All rights reserved SIMATIC IPC427C
© Copyright Siemens AG 2013
1/5
Product Data Sheet
SIMATIC IPC427C
SIMATIC IPC427C (Microbox PC): The powerful embedded IPC
– maintenance-free with versatile configuration:
• Ultra-compact
• Maintenance-free
Intel Core2 Duo technology
Design
Basic design
All-metal enclosure, resistant to vibrations and shocks, also
with high electromagnetic compatibility
Graphics onboard, on AGP bus: DVI-I: VGA (analog) and
DVI (digital)
- CRT resolution: Up to 1920 x 1200 pixels / true color /
60 to 120 Hz
- DVI-D resolution: Up to 1920 x 1200 pixels / true color
Optical drives can be connected externally via USB interface,
not included in scope of supply
Interfaces (accessible from one side):
- 2 x LAN 10/100/1000 Mbit/s Ethernet interface (RJ45)
- 4 x high-speed USB V2.0
- 1 x COM1 (RS232)
Free slots (when using the expansion rack):
- Up to 3 x PCI104-Plus cards
Isolated power supply: 24 V DC (19.2 to 28.8 V)
Design versions
Processor:
- Intel Core2 Duo 1.2 GHz, 800 MHz FSB, SLC 3 MB
- Intel Core2 Solo 1.2 GHz, 800 MHz FSB, SLC 3 MB
- Intel Celeron M 1.2 GHz, 800 MHz FSB, SLC 1 MB
Primary storage capacity of 1 GB to (2/4 GB optional),
DDR3 SDRAM
Fieldbus
- PROFINET onboard, 3 x RJ45, CP16116-compatible
- PROFIBUS DP/MPI on board, compatible with CP 5611
Hardware expansion:
- Second RS232 interface (COM2) in expansion rack
Drives:
- Solid-State Drive 50 GB High Endurance or 80 GB Stan-
dard, rugged alternative to hard disk
- FlashDrive (replaceable, accessible): 2 GB, 4 GB, 8 GB or
16 GB
- FlashDrive (internal, not accessible): 2 GB, 4 GB, 8 GB,
16 GB
- Hard disk serial ATA, 2.5"
Pre installed operating systems:
- Windows XP Embedded Standard 2009
(successor to Windows XP Embedded)
- Windows XP Professional Multi-Language
- Windows 7 Ultimate MUI
- Windows Embedded Standard 7
SIMATIC IPC427C (bottom side), PROFIBUS version
SIMATIC IPC427C (bottom side), PROFINET version
© Siemens AG 2013
All rights reserved SIMATIC IPC427C
© Copyright Siemens AG 2013
2/5
Technical specifications Box PC SIMATIC IPC 427C
General features
Design DIN rail or wall mounting, front upright
mounting, mounting position preferably
horizontal, vertical possible
Processor • Intel Core2 Duo 1.2 GHz, 800 MHz
FSB, SLC 3 MB
• Intel Core2 Solo 1.2 GHz, 800 MHz
FSB, SLC 3 MB
• Intel Celeron M 1.2 GHz, 800 MHz
FSB, SLC 1 MB
Chipset Intel GM45 / ICH9M
Main memory 1 GB, (2/4 GB) DDR3 SDRAM
Buffered SRAM 2 MB, of which 128 KB can be written
within the buffer time
Free slots for expansions Up to 3 x PCI-104, 3 W per slot
Graphics Integrated Intel GMAX4500 graphics
• 8 ... 512 MB shared graphics
memory (managed dynamically)
CRT resolution: 640 x 480 pixels up to
max. 1920 x 1200 pixels at
32 bit colors
• DVI-D resolution: 640 x 480 pixels up
to max. 1920 x 1200 pixels at
32 bit colors
Operating system • Without
• Windows XP Embedded Standard
2009 preinstalled, in combination with
CF card of 2 GB or more, solid-state
drive, or hard drive
• Windows XP Professional MUI (in
combination with solid-state drive or
hard drive; MUI: Multi Language User
Interface)
• Windows 7 Ultimate MUI (in combina-
tion with solid-state drive or hard
drive; MUI: Multi Language User In-
terface)
• Windows Embedded Standard 7 pre-
installed, in combination with CF card
of 4 GB or more, or solid-sate drive, or
hard drive RMOS3 (can be ordered
separately)
•Linux
1)
(project-specific, on request)
• Others on request project-specifically
Power supply • 24 V DC (19.2 V ... 28.8 V)
• Isolated
• With buffering of temporary power
failures: Max. 10 ms at 0.85% rated
voltage
• Line side switch
• With power failure indication by
means of Power Fail signa
l
Drives
Flash drive Optional; replaceable, accessible,
diagnosable
•2 GB
•4GB
•8GB
•16 GB
Optional; internal, not accessible,
diagnosable
•2 GB
•4GB
•8GB
•16 GB
Solid-State Drive (SSD) Optional
• 50 GB SATA, 2.5" in single-level cell
(SLC) architecture (High Endurance),
especially suitable for industrial appli-
cations
• 80 GB SATA, 2.5" Standard
Hard disk Optional
> 250 GB SATA
CD-ROM Via USB (not included in scope of
delivery)
DVD-RW Via USB (not included in scope of
delivery)
Diskette Via USB (not included in scope of
delivery)
Interfaces
PROFINET 3 x RJ45 (CP 1616-compatible,
optional)
PROFIBUS/MPI 12 Mbit/s (isolated, compatible to
CP 5611) optional
Ethernet • 2 x 10/100/1000 Mbit/s (RJ 45)
• Two independent Intel 82574L
controllers (via PCI-Express)
• One controller with none-shared
interrupt
• With teaming function
USB V2.0/High Speed: 4 x
Serial COM1 (V.24)
COM2 (V.24) optional (in expansion
frame)
DVI-I 1 x DVI-I (includes DVI-D and VGA)
Keyboard Via USB (not included in scope of
delivery)
Mouse Via USB (not included in scope of
delivery)
© Siemens AG 2013
SIMATIC IPC427C All rights reserved
© Copyright Siemens AG 2013
3/5
Monitoring functions
Temperature Processor temperature
• Motherboard
• Messages can be evaluated by the
application program
Watchdog • Monitoring of program execution
• Monitoring time can be parameter-
ized in software
• Can be parameterized for a fault or
restart
• Messages can be evaluated by the
application program.
Monitoring functions via
the network •DiagBase
• SIMATIC PC DiagMonitor
Remote monitoring capability for:
• Watchdog
•Temperature
• Mass memory monitoring (SMART)
• System / Ethernet monitoring
(Heartbeat)
• Runtime meter
Communication:
• Ethernet interface (SNMP protocol)
• OPC for integration in SIMATIC soft-
ware
• Configuration of client/server archi-
tectures
• Layout of log files
Ambient conditions
Degree of protection to
EN 60529 (front/rear) IP20
Vibration load during
operation Devices without hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to: IEC 60068-2-6,
Test Fc
• Devices without drive:
- 5-9 Hz, 3.5 mm deviation, 10x /axis,
1 octave/min
- 9-150 Hz, 9.8 m/s
2
, 10x /axis,
1 octave/min
Devices with hard disk: Wall mounting
• Requirements according to:
IEC 61131-2
• Tested according to: IEC 60068-2-6,
Test Fc
• 10 ... 58 Hz, 0.0375 mm deviation,
10x /axis, 1 octave/min
• 58 ... 200 Hz, 4.9 m/s
2
, 10x /axis,
1 octave/min
Shock loading during
operation Devices without hard disk:
• Requirements according to:
IEC 61131-2
Tested according to: IEC 60068-2-27,
Test Ea
• Module/rack: 150 m/s
2
, power-up,
11 ms shock duration
Devices with hard disk: Wall mounting
• Requirements according to:
IEC 61131-2
Tested according to: IEC 60068-2-27,
Test Ea
• Devices with drive: 50 m/s
2
, power-
up, 30 ms shock duration
Electromagnetic
compatibility (EMC)
• Emitted interference EN 55022 Class B
• Interference immunity,
burst EN 61000-6-2 or IEC 61131-2:
• 2 kV - Tested acc. to IEC 61000-4-4
• 1 kV symmetrical / 2 kV asymmetrical
- Tested acc. to IEC 61000-4-5
• Interference immunity,
surge 1 kV to IEC 61000-4-5; symmetrical
2 kV to IEC 61000-4-5; asymmetrical
• ESD interference
immunity According to NAMUR Recommenda-
tion NE 21 and EN 61000-6-2:
• 6 kV contact discharge - Tested acc.
to IEC 61000-4-2
• 8 kV air discharge - Tested acc. to
IEC 61000-4-2
• Immunity to high radio
frequency interference According to EN 61000-6-2 or
IEC 61131-2:
• Interference immunity 80 ... 1000
MHz: 10 V/m with 80% AM (1 kHz);
tested acc. to IEC 61000-4-3;
• 1.4 GHz ... 2 Hz: 10 V/m with 50%
pulse modulation; tested according
to IEC 61000-4-3
• Immunity to high-fre-
quency current feed Acc. to NAMUR Recommendation NE
21 and EN 61000-6-2 or IEC 61131-2:
• 10 kHz ... 80 MHz: 10 V with 80% AM
(1 kHz) tested acc. to IEC 61000-4-6
• Immunity to magnetic
fields Acc. to NAMUR Recommendation NE
21 and EN 61000-6-2 or IEC 61131-2:
50/60 Hz; 100 A/m rms value - tested
acc. to IEC 61000-4-8
Ambient temperature dur-
ing operation • 0 ... 55 ºC with flash drive/SSD
(horizontal; preferred mounting
position; with derating)
• 0 ... 50 ºC with flash drive/SSD
(horizontal; preferred mounting
position; maximum configuration)
• 0 ... 50 ºC with flash drive/SSD
(vertical)
• 5 ... 40 ºC with hard disk (horizontal
and vertical)
Moist heat • With CompactFlash card/SSD: 95 %
• With hard drive 80%
© Siemens AG 2013
All rights reserved SIMATIC IPC427C
© Copyright Siemens AG 2013
4/5
1)
Suitable for specific LINUX versions in accordance with the specifica-
tions of the Siemens manufacturer’s declaration "Suitable for LINUX",
see http://www.siemens.de/simatic-pc/geeignet-fuer-linux (LINUX is a
trademark of Linus Torvald).
Dimensional drawings (dimensions in mm)
System-tested
SIMATIC Industrial
Software
WinAC RTX (F), WinCC flexible, WinCC
(SCADA as of V7.0), WinCC RT
Advanced and Professional
Approvals
Marine approval
Only for configurations
with CompactFlash or
SSD memory
• GL - Germanische Lloyd
• BV - Bureau Veritias
• LR - Lloyds Register of Shipping
• ABS - American Bureau of Shipping
• DNV - Det Norske Veritas
• NKK - Nippon Kaiji Kyokai
Safety regulations • IEC 61131-2
• IEC 61010-1
• EN 60950-1
Approvals UL508, UL60950, cULus
CE mark • EC Directive 89/336/EEC
(EMC Directive)
• Use in industry:
- Emitted interference: EN 61000-6-4
- Noise immunity: EN 61000-6-2
• Applications in residential areas,
business and trade environments as
well as in workshops:
- Emitted interference: EN 61000-6-3
- Noise immunity: EN 61000-6-1
Dimensions and
weights
Equipment dimensions
(in mm) • Width x height: 262 x 134
• Depth of basic unit: 47
• Depth of basic unit above rail: 50
Additional depth per expansion (1-3):
17 each
Weight, approx. 2 kg
46.5
*B67B;;B
133
138
262
52,5
97,5
G_ST80_XX_00456
262 138
© Siemens AG 2013
SIMATIC IPC427C All rights reserved
© Copyright Siemens AG 2013
5/5
SIMATIC IPC – the more Industrial PC
More information on SIMATIC IPC is available at: www.siemens.com/simatic-ipc
A current overview of the configurations is provided by the
SIMATIC IPC Online-Konfigurator:
www.siemens.com/ipc-configurator
In-depth information is available in the SIMATIC manuals: www.siemens.com/simatic-doku
Information material for download:
www.siemens.com/simatic/printmaterial
Technical documentation is available in our
Service& Support portal:
www.siemens.com/automation/support
Your personal contact partner is listed at: www.siemens.com/automation/partner
Electronic ordering via the Internet with the Mall: www.siemens.com/industrymall
Additional information on PC-based Automation with SIMATIC
is available under:
www.siemens.com/pc-based-automation
Additional information on the TIA Portal: www.siemens.com/tia-portal
Additional information on SIMATIC Safety Integrated: www.siemens.com/f-cpu
Online Service Tool PED – for fast information on the equipment
of your SIMATIC PC and the management of your field invento-
ry:
www.siemens.com/ped
© Siemens AG 2013

Navigation menu