrument Increase the volume Charge the instrument Increase the volume Coat the coupling agent or water The Fetal Doppler is intended for use in the IEC Compliance Electromagn Immunity 60601 level etic Adjust the probe location Coat a proper amount of coupling agent test test environment level guidance Fetal Doppler needs special precautions regarding EMC and needs to be installed and put into service according to the EMC customer or the user of the Fetal Doppler should assure that it is used in such an environment. Floors should be wood, Electrostatic ±6 kV ±6 kV ceramic tile. discharge contact contact If floors are (ESD) ±8 kV ±8 kV air covered with IEC air synthetic material, the 61000-4-2 relative information provided for in the humidity ACCOMPANYING DOCUMENTS. should be at least 30 %. CAUTION: Power Portable and mobile RF communications frequency equipment can affect Fetal Doppler. CAUTION: The Fetal Doppler should not be used adjacent to or stacked with other equipment. A1.1 Electromagnetic Emissions The Fetal Doppler is intended for use in the electromagnetic environment specified below. The magnetic Power fields frequency should be at levels (50/60 Hz) magnetic field 3 A/m characteristic 3 A/m of lEC a typical 61000-4-8 location in a typical customer or the user of the Fetal heart monitor should commercial assure that it is used in such an environment. Emissions test or hospital Compliance environment The Fetal Doppler uses RF RF energy only for its internal A 1.3 Electromagnetic Immunity (not life-supporting) emissions Group 1 function. Therefore, its RF CISPR 11 emissions are very low and The Fetal Doppler is intended for use in the are not likely to cause any interference in nearby electronic equipment. The Fetal Doppler is suitable for use in all establishments, RF Class B including domestic emissions establishments and those CISPR 11 directly connected to the public low-voltage power supply network that supplies buildings used for domestic Troubleshooting electromagnetic environment specified below. The concrete or CAUTION: 5.1 SPECIFICATIONS NOTE: The following specifications are subject to change and are only noted as a point of reference. 5.2 Troubleshooting Possible Symptom cause Troubleshooting EMC Information SECTION 5: SPECIFICATIONS & TROUBLESHOOTING This section presents the specifications and safety standards of the Product. Technical Specifications Acoustic working frequency: 2.0MHz±5% Overall sensitivity : 96 dB Overall sensitivity at the distances 50,75,100 and 200 mm from the face of the probe:95 dB、98 dB、96 dB、97 dB Doppler frequency and target velocity, used for the determination of b)(given to two significant figures):300Hz,12cm/s Spatial-peak temporal-peak acoustic pressure: 20.1kPa Effective area of the ultrasonic transducer active element: 4.8±0.3cm2 Output power: 7.9mW Power working mode: Built-in rechargeable lithium battery 7.4V Working mode: Continuous working (greater than 6 hours) Battery capacity: 600mAh Charging limit: Input 5V 1A Safety type: Internally powered equipment, type BF applied part Operating mode: continuous operation Electromagnetic compatibility: I group, B class Waterproofing grade: IPX4 Net weight of the main product: 99.5g±5g Dimension (diameter × thickness): 80mm×50mm Description of the acoustic coupling medium for normal use, together with its characteristic acoustic impedance: 1.7×105g/cm2.s, fading 0.02dB/mm The acoustic output parameter meets the provision freedom from publication in IEC61157 Requirement for the declaration of the acoustic output of medical diagnostic ultrasonic equipment: P_<1MPa; Iob<20mW/cm2; Ispta<100mW/cm2 Product service life: 5 years Production date: See the label Operation conditions: Temperature: 5C to 40C; Humidity:≤80%RH; non-condensing Atmospheric pressure:70kpa to 106kpa Transportation & Storage conditions: Temperature: -20C to 55C; Humidity:10%RH – 93%RH; non-condensing Atmospheric pressure:50kpa to 106kpa; indoor ventilated place that has no corrosive gas Possible cause Low battery level Low volume Insufficient power Low volume The coupling agent is not coated Incorrect probe location The coupling agent is not coated Symptom purposes. electromagnetic environment specified below. The customer or the user of the Fetal Doppler should assure that it is used in such an environment. IEC Complian Immunity 60601 ce Electromagnetic test test level environment – Level guidance Portable and mobile RF communication s equipment should be used no closer to any part of the Fetal For transmitters rated at a maximum output power not listed - English: Doppler above, the recommended separation distance d in metres This device complies with Industry Canada licence-exempt including (m) can be estimated using the equation applicable to the RSS standard(s). cables, than the frequency of the transmitter, where P is the maximum Operation is subject to the following two conditions: (1) This recommended output power rating of the transmitter in watts (W) device may not cause interference, and (2) This device mu according to the transmitter manufacturer. st accept any interference, including interference that may c NOTE 1 At 80 MHz and 800 MHz, the separation distance ause undesired operation of the device. separation distance calculated from the equation applicable to the frequency of Radiated 3 V/m 3 V/m the transmitter. RF 80 MHz Recommended IEC to 2,5 separation 61000-4-3 GHz distance NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Fetal Doppler is used exceeds the a. Where P is applicable RF compliance level above, the Fetal Doppler the maximum should be observed to verify normal operation. If abnormal output power performance is observed, additional measures may be rating of the necessary, such as re-orienting or relocating the Fetal transmitter in Doppler. watts (W) b Over the frequency range 150 kHz to 80 MHz, field according to the strengths should be less than 3 V/m. transmitter A 1.4 Recommended Separation Distances manufacturer Recommended separation distances between portable and and d is the mobile RF communications equipment and the Fetal recommended Doppler. separation The Fetal Doppler is intended for use in an distance in electromagnetic environment in which radiated RF metres (m). disturbances are controlled. The customer or the user of Field strengths the Fetal Doppler can help prevent electromagnetic from fixed RF interference by maintaining a minimum distance between transmitters, as portable and mobile RF communications equipment determined by (transmitters) and the Fetal Doppler as recommended an below, according to the maximum output power of the electromagnetic communications equipment. of transmitter output (m) compliance power level in each 150 kHz to 80 MHz to 800 MHz to of frequency 80 MHz 800 MHz 2.5 GHz transmitter range. symbol: (1) l'appareil ne doit pas produire de brouillage, et This device complies with part 15 of the FCC Rules. (2) l'utilisateur de l'appareil doit accepter tout brouillage Operation is subject to the following two conditions: (1) This radioélectrique subi, même si le brouillage est susceptible device may not cause harmful interference, and (2) this d'en compromettre le fonctionnement. device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide SECTION 7: CONTACT INFORMATION 7.1 Manufacturer Shenzhen Jumper Medical Equipment Co., Ltd Address: D Building, No. 71, Xintian Road, Fuyong Street, Baoan,Shenzhen,Guangdong,China 7.2 Authorized European Representative used in accordance with the instructions, may cause harmful interference to radio communications. However, interference to radio or television reception, which can be maximum following L'exploitation est autorisée aux deux conditions suivantes: SECTION 6: FCC/ISED CAUTION particular installation. If this equipment does cause harmful than the marked with the Canada applicables aux appareils radio exempts de licence. there is no guarantee that interference will not occur in a Rated equipment Le présent appareil est conforme aux CNR d'Industrie reflection from structures, objects and people. can radiate radio frequency energy and, if not installed and should be less the vicinity of - French: Electromagnetic propagation is affected by absorption and residential installation. This equipment generates uses and Separation distance according to frequency may occur in NOTE 2 These guidelines may not apply in all situations. reasonable protection against harmful interference in a site survey, b. Interference for the higher frequency range applies. determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 0.01 0.12 0.12 0.23 The device has been evaluated to meet general RF exposu 0.1 0.38 0.38 0.73 re requirement. The device can be used in portable 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 exposure condition without restriction. Shenzhen Jumper Medical Equipment Co., Ltd Address: D Building, No. 71, Xintian Road, Fuyong Street, Baoan,Shenzhen,Guangdong,China Tel: +86-755-26696279/26692192 Fax: +86-755-26852025 Website: www.jumper-medical.com E-mail: info@jumper-medical.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : ls Create Date : 2017:09:29 08:32:46+08:00 Modify Date : 2017:09:29 08:32:46+08:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : PScript5.dll Version 5.2.2 Format : application/pdf Title : <4D6963726F736F667420576F7264202D20313030532BD3A2CEC4CBB5C3F7CAE95F34D5DBD2B3D4D932D5DBD2B35F383067CDADB0E5D6BD5FB5A5BADAD3A15FB8A3D3C05F3033323131375FC2FCC1AA> Creator : ls Producer : Acrobat Distiller 10.1.0 (Windows) Document ID : uuid:2ca30379-3a77-4c41-a4d8-5a419ab1b838 Instance ID : uuid:76659528-dcad-4c52-815f-6b3b39da6292 Page Count : 3EXIF Metadata provided by EXIF.tools