Siemens VAS5053 Car Diagnostic System with Bluetooth User Manual 339 GB A01 2 VAS 5053 UL Abnahme

Siemens AG Car Diagnostic System with Bluetooth 339 GB A01 2 VAS 5053 UL Abnahme

User Manual

Vehicle Diagnostic and Service Informations systemVAS 5053Ausgabestand: 06.08.04, A01.3Operating Manual A01.3 08/04IBR 339
IMPORTANT SAFETY INSTRUCTIONSOperating Manual VAS 5053 A01.3 08/04 All rights reserved.iA5E00310438VAS 5053VAS 5051BVAS 5051VAS 5052Safety InstructionsMeaning of symbolsThe safety instructions in the Operating Manual, the Startup/Unpacking Instructions or in other documentation provided, on screen displays on the tester during operation and on the products themselves use symbols with the following meanings:The WARNING     symbol warrants particular attention for your safety.The Caution     symbol tells you that if the information is ignored, damage to the vehicle and/or the tester could result (e.g.: Ensure that the touchscreen is not touched with sharp, edged objects).A Note     symbol contains other, special instructions for using the device, and related information.Warning!Text with this symbol contains information for your safety and how you can reduce the risk of severe or fatal injury.Caution!Text with this symbol contains information about how you can avoid damage to the vehi-cle and the tester.NoteText with this symbol contains additional, useful information.NoteThe general safety instructions are listed in the following. Further instructions are to be found in the Operating Manual. Therefore read the Operating Manual before use.Safety instructions may also appear on the screen of the tester. Follow all the instruc-tions displayed.
IMPORTANT SAFETY INSTRUCTIONSOperating Manual VAS 5053 A01.3 08/04 All rights reserved.iiA5E00310438VAS 5053VAS 5051BVAS 5051VAS 5052IMPORTANT SAFETY INSTRUCTIONS1. Warning!Read all instructions.2. Warning!Do not operate equipment with a damaged cord or if the equipment has been damaged - until it has been examined by a qualified serviceman.3. Warning!Do not let cord hang over edge of table, bench or counter, or come in contact with hot manifolds or moving fan blades.4. Warning!An extension cord is not allowed. For testing use only specified cables.5. Warning!Always unplug equipment from electrical outlet when not in use. Never yank cord to pull plug from outlet. Grasp plug and pull to disconnect.6. Warning!To protect against risk of fire, do not operate equipment in the vicinity of open contai-ners of fuel (gasoline).Risk of explosionThis equipment has internal arcing or sparking parts wich should not be exposed to flammable vapour. This equipment should be located at least 460 mm (18 inches) above the floor.
IMPORTANT SAFETY INSTRUCTIONSOperating Manual VAS 5053 A01.3 08/04 All rights reserved.iiiA5E00310438VAS 5053VAS 5051BVAS 5051VAS 50527. Warning!Adequate ventilation should be provided when working on operating combustion engi-nes.8. Warning!Use only as described in this manual. Use only manufactures’s recommended attach-ments.9. Warning!When connected to electrical power supply, the devices correspond to protectionclass 1 and are fitted with a safety-tested power cable. They may only be connected to electrical networks with an earthed protective conductor (TN networks) or electrical out-lets with earthed protective conductors.10. Warning!All measurement probes shall be used within their specifications and as described within these instructions. All measurement clamps shall be used on appropriate insu-lated wiring. Do not conduct measurement, if the wiring is damaged.11. Warning!During test drives, secure the tester with a strap on the vehicle's back seatand connect it to the vehicle using the diagnostic cable. A second person must operate the tester from the back seat. Operation from the front seat is too dangerous, e.g. in the event of airbag activation.VAS 5051To supply the VAS 5051 with power from the vehicle battery, use only the 3 m diagnostic cable.
IMPORTANT SAFETY INSTRUCTIONSOperating Manual VAS 5053 A01.3 08/04 All rights reserved.ivA5E00310438VAS 5053VAS 5051BVAS 5051VAS 505212. Warning!Electrical ignition systems carry currents of up to approx. 30 kV. Observe general safety guidelines for workshops at all times.13. Warning!If you open the tester or its accessories without authorisation or carry out improper alte-rations to them, considerable risk to you and to the device may result.14. Caution!Fluctuations and deviations in the power supply beyond the permitted range of toler-ance can lead to malfunctions and damage.15. Caution!         VAS 5051 - changing fuseFor inline current measurement with the VAS 5051, only a replacement fuse of the same type and same amperage may be installed in order to avoid risks of fire and to protect the device. To order original parts, refer to the corresponding chapters of the Operating Manual.16. Caution!          when connecting other vehicle makesThe VAS 505x diagnostic devices were developed for vehicles from the Volkswagen group. If the tester is connected directly to vehicles from other manufacturers, damage to the vehicle could result.Therefore if vehicles of other makes are to be tested using the general OBD functions in the self-diagnosis application, the OBD adapter cable VAS 5052/16 needs to be con-nected between the diagnostic cable and the diagnostic connection on the vehicle (with fewer cable connections).17. Caution!•Battery change may only be performed by qualified personel.•Do not short out the battery.•Do not incinerate the battery.•Dispose/recycle the battery in accordance with local environmental regulations.
IMPORTANT SAFETY INSTRUCTIONSOperating Manual VAS 5053 A01.3 08/04 All rights reserved.vA5E00310438VAS 5053VAS 5051BVAS 5051VAS 5052Warnings because of built-in Bluetooth transceiver18. Warning!FCC 15.105: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa-tion. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•Reorient or relocate the receiving antenna.•Increase the separation between the equipment and receiver.•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•Consult the dealer or an experienced radio/TV technician for help.19. Warning!FCC 15.19: This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.Operation is subject to the following two conditions:1. this device my not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation.20. Warning!FCC 15.21: Changes or modifications made to this equipment not expressly approved by COMPANY may void the FCC authorization to operate this equipment.21. Warning! For body worn operation, this device has been tested and meets FCC RF exposure guidelines when used with a carry accessory that contains no metal. Use of other carryaccessories may not ensure compliance with FCC RF exposure guidelines.
IMPORTANT SAFETY INSTRUCTIONSOperating Manual VAS 5053 A01.3 08/04 All rights reserved.viA5E00310438VAS 5053VAS 5051BVAS 5051VAS 5052SAVE THESE INSTRUCTIONSNoteA Bluetooth interface application for communication with external devices, e. g. diag-nostic head VAS 5054 is projected.Trade Name:  Siemens AG Model No: VAS 5053FCC ID: LYHVAS5053IC: 267AA-VAS5053This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions. (1) this device my not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Technical DataOperating Manual VAS 5053 A01.3 08/04 All rights reserved.2-1A5E003104382 Technical Data2.1 Docking StationDimensions (W x H x D) 250 x 200 x 105 mmWeight 2 kgAmbient conditionsOperationTransportation and storageAmbient temperature  +5 to +40 °CRelative humidity  25 to 80 %, non-condensingAmbient temperature  -20 to +60 °CRelative humidity  25 to 80 %, non-condensingElectrical protection and safetySafety regulations- Workshop devices: UL 201- Devices for information processing:   DIN EN 60950 (VDE 0805), EN 60950, IEC 950,   UL 1950, CSA-C22.2 No. 950- Testing devices: DIN EN 61010-1 (VDE 0411 Part 1),   EN 61010-1, IEC 1010-1Protection class I (as per DIN EN 60950), for the external adapter unit onlyProtected from water and foreign objects as per DIN VDE 0470 Part 1 (EN 60529, IEC 529)- Tester: degree of protection for housing: IP 20For company-internal use onlyPollution Degree IIOvervoltage category IExternal interfacesDC inputUSB interfaceLANDocking interface2 USB 2.0 standard, type A1 USB standard, type BIEEE802.3 10BaseT//100BaseTX RJ45Total electricalconnected loadAccording to nameplate on underside of docking station and rear side of operating unit (underneath the strap):24 V / 2 A
Technical DataOperating Manual VAS 5053 A01.3 08/04 All rights reserved.2-2A5E003104382.2 VAS 5053 Operating Unit (Tester)2.2.1 Operating DataPower adapter The power adapter supplies the VAS 5053 from the 230 (110) Volt mains network. When the operating unit is placed on the docking station, the optional battery is recharged.Dimensions (W x H x D) Approx. 223 x 61 x 148 mmWeight 1.3 kg (without optional battery)Ambient conditionsOperation see section 2.1Electrical protection and safetysee section 2.1Power supply Power is supplied by one of the following, depending on the application:- The docking station- Battery (optional)- Vehicle electrical systemPower supplyfrom the docking stationsee section 2.1Power supplyfrom the optional batteryBattery typeWeightBuffer timeRecharge time(on mains)Battery buffer in the event of power outage (vehicle electrical system or mains)Li-ION, 14.8 V0.2 kgUsually 3 h (depending on operating mode, battery state and the external consumers)Approx. 2.5 h
Technical DataOperating Manual VAS 5053 A01.3 08/04 All rights reserved.2-3A5E003104382.3 Power AdapterPower supply from thevehicle electrical systemRated voltagesCurrent consumption in theload rangeProtectionThe tester can be powered from the vehicle electrical system.DC 12 V, DC 24 VApprox. 2.5 A with 12 V battery voltageThe input is protected against disturbance variables to DIN 40839 part 1, test pulses 1 to 4, test severity IV.The input is protected against polarity reversal.External interfacesCompact FlashPCMCIA slotDiagnostic interfaceDocking interfaceMultifunction interfaceBluetoothFor Flash cards 1 x type I/IIFor PCMCIA cards 1 x type III or 2 x type II18-pin mini SNAP socket, size 316-pin mini SNAP socket, size 2wirelessPower adapter The power adapter supplies the VAS 5053 from the 230 (110) Volt mains network.Rated voltage rangeRated frequenciesAC 100 to 240 V50 - 60 HzDC cable The DC cable (1.8 m), permanently attached to the power adapter, is connected to the DC input on the rear side of the docking station. The operating unit is supplied with power via the docking interface.Mains cable The mains cable (3 m) can be replaced with a mains cable of the type applicable in the country of use. The mains cable must comply with the standard for operating appliances on an earthed power supply network.(VDE 0805, EN 60950, IEC 950, UL 1950, CSA 22.2 No. 950)For operation in the USA and Canada, use a UL-approved or a CSA-approved mains power cable.
Technical DataOperating Manual VAS 5053 A01.3 08/04 All rights reserved.2-4A5E003104382.4 CablesDiagnostic cableUSB cabelUSB/LAN adapter cable, optional3 m, cable bend diameter 10 x cable diameter2 m0.3 mPlug cycles > 1.000

Navigation menu