Siemens Aktiengesellschaft 6021112 WIRELESS GATEWAY/ANCHOR for identification and localization in the WIRELESS LOCATION SYSTEM User Manual 2011 02 14 WIRELESS THR Gateway

Agilion GmbH WIRELESS GATEWAY/ANCHOR for identification and localization in the WIRELESS LOCATION SYSTEM 2011 02 14 WIRELESS THR Gateway

Contents

15a_WIRELESS THR GW UserMan

Download: Siemens Aktiengesellschaft 6021112 WIRELESS GATEWAY/ANCHOR for identification and localization in the WIRELESS LOCATION SYSTEM User Manual 2011 02 14  WIRELESS THR Gateway
Mirror Download [FCC.gov]Siemens Aktiengesellschaft 6021112 WIRELESS GATEWAY/ANCHOR for identification and localization in the WIRELESS LOCATION SYSTEM User Manual 2011 02 14  WIRELESS THR Gateway
Document ID1936094
Application IDX4ITtp/RiJaOKhYcLrrmbA==
Document Description15a_WIRELESS THR GW UserMan
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize14.06kB (175806 bits)
Date Submitted2013-04-10 00:00:00
Date Available2013-04-10 00:00:00
Creation Date2013-03-15 10:53:06
Producing SoftwarepdfFactory Pro 2.23 (Windows XP German)
Document Lastmod0000-00-00 00:00:00
Document Title2011-02-14_user manual WIRELESS THR Gateway.doc
Document CreatorpdfFactory Pro www.pdffactory.com
Document Author: tkr

WIRELESS THR GATEWAY
UserManual
Benutzerhandbuch
FCC ID: SCF6021112
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Modifications not expressly approved by this company could void the user's authority to operate the
equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
This device and its antenna must not be co-located or operating in conjunction with any other antenna
or transmitter.
This device has been designed to operate with the antennas listed below, and having a maximum gain
of 6 dB. Antennas not included in this list or having a gain greater than 6 dB are strictly prohibited for
use with this device. The required antenna impedance is 50 ohms.
IC: 10971A-6021112
This device complies with Industry Canada licence-exempt RSS standards.
Operation is subject to the following two conditions: (1) This device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
This device has been designed to operate with the antennas listed below, and having a maximum gain
of 6 dB. Antennas not included in this list or having a gain greater than 6 dB are strictly prohibited for
use with this device. The required antenna impedance is 50 ohms.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
Ce dispositif a été conçu pour fonctionner avec les antennes indiquées ci-dessous, et
ayant un gain maximum de 6 dB. Il est strictement interdit d’utiliser les antennes ne figurant pas dans
cette liste ou présentant un gain supérieur à 6 dB avec ce dispositif. L’impédance d’antenne requise
est 50 ohms.
Use the following Agilion Antennas only:
• Omni/4.5dBi/N-M
• Omni/6dBi/N-F/360°
Table of contents
English
Scope of delivery .......................................................................................................... 2
Functionality ................................................................................................................. 3
Layout and Connections ............................................................................................... 4
3.1 Connectors and Indicators........................................................................................ 5
3.2
Pin-Assignment ......................................................................................................... 5
Initial operation and installation ................................................................................. 7
Troubleshooting ........................................................................................................... 8
5.1 General errors ........................................................................................................... 8
Technical data............................................................................................................... 9
Declaration of Conformity........................................................................................... 10
20130314-6021112-UM
EN
1 Scope of delivery
•
•
•
EN
1 WIRELESS THR GATEWAY
1 Power plug (5-pole)
1 User manual
20130314-6021112-UM
2 Functionality
The gateways are basing points in the localization network. Furthermore they are the interface
between the IT infrastructure (e.g. Ethernet) and the wireless localization network. The IT infrastructure is used for the exchange of localization information and application specific data between the wireless localization network and the localization server. The use of several gateways is
recommended in larger localization networks for larger amount of mobile tags and highest availability of position information.
20130314-6021112-UM
EN
3 Layout and Connections
35mm
10mm
P1
10
P3
86mm
D2
D1
D5
D6
57mm
S1
P2
P3
Bottom View
P2
EN
20130314-6021112-UM
3.1 Connectors and Indicators
Connection /Indication Specification
S1
Push Button, Factory Defaults
P1 - POWER
Power supply connector
P2 - ETH
Ethernet Receptacle, RJ45
P3 - Antenna
RP-SMA antenna connection
D1 - Radio-LED
Indication of wireless transmissions
D2 - Power-LED
On when running, blinking on error
3.2 Pin-Assignment
P1 - POWER - Connector
P1
6 7 8 9
5-pole connector with clamping screw
0.13 mm2 to 3.3 mm2
Reorder with order number: 6020154
10
Pin
Description
Alarm switsch
GND (Ground)
GND (Ground)
8 to 30 V DC
10
Shield Ethernet
Alarm switch - Pin 6
The high side switch power input Pin 9 to the digital output line Pin 6.
Power Supply
Alarm Switch
Ground
Output Voltage: 0 (disabled) or Power Input Voltage (enabled)
Maximum Output Current: 100 mA
GND
20130314-6021112-UM
EN
P4 - ETH-Connector, RJ45
Pin
Description
Differential Ethernet transmit Data +
Differential Ethernet transmit Data -
Differential Ethernet receive Data +
Differential Ethernet receive Data -
4, 5, 7, 8
not connected
Shield
Shield
D5
Description
D6
Description
Off
No Link
Off
no activity
Yellow
10 MBit
Yellow
half duplex activity
Green
100 MBit
Green
full duplex activity
P3 - Antenna - RP-SMA Connector
EN
Pin
Description
Antenna
Shield
Ground
20130314-6021112-UM
4 Initial operation and installation
1.
The antenna (P3) must be attached to the RP-SMA-connection at the WIRELESS module.
Warning: Do operate the WIRELESS Module without antenna connected. While changing or
removing antenna switch the device off or remove power cable.
Notice: The antennas should be justified in same direction on all WIRELESS modules.
Notice: The WIRELESS modules should be placed line of sight and in a high position for optimised wireless data transmission.
2.
Set up power connection (P1). During start-up all LED’s are flashing once. The power-LED
(D2) keeps on lighting.
3.
The WIRELESS modules must be protected against humidity.
20130314-6021112-UM
EN
5 Troubleshooting
5.1 General errors
EN
Effect
Reason
Module does not work, PowerLED is off
No power connection or not Check power supply, switch
switched on
WIRELESS module on
Flashing Power-LED at normal
operation
Module Error
Action
Switch WIRELESS module off and
on for reset, if error occurs
frequently contact
service@agilion.de
20130314-6021112-UM
6 Technical data
Radio
Wireless technology
IEEE 802.15.4a nanoLOC,
Modulation: Chirp Spread Spectrum (CSS)
Data rates
1 MBit
Operating frequency
2.45 GHz ISM-Band
Chirp-bandwidth
80 MHz
Output power
max. 100 mW, adjustable
Range @ 1 MBit
Indoor max. 90 m, Outdoor max. 1,000 m
Connectors and Power
Supply voltage
8 to 30 V DC
Power consumption
max. 0.2 A
Antenna interface
RP-SMA (male)
Power connector
5-pole connector with clamping screw, 0.13 mm2 to 3.3 mm2,
Order#: 6020154
Ethernet
RJ45 Ethernet
Ethernet
Interface
10/100MBit
Duplexmode
Half-, Fullduplex
Environment
Case
Plastic housing
IP-protection
IP 40
Dimension
35 x 86 x 58 mm
Weight
80 g
Mounting
DIN 60 715 TH35
Temperature range
-40 to +70°C
20130314-6021112-UM
EN
7 Declaration of Conformity
The Agilion GmbH declares the conformity of
WIRELESS THR GATEWAY
according to the requirements of the standards:
EN 300328
EN 301489-1
EN 301489-17
EN 61000-3-2:2000+A1:2005
EN 61000-3-3:1995+A1:2001
EN 55022:1998+A1:2000+A2:2003
EN 55022:1994+A1:1995+A2:1997
EN 55024:1998+A1:2001+A2:2003
EN 60950-1
WIRELESS THR GATEWAY therefore complies with the EC-directives:
R&TTE 1999/5/EC
89/336/EEC
73/23/EWG
This declaration applies to all devices bearing the
made to the product.
Dipl.-Inf. Sven Sieber
(Managing Director)
symbol. Validity is lost if modifications are
Dipl.-Kfm.(FH) Andreas Werner
(Managing Director)
Agilion GmbH
Blankenauer Str. 74
09113 Chemnitz
Germany
EN
10
20130314-6021112-UM
Inhaltsverzeichnis
Deutsch
Lieferumfang ................................................................................................................. 2
Überblick....................................................................................................................... 3
Mechanik und Anschlüsse ............................................................................................ 4
3.1 Anschlüsse und Anzeigen.......................................................................................... 5
3.2
Pin-Belegung ............................................................................................................. 5
Inbetriebnahme und Installation ................................................................................. 7
Behebung von Störungen ............................................................................................. 8
5.1 Allgemeine Fehler...................................................................................................... 8
Technische Daten ......................................................................................................... 9
Konformitätserklärung ............................................................................................... 10
20130314-6021112-UM
DE
1 Lieferumfang
•
•
•
DE
1 WIRELESS THR GATEWAY
1 Power-Stecker (5-polig)
1 Benutzerhandbuch
20130314-6021112-UM
2 Überblick
Die Gateways fungieren wie Ankerknoten als Referenzpunkt zur Lokalisierung, besitzen aber zusätzlich eine Schnittstelle zur Anbindung an eine IT-Infrastruktur (z.B. Ethernet oder USB). Über
diese werden die Daten zur Lokalisierung als auch optional applikationsspezifische Daten zwischen den drahtlosen Lokalisierungsnetzwerk und dem Lokalisierungsserver ausgetauscht. In
größeren Netzwerken ist der Einsatz mehrerer Gateways empfohlen, da so die Anzahl der möglichen Tags und die Verfügbarkeit von Positionsinformationen erhöht werden kann.
20130314-6021112-UM
DE
3 Mechanik und Anschlüsse
35mm
10mm
P1
10
P3
86mm
D2
D1
D5
D6
57mm
S1
P2
P3
Ansicht von Unten
P2
DE
20130314-6021112-UM
3.1 Anschlüsse und Anzeigen
Anschluss / Anzeige
Beschreibung
S1
Taster, Werkseinstellungen
P1 - POWER
Stromversorgung
P2 - ETH
XPort - RJ45 Ethernet
P3 - Antenne
RP-SMA - Antennenanschluss
D1 - Radio-LED
LED zur Signalisierung der Funkaktivität (Senden und Empfangen)
D2 - Power-LED
LED leuchtet wenn Gerät in Betrieb, blinkt bei Fehler
3.2 Pin-Belegung
P1 - POWER - Steckverbinder
P1
6 7 8 9
5-poliger Steckverbinder mit Schraubklemmen
0,13 mm2 bis 3,3 mm2
Nachbestellung mit Bestellnummer: 6020154
10
Pin
Beschreibung
Meldeausgang
GND (Masse)
GND (Masse)
8 bis 30 V DC
10
Schirmung Ethernet
Meldeausgang - Pin 6
Ein High-Side-Switch schaltet die Versorgungsspannung auf den digitalen Ausgang Pin 6.
Versorgungsspannung
Meldeausgang
Masse
Ausgangsspannung: 0 (ausgeschaltet) oder Eingansspannung
(eingeschaltet)
Maximaler Ausgangsstrom: 100 mA
GND
20130314-6021112-UM
DE
P2 - ETH-Buchse, RJ45 (nur bei ETH)
Pin
Beschreibung
Differential Ethernet transmit Data +
Differential Ethernet transmit Data -
Differential Ethernet receive Data +
Differential Ethernet receive Data -
4, 5, 7, 8
Nicht verwendet, abgeschlossen
Gehäuse
Schirmung
D5
Funktion
D6
Funktion
Off
Kein Link
Off
Keine Aktivität
Gelb
10 MBit
Gelb
Halbduplex Aktivität
Grün
100 MBit
Grün
Vollduplex Aktivität
P3 - Antenne - RP-SMA Stecker
DE
Pin
Beschreibung
Antenne
Shield
GND (Masse)
20130314-6021112-UM
4 Inbetriebnahme und Installation
1.
Antenne an RP-SMA-Anschluss (P3) anschließen.
Achtung: Das WIRELESS Modul darf nicht ohne Antenne betrieben werden. Zum Wechseln
oder Entfernen der Antenne ist das Gerät auszuschalten bzw. stromlos zu schalten.
Hinweis: Die Antennen sollten an allen WIRELESS-Modulen gleich ausgerichtet sein.
Hinweis: Um eine optimale Übertragung zu ermöglichen, sollten die WIRELESS-Module möglichst weit oben angebracht werden und Sichtverbindung haben.
2.
Anschluss der Stromversorgung an den Power-Eingang (P1). Dabei leuchten alle LEDs initial
auf. Die Power-LED (D2) leuchtet permanent.
3.
Die WIRELESS-Module müssen vor Feuchtigkeit geschützt werden.
20130314-6021112-UM
DE
5 Behebung von Störungen
5.1 Allgemeine Fehler
DE
Fehlererkennung
Fehlerursache
Fehlerbehebung
WIRELESS-Modul reagiert
nicht, LED leuchtet nicht
Modul nicht angeschlossen
oder nicht eingeschaltet
Stromversorgung des Moduls
prüfen, Modul anschalten
Blinkende Power-LED
während des Betriebs
Fehler in Modul
Rücksetzen durch Aus- & Anschalten des Moduls; tritt der
Fehler mehrfach auf, kontaktieren sie bitte service@agilion.de
20130314-6021112-UM
6 Technische Daten
Funk
Funkverfahren
IEEE 802.15.4a nanoLOC,
Modulationsverfahren: Chirp Spread Spectrum (CSS)
Datenrate
1 MBit
Frequenzbereich
2,45 GHz ISM-Band
Chirp-Bandbreite
80 MHz
Sendeleistung
max. 100 mW, einstellbar
Reichweite @ 1 MBit
Indoor max. 90 m, Outdoor max. 1.000 m
Anschlüsse und Energieversorgung
Spannung
8 bis 30 V DC
Energieaufnahme
max. 0,2 A
Antennenanschluss
RP-SMA-Stecker
Power-Steckverbinder
5-poliger Steckverbinder mit Schraubklemme, 0,13 mm2 bis 3,3 mm2,
Bestell-Nr.: 6020154
Ethernet
RJ45 Ethernet
Ethernet
Interface
10/100MBit
Duplexmode
Halb-, Vollduplex
Umgebung
Gehäuse
Plastikgehäuse
IP-Schutzart
IP 40
Abmessungen
35 x 86 x 58 mm
Gewicht
80 g
Befestigungsmöglichkeiten
Normschiene DIN 60 715 TH35
Temperaturbereich
-40 bis +70°C
20130314-6021112-UM
DE
7 Konformitätserklärung
Die Agilion GmbH erklärt die Konformität von
WIRELESS THR GATEWAY
mit den Anforderungen der Normen:
EN 300328
EN 301489-1
EN 301489-17
EN 61000-3-2:2000+A1:2005
EN 61000-3-3:1995+A1:2001
EN 55022:1998+A1:2000+A2:2003
EN 55022:1994+A1:1995+A2:1997
EN 55024:1998+A1:2001+A2:2003
EN 60950-1
WIRELESS THR GATEWAY entspricht den EG-Richtlinien:
R&TTE 1999/5/EC
89/336/EEC
73/23/EWG
Diese Erklärung gilt für alle Geräte, die das
dukt geht die Gültigkeit verloren.
Dipl.-Inf. Sven Sieber
(Geschäftsführer)
- Zeichen tragen. Bei Veränderungen an dem Pro-
Dipl.-Kfm.(FH) Andreas Werner
(Geschäftsführer)
Agilion GmbH
Blankenauer Str. 74
09113 Chemnitz
DE
10
20130314-6021112-UM
Notes/Notizen:
Agilion GmbH
Blankenauer Straße 74
09113 Chemnitz
Germany
Tel.: +49 - (0)371 - 45 00 48-0
Fax.: +49 - (0)371 - 45 00 48-11
www.agilion.de
service@agilion.de
Management/Geschäftsführung:
Sven Sieber
Andreas Werner
HR B 21249 Chemnitz
USt.-IdNr.: DE236591552

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Title                           : 2011-02-14_user manual WIRELESS THR Gateway.doc
Author                          : tkr
Creator                         : pdfFactory Pro www.pdffactory.com
Producer                        : pdfFactory Pro 2.23 (Windows XP German)
Create Date                     : 2013:03:15 10:53:06
Page Count                      : 24
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SCF6021112

Navigation menu