Siemens MOBYU-SLGU92-1 Write-Read-Station for identification system User Manual data sheet
Siemens AG Write-Read-Station for identification system data sheet
Siemens >
Contents
data sheet
Datenblatt Produkt-Service engl 10.04.2001 09:01 Uhr Seite 1 CM MY CY CMY MOBY U identification system with a read/write range of up to 3 m Latest Information on MOBY Greater and greater demands are being placed on identification systems in the most varied of applications for the automotive industry, logistics and distribution. Large read/write distances, multi-tag capability or rapid and reliable data transfer under difficult conditions are being demanded. Other requirements are that out-of-range distances and reflections do not influence the results of identification, that other 2.4 GHz systems are not subjected to interference and that little effort is needed for installation. Maintenance-free operation and simple system integration are also expected by users as a matter of course. In short, a whole series of requirements for which there are only a few solutions. MOBY U Identification System. And there are many reasons in its favour. By using proven highly-innovative UMTS/GSM technology from the telecommunications sector, it became possible to develop a fast and efficient solution to the known problems encountered with conventional 2.4 GHz systems. MOBY U thus features the performance capability of innovative HT technologies and also ensures continuity thanks to its compatibility with the MOBY I identification system which is already in use all over the world. Main uses in logistics and industrial production • Main assembly lines in the automotive industry (bodyshell construction, paintshop, assembly) • Vehicle identification/road access monitoring for haulage companies, depots etc. • Containers/pallets/load-carrier identification in transport logistics and distribution • Traffic control systems • Assembly lines. World-wide certification MOBY U has been designed and certified for heavy industrial use all round the world. It uses the globally certified ISM frequency band at 2.4 GHz and its emission level of < 10 mW is far below international limits, thus excluding the possibility of any damage to health. SOLUTIONS Probedruck Simple start-up and years of maintenance-free operation The use of proven and innovative UMTS/GSM technologies were the preconditions which enabled the following: • A homogeneous transmission field with circular polarization makes antenna tuning unnecessary. • Reflections, interference and overreach are actively excluded. • Automatic selection of free channels • Automatic mutual synchronization of up to 3 write/read units • Can be directly mounted on metal • Service functions for rapid fault analysis Datenblatt Produkt-Service engl 10.04.2001 09:01 Uhr Seite 2 CM MY CY CMY The main characteristics at a glance – Innovative technologies simplify configuration, start-up and maintenance • It uses the globally certified ISM frequency band at 2.4 GHz • Transmission ranges up to 3 m can be limited in steps by software programming • Read/write with a high level of net data transmission speeds of up to 16 Kbyte/s • Innovative GMS and UMTS functions feature: • a high level of data integrity • suppression of overreach/reflections and interference • simple start-up, i.e. no interferencesource measurement and antenna alignment • no effect on other users in the frequency band thanks to automatic selection of free channels without interference (frequency hopping) and very low emission values < 10 mW, EIRP • Wide selection of robust data memories with a RAM of up to 32 Kbytes (prepared for up to 256 Kbytes) and up to +85 °C or +220 °C cyclically • Multi-tag capability (up to 12 MDS) • File handling with data access via logical addresses (similar to DOS) Siemens AG Automation & Drives Systems Engineering P.O. Box 23 55 D-90713 Fürth, Germany Siemens Aktiengesellschaft Probedruck • Call-compatible with MOBY I • Mobile hand terminal (available soon) • Designed and certified for heavy industrial use all round the world: CE, BAPT, FCC, UL and CSA • Ability to cope with future developments thanks to standardization acc. to ISO 18000-4 • World-wide support and service Mobile data memories MDS U 313, MDS U 524 and MDS U 589 • 2 or 32 Kbyte RAM • 32-bit serial number incl. 16 byte uniquely recordable fixed code memory • High degree of protection up to IP 68 • Operating temperature: -25 °C to +85 °C • Special heat-resistant data memory up to +220 °C for e.g. paintshop incl. KTL • Robust long-life housing with the dimensions (mm): 111 x 67 x 23.5 or ø 114 x 83 (MDS U 589). SLG U 92 read/write unit • Max. read/write distance: 3 m, can be limited in steps by means of software • Integrated antenna: with circular polarization Subject to change without prior notice Order No. E80001-A78-P330-X-7600 Printed in Germany 21C6968.MK.SE.MB.MOBY.52.1.06 WS 04012.0 SEK. 30472 Dispostelle 06350 • RS422 or RS232 interface for link-up to any systems • RS232 service interface • Degree of protection IP 65 • Operating temperature: -25 °C to +70 °C • Dimensions (mm): 290 x 135 x 42 (without connector) MOBY U with tailor-made system integration for simple incorporation in the respective application • System integration by means of interface module (ASM 452, ASM 473, ASM 475), including FC for PROFIBUS-DP-V1 and SIMATIC S7 • Windows 98/NT C library for direct integration in the PC/SICOMP • Can be integrated in any system via RS232/RS422 More Information? Gladly! Siemens AG – A&D SE MI 1 Automation & Drives P.O. Box 23 55 D-90713 Fürth, Germany Tel.: +49 (0) 911-750 27 66 Fax: +49 (0) 911-750 48 88 e-mail: moby@fthw.siemens.de Web: www.siemens.de/moby Excellence in Automation & Drives: Siemens
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2001:04:10 09:03:52 Producer : Acrobat Distiller 4.05 for Macintosh Modify Date : 2001:04:10 18:03:35+02:00 Page Count : 2EXIF Metadata provided by EXIF.tools