ShenZhen Jumper Medical Equipment JPDES100 Mini TENS Therapy Device User Manual

ShenZhen Jumper Medical Equipment Co.,Ltd Mini TENS Therapy Device Users Manual

Users Manual

User ManualMini TENS Therapy DeviceModel: JPD-ES100Please read the User Manual carefully before using the productPreparation date: 2017-09 Version: A/0Regulatory Conformance (RED)Hereby, Shenzhen Jumper Medical Equipment Co., Ltd declares that theradio equipment type JPD-ES100 is in compliance with Directive2014/53/EU.The full text of the EU declaration of conformity is available at thefollowing website:www.jumper-medical.comRF Exposure Information and Statement :This equipment complies with FCC RF radiation exposure limits set forthfor an uncontrolled environment.This device complies with part 15 of the FCC rules Operation is subjectto the following two conditions: (1) this device may not cause harmfulinterference, and (2) this device must accept any interference received,including interference that may cause undesired operation.NOTE: The manufacturer is not responsible for any radioor TV interference caused by unauthorized modifications to thisequipment. Such modifications could void the user’s authority to operatethe equipment.NOTE: This equipment has been tested and found to comply with thelimits for a Class B digital device, pursuant to part 15 of the FCCRules. These limits are designed to provide reasonable protectionagainst harmful interference in a residential installation. This equipmentgenerates uses and can radiate radio frequency energy and, if notinstalled and used in accordance with the instructions, may causeharmful interference to radio communications. However, there is noguarantee that interference will not occur in a particular installation. Ifthis equipment does cause harmful interference to radio or televisionreception, which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or moreof the following measures:- Reorient or relocate the receiving antenna.- Increase the separation between the equipment and receiver.-Connect the equipment into an outlet on a circuit different from that towhich the receiver is connected.-Consult the dealer or an experienced radio/TV technician for help- This device and its antenna(s) must not be co-located or operating inconjunction with any other antenna or transmitter.Product AppearanceFig.1: Product AppearanceHost:Fig. 2: Front of HostFig. 3: Rear of HostAccessories:1Adhesive electrode pad (φ60mm and φ90mm, two each)②USB cablePackage Content:Mini TENS Therapy Device ×1 Small electrode pad ×2Big electrode pad ×2 USB cable ×1User Manual ×1Product Introduction:Mini TENS Therapy Device can concentrate and diffuse the powerspectrum energy transiently according to certain modulationcharacteristics to simulate the actual feeling of human back pounding,beating, massaging, manipulation, acupuncture and cupping realistically.Frequent planned use of Mini TENS Therapy Device on the meridianpoint can play the treatment role and the helping role to alleviate thepains. After or during work, you can also use the Mini TENS TherapyDevice to massage for ease of body and mind.Product Structure and Composition:The product is comprised of the TENS Therapy Device host, connectingcable, self-adhesive electrode pad and USB cable.Intended Use:It is intended use for low-frequency electrical pulse treatment at thehuman acupuncture point.Range of Application:Applicable to aided treatment of back pain, nerve palsy, muscularsoreness and other pains and Bi syndromesProduct Features1. It has 5 treatment modes, switchable on the Mini TENS TherapyDevice.2. It is powered by lithium battery, requiring no battery replacement,convenient in charging.3. It can adjust the treatment strength at any time.4. It will give an alarm when electrode pad fall-off, and in that case, thetreatment will be paused automatically.5. It will power off automatically when no-operation for 5 consecutiveminutes, so it is more energy-saving.6. It is beautiful and small in the appearance, light-weight and portable.7. It has low power alarm to remind you of charging timely.8. It can be used by connecting with APP, easy to operate.APP Download and InstallationEquipment requirement: Mobile phones ofVersion IOS 7 and above and of VersionAndroid 4.3 and above. iPhone and Androidusers may scan the following QR code todownload and install the JUMPER Health.Bluetooth Paired Connection①Press the key for about 1s to boot (the buzzer will produce one longbeep, and the green light will be on);②Click the installed APP to enter the homepage of the program forConnecting cableKey for strengthdecreaseOn/off keyIndicator lightKey for strengthincreaseElectrode padUSBHost 2Host 1Magneticbuckle
user registration and login.③Enter the main interface of the program, and click "Measure"below the interface to select the "TENS Therapy" module. You will beprompted to initiate the Bluetooth function of your phone.④Search the Bluetooth to select "JPD-ES100 XXXXXX" for pairedconnection. Upon successful connection, the TENS Therapy Device willproduce a beep. If the green indicator light is flashing slowly, it meansthat it is waiting for operation.Install the TENS Therapy Device and connect it to the treatmentsite:Tear the electrode pad transparent plastic bag to take out two electrodepads. Fasten the electrode pad buckle with the magnetic buckle of MiniTENS Therapy Device, remove the electrode pad protective film, pastethe adhesive surface on the treatment site, e.g. cervical vertebra, andkeep the electrode pad in tight contact with the skin; after use, pasteback the protective film for later use.Select the treatment time on the APP interface, click "Start", select thetreatment mode, and slowly increase the treatment strength to theacceptable degree. If you click "Pause", the time and treatment strengthcannot be set. You can adjust the treatment mode during treatment.Selection of treatment modeThe following five treatment modes are optional on the interface.Prompt:1. You can press the "+/-" key on the host to adjust the treatmentstrength, with short press of "+" to increase one strength and with shortpress of "-" to decrease one strength. The strength is Level 0~15 (twoshort beeps when the energy is the strongest or the weakest);2. The setting range of treatment time is 1~30min, and the default is15min. At the end of treatment, Mini TENS Therapy Device will stoptreatment automatically and power off. If you want to end the treatmentin advance, you can press the on-off key to power off.Attentions:1. When treatment, in case of any discomfort, please stop using theproduct immediately.2. When treatment, the adhesive surface of electrode pad shall be ingood contact with the skin to avoid sense of piercing pain caused byloose contact.3. There will be slight sense of tingling at the treatment site during thetreatment, which is resulting from coupling of instrument output currentand human body, a normal circumstance.4. The user receiving the treatment for the first time might developlowered resistance due to the tension, so the current intensity shall notbe too high. It is suggested to increase the intensity slowly from 0 to 15,rather than too high at one time. The intensity shall be adjusted to thedegree acceptable by the user.5. If you switch the treatment mode during treatment, the intensity willfall to zero automatically, and you should adjust the intensity again.6. Mini TENS Therapy Device cannot operate during charging. If youwant to use it, please disconnect the charger.Charging:When the indicator light of Mini TENS Therapy Device is flashing inorange color with three short beeps, it means low power and it should becharged in a timely manner. When charging, connect one end of USBcable to the Micro-USB of Mini TENS Therapy Device correctly, andconnect the other end of USB to the socket of charger for charging (youcan use mobile phone charger or computer USB socket for charging).During charging, the indicator light will be normally on in orange color,and after fully charged, the indicator light will be normally on in greencolor.Note: The charger must pass the safety certification, consistent with theelectrical safety standards. The specification of charger must meet thevoltage of DC 5V and the output current of 500mA or above.Indicator light color status:Indicator lightStatusNormally on in green colorPower-on or fully chargedFlashing in green colorNormal working statusFlashing in orange colorLow powerNormally on in orange colorChargingBeeper sound pulse prompt:BeepStatusA long beepPower-on or power-offA short beepMode switch or strengthadjustmentTwo short beepsultimate strength prompt3 short beepsLow batteryCleaningCleaning of host: Dip soft cloth in a small amount of neutral detergent towipe the host and the connecting cable. Never allow the liquid topenetrate into the Instrument. Do not use gasoline or volatile liquid forcleaning.Cleaning of electrode pad: Wipe the dirt on the electrode pad with wetcloth, or rinse with clean water. Dry in the air, and it can be usedrepeatedly for about 30 times.ContraindicationPatients with skin disease, malignant tumor, allergic to electrode pad orimplanted with cardiac pacemaker or other apparatuses shall not usethe product. For other contraindications, please consult the doctor.TroubleshootingFaultsPossible reasonTroubleshootingUnable to bootExtremely low power●ChargeSense of piercingpain whentreatmentLoose adhesivenessof electrode pad●Paste theelectrode pad again●Replace theelectrode padElectrode padfall-off● Skin sweat●Ineffectiveelectrode padadhesiveness● Wipe dry the skinsweat and paste theelectrode pad again●Replace theelectrode padStrengthinconsistency ofPoor connectionbetween host and●Ensure to connectthe host magnetictwo electrode padselectrode padmagnetic bucklebuckle withelectrode padOutage during use●Automatic power-offat the end oftreatment time●Low power●Normal●Charge before useSudden alarmduring use,resulting intreatment pauseElectrode pad fall-offPaste the electrodepad at the treatmentsite againTechnical Parameters:1. Operating voltage: dc.3.7V2. Built-in battery capacity: 230mAh3. Input power: 1VA4. Operating mode: Continuous operation5. Maximum output pulse energy: For the 500Ω load resistance, theenergy value is no greater than 300mJ6. Pulse width: 0.110ms, error: ±30%7. Pulse frequency: 4-50Hz8. Rated load impedance: 500Ω9. Maximum output voltage peak when open circuit: ≤500V10.Treatment strength setting range: 0~15, with the control interval of11. Dimension of host (L×W×H): 44mm*44mm*13mm12. Dimension of electrode pad: circular electrode pad (small):φ60mm;circular electrode pad (big): φ90mm13. Weight: 50g14. Operating temperature:0°C -45°C15. Radio specificationFrequency RangeMax.RF power2402-2480MHz-7.5 dBmWellkang LtdSuite B, 29 Harley Street, London W1G 9QR, UKShenzhen Jumper Medical Equipment Co., LtdAddress: D Building, No. 71, Xintian Road, Fuyong Street,Baoan, Shenzhen, Guangdong, China.Tel: +86-755-26696279IntegratedAcupunctureKnockingScrapingMassage
Website: www.jumper-medical.com

Navigation menu