Siemens RF620R UHF RFID READER User Manual System Manual RF600 en

Siemens AG UHF RFID READER System Manual RF600 en

User Manual

Download: Siemens RF620R UHF RFID READER User Manual System Manual RF600 en
Mirror Download [FCC.gov]Siemens RF620R UHF RFID READER User Manual System Manual RF600 en
Document ID1083920
Application IDVMJ+B4XEz5KTYdFmeiIjog==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize61.15kB (764375 bits)
Date Submitted2009-03-23 00:00:00
Date Available2009-03-23 00:00:00
Creation Date2009-03-05 16:21:33
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2009-03-10 15:42:56
Document TitleMicrosoft Word - System_Manual_RF600_en.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: ADTASV0

Table of contents
1.1
1.1.1
1.1.1.1
1.1.1.2
1.1.1.3
1.1.1.4
1.1.1.5
1.1.2
1.1.2.1
1.1.2.2
1.1.2.3
1.1.3
1.1.4
1.1.4.1
1.1.5
1.1.5.1
1.1.5.2
1.1.5.3
1.1.6
1.1.7
RF620R reader ..............................................................................................................................7
Description .....................................................................................................................................7
Ordering data .................................................................................................................................8
Status display.................................................................................................................................9
Pin assignment of the RS422 interface .......................................................................................10
Pin assignment of the connecting cable ......................................................................................10
Grounding connection..................................................................................................................11
Planning application.....................................................................................................................11
Minimum mounting clearances of two readers ............................................................................11
Antenna diagram for RF620R (ETSI) ..........................................................................................12
Antenna/read point configurations ...............................................................................................15
Installing/Mounting .......................................................................................................................15
Configuration/integration..............................................................................................................16
Transmission protocols ................................................................................................................17
Technical data..............................................................................................................................17
Mechanical data ...........................................................................................................................17
Technical data according to EPC and ISO ..................................................................................18
Maximum number of readable tags .............................................................................................19
Dimension drawings.....................................................................................................................20
Certificates and approvals ...........................................................................................................20
1.2.1
1.2.1.1
1.2.1.2
1.2.1.3
1.2.1.4
1.2.1.5
1.2.2
1.2.2.1
1.2.2.2
1.2.3
1.2.4
1.2.4.1
1.2.4.2
1.2.5
1.2.5.1
1.2.5.2
1.2.5.3
1.2.6
1.2.7
21
Description ...................................................................................................................................22
Ordering data ...............................................................................................................................23
Status display...............................................................................................................................24
Pin assignment of the RS422 interface .......................................................................................25
Pin assignment of the connecting cable ......................................................................................25
Grounding connection..................................................................................................................26
Planning application.....................................................................................................................26
Minimum mounting clearances of two antennas of different readers ..........................................26
Antenna/read point configurations ...............................................................................................27
Installing/Mounting .......................................................................................................................27
Configuration/integration..............................................................................................................28
Configuration................................................................................................................................28
Transmission protocols ................................................................................................................29
Technical data..............................................................................................................................29
Mechanical data ...........................................................................................................................29
Technical data according to EPC and ISO ..................................................................................30
Maximum number of readable tags .............................................................................................31
Dimension drawings.....................................................................................................................32
Certificates and approvals ...........................................................................................................32
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
1
Readers
1.1
RF620R reader
1.1.1
Description
The SIMATIC RF620R is an active stationary reader in the UHF frequency range with an
integrated circular polarized antenna.
The SIMATIC RF620R is connected to a SIMATIC S7 controller via an ASM interface
module. The degree of protection corresponds to IP 65.
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Item
Description
(1)
LED operating indicator
(2)
RS 422 interface
(8-pin M12 socket)
Readers
1.1 RF620R reader
Highlights
● The tags are read in accordance with the requirements of the EPCglobal Class 1, Gen 2
and ISO/IEC 18000-6C standards
● Supports low-cost SmartLabels as well as reusable, rugged data media
● High reading speed: Depending on the function block (multitag mode), many tags can be
detected simultaneously (bulk reading), rapidly moving tags are reliably acquired.
● The RF620R (ETSI) "6GT2811-5BA00-0AA0" is suitable for the frequency band 865 to
868 MHz UHF (EU, EFTA, Turkey).
● IP65 degree of protection for reader
● Can be used for a high temperature range
● Dense Reader Mode (DRM) for environments in which many readers are operated in
close proximity to each other
● TIA system interface:
– RS 422
1.1.1.1
Ordering data
Device
Order No.
RF620R (ETSI) reader basic unit for EU, EFTA, Turkey
6GT2811-5BA00-0AA0
Accessories
Description
Order No.
RS 422, M12 plug, 8-pin socket: 2 m
6GT289-0FH20
RS 422, M12 plug, 8-pin socket: 5 m
6GT289-0FH50
RS 422, M12 plug, 8-pin socket: 10 m
6GT289-0FN10
RS 422, M12 plug, 8-pin socket: 20 m
6GT289-0FN20
RS 422, M12 plug, 8-pin socket: 50 m
6GT289-0FN50
Antenna mounting kit
Standard
6GT2890-0AA00
Software & Documentation
CD-ROM
6GT2080-2AA10
Connecting cable
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.1 RF620R reader
1.1.1.2
Status display
The device is equipped with a three colored LED. The LED can be lit in green, red or yellow.
The meaning of the indication changes in accordance with the color and state (on, off,
flashing) of the LED:
Green
LED
Red LED
Yellow
LED
Meaning
Off
Off
Off
The device is starting up.
Flashing
Off
Off
The device is ready. The antenna is switched off.
On
Off
Off
The device is ready. The antenna is switched on.
Off
Off
On
"With presence": At least one tag is in the field.
"Without presence": Communication with a tag is active.
Off
Flashing
Off
Reader is not active, a serious error has occurred. In addition, this LED also indicates
the fault status through the number of flashing pulses. Reboot (operating voltage Off
→ On is necessary).
The LED flashes once for the 'INACTIVE' status, rebooting is not necessary in this
case.
For more detailed information on the flash codes of the reader see Chapter Error messages
and flash codes for RF620R/RF630R (Page Fehler! Textmarke nicht definiert.)
Note
LED not lit yellow?
If the LED does not light up yellow even though a tag is located within the field, common
causes are:
• Incorrect configuration in the init_run command, or init_run command was not executed
(see "Configuration Manual RF620R/RF630R")
• Antenna is switched off
• A tag is used, that is not compatible with the reader protocol (EPC Global Class 1 Gen 2).
• Tag is defective
• Reader or antenna has a defect
• Tag is not in the field of radiation of the transmit antenna
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.1 RF620R reader
1.1.1.3
Pin assignment of the RS422 interface
Pin
Pin
Device end
8-pin M12
Assignment
+ 24 V
- Transmit
0V
+ Transmit
+ Receive
- Receive
Free
Earth (shield)
The knurled bolt of the M12 plug is not connected to the shield (on the reader side).
Note
You must therefore not use any SIMATIC connecting cables that use the angled M12 plug.
1.1.1.4
Pin assignment of the connecting cable
Table 1- 1
10
RS 422 - on reader side
M12 pin
Core color
Pin assignment
white
24 V DC
brown
TX neg
green
GND
yellow
TX pos
Gray
RX pos
pink
RX neg
blue
Not used
red
Earth (shield)
View of M12 connector
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.1 RF620R reader
Note
This cable has an 8-pin M12 connector at one end and the other cable end is 'open'. There
are 8 color-coded single cores there for connecting to external devices. There are different
cable lengths in the product range (3 m to 50 m). Long cables can be reduced if necessary.
Note
For long cables: Adapt supply voltage and data rate accordingly
Note that with long cables in particular, the supply voltage of 24 V DC must always be
applied. Note also that the data rate on the serial interface must, if necessary, be reduced.
(See "Configuration Manual RF620R/RF630R")
1.1.1.5
Grounding connection
The RF620R/RF630R can be electrically connected to the ground potential through a contact
washer. The tightening torque must be increased in this case to ensure that electrical contact
is made (2.7 Nm).
Ground connection
(a)
Hexagon-head screw
(b)
Plain washer
(c)
Cable lugs
(d)
Contact washer:
Use contact washers according to the
Siemens standard SN 70093-6-FSt-flNnnc480h for ground connection,
Siemens item No.: H70093-A60-Z3
1.1.2
Planning application
1.1.2.1
Minimum mounting clearances of two readers
The RF620R has a circular polarized antenna. At 500 mW ERP radiated power, due to the
opening angle of the antennas, their fields can overlap considerably. It is no longer possible
to clarify in which antenna field access to the data of a tag is performed.
In order to avoid this, always keep a minimum distance of 3 m between two readers with the
maximum radiated power of 500 mW ERP.
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
11
Readers
1.1 RF620R reader
Dense Reader Mode (DRM)
The readers can also interfere with each other (secondary fields), if the channels (Reader
TX, Transponder TX) overlap. In order to prevent a transponder channel overlapping with a
reader channel, we recommend that the Dense Reader Mode (DRM) is used.
1.1.2.2
Antenna diagram for RF620R (ETSI)
The following radiation diagrams show the directional radiation pattern of the internal
antenna of the RF620R (ETSI) reader. For the spatial presentation of the directional
radiation pattern, the vertical plane in space (Azimuth section) as well as the horizontal plane
(elevation section) must be considered. This results in a spatial image of the directional
radiation pattern of the antenna with its main and auxiliary fields.
$]LPXW;=
(OHYDWLRQ<=
12
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.1 RF620R reader
Radiation diagram (Azimuth section)
Vertical component of the polarization direction of the antenna
Horizontal component of the polarization direction of the antenna
Figure 1-1
Azimuth section
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
13
Readers
1.1 RF620R reader
Radiation diagram (elevation section)
Vertical component of the polarization direction of the antenna
Horizontal component of the polarization direction of the antenna
Figure 1-2
14
Elevation section
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.1 RF620R reader
Overview of the antenna parameters
Table 1- 2
Maximum linear electrical opening angle at 865 MHz:
Azimuth section
77,7°
Elevation section
66,1°
Typical antenna gain in the frequency range 865
to 868 MHz
7,3 dBic
Antenna axis ratio
0,7 dB
See also Chapter Guidelines for selecting RFID UHF antennas (Page Fehler! Textmarke
nicht definiert.)
1.1.2.3
Antenna/read point configurations
The RF620R reader has an internal circular polarized antenna. You can cover one read point
with this antenna. When several RF620R readers are used, the readers are addressed via
the SIMATIC level.
1.1.3
Installing/Mounting
Requirement
WARNING
Ensure that the wall or ceiling can hold four times the total weight of the device.
Mounting/installing the device
You can mount the reader in two different ways:
● Via a standardized VESA 100 mounting system using the Antenna Mounting Kit (see
Chapter Mounting with antenna mounting kit (Page Fehler! Textmarke nicht definiert.))
● Directly onto a flat surface.
The positions of the fixing holes for the device are shown in the section Dimension drawings
(Page 20).
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
15
Readers
1.1 RF620R reader
1.1.4
Configuration/integration
The RS422 system interface is provided for integrating the device into system
environments/networks. The system interface transfers the data to SIMATIC controllers or
PCs with the appropriate interface.
Apart from transmitting communication data from the reader to the controller and vice versa,
the RS422 interface also supplies power to the reader (24 V DC).
6,0$7,&6
3URILEXV
3URILQHW
5)5
56'&9
5)&
Figure 1-3
5)& $60
Overview of configuration of the RF620R reader
The RF620R reader can alternatively be connected to a SIMATIC controller via the ASM
456, RF170C or RF180C interface modules/communication modules.
For further details on the interface modules used, see Chapter RF660R (Page Fehler!
Textmarke nicht definiert.) .
Further information about commissioning the readers can be found in the configuration
manual "RF620R/RF630R" in the "Commissioning" section.
16
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.1 RF620R reader
1.1.4.1
Transmission protocols
RS 422 communication
3964R protocol
Transmission rates
19.2 Kbaud/s
57.6 Kbaud
115,2 Kbaud/s
Start bits
Data bits
Parity
Odd
Stop bits
1.1.5
Technical data
1.1.5.1
Mechanical data
Mechanical data
Weight
1850 g
Dimensions (L x W x H) in mm
252 X 193 x 52 mm, without connections
Material for housing top section
ABS (GF 20)
Material for housing bottom section
Aluminum
Color of housing top section
Pastel turquoise
Color of housing bottom section
Silver
Status displays on the device
1 LED
Colors: Red, yellow, green
Interfaces
RS422
1 x plug (8-pin M12)
Software
SIMATIC S7
Technical properties
MTBF (Mean Time Between Failures)
16 years
Supply voltage
Current consumption
(in standby mode, no
transmit power)
Power consumption (in
standby mode, no transmit
power)
20 V input voltage on the reader, typical
135 mA
2.7 W
24 V input voltage on the reader, typical
115 mA
2.76 W
30 V input voltage on the reader, typical
95 mA
2.85 W
Current consumption
(at 500 mW ERP)
Power requirement
(at 500 mW ERP)
470 mA
9.4 W
Supply voltage
20 V input voltage on the reader, typical
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
17
Readers
1.1 RF620R reader
24 V input voltage on the reader, typical
395 mA
9.48 W
30 V input voltage on the reader, typical
320 mA
9.6 W
Ramp-up time, typical
7s
Mechanical environmental conditions
Shock resistant to EN 60068-2-27
Vibration EN 60068-2-6
50 g1
20 g1
Climatic Conditions
Ambient temperature during operation
-25 °C to +55 °C
(warm-up time of 10 minutes must be observed)
Ambient temperature for transport and storage
-40 °C to +85 °C
EMC & approvals RF620R (ETSI)
Electromagnetic compatibility
ETSI EN 301 489-1 / -3
ETSI EN 302 208
Approvals
•
•
•
•
•
Radio to R&TTE- guidelines EN 300 330, EN 301 489
CE
ETSI EN 302-208 V1.1.2
ETSI EN 302-208 V1.2.1
Reader degree of protection acc. to EN 60529 (IP65)
The values for shock and vibration are maximum values and must not be applied
continuously.
1)
1.1.5.2
Technical data according to EPC and ISO
Technical data
Frequency accuracy
max.Âą 10 ppm
Channel spacing
EU: 200 kHz
US: 500 kHz
China: 250 kHz
Modulation methods
ASK: DSB modulation & PR-ASK modulation
Encoding, Manchester or Pulse Interval (PIE)
Effective Radiant Power
(the radiant power depends on the antennas and cables
used, see Guidelines for selecting RFID UHF antennas
(Page Fehler! Textmarke nicht definiert.) )
≤ 0.5 W ERP
ETSI frequencies
Frequency bands for EU, EFTA, Turkey:
18
865 to 868 MHz (10 subchannels LBT at 2 W ERP, 12
subchannels at 0.5 W ERP, 15 subchannels LBT at 0.1 W
ERP)
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.1 RF620R reader
Read distance for EU, EFTA, Turkey / China
Readers mounted on the same side
1.1.5.3
Max. 2 m (recommended maximum value for configuration;
depending on the transponder)
Maximum number of readable tags
The maximum number of readable tags depends on the following parameters:
● Size of the antenna field
● Readability of the tags
For a transmit power of 500 mW ERP, the following is read when the tag RF620T is used:
● Max. 40 tags in the antenna field (tags perpendicular to antenna and 1 m in front)
● Max. 18 tags per second
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
19
Readers
1.1 RF620R reader
Dimension drawings

1.1.6
ࡘ






Figure 1-4
Dimension drawing for RF620R
All dimensions in mm
1.1.7
Certificates and approvals
Certificate
Description
CE Approval to R&TTE
20
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.1 RF620R reader
1.1.8
Certificates RF620R (FCC)
Tabelle 1- 3
6GT2811-5BA00-1AA0
Norm
FCC CFR 47, Part 15 sections 15.247
Federal Communications
Commission
Industry Canada Radio
Standards Specifications
Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
FCC ID: NXW-RF620R
RSS-210 Issue 7, June 2007 ,Sections 2.2, A8
IC: 267X-RF620R
Dieses Produkt ist nach UL fĂźr USA und Canada zertifiziert.
Es erfĂźllt folgende Standard(s) for Safety:
UL 60950-1 - Information Technology Equipment Safety - Part 1:
General Requirements
CSA C22.2 No. 60950 -1 - Safety of Information Technology
Equipment
UL Report E 205089
1.1.9
FCC Information
Siemens SIMATIC RF620R (FCC): 6GT2811-5BA00-1AA0
FCC ID: NXW-RF620R
This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
21
Readers
1.2 RF630R reader
FCC Notice
To comply with FCC part 15 rules in the United States, the system must be professionally
installed to ensure compliance with the Part 15 certification.
It is the responsibility of the operator and professional installer to ensure that only certified
systems are deployed in the United States. The use of the system in any other combination
(such as co-located antennas transmitting the same information) is expressly forbidden.
FCC Exposure Information
To comply with FCC RF exposure compliance requirements, the RF620R Reader (antenna
and transmitter) must be installed to provide a separation distance of at least 20 cm from all
persons and must not be co-located or operating in conjunction with any other antenna or
transmitter.
1.2
RF630R reader
1.2.1
Description
The SIMATIC RF630R is an active stationary reader in the UHF frequency range without an
integrated antenna. Up to two external UHF RFID antennas can be connected via TNC
reverse connections.
The maximum HF power output is 0.5 W on the reader output. The SIMATIC RF630R is
connected to a SIMATIC S7 controller via an ASM interface module. The degree of
protection is IP65.
22
Item
Description
(1)
TNCreverse interface for
connection of antenna 1
(ANT 1)
(2)
TNCreverse interface for
connection of antenna 2
(ANT 2)
(2)
LED operating indicator
(3)
RS 422 interface
(8-pin M12 connector)
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.2 RF630R reader
Highlights
● The tags are read in accordance with the requirements of the EPCglobal Class 1, Gen 2
and ISO/IEC 18000-6C standards
● Supports low-cost SmartLabels as well as reusable, rugged data media
● High reading speed: Depending on the function block (multitag mode), many tags can be
detected simultaneously (bulk reading), rapidly moving tags are reliably acquired.
● The RF630R (ETSI) "6GT2811-4AA00-0AA0" is suitable for the frequency band 865 to
868 MHz UHF (EU, EFTA, Turkey).
● Up to 2 external antennas can be connected and configured in operating mode
● IP65 degree of protection for reader
● Can be used for a high temperature range
● Dense Reader Mode (DRM) for environments in which many readers are operated in
close proximity to each other
● TIA system interface:
– RS 422
1.2.1.1
Ordering data
Device
Order No.
RF630R (ETSI) reader basic unit for EU, EFTA, Turkey
6GT2811-4AA00-0AA0
RF660A antennas for EU, EFTA, Turkey (868 MHz)
6GT2812-0AA00
Accessories
Antenna cable
Connecting cable
Software & Documentation
Description
Order No.
3 m (cable attenuation: 1,0 dB)
6GT2815-0BH30
10 m (cable attenuation: 4,0 dB)
6GT2815-0BN10
20 m (cable attenuation: 4,0 dB)
6GT2815-0BN20
RS 422, M12 plug, 8-pin socket: 2 m
6GT289-0FH20
RS 422, M12 plug, 8-pin socket: 5 m
6GT289-0FH50
RS 422, M12 plug, 8-pin socket: 10 m
6GT289-0FN10
RS 422, M12 plug, 8-pin socket: 20 m
6GT289-0FN20
RS 422, M12 plug, 8-pin socket: 50 m
6GT289-0FN50
RFID CD-ROM
6GT2080-2AA10
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
23
Readers
1.2 RF630R reader
1.2.1.2
Status display
The device is equipped with a three colored LED. The LED can be lit in green, red or yellow.
The meaning of the indication changes in accordance with the color and state (on, off,
flashing) of the LED:
Green
LED
Red LED
Yellow
LED
Meaning
Off
Off
Off
The device is starting up.
Flashing
Off
Off
The device is ready. The antenna is switched off.
On
Off
Off
The device is ready. The antenna is switched on.
Off
Off
On
"With presence": At least one tag is in the field.
"Without presence": Communication with a tag is active.
Off
Flashing
Off
Reader is not active, a serious error has occurred. In addition, this LED also indicates
the fault status through the number of flashing pulses. Reboot (operating voltage Off
→ On is necessary).
The LED flashes once for the 'INACTIVE' status, rebooting is not necessary in this
case.
For more detailed information on the flash codes of the reader see Chapter Error messages
and flash codes for RF620R/RF630R (Page Fehler! Textmarke nicht definiert.)
Note
LED not lit yellow?
If the LED does not light up yellow even though a tag is located within the field, common
causes are:
• Incorrect configuration in the init_run command, or init_run command was not executed
(see "Configuration Manual RF620R/RF630R")
• Antenna is switched off
• A tag is used, that is not compatible with the reader protocol (EPC Global Class 1 Gen 2).
• Tag is defective
• Reader or antenna has a defect
• Tag is not in the field of radiation of the transmit antenna
24
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.2 RF630R reader
1.2.1.3
Pin assignment of the RS422 interface
Pin
Pin
Device end
8-pin M12
Assignment
+ 24 V
- Transmit
0V
+ Transmit
+ Receive
- Receive
Free
Earth (shield)
The knurled bolt of the M12 plug is not connected to the shield (on the reader side).
Note
You must therefore not use any SIMATIC connecting cables that use the angled M12 plug.
1.2.1.4
Pin assignment of the connecting cable
Table 1- 4
RS 422 - on reader side
M12 pin
Core color
Pin assignment
white
24 V DC
brown
TX neg
green
GND
yellow
TX pos
Gray
RX pos
pink
RX neg
blue
Not used
red
Earth (shield)
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
View of M12 connector
25
Readers
1.2 RF630R reader
Note
This cable has an 8-pin M12 connector at one end and the other cable end is 'open'. There
are 8 color-coded single cores there for connecting to external devices. There are different
cable lengths in the product range (3 m to 50 m). Long cables can be reduced if necessary.
Note
For long cables: Adapt supply voltage and data rate accordingly
Note that with long cables in particular, the supply voltage of 24 V DC must always be
applied. Note also that the data rate on the serial interface must, if necessary, be reduced.
(See "Configuration Manual RF620R/RF630R")
1.2.1.5
Grounding connection
The RF620R/RF630R can be electrically connected to the ground potential through a contact
washer. The tightening torque must be increased in this case to ensure that electrical contact
is made (2.7 Nm).
Ground connection
(a)
Hexagon-head screw
(b)
Plain washer
(c)
Cable lugs
(d)
Contact washer:
Use contact washers according to the
Siemens standard SN 70093-6-FSt-flNnnc480h for ground connection,
Siemens item No.: H70093-A60-Z3
1.2.2
Planning application
1.2.2.1
Minimum mounting clearances of two antennas of different readers
At 500 mW ERP radiated power, due to the opening angle of the antennas, their fields can
overlap considerably. It is no longer possible to clarify in which antenna field access to the
data of a tag is performed.
In order to avoid this, always keep a minimum distance of 3 m between two antennas of
different RF630R readers with the maximum radiated power of 500 mW ERP.
26
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.2 RF630R reader
Dense Reader Mode (DRM)
The readers can also interfere with each other (secondary fields), if the channels (Reader
TX, Transponder TX) overlap. In order to prevent a transponder channel overlapping with a
reader channel, we recommend that the Dense Reader Mode (DRM) is used.
1.2.2.2
Antenna/read point configurations
You can connect up to two external antennas to the RF630R reader. You have 3 possibilities
for aligning the antennas and covering the read point.
One RF630R reader with two antennas and two read points
If you connect two external antennas to the device and align them in different directions, you
can read tags at two different read points. With this technique, a particular antenna must be
switched off application-dependently to be able to establish which tags have been read from
which antenna. The reader also provides a mode for this purpose in which the antennas can
be switched on and off cyclically (both antennas must be connected). Note the minimum
distances between the antennas for the antenna configuration (see Chapter Specified
minimum and maximum spacing of antennas (Page Fehler! Textmarke nicht definiert.) .
One RF630R reader with two antennas and one read point
If you connect two external antennas to the device and align them in the same direction
(portal configuration), you can read tags at one read point. With this method, the reader
automatically switches between the two antennas while the tags are being read. Note the
minimum distances between the antennas for the antenna configuration (see Chapter
Specified minimum and maximum spacing of antennas (Page Fehler! Textmarke nicht
definiert.) .
One RF630R reader with one antenna and one read point
If you connect an external antenna to the device, you can read tags at one read point.
1.2.3
Installing/Mounting
Requirement
WARNING
Ensure that the wall or ceiling can hold four times the total weight of the device.
Mounting/installing the device
You can mount the reader directly onto a flat surface.
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
27
Readers
1.2 RF630R reader
The positions of the fixing holes for the device are shown in the section Dimension drawings
(Page 32).
1.2.4
Configuration/integration
1.2.4.1
Configuration
The RS422 system interface is provided for integrating the device into system
environments/networks. The system interface transfers the data to SIMATIC controllers or
PCs with the appropriate interface.
Apart from transmitting communication data from the reader to the controller and vice versa,
the RS422 interface also supplies power to the reader (24 V DC).
6,0$7,&6
6,0$7,&5)$
6,0$7,&5)$
3URILEXV
3URILQHW
5)5
56'&9
5)&
Figure 1-5
5)& $60
Overview of configuration of the RF630R reader
The RF620R reader can alternatively be connected to a SIMATIC controller via the ASM
456, RF170C or RF180C interface modules/communication modules.
For further details on the interface modules used, see Chapter RF660R (Page Fehler!
Textmarke nicht definiert.) .
Further information about commissioning the readers can be found in the Configuration
Manual "RF620R/RF630R" in the "Commissioning" section.
28
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.2 RF630R reader
1.2.4.2
Transmission protocols
RS 422 communication
3964R protocol
Transmission rates
19.2 Kbaud/s
57.6 Kbaud
115,2 Kbaud/s
Start bits
Data bits
Parity
Odd
Stop bits
1.2.5
Technical data
1.2.5.1
Mechanical data
Mechanical data
Weight
1640 g
Dimensions (L x W x H) in mm
252 x 193 x 52 mm, without connections
Material for housing top section
ABS (GF 20)
Material for housing bottom section
Aluminum
Color of housing top section
Anthracite
Color of housing bottom section
Silver
Status displays on the device
1 LED
Colors: Red, yellow, green
Interfaces
Antenna connections
2x RTNC plug
RS422
1 x plug (8-pin M12)
Software
SIMATIC S7
Technical properties
MTBF (Mean Time Between Failures)
16 years
Supply voltage
Current consumption
Current consumption
(in standby mode, no
transmit power)
(in standby mode, no
transmit power)
20 V input voltage on the reader, typical
135 mA
2.7 W
24 V input voltage on the reader, typical
115 mA
2.76 W
30 V input voltage on the reader, typical
95 mA
2.85 W
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
29
Readers
1.2 RF630R reader
Supply voltage
Current consumption
Power requirement
(at 500 mW ERP)
(at 500 mW ERP)
20 V input voltage on the reader, typical
470 mA
9.4 W
24 V input voltage on the reader, typical
395 mA
9.48 W
30 V input voltage on the reader, typical
320 mA
9.6 W
Rampup time
7s
Mechanical environmental conditions
Shock resistant to EN 60068-2-27
Vibration EN 60068-2-6
50 g1
20 g1
Climatic Conditions
Ambient temperature during operation
-25 °C to +55 °C (warm-up time of 10 minutes must be
observed)
Ambient temperature for transport and storage
-40 °C to +85 °C
EMC & approvals for ETSI variant
Electromagnetic compatibility
ETSI EN 301 489-1 / -3
ETSI EN 302 208
Approvals
•
•
•
•
•
Radio to R&TTE- guidelines EN 300 330, EN 301 489
CE
ETSI EN 302-208 V1.1.2
ETSI EN 302-208 V1.2.1
Reader degree of protection acc. to EN 60529 (IP65)
The values for shock and vibration are maximum values and must not be applied
continuously.
1)
1.2.5.2
Technical data according to EPC and ISO
Technical data
Frequency accuracy
max.Âą 10 ppm
Channel spacing
EU, EFTA, Turkey: 200 kHz
US: 500 kHz
China: 250 kHz
Modulation methods
ASK: DSB modulation & PR-ASK modulation
Encoding, Manchester or Pulse Interval (PIE)
Effective radiant power
(the radiant power depends on the antennas and cables
used, see Guidelines for selecting RFID UHF antennas
(Page Fehler! Textmarke nicht definiert.) )
30
≤ 0.5 W ERP
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.2 RF630R reader
ETSI frequencies
Frequency bands for EU, EFTA, Turkey:
865 to 868 MHz (10 subchannels LBT at 2 W ERP, 12
subchannels at 0.5 W ERP, 15 subchannels LBT at 0.1 W
ERP)
Read distance for EU, EFTA, Turkey / China
Antennas mounted on opposing sides
(portal configuration)
Antennas mounted on the same side
1.2.5.3
max. 3.5 m (recommended maximum value for
configuration)
Max. 2 m (recommended maximum value for configuration;
depending on the transponder)
Maximum number of readable tags
The maximum number of readable tags depends on the following parameters:
● Size of the antenna field
● Readability of the tags
For a transmit power of 500 mW ERP, the following is read when the tag RF620T is used:
● Max. 40 tags in the antenna field (tags perpendicular to antenna and 1 m in front)
● Max. 18 tags per second
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
31
Readers
1.2 RF630R reader
Dimension drawings

1.2.6
ࡘ






Figure 1-6
Dimension drawing for RF630R
All dimensions in mm
1.2.7
Certificates and approvals
Certificate
Description
CE Approval to R&TTE
32
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
Readers
1.3 FCC Information
1.2.8
Certificates RF630R (FCC)
Tabelle 1- 5
6GT2811-4AA00-1AA0
Norm
FCC CFR 47, Part 15 sections 15.247
Federal Communications
Commission
Industry Canada Radio
Standards Specifications
Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
FCC ID: NXW-RF630
RSS-210 Issue 7, June 2007, Sections 2.2, A8
IC: 267X-RF630
Dieses Produkt ist nach UL fĂźr USA und Canada zertifiziert.
Es erfĂźllt folgende Standard(s) for Safety:
UL 60950-1 - Information Technology Equipment Safety - Part 1:
General Requirements
CSA C22.2 No. 60950 -1 - Safety of Information Technology
Equipment
UL Report E 205089
1.3
FCC Information
Siemens SIMATIC RF630R (FCC): 6GT2811-4AA00-1AA0
FCC ID: NXW-RF630
This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
FCC NoticeTo comply with FCC part 15 rules in the United States, the system must be
professionally installed to ensure compliance with the Part 15 certification.
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018
33
Readers
1.4 IC-FCB Information
It is the responsibility of the operator and professional installer to ensure that only certified
systems are deployed in the United States. The use of the system in any other combination
(such as co-located antennas transmitting the same information) is expressly forbidden.
FCC Exposure InformationTo comply with FCC RF exposure compliance requirements, the
antennas used for this transmitter must be installed to provide a separation distance of at
least 20 cm from all persons and must not be co-located or operating in conjunction with any
other antenna or transmitter.
1.4
IC-FCB Information
Siemens SIMATIC RF630R (FCC): 6GT2811-4AA00-1AA0
IC: 267X-RF630
Industry Canada NoticeTo reduce potential radio interference to other users, the antenna
type and its gain should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that permitted for successful communication.
This device has been designed to operate with the SIMATIC RF660A antenna 902-928 listed
below, and having a maximum gain of 5,5 dBi.
Other antennas or antennas having a gain greater than 5,5 dBi are strictly prohibited for use
with this device.
The required antenna impedance is 50 Ohms
34
SIMATIC RF600
System Manual, 11/2008, J31069-D0171-U001-A6-0018


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-702
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2009:03:10 15:42:56+01:00
Create Date                     : 2009:03:05 16:21:33+01:00
Metadata Date                   : 2009:03:10 15:42:56+01:00
Format                          : application/pdf
Title                           : Microsoft Word - System_Manual_RF600_en.doc
Creator                         : ADTASV0
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Document ID                     : uuid:b849a95b-0f03-411f-b762-459685ba2639
Instance ID                     : uuid:5b470470-6795-46b0-800e-b2e3f0878051
Has XFA                         : No
Page Count                      : 32
Author                          : ADTASV0
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NXW-RF620R

Navigation menu