Shure Microphone 450 Series Ii Users Manual User Guide

450 Series II to the manual b6d2985b-487f-4f8a-a19c-58b4ea25eaa8

2015-02-02

: Shure Shure-Microphone-450-Series-Ii-Users-Manual-491152 shure-microphone-450-series-ii-users-manual-491152 shure pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadShure Shure-Microphone-450-Series-Ii-Users-Manual- 450 Series II Microphone User Guide  Shure-microphone-450-series-ii-users-manual
Open PDF In BrowserView PDF
Model 450 Series II User Guide
WIRING CONNECTIONS
Refer to Figure 1 and Table 1 below. For unbalanced operation, the GREEN wire is connected to the audio input, the
WHITE wire is connected to the audio ground, and the
SHIELD is connected to chassis ground. In some cases, audio ground and chassis ground will be the same.
For balanced operation, the GREEN wire is connected to the
positive audio input, the WHITE wire is connected to the
negative audio input, and the SHIELD is connected to chassis ground.
IMPEDANCE SWITCH
GREEN

The Shure Model 450 Series II is a high output dynamic microphone designed for paging and dispatching applications.
This extremely rugged microphone features an omnidirectional pickup pattern and a frequency response tailored for
optimum speech intelligibility. It also includes an impedance
selection switch and a locking press-to-talk switch. The
press-to-talk switch can be converted to a monitor/transmit
switch with the Shure RK199S Split-Bar Conversion Kit.
Dual impedance
Locking press-to-talk switch
Rugged ARMO-DURR base and case
Adjustable height
Optional monitor/transmit switch conversion kit

PRESS-TO-TALK SWITCH OPERATION
To operate the control bar as a press–to–talk switch, simply
hold it down and begin speaking. When you are finished
speaking, release the control bar.
To lock the control bar in the “on” position, press it down and
pull it forward. To unlock the control bar, push it back and release it.

IMPEDANCE SELECTION
To select high or low impedance, move the impedance selection switch, located under the microphone base, to either the
HIGH or LO position. The switch is factory pre–set to LO.
Shure recommends the low impedance setting if long
lengths of cable are used, or if severe hum is encountered.
Use Shure A95 Line Matching Transformers to match a low
impedance (300 Ω) microphone line to a high impedance
amplifier input.

2005, Shure Incorporated
27C2917 (Rev. 3)

3
BLACK
RED
GREEN
WHITE

WHITE

BLACK

SHIELD

ORANGE
RED

WIRING DIAGRAM

FIGURE 1
Table 1. Typical Cable-to-Connector Wiring
INPUT TYPE

Features
•
•
•
•
•

1 2

HI

GREEN

LO

SHURE MODEL 450 SERIES II
PAGING AND DISPATCHING MICROPHONE

PRESS-TO-TALK SWITCH

YELLOW

UNBALANCED

BALANCED

WIRE
COLOR

FUNCTION

XLR
CONNECTOR

1/4 IN.
PHONE JACK

GREEN

AUDIO

PIN 2

TIP

WHITE

AUDIO GROUND

PIN 3

SLEEVE

SHIELD

CHASSIS GROUND

PIN 1

SLEEVE

GREEN

AUDIO +

PIN 2

TIP

WHITE

AUDIO –

PIN 3

RING

SHIELD

CHASSIS GROUND

PIN 1

SLEEVE

NOTE: The RED and BLACK leads are not part of the audio
circuit. These wires provide a contact closure when the pressto-talk switch is depressed. This closure may be used to control an external relay or a transmit/receive circuit.

CHANGING PTT CIRCUIT TO NORMALLY OPEN
Using microphones in parallel requires a normally open microphone circuit. To modify the press–to–talk switch so that
it provides a normally open circuit, proceed as follows:
1. Remove the screws, washers, and bottom plate from
the microphone.
2. Unsolder the black, red, and white leads from the terminal
of the press–to–talk switch (see Figure 1). Make
sure these leads are still soldered together. If necessary,
resolder them and insulate the connection.
3. Replace the bottom plate and secure it with the screws
and washers removed in Step 1.

Printed in U.S.A.

TRANSMIT/MONITOR SWITCH CONVERSION KIT
When the optional split-bar Transmit/Monitor Switch Conversion Kit is installed, the Monitor bar must be depressed before
the Transmit switch can be depressed, requiring the operator
to verify that the channel is open before transmitting. The
Monitor bar can be locked in the “on” position. The Transmit
bar is momentary and cannot be locked.
NOTE: Transceiver wiring information must be obtained from
the transceiver schematic and/or the manufacturer.

Cable
2.1 m (7 ft.) four-conductor, two conductors shielded,
non-detachable
Case
Two-tone gray ARMO-DURR

SPECIFICATIONS
Type
Dynamic
Frequency Response
200 to 5,000 Hz (see Figure 2)

ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁ
Á
Á
Á
Á
Á
Á
Á
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
Á
Á
Á
Á
Á
Á
Á
Á
Á ÁÁÁÁÁÁÁÁÁÁ Á
TYPICAL FREQUENCY RESPONSE
FIGURE 2

Polar Pattern
Omnidirectional
Impedance (at 1,000 Hz)
High Impedance: 30,000 Ω
Low Impedance: 225 Ω
Recommended Load Impedance
High Impedance: 100,000 Ω
Low Impedance: 1,000 Ω
Output Level (at 1,000 Hz, Open Circuit Voltage)
High Impedance
Low Impedance
–35.0 dBV/Pa*
–57.0 dBV/Pa*
(17.8 mV)
(1.4 mV)
*1 Pa = 94 dB SPL
Switches
Locking Press-to-Talk Switch: Activates microphone circuit and an external relay or control circuit. The microphone circuit is normally shorted.
Impedance Selection Switch: Double-pole, double-throw
slide switch located in the base of the microphone.

OVERALL DIMENSIONS
FIGURE 3
Net Weight
737 grams (1 lb., 10 oz.)
Shipping Weight
1020 grams (2 lb., 4 oz.)
Certification
Conforms to European Union directives, eligible to bear
CE marking; meets European Union EMC Immunity Requirements (EN 50082–1, 1992).
REPLACEMENT PARTS
Cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R96
Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C31C
On/Off Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . RK141S
OPTIONAL ACCESSORIES
Transmit/Monitor Split-Bar Switch Kit . . . . . . . . RK199S

SHURE Incorporated http://www.shure.com
United States, Canada, Latin America, Caribbean:
5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A.
Phone: 847-600-2000 U.S. Fax: 847-600-1212 Intl Fax: 847-600-6446
Europe, Middle East, Africa:
Shure Europe GmbH, Phone: 49-7131-72140 Fax: 49-7131-721414
Asia, Pacific:
Shure Asia Limited, Phone: 852-2893-4290 Fax: 852-2893-4055



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Create Date                     : 2003:07:21 10:18:31-05:00
Modify Date                     : 2009:08:17 10:53:13-05:00
Metadata Date                   : 2009:08:17 10:53:13-05:00
Creator Tool                    : Interleaf, Inc.
Format                          : application/pdf
Creator                         : Shure Incorporated
Title                           : Shure 450 Series II Microphone User Guide
Document ID                     : uuid:22e39d9d-1d44-4717-a7c3-3674cf6b6a2b
Instance ID                     : uuid:1a8ecccc-9d46-4620-952f-b67c87acd82c
Page Count                      : 2
Author                          : Shure Incorporated
EXIF Metadata provided by EXIF.tools

Navigation menu