ShenZhen Jumper Medical Equipment JPD500F pulse oximeter User Manual 141212001GZU 001
ShenZhen Jumper Medical Equipment Co.,Ltd pulse oximeter 141212001GZU 001
141212001GZU-001_User manual
Pulse Oximeter JPD-500F FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may not cause harmful interference. (2) this device must accept any interference received,including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the ser is encouraged to try to correct the interference by one or more of the following measures: ● Reorient or relocate the receiving antenna. ● Increase the separation between the equipment and receiver. ●Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ●Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Precautions Do not attempt to maintain the Oximeter unless you are professional engineers. Only professionals with maintenance qualification are allowed to perform interior maintenance as necessary. Periodically change the contact position between the Oximeter probe and the finger for a measurement that lasts a long time. Adjust the position of the probe before the measurement lasts two hours, and check the integrity of skin, the blood circulation condition of the finger as well as the position of the finger. This product is not applicable to the examination of newborn babies. Seek for medical care in time if the measured value goes beyond the normal range while you are sure that the instrument does not malfunction. Do not directly expose your eyes to light-emitting components of the Oximeter, as that could cause harm to your eyes. For details about clinical limitations and contraindications, please carefully consult relevant medical literatures. The following factors may cause disturbance to or affect the accuracy of ◆ ◆ such as high-frequency electric knives and CT apparatuses. The Perfusion Index (PI) usually reflects the limb perfusion status of an examined The probe of the Oximeter is placed on the same body part or limb as patient, and shows the detection precision of the instrument as well; that is, with blood pressure cuff arterial duct or intravenous injection. examination can still be performed even in the low or weak perfusion condition.The The user suffers from hypotension, severe vascular atrophy, severe ◆ The user is in sudden cardiac arrest or shock state. ◆ The finger with nail polish or a fake fingernail may cause wrong readings of pulse oxygen saturation. Working Principles, Expected Usage, and Applicable Scope Based on full digital technology, the Finger Pulse Oximeter non-invasively measures the actual content (oxygen saturation) of oxyhemoglobin (HbO2) in arterial blood using the optical transmittance method. Warnings The Finger Pulse Oximeter measures the blood oxygen saturation and pulse rate of Warning: Do not use the Oximeter in an environment with any inflammable gases, inflammable anesthetic, or other inflammable substances. Warning: Do not attempt to charge any common dry battery, as that could cause leakage, fire disaster, or even explosion. Dispose of exhausted batteries in accordance with environment protection regulations. Warning: Do not use the Oximeter in an MRI or CT environment. Warning:Do not operate the Oximeter when it is damp with overflow or water a human body via finger artery. It is applicable to a wide range of fields, such as families, hospitals (including operation rooms of the departments of internal medicine and surgery, the department of anesthesiology, the department of paediatrics, and intensive care rooms), oxygen bars, social medical care institutions, and sports & health. Use this instrument for measurement before or after sports. You are not advised to use this instrument during sports activities. It is applicable to patients 15 to 60 years old. Do not use it for continuous care for patients. vapor condensation. Avoid moving the Oximeter from an excessively-cold environment to a high-temperature moist environment. Symbol Conventions Schematic Diagram of Display The following figure shows the information display on the OLED screen of the Oximeter in normal detection state: Symbol Description BF-type application part Caution: Please see this manual. %SpO2 Symbol of oxygen saturation bpmPR Symbol of pulse rate Bluetooth symbol When end users abandon this product, they must send the product to the collection place for recycling. Overview Symbol of oxygen saturation Measured value of oxygen saturation Bar graph Plethysmogram Measured value of Pulse rate PI Symbol of pulse rate Battery power indication/Bluetooth symbol (alternately displayed) Power-On Key/Functional Key Operations After powering on the Oximeter, hold the power-on key/functional key for about Oxygen saturation is the percentage of oxyhemoglobin (HbO2) that is combined one second. The Oximeter shows a parameter setting interface. Press or hold the with oxygen against all combinable hemoglobin (Hb). It is an important physiological power-on/functional key to perform corresponding operations. Hold it to set an parameter involved in respiration and circulation. The oxygen saturation of arterial item, or press it to switch an option or switch the display mode. Press means no blood in a normal human body is 98%. Oxygen saturation is an important indicator more than 0.5 seconds, while Hold means more than 0.5 seconds. of the oxygen condition in the human body. In general, the normal values of oxygen saturation shall not be lower than 94%. If the measured value of oxygen saturation is lower than 94%, an insufficient supply of oxygen is considered. examination: The pulse rate is the number of pulse beats per minute. Normally, the pulse rate is ◆ consistent with the heart rate. In general, the pulse rate of every people is 60 to 90 This product is used in an environment involving high-frequency devices, PI of a normal human body is 3% or greater. anemia, or low oxygen. beats per minute. Alert Sound Setting Hold the power-on key/functional key while the Oximeter is in powered-on state. Parameter setting interface 1 is displayed, as shown in the following figure. Move "*" to the corresponding option, and hold the functional key to set Alm to on and set Beep to off. When Alm is set to on and the measured values of the blood oxygen saturation and pulse rate go beyond the upper limit or lower limit, the Continuously press the functional Parameter Oximeter gives off an alert sound. When Alm is set to off and the measured values key in the monitoring process. The Oxygen saturation go beyond the limit, the Oximeter will not give any alert sound. When Beep is set to monitored data and the display on, a tick will be heard along with pulse beats during pulse rate measurement. mode will be cyclically displayed on When Beep is set to off, no sound will be output along with pulse beats during the OLED screen in two different pulse rate measurement. While the "*" symbol stays on the Restore option, hold ways (large fonts and plethysmogram) the functional key to restore factory settings. and four directions, as shown in the Pulse rate Alert condition following figure. Brightness Setting Replace the batteries when On parameter interface 1, press the functional key to select the Brightness option the battery capacity is and then hold the functional key to set the brightness to a value ranging from 1 to 5. insufficient and the symbol The greater the value, the greater the brightness of the screen. Cleaning Alert Range Setting On parameter interface 2, press the functional key to switch between options. On this interface, you can set the upper limit and lower limit of SpO2 Alm and PR Alm. While the "*" symbol stays on the +/- option, hold the functional key to set the 7. flickers on the screen. Power off the instrument and remove the batteries before cleaning. Ensure that the appearance of the instrument is neat, dust-free, and dirt-free. Clean the outer surface of the instrument (including the OLED screen) using 75% medical alcohol and a piece of dry soft cloth. Caution: Avoid liquid flowing into the instrument during cleaning. option to + or -. In + mode, select the corresponding option and hold the functional Caution: Do not immerse any part of the instrument into any liquid. key to increment the upper or lower limit; in - mode, hold the functional key to Disinfection decrement the upper or lower limit. Move "*" to the Exit option, and hold the Before measurement with the instrument, wipe the rubber finger pad using a piece functional key to return to the monitoring interface. of dry soft cloth dipped with 75% medical alcohol. Clean the finger to be measured Technical parameters Parameter Oxygen saturation Display range Pulse rate Oxygen saturation Resolution Pulse rate Oxygen Measurement saturation precision Pulse rate Oxygen saturation Alert range Pulse rate using the medical alcohol for disinfection purposes before and after use. Maintenance Remove the batteries from the battery slot and properly store them if you do Alert error Store the Oximeter between 14 and 122°F (–10 to +50°C) and at humidity Oxygen saturation Pulse rate not plan to use the Oximeter for a long period of time. Value Upper limit: 100 Lower limit: 94 Upper limit: 130 Lower limit: 50 When the alert switch is on and the actual measured value goes beyond the preset alert parameter range, the Oximeter gives an alert sound. PI Weak PI Value 35% to 100% 25 bpm to 250 bpm 1% 1 bpm ±2% (70% to 100%) No requirement (≤ 69%) ±2 bpm Upper limit: 50% to 100% Lower limit: 50% to 100% Upper limit: 25 bpm to 250 bpm Lower limit: 25 bpm to 250 bpm ± 1% of the preset value The greater of ±10% of the preset value and ±5 bpm Min. 0.2% levels no greater than 93%. Safety Type Periodically check the Oximeter for damage. Anti-electric-shock type: internal power supply device Avoid using the Oximeter in an environment with inflammable gases or using it Anti-electric-shock degree: BF-type application part Switch on the power supply of the pulse Oximeter in an environment where the temperature or humidity is excessively high or Running mode: continuous working Stick one finger completely into the rubber pad cavity of the Oximeter, keep the low. Waterproof grade: IP22 Operation Guide fingernail surface upward, and release the clip. Then press the power key to power on the Oximeter. If you do not yet completely insert your finger into the cavity, the measurement result may be inaccurate. Dimensions: 62.0 mm (Width) × 37.0 mm (Depth) × 32.0 mm (Height) 2. Peak wavelength range of the light emitted from the probe: red light 660 nm ± Weight: 42.5 g (including the height of the two AAA dry batteries) 3; infrared light 905 nm ± 5. 3. The Oximeter will automatically shut down 10 seconds later after your finger leaves away. Connecting the Instrument to a Mobile Phone via Bluetooth Note: For details on specific operations, see software operation instructions for the mobile phone. About the Display Packaged products should be stored in well-ventilated rooms without corrosive gas and with an ambient temperature of –10 to +50°C, a relative humidity lower than 93% (without condensation), and an atmospheric pressure of 50–106 kPa. 1. stable, read the measured values of oxygen saturation and the pulse rate on the screen. Storage and Transportation an appropriate calibration apparatus. Technical Specifications Do not vibrate your finger during measurement. Preferably, ensure that your body does not move. After the readings become Check the accuracy of the oxygen saturation and pulse rate readings by using 4. 5. Wellkang Ltd Suite B, 29Harley Street, LONDON, W1G9QR,U.K. Maximum optical output power of the probe: 1.2 mW for infrared light (905 Shenzhen Jumper Medical Equipment Co., Ltd nm). Building D, No. 71, Xintian Road, Fuyong Street, Baoan,Shenzhen, Guangdong,P.R. China, P.R.518103 E-mail: info@jumper-medical.com Tel: +86-755-26692192,26696279 Web:www.jumper-medical.com Bluetooth module: 4.0 (single-mode) Normal working condition Working Temperature 5°C to 40°C (41°F to 104°F) Relative Humidity 15% to 80%, non-condensing Atmospheric Pressure 70 kPa to 106 kPa Rated Voltage DC 3.0 V 6. Default values and conditions of alert
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : ded5be06-ce16-11e4-0000-c91fff1b994f Producer : GPL Ghostscript 8.70 Keywords : () Modify Date : 2015:03:16 17:03:51+08:00 Create Date : 2015:03:16 17:03:51+08:00 Creator Tool : \376\377\000P\000D\000F\000C\000r\000e\000a\000t\000o\000r\000 \000V\000e\000r\000s\000i\000o\000n\000 \0000\000.\0009\000.\0009 Document ID : ded5be06-ce16-11e4-0000-c91fff1b994f Format : application/pdf Title : \376\377\0001\0004\0001\0002\0001\0002\0000\0000\0001\000G\000Z\000U\000-\0000\0000\0001\000_\000U\000s\000e\000r\000 \000m\000a\000n\000u\000a\000l Creator : \376\377\000j\000o\000h\000n\000.\000m\000e\000n\000g Description : () Author : john.meng Subject :EXIF Metadata provided by EXIF.tools