Siemens MOBYU-SLGU92-1 Write-Read-Station for identification system User Manual product information sheet

Siemens AG Write-Read-Station for identification system product information sheet

product information sheet

   File: Produktinfo_SLG U92_FCC_V01_00_e.doc    1 of 1 Subject to change without prior notice    MOBY U    Product Sheet Read/Write Device - SLG U92 with FCC  Version:  01.00 of 19.09.02   A&D SE PS 3, R. Völler  Description  The SLG U92 is a read/write device with integrated antenna for long range applications. It is designed especially for the automotive industry and industrial production plants. It uses the transmission frequency of 2.4 GHz of the worldwide approved ISM frequency band. This permits transmission distances from just a few centimeters to up to three meters with a very low sending power of < 50 mV/m at distance of 3 m and high net transmission speeds of up to 8 Kbytes per second. Transmission frequency, robust modula-tion procedures and check routines can be selected so that electromagnetic interference can be disre-garded, and error-free data transmission and integrity are still ensured. The antenna field of the SLG can be activated and deactivated via function call or automatically with a proximity switch during communica-tion with an MDS.  MOBY U technology stops familiar interference during UHF transmissions such as reflection, interfer-ence and over-the-horizon transmissions.The specially designed antennas provide a homogeneous transmission field and ensure 100% detection of mobile data memories (MDSs). This makes expensive shielding and antenna setting unnecessary.  With its mobile data memories MDS U524 and MDS U589 (up to +220° C, cyclic) and 32 Kbytes of stor-age space, MOBY U meets the prerequisites for a transparent solution in the automotive industry.  The SLG U92 offers inexpensive system integration via coupling to: •  Proven MOBY interface modules (ASM) for PROFIBUS-DP-V1 and SIMATIC S7 •  Directly to standard PC, SICOMP or PC-PLC Software tools such as the SIMATIC S7 functions (FC) and C library (MOBY API) for applications under Windows 98/NT make implementation in the particular application simple.  The powerful but easy-to-use filehandler with logical file addressing which we all known from MOBY I is directly integrated in the SLG U92 with expanded functionality. The commands MOVE and LOAD from the MOBY I filehandler are a thing of the past. The SLG always fetches the required file management information directly from the MDS. MOBY U can be run in three stages.  1.  MOBY U can be run with standard settings, with unchanged filehandler functions and without the MOVE and LOAD commands for existing system solutions with MOBY I. 2.  Only a few expanded commands are required for changes in the standard settings and the require-ments of diagnostic data.  3.  Full utilization of MOBY U performance. In this stage, the commands and/or user data can also be securely assigned to the particular MDS number.  In addition to filehandler mode, the MDSs can use direct byte addressing as with the other MOBY identi-fication systems.  A separate service and diagnostic interface makes it simple to commission and trouble-shoot during operation. In addition, this interface can be used with the service function "load software to SLG" in exist-ing applications for future function expansions without having to exchange the SLG.
MOBY U  Product Sheet  Version 01.00 Read/Write Device SLG U92    19.09.02       File: Produktinfo_SLG U92_FCC_V01_00_e.doc    2 of 2 Subject to change without prior notice  Ordering Data                                           Product Description Order No. L-Price        EURO/Unit AL ECCN Read/write device SLG U92 with RS 422 with FCC 6GT2501-0BA00  on demand  N   Read/write device SLG U92 with RS 232 with FCC 6GT2501-1BA00  on demand  N     Technical Data  SLG type Identification system  SLG U92 MOBY U  Air Interface   Transmission frequency  2.4 to 2.4835 GHz Bandwidth  2 x 1 MHz within 83 MHz Modulation procedure  GMSK (BT=0.5) in downlink or DBPSK in uplink Gross bit rate of radio channel  384 kbit/sec Check routines  Forward correction with systematic block code (CRC), ARQ procedure Error rate  < 1 read error for every 106 transactions Net data rate (read/write)  Approx. 8/4.8 Kbyte/sec without pileup Approx. 4/2.4 Kbyte/sec with pileup size 2 Range (read/write)  0.15 m to 3 m Limit distance (Lg)   Limit distance = range limitation Max./min./standard  3 m/0.5 m/2 m Location resolution  Range limitation (adjustable in steps of 0.5 m) Working distance (La)  Approx. 75% of limit distance  Field length/width at Lg = 1.5 m  2 m Read/write device (SLG)   Functions  MOBY filehandler (file manager) Direct read/write Multiple identification capability  Up to 12 MDSs MDS acquisition time  > 2 sec with 12 MDSs Object's speed  <  2 m/sec at La = 1.5 m and read/write < 2.5 Kbytes of data Power supply  24 V DC (nominal value), 20 V DC to 30 V DC Limited Power Source according EN 60950/IEC 60950 Current consumption (send)  < 300 mA Operating modes  SLG: Standby, search, communication Synchronization, SLG - SLG  Via semaphore control over 2nd interface, max. of 3 SLGs together Minimum distance between two SLGs  > 6 m, with synchronization directly next to each other Two interfaces for:   ASM 452/ASM 475 or PC  6-pin SLG plug connector in acc. w. EN 175201-804 RS 232 or RS 422 (SLG U92 model) Transmission speed  19.2 to 115.2 KBaud (depending on cable length) Transmission protocol  3964 R Cable length, SLG - ASM  Max. of 1000 m (shielded) Cable length, SLG - PC  Max. of 30 m/300 m (shielded) Service, 2 DIs and SLG synchroniza-tion  11-pin plug connector in acc. w. EN 175201-804
MOBY U  Product Sheet  Version 01.00 Read/Write Device SLG U92    19.09.02       File: Produktinfo_SLG U92_FCC_V01_00_e.doc    3 of 3 Subject to change without prior notice Interface for service  RS 232 Transmission speed  19.2 KBaud Cable length, SLG - PC  Max. of 30 m Transmission protocol  Terminal, ASCII characters 2 DIs for proximity switch   DI 1/DI 2  Proximity switch for triggering antenna field, on/off DI 1 (or DI 2)  Proximity switch for continuous antenna field, on Cable length, SLG - proximity switch  Max. of  50 m Interface for SLG synchronization   Cable length, SLG - SLG  Max. of 30 m Indicator elements  2 LEDs Housing   Dimensions [L x W x H]  290 x 135 x 42 (without plug) Color/material  Anthracite/plastic PA 12 GF 25 Mounting  4 M6 screws Shock/oscillation in acc. w. DIN EN 60721-3-7, class 7 M3  30 g/1.5 g MTBF (at +40° C)  0.4 x 106 hours Protection rating in acc. w. DIN EN 60529  IP 65 Ambient temperature   Operation/transportation and storage  -25° C to +70°  C/-40° C to +85° C Weight, approx.  800 g Antenna  Integrated in SLG Antenna efficiency  < 50 mV/m at distance of 3 m/< 0.5  W/cm2 (at distance of 1 m) Receiving sensitivity  -95 dBm Gain     5 dBi Emission towards back  -20 dB front/back Opening angle  Approx. 90° horizontal/vertical Polarization  Circular Certifications  RF:  I-ETS 330440+C1:1997 SAR:   99/519/EG Safety: EN 60950:2000 EMC:  EN 301489-01:2000   EN 301489-03:2000   ENV 50204:1995   FCC Part 15C  CULUS    Safe for pacemakers   Field Data    Standard Minimum Maxi-mum   Limit distance (Sg), approx.  2.0 m  0.50 m  3.0 m Working distance (Sa)  1.4 m  0.35 m  2.1 m Transmission window at Sa    Length/width  2.0 m  0.70 m  2.1 m Over-the-horizon transmissions can be actively limited (in 0.5 m steps from 0.5 m to 3.5 m) by SLG.    The field data apply to reading and writing the MDS with SLG U92 with FCC certification.
MOBY U  Product Sheet  Version 01.00 Read/Write Device SLG U92    19.09.02       File: Produktinfo_SLG U92_FCC_V01_00_e.doc    4 of 4 Subject to change without prior notice  Dimensional Drawing - SLG U92   6-pin SLG plug connector in acc. w. EN 175201-804  for ASM/PC RS 422 or RS 232 11-pin plug connector in acc. w. EN 175201-804 for service interface, proximity switch and synchronization 42