Siemens RF620R UHF RFID READER User Manual System Manual RF600 en
Siemens AG UHF RFID READER System Manual RF600 en
Siemens >
User Manual
Table of contents 1.1 1.1.1 1.1.1.1 1.1.1.2 1.1.1.3 1.1.1.4 1.1.1.5 1.1.2 1.1.2.1 1.1.2.2 1.1.2.3 1.1.3 1.1.4 1.1.4.1 1.1.5 1.1.5.1 1.1.5.2 1.1.5.3 1.1.6 1.1.7 RF620R reader ..............................................................................................................................7 Description .....................................................................................................................................7 Ordering data .................................................................................................................................8 Status display.................................................................................................................................9 Pin assignment of the RS422 interface .......................................................................................10 Pin assignment of the connecting cable ......................................................................................10 Grounding connection..................................................................................................................11 Planning application.....................................................................................................................11 Minimum mounting clearances of two readers ............................................................................11 Antenna diagram for RF620R (ETSI) ..........................................................................................12 Antenna/read point configurations ...............................................................................................15 Installing/Mounting .......................................................................................................................15 Configuration/integration..............................................................................................................16 Transmission protocols ................................................................................................................17 Technical data..............................................................................................................................17 Mechanical data ...........................................................................................................................17 Technical data according to EPC and ISO ..................................................................................18 Maximum number of readable tags .............................................................................................19 Dimension drawings.....................................................................................................................20 Certificates and approvals ...........................................................................................................20 1.2.1 1.2.1.1 1.2.1.2 1.2.1.3 1.2.1.4 1.2.1.5 1.2.2 1.2.2.1 1.2.2.2 1.2.3 1.2.4 1.2.4.1 1.2.4.2 1.2.5 1.2.5.1 1.2.5.2 1.2.5.3 1.2.6 1.2.7 21 Description ...................................................................................................................................22 Ordering data ...............................................................................................................................23 Status display...............................................................................................................................24 Pin assignment of the RS422 interface .......................................................................................25 Pin assignment of the connecting cable ......................................................................................25 Grounding connection..................................................................................................................26 Planning application.....................................................................................................................26 Minimum mounting clearances of two antennas of different readers ..........................................26 Antenna/read point configurations ...............................................................................................27 Installing/Mounting .......................................................................................................................27 Configuration/integration..............................................................................................................28 Configuration................................................................................................................................28 Transmission protocols ................................................................................................................29 Technical data..............................................................................................................................29 Mechanical data ...........................................................................................................................29 Technical data according to EPC and ISO ..................................................................................30 Maximum number of readable tags .............................................................................................31 Dimension drawings.....................................................................................................................32 Certificates and approvals ...........................................................................................................32 SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 1 Readers 1.1 RF620R reader 1.1.1 Description The SIMATIC RF620R is an active stationary reader in the UHF frequency range with an integrated circular polarized antenna. The SIMATIC RF620R is connected to a SIMATIC S7 controller via an ASM interface module. The degree of protection corresponds to IP 65. SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Item Description (1) LED operating indicator (2) RS 422 interface (8-pin M12 socket) Readers 1.1 RF620R reader Highlights â The tags are read in accordance with the requirements of the EPCglobal Class 1, Gen 2 and ISO/IEC 18000-6C standards â Supports low-cost SmartLabels as well as reusable, rugged data media â High reading speed: Depending on the function block (multitag mode), many tags can be detected simultaneously (bulk reading), rapidly moving tags are reliably acquired. â The RF620R (ETSI) "6GT2811-5BA00-0AA0" is suitable for the frequency band 865 to 868 MHz UHF (EU, EFTA, Turkey). â IP65 degree of protection for reader â Can be used for a high temperature range â Dense Reader Mode (DRM) for environments in which many readers are operated in close proximity to each other â TIA system interface: â RS 422 1.1.1.1 Ordering data Device Order No. RF620R (ETSI) reader basic unit for EU, EFTA, Turkey 6GT2811-5BA00-0AA0 Accessories Description Order No. RS 422, M12 plug, 8-pin socket: 2 m 6GT289-0FH20 RS 422, M12 plug, 8-pin socket: 5 m 6GT289-0FH50 RS 422, M12 plug, 8-pin socket: 10 m 6GT289-0FN10 RS 422, M12 plug, 8-pin socket: 20 m 6GT289-0FN20 RS 422, M12 plug, 8-pin socket: 50 m 6GT289-0FN50 Antenna mounting kit Standard 6GT2890-0AA00 Software & Documentation CD-ROM 6GT2080-2AA10 Connecting cable SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.1 RF620R reader 1.1.1.2 Status display The device is equipped with a three colored LED. The LED can be lit in green, red or yellow. The meaning of the indication changes in accordance with the color and state (on, off, flashing) of the LED: Green LED Red LED Yellow LED Meaning Off Off Off The device is starting up. Flashing Off Off The device is ready. The antenna is switched off. On Off Off The device is ready. The antenna is switched on. Off Off On "With presence": At least one tag is in the field. "Without presence": Communication with a tag is active. Off Flashing Off Reader is not active, a serious error has occurred. In addition, this LED also indicates the fault status through the number of flashing pulses. Reboot (operating voltage Off â On is necessary). The LED flashes once for the 'INACTIVE' status, rebooting is not necessary in this case. For more detailed information on the flash codes of the reader see Chapter Error messages and flash codes for RF620R/RF630R (Page Fehler! Textmarke nicht definiert.) Note LED not lit yellow? If the LED does not light up yellow even though a tag is located within the field, common causes are: ⢠Incorrect configuration in the init_run command, or init_run command was not executed (see "Configuration Manual RF620R/RF630R") ⢠Antenna is switched off ⢠A tag is used, that is not compatible with the reader protocol (EPC Global Class 1 Gen 2). ⢠Tag is defective ⢠Reader or antenna has a defect ⢠Tag is not in the field of radiation of the transmit antenna SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.1 RF620R reader 1.1.1.3 Pin assignment of the RS422 interface Pin Pin Device end 8-pin M12 Assignment + 24 V - Transmit 0V + Transmit + Receive - Receive Free Earth (shield) The knurled bolt of the M12 plug is not connected to the shield (on the reader side). Note You must therefore not use any SIMATIC connecting cables that use the angled M12 plug. 1.1.1.4 Pin assignment of the connecting cable Table 1- 1 10 RS 422 - on reader side M12 pin Core color Pin assignment white 24 V DC brown TX neg green GND yellow TX pos Gray RX pos pink RX neg blue Not used red Earth (shield) View of M12 connector SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.1 RF620R reader Note This cable has an 8-pin M12 connector at one end and the other cable end is 'open'. There are 8 color-coded single cores there for connecting to external devices. There are different cable lengths in the product range (3 m to 50 m). Long cables can be reduced if necessary. Note For long cables: Adapt supply voltage and data rate accordingly Note that with long cables in particular, the supply voltage of 24 V DC must always be applied. Note also that the data rate on the serial interface must, if necessary, be reduced. (See "Configuration Manual RF620R/RF630R") 1.1.1.5 Grounding connection The RF620R/RF630R can be electrically connected to the ground potential through a contact washer. The tightening torque must be increased in this case to ensure that electrical contact is made (2.7 Nm). Ground connection (a) Hexagon-head screw (b) Plain washer (c) Cable lugs (d) Contact washer: Use contact washers according to the Siemens standard SN 70093-6-FSt-flNnnc480h for ground connection, Siemens item No.: H70093-A60-Z3 1.1.2 Planning application 1.1.2.1 Minimum mounting clearances of two readers The RF620R has a circular polarized antenna. At 500 mW ERP radiated power, due to the opening angle of the antennas, their fields can overlap considerably. It is no longer possible to clarify in which antenna field access to the data of a tag is performed. In order to avoid this, always keep a minimum distance of 3 m between two readers with the maximum radiated power of 500 mW ERP. SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 11 Readers 1.1 RF620R reader Dense Reader Mode (DRM) The readers can also interfere with each other (secondary fields), if the channels (Reader TX, Transponder TX) overlap. In order to prevent a transponder channel overlapping with a reader channel, we recommend that the Dense Reader Mode (DRM) is used. 1.1.2.2 Antenna diagram for RF620R (ETSI) The following radiation diagrams show the directional radiation pattern of the internal antenna of the RF620R (ETSI) reader. For the spatial presentation of the directional radiation pattern, the vertical plane in space (Azimuth section) as well as the horizontal plane (elevation section) must be considered. This results in a spatial image of the directional radiation pattern of the antenna with its main and auxiliary fields. $]LPXW;= (OHYDWLRQ<= 12 SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.1 RF620R reader Radiation diagram (Azimuth section) Vertical component of the polarization direction of the antenna Horizontal component of the polarization direction of the antenna Figure 1-1 Azimuth section SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 13 Readers 1.1 RF620R reader Radiation diagram (elevation section) Vertical component of the polarization direction of the antenna Horizontal component of the polarization direction of the antenna Figure 1-2 14 Elevation section SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.1 RF620R reader Overview of the antenna parameters Table 1- 2 Maximum linear electrical opening angle at 865 MHz: Azimuth section 77,7° Elevation section 66,1° Typical antenna gain in the frequency range 865 to 868 MHz 7,3 dBic Antenna axis ratio 0,7 dB See also Chapter Guidelines for selecting RFID UHF antennas (Page Fehler! Textmarke nicht definiert.) 1.1.2.3 Antenna/read point configurations The RF620R reader has an internal circular polarized antenna. You can cover one read point with this antenna. When several RF620R readers are used, the readers are addressed via the SIMATIC level. 1.1.3 Installing/Mounting Requirement WARNING Ensure that the wall or ceiling can hold four times the total weight of the device. Mounting/installing the device You can mount the reader in two different ways: â Via a standardized VESA 100 mounting system using the Antenna Mounting Kit (see Chapter Mounting with antenna mounting kit (Page Fehler! Textmarke nicht definiert.)) â Directly onto a flat surface. The positions of the fixing holes for the device are shown in the section Dimension drawings (Page 20). SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 15 Readers 1.1 RF620R reader 1.1.4 Configuration/integration The RS422 system interface is provided for integrating the device into system environments/networks. The system interface transfers the data to SIMATIC controllers or PCs with the appropriate interface. Apart from transmitting communication data from the reader to the controller and vice versa, the RS422 interface also supplies power to the reader (24 V DC). 6,0$7,&6 3URILEXV 3URILQHW 5)5 56'&9 5)& Figure 1-3 5)& $60 Overview of configuration of the RF620R reader The RF620R reader can alternatively be connected to a SIMATIC controller via the ASM 456, RF170C or RF180C interface modules/communication modules. For further details on the interface modules used, see Chapter RF660R (Page Fehler! Textmarke nicht definiert.) . Further information about commissioning the readers can be found in the configuration manual "RF620R/RF630R" in the "Commissioning" section. 16 SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.1 RF620R reader 1.1.4.1 Transmission protocols RS 422 communication 3964R protocol Transmission rates 19.2 Kbaud/s 57.6 Kbaud 115,2 Kbaud/s Start bits Data bits Parity Odd Stop bits 1.1.5 Technical data 1.1.5.1 Mechanical data Mechanical data Weight 1850 g Dimensions (L x W x H) in mm 252 X 193 x 52 mm, without connections Material for housing top section ABS (GF 20) Material for housing bottom section Aluminum Color of housing top section Pastel turquoise Color of housing bottom section Silver Status displays on the device 1 LED Colors: Red, yellow, green Interfaces RS422 1 x plug (8-pin M12) Software SIMATIC S7 Technical properties MTBF (Mean Time Between Failures) 16 years Supply voltage Current consumption (in standby mode, no transmit power) Power consumption (in standby mode, no transmit power) 20 V input voltage on the reader, typical 135 mA 2.7 W 24 V input voltage on the reader, typical 115 mA 2.76 W 30 V input voltage on the reader, typical 95 mA 2.85 W Current consumption (at 500 mW ERP) Power requirement (at 500 mW ERP) 470 mA 9.4 W Supply voltage 20 V input voltage on the reader, typical SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 17 Readers 1.1 RF620R reader 24 V input voltage on the reader, typical 395 mA 9.48 W 30 V input voltage on the reader, typical 320 mA 9.6 W Ramp-up time, typical 7s Mechanical environmental conditions Shock resistant to EN 60068-2-27 Vibration EN 60068-2-6 50 g1 20 g1 Climatic Conditions Ambient temperature during operation -25 °C to +55 °C (warm-up time of 10 minutes must be observed) Ambient temperature for transport and storage -40 °C to +85 °C EMC & approvals RF620R (ETSI) Electromagnetic compatibility ETSI EN 301 489-1 / -3 ETSI EN 302 208 Approvals ⢠⢠⢠⢠⢠Radio to R&TTE- guidelines EN 300 330, EN 301 489 CE ETSI EN 302-208 V1.1.2 ETSI EN 302-208 V1.2.1 Reader degree of protection acc. to EN 60529 (IP65) The values for shock and vibration are maximum values and must not be applied continuously. 1) 1.1.5.2 Technical data according to EPC and ISO Technical data Frequency accuracy max.Âą 10 ppm Channel spacing EU: 200 kHz US: 500 kHz China: 250 kHz Modulation methods ASK: DSB modulation & PR-ASK modulation Encoding, Manchester or Pulse Interval (PIE) Effective Radiant Power (the radiant power depends on the antennas and cables used, see Guidelines for selecting RFID UHF antennas (Page Fehler! Textmarke nicht definiert.) ) ⤠0.5 W ERP ETSI frequencies Frequency bands for EU, EFTA, Turkey: 18 865 to 868 MHz (10 subchannels LBT at 2 W ERP, 12 subchannels at 0.5 W ERP, 15 subchannels LBT at 0.1 W ERP) SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.1 RF620R reader Read distance for EU, EFTA, Turkey / China Readers mounted on the same side 1.1.5.3 Max. 2 m (recommended maximum value for configuration; depending on the transponder) Maximum number of readable tags The maximum number of readable tags depends on the following parameters: â Size of the antenna field â Readability of the tags For a transmit power of 500 mW ERP, the following is read when the tag RF620T is used: â Max. 40 tags in the antenna field (tags perpendicular to antenna and 1 m in front) â Max. 18 tags per second SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 19 Readers 1.1 RF620R reader Dimension drawings 1.1.6 ࡠFigure 1-4 Dimension drawing for RF620R All dimensions in mm 1.1.7 Certificates and approvals Certificate Description CE Approval to R&TTE 20 SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.1 RF620R reader 1.1.8 Certificates RF620R (FCC) Tabelle 1- 3 6GT2811-5BA00-1AA0 Norm FCC CFR 47, Part 15 sections 15.247 Federal Communications Commission Industry Canada Radio Standards Specifications Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. FCC ID: NXW-RF620R RSS-210 Issue 7, June 2007 ,Sections 2.2, A8 IC: 267X-RF620R Dieses Produkt ist nach UL fĂźr USA und Canada zertifiziert. Es erfĂźllt folgende Standard(s) for Safety: UL 60950-1 - Information Technology Equipment Safety - Part 1: General Requirements CSA C22.2 No. 60950 -1 - Safety of Information Technology Equipment UL Report E 205089 1.1.9 FCC Information Siemens SIMATIC RF620R (FCC): 6GT2811-5BA00-1AA0 FCC ID: NXW-RF620R This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 21 Readers 1.2 RF630R reader FCC Notice To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden. FCC Exposure Information To comply with FCC RF exposure compliance requirements, the RF620R Reader (antenna and transmitter) must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. 1.2 RF630R reader 1.2.1 Description The SIMATIC RF630R is an active stationary reader in the UHF frequency range without an integrated antenna. Up to two external UHF RFID antennas can be connected via TNC reverse connections. The maximum HF power output is 0.5 W on the reader output. The SIMATIC RF630R is connected to a SIMATIC S7 controller via an ASM interface module. The degree of protection is IP65. 22 Item Description (1) TNCreverse interface for connection of antenna 1 (ANT 1) (2) TNCreverse interface for connection of antenna 2 (ANT 2) (2) LED operating indicator (3) RS 422 interface (8-pin M12 connector) SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.2 RF630R reader Highlights â The tags are read in accordance with the requirements of the EPCglobal Class 1, Gen 2 and ISO/IEC 18000-6C standards â Supports low-cost SmartLabels as well as reusable, rugged data media â High reading speed: Depending on the function block (multitag mode), many tags can be detected simultaneously (bulk reading), rapidly moving tags are reliably acquired. â The RF630R (ETSI) "6GT2811-4AA00-0AA0" is suitable for the frequency band 865 to 868 MHz UHF (EU, EFTA, Turkey). â Up to 2 external antennas can be connected and configured in operating mode â IP65 degree of protection for reader â Can be used for a high temperature range â Dense Reader Mode (DRM) for environments in which many readers are operated in close proximity to each other â TIA system interface: â RS 422 1.2.1.1 Ordering data Device Order No. RF630R (ETSI) reader basic unit for EU, EFTA, Turkey 6GT2811-4AA00-0AA0 RF660A antennas for EU, EFTA, Turkey (868 MHz) 6GT2812-0AA00 Accessories Antenna cable Connecting cable Software & Documentation Description Order No. 3 m (cable attenuation: 1,0 dB) 6GT2815-0BH30 10 m (cable attenuation: 4,0 dB) 6GT2815-0BN10 20 m (cable attenuation: 4,0 dB) 6GT2815-0BN20 RS 422, M12 plug, 8-pin socket: 2 m 6GT289-0FH20 RS 422, M12 plug, 8-pin socket: 5 m 6GT289-0FH50 RS 422, M12 plug, 8-pin socket: 10 m 6GT289-0FN10 RS 422, M12 plug, 8-pin socket: 20 m 6GT289-0FN20 RS 422, M12 plug, 8-pin socket: 50 m 6GT289-0FN50 RFID CD-ROM 6GT2080-2AA10 SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 23 Readers 1.2 RF630R reader 1.2.1.2 Status display The device is equipped with a three colored LED. The LED can be lit in green, red or yellow. The meaning of the indication changes in accordance with the color and state (on, off, flashing) of the LED: Green LED Red LED Yellow LED Meaning Off Off Off The device is starting up. Flashing Off Off The device is ready. The antenna is switched off. On Off Off The device is ready. The antenna is switched on. Off Off On "With presence": At least one tag is in the field. "Without presence": Communication with a tag is active. Off Flashing Off Reader is not active, a serious error has occurred. In addition, this LED also indicates the fault status through the number of flashing pulses. Reboot (operating voltage Off â On is necessary). The LED flashes once for the 'INACTIVE' status, rebooting is not necessary in this case. For more detailed information on the flash codes of the reader see Chapter Error messages and flash codes for RF620R/RF630R (Page Fehler! Textmarke nicht definiert.) Note LED not lit yellow? If the LED does not light up yellow even though a tag is located within the field, common causes are: ⢠Incorrect configuration in the init_run command, or init_run command was not executed (see "Configuration Manual RF620R/RF630R") ⢠Antenna is switched off ⢠A tag is used, that is not compatible with the reader protocol (EPC Global Class 1 Gen 2). ⢠Tag is defective ⢠Reader or antenna has a defect ⢠Tag is not in the field of radiation of the transmit antenna 24 SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.2 RF630R reader 1.2.1.3 Pin assignment of the RS422 interface Pin Pin Device end 8-pin M12 Assignment + 24 V - Transmit 0V + Transmit + Receive - Receive Free Earth (shield) The knurled bolt of the M12 plug is not connected to the shield (on the reader side). Note You must therefore not use any SIMATIC connecting cables that use the angled M12 plug. 1.2.1.4 Pin assignment of the connecting cable Table 1- 4 RS 422 - on reader side M12 pin Core color Pin assignment white 24 V DC brown TX neg green GND yellow TX pos Gray RX pos pink RX neg blue Not used red Earth (shield) SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 View of M12 connector 25 Readers 1.2 RF630R reader Note This cable has an 8-pin M12 connector at one end and the other cable end is 'open'. There are 8 color-coded single cores there for connecting to external devices. There are different cable lengths in the product range (3 m to 50 m). Long cables can be reduced if necessary. Note For long cables: Adapt supply voltage and data rate accordingly Note that with long cables in particular, the supply voltage of 24 V DC must always be applied. Note also that the data rate on the serial interface must, if necessary, be reduced. (See "Configuration Manual RF620R/RF630R") 1.2.1.5 Grounding connection The RF620R/RF630R can be electrically connected to the ground potential through a contact washer. The tightening torque must be increased in this case to ensure that electrical contact is made (2.7 Nm). Ground connection (a) Hexagon-head screw (b) Plain washer (c) Cable lugs (d) Contact washer: Use contact washers according to the Siemens standard SN 70093-6-FSt-flNnnc480h for ground connection, Siemens item No.: H70093-A60-Z3 1.2.2 Planning application 1.2.2.1 Minimum mounting clearances of two antennas of different readers At 500 mW ERP radiated power, due to the opening angle of the antennas, their fields can overlap considerably. It is no longer possible to clarify in which antenna field access to the data of a tag is performed. In order to avoid this, always keep a minimum distance of 3 m between two antennas of different RF630R readers with the maximum radiated power of 500 mW ERP. 26 SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.2 RF630R reader Dense Reader Mode (DRM) The readers can also interfere with each other (secondary fields), if the channels (Reader TX, Transponder TX) overlap. In order to prevent a transponder channel overlapping with a reader channel, we recommend that the Dense Reader Mode (DRM) is used. 1.2.2.2 Antenna/read point configurations You can connect up to two external antennas to the RF630R reader. You have 3 possibilities for aligning the antennas and covering the read point. One RF630R reader with two antennas and two read points If you connect two external antennas to the device and align them in different directions, you can read tags at two different read points. With this technique, a particular antenna must be switched off application-dependently to be able to establish which tags have been read from which antenna. The reader also provides a mode for this purpose in which the antennas can be switched on and off cyclically (both antennas must be connected). Note the minimum distances between the antennas for the antenna configuration (see Chapter Specified minimum and maximum spacing of antennas (Page Fehler! Textmarke nicht definiert.) . One RF630R reader with two antennas and one read point If you connect two external antennas to the device and align them in the same direction (portal configuration), you can read tags at one read point. With this method, the reader automatically switches between the two antennas while the tags are being read. Note the minimum distances between the antennas for the antenna configuration (see Chapter Specified minimum and maximum spacing of antennas (Page Fehler! Textmarke nicht definiert.) . One RF630R reader with one antenna and one read point If you connect an external antenna to the device, you can read tags at one read point. 1.2.3 Installing/Mounting Requirement WARNING Ensure that the wall or ceiling can hold four times the total weight of the device. Mounting/installing the device You can mount the reader directly onto a flat surface. SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 27 Readers 1.2 RF630R reader The positions of the fixing holes for the device are shown in the section Dimension drawings (Page 32). 1.2.4 Configuration/integration 1.2.4.1 Configuration The RS422 system interface is provided for integrating the device into system environments/networks. The system interface transfers the data to SIMATIC controllers or PCs with the appropriate interface. Apart from transmitting communication data from the reader to the controller and vice versa, the RS422 interface also supplies power to the reader (24 V DC). 6,0$7,&6 6,0$7,&5)$ 6,0$7,&5)$ 3URILEXV 3URILQHW 5)5 56'&9 5)& Figure 1-5 5)& $60 Overview of configuration of the RF630R reader The RF620R reader can alternatively be connected to a SIMATIC controller via the ASM 456, RF170C or RF180C interface modules/communication modules. For further details on the interface modules used, see Chapter RF660R (Page Fehler! Textmarke nicht definiert.) . Further information about commissioning the readers can be found in the Configuration Manual "RF620R/RF630R" in the "Commissioning" section. 28 SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.2 RF630R reader 1.2.4.2 Transmission protocols RS 422 communication 3964R protocol Transmission rates 19.2 Kbaud/s 57.6 Kbaud 115,2 Kbaud/s Start bits Data bits Parity Odd Stop bits 1.2.5 Technical data 1.2.5.1 Mechanical data Mechanical data Weight 1640 g Dimensions (L x W x H) in mm 252 x 193 x 52 mm, without connections Material for housing top section ABS (GF 20) Material for housing bottom section Aluminum Color of housing top section Anthracite Color of housing bottom section Silver Status displays on the device 1 LED Colors: Red, yellow, green Interfaces Antenna connections 2x RTNC plug RS422 1 x plug (8-pin M12) Software SIMATIC S7 Technical properties MTBF (Mean Time Between Failures) 16 years Supply voltage Current consumption Current consumption (in standby mode, no transmit power) (in standby mode, no transmit power) 20 V input voltage on the reader, typical 135 mA 2.7 W 24 V input voltage on the reader, typical 115 mA 2.76 W 30 V input voltage on the reader, typical 95 mA 2.85 W SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 29 Readers 1.2 RF630R reader Supply voltage Current consumption Power requirement (at 500 mW ERP) (at 500 mW ERP) 20 V input voltage on the reader, typical 470 mA 9.4 W 24 V input voltage on the reader, typical 395 mA 9.48 W 30 V input voltage on the reader, typical 320 mA 9.6 W Rampup time 7s Mechanical environmental conditions Shock resistant to EN 60068-2-27 Vibration EN 60068-2-6 50 g1 20 g1 Climatic Conditions Ambient temperature during operation -25 °C to +55 °C (warm-up time of 10 minutes must be observed) Ambient temperature for transport and storage -40 °C to +85 °C EMC & approvals for ETSI variant Electromagnetic compatibility ETSI EN 301 489-1 / -3 ETSI EN 302 208 Approvals ⢠⢠⢠⢠⢠Radio to R&TTE- guidelines EN 300 330, EN 301 489 CE ETSI EN 302-208 V1.1.2 ETSI EN 302-208 V1.2.1 Reader degree of protection acc. to EN 60529 (IP65) The values for shock and vibration are maximum values and must not be applied continuously. 1) 1.2.5.2 Technical data according to EPC and ISO Technical data Frequency accuracy max.Âą 10 ppm Channel spacing EU, EFTA, Turkey: 200 kHz US: 500 kHz China: 250 kHz Modulation methods ASK: DSB modulation & PR-ASK modulation Encoding, Manchester or Pulse Interval (PIE) Effective radiant power (the radiant power depends on the antennas and cables used, see Guidelines for selecting RFID UHF antennas (Page Fehler! Textmarke nicht definiert.) ) 30 ⤠0.5 W ERP SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.2 RF630R reader ETSI frequencies Frequency bands for EU, EFTA, Turkey: 865 to 868 MHz (10 subchannels LBT at 2 W ERP, 12 subchannels at 0.5 W ERP, 15 subchannels LBT at 0.1 W ERP) Read distance for EU, EFTA, Turkey / China Antennas mounted on opposing sides (portal configuration) Antennas mounted on the same side 1.2.5.3 max. 3.5 m (recommended maximum value for configuration) Max. 2 m (recommended maximum value for configuration; depending on the transponder) Maximum number of readable tags The maximum number of readable tags depends on the following parameters: â Size of the antenna field â Readability of the tags For a transmit power of 500 mW ERP, the following is read when the tag RF620T is used: â Max. 40 tags in the antenna field (tags perpendicular to antenna and 1 m in front) â Max. 18 tags per second SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 31 Readers 1.2 RF630R reader Dimension drawings 1.2.6 ࡠFigure 1-6 Dimension drawing for RF630R All dimensions in mm 1.2.7 Certificates and approvals Certificate Description CE Approval to R&TTE 32 SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 Readers 1.3 FCC Information 1.2.8 Certificates RF630R (FCC) Tabelle 1- 5 6GT2811-4AA00-1AA0 Norm FCC CFR 47, Part 15 sections 15.247 Federal Communications Commission Industry Canada Radio Standards Specifications Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. FCC ID: NXW-RF630 RSS-210 Issue 7, June 2007, Sections 2.2, A8 IC: 267X-RF630 Dieses Produkt ist nach UL fĂźr USA und Canada zertifiziert. Es erfĂźllt folgende Standard(s) for Safety: UL 60950-1 - Information Technology Equipment Safety - Part 1: General Requirements CSA C22.2 No. 60950 -1 - Safety of Information Technology Equipment UL Report E 205089 1.3 FCC Information Siemens SIMATIC RF630R (FCC): 6GT2811-4AA00-1AA0 FCC ID: NXW-RF630 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC NoticeTo comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018 33 Readers 1.4 IC-FCB Information It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden. FCC Exposure InformationTo comply with FCC RF exposure compliance requirements, the antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. 1.4 IC-FCB Information Siemens SIMATIC RF630R (FCC): 6GT2811-4AA00-1AA0 IC: 267X-RF630 Industry Canada NoticeTo reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. This device has been designed to operate with the SIMATIC RF660A antenna 902-928 listed below, and having a maximum gain of 5,5 dBi. Other antennas or antennas having a gain greater than 5,5 dBi are strictly prohibited for use with this device. The required antenna impedance is 50 Ohms 34 SIMATIC RF600 System Manual, 11/2008, J31069-D0171-U001-A6-0018
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-702 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2009:03:10 15:42:56+01:00 Create Date : 2009:03:05 16:21:33+01:00 Metadata Date : 2009:03:10 15:42:56+01:00 Format : application/pdf Title : Microsoft Word - System_Manual_RF600_en.doc Creator : ADTASV0 Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:b849a95b-0f03-411f-b762-459685ba2639 Instance ID : uuid:5b470470-6795-46b0-800e-b2e3f0878051 Has XFA : No Page Count : 32 Author : ADTASV0EXIF Metadata provided by EXIF.tools