Sierra Monitor Corporation Gas Sensor Modules 4101 Users Manual 4101XX DS
4101 to the manual 330b35ed-982f-467b-9438-2c7b4d152713
2015-02-02
: Sierra-Monitor-Corporation Sierra-Monitor-Corporation-Gas-Sensor-Modules-4101-Users-Manual-491374 sierra-monitor-corporation-gas-sensor-modules-4101-users-manual-491374 sierra-monitor-corporation pdf
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
Model 4101 Series Gas Sensor Modules The Model 4101 Series Gas Sensor Modules feature accurate detection of the specified gas with linear 4-20 mA output. The Sierra Monitor Model 4101 Series provides the user with the features needed in a stand-alone, fixed-point hazardous gas monitor system. Utilizing catalytic bead sensor for combustible gas and electrochemical sensor technology for the oxygen and toxic gas sensors, the Model 4101 provides accurate monitoring of hazardous gas conditions. Proven sensor design matched with reliable state-of-the-art electronics results in the ideal complete single channel package to protect your plant and personnel. Automatic Low Sensitivity Check Monitoring integrity is ensured with the automatic low sensitivity check. After calibration, a sensor sensivity check confirms that the sensor response to gas is sufficient to provide reliable operation without false indication. If the sensor has low sensitivity, an LED lights to indicate that sensor replacement is due. False Alarm Avoidance During Power-Up and Calibration, the transmitter output is locked at 4 mA (except Oxygen sensor modules). The output remains locked for five minutes directly after power is applied or after calibration gas is removed, allowing sufficient time to fully stabilize before coming on-line. This avoids erroneous readings during warm-up and prevents alarm caused by calibration gas. 4101-02 Convenient Diagnostic Measurements Critical measurements are made at convenient jacks for a Volt Ohm Meter. Each measurement location is clearly marked. All modules have a signal output adjustment. Simple Zero and Span Adjustments Easily accessible potentiometers enable calibration adjustments to be made in minutes by non-technical personnel for reduced maintenance cost. Flexible Alarm and Logging Options The analog gas sensor modules can be used as part of a facility gas risk management plan. The 4-20 mA output signal is ideally suited to interface with a wide range of instrumentation for alarm annunciation and recording. The sensor module is housed in a NEMA-7 enclosure rated for Class 1, Division 1, Groups C, D environments. An optional NEMA 4 Group B enclosure is available. 4101-04 - 22/27 Sierra Monitor Corp. 1991 Tarob Ct., Milpitas, CA 95035, USA, 408-262-6611, 800-727-4377, FAX: 408-262-9042 Web Site: http://www.sierramonitor.com E-Mail: sierra@sierramonitor.com 0504 Gas Sensor Modules Specifications Gas Type Model Combustibles Oxygen Carbon Monoxide Hydrogen Sulfide Chlorine Sulfur Dioxide Nitrogen Dioxide Carbon Monoxide 4 Carbon Monoxide Nitric Oxide Hydrogen Chloride Hydrogen Cyanide Ammonia Hydrogen Fluoride Ethylene Oxide Notes: (1) (2) (3) (4) (5) Sensor 4101-02 Catalytic 4101-03EL EC 4101-04 EC 4101-05 EC 4101-06 EC 4101-10 EC 4101-12 EC 4101-13 EC 4101-16 EC 4101-19 EC 4101-21 EC 4101-22 EC 4101-25 EC 4101-26 EC 4101-27 EC Range Units Resolution Response Sensor Time (1) Life (2) 0-100 %LEL +/-3% F.S. (3) 3 Yrs 0-25 % Vol +/-0.1% <10 sec. 2 Yr 0-500 PPM 1.0 PPM <25 sec 2 Yrs 0-100 PPM 0.1 PPM <30 sec 2 Yrs 0-10 PPM 0.1 PPM <60 sec 2 Yrs 0-100 PPM 0.5 PPM <20 sec 2 Yrs 0-20 PPM 0.2 PPM <35 sec 2 Yrs 0-1000 PPM 0.5 PPM <35 sec 2 Yrs 0-2000 PPM 0.1 PPM <35 sec 2 Yrs 0-20 PPM 0.5 PPM <15 sec 3 Yrs 0-20 PPM 0.1 PPM <100 sec 2 Yrs 0-20 PPM 0.1 PPM <70 sec 2 Yrs 0-50 PPM 1.0 PPM <30 sec (5) 0-10 PPM 1.0 PPM <30 sec (5) 0-20 PPM 0.1 PPM <90 sec 2 Yrs Operating Range o F C RH -40 to 167 -40 to 75 10 - 95% 5 to 122 -15 to 50 5 - 99% -4 to 122 -20 to 50 15 – 90% -40 to 122 -40 to 50 15 – 90% -4 to 122 -20 to 50 15 – 90% -4 to 122 -20 to 50 15 – 90% -4 to 122 -20 to 50 15 – 90% -4 to 122 -20 to 50 15 – 90% -4 to 122 -20 to 50 15 – 90% -4 to 122 -20 to 50 15 – 90% -4 to 122 -20 to 50 15 – 90% -4 to 122 -20 to 50 15 – 90% 14 to 113 -10 to 45 20 – 95% 14 to 113 -10 to 45 20 – 95% -4 to 122 -20 to 50 15 – 90% o Response time to 90% full signal value for applied concentration Sensor life typical for use at standard temperature and pressure with occasional exposure to gas of interest Step to 50% LEL within 10 seconds. Recovery to 10% LEL within 30 seconds Hydrogen tolerent Diffusion via membrane. Requires electrolyte and membrane replacement every 6 months. Construction Electrical Data Loop Type 3 wire Modules Loop Resistance 800 Ohm with 28VDC 4101-02 400 Ohms at 21 VDC (4101-02) Input Voltage DC 14-30 VDC (20-30VDC 4101-02) Input Current 40 mA (80 mA 4101-02) Input Power Max 1.4W (2.3W 4101-02) Signal Output 4-20 mA DC linear (trouble 0 mA) Operating Pressure 4101-03EL Dimensions Weight H: 7.5", D: 4.0", W: 4.0" 2.0 lb (21.6 x 10.2 x 10.2 cm) (0.9 Kg) H: 8.5", D: 4.0", W: 4.0" 2.1 lb (21.6 x 10.2 x 10.2 cm) (1.0 Kg) 4101-04-27 H: 8.0", D: 4.5", W: 4.0" 2.7 lb (20.3 x 15.2 x 15.2 cm) (1.3 Kg) 4101-25/26 H: 10.2", D: 6.0", W: 6.0" +10% (variation from ambient) 2.7 lb (25.9 x 15.2 x 15.2 cm) (1.3 Kg) Cross Sensitivity Data Model Number 4101-04 4101-05 Gas type CO H2S 4101-06 4101-10 4101-12 4101-13 4101-16 4101-19 4101-21 4101-22 4101-27 Cl2 SO2 NO2 CO CO NO HCl HCN C2H4O (ETO) CO 100 H2S 5 <2 100 0 <-10 <1 0 0 -20 100 350 100 0 0 35 0 75 <0.5 Ethanol Toluene Methyl-ethyl-ketone Carbon Monoxide Reading from 100 PPM of interfering gas Cl2 H2 SO2 NO2 NO 0 <20 0 0 6 -20 100 -40 90 0 0 0 -10 -50 55 20 10 40 <0.1 0 0 0 <60 0 0 0 0 <15 0 100 0 60 0 5 35 160 -15 105 -100 100 -60 0 25 -2 -190 0 0 0 0 25 0 100 0 -5 HCl 0 HCN 0 C2H4 <50 0 0 0 0 0 0 15 100 0 0 15 -3 0 0 0 -8 100 0 0 0 0 <75 35 0 0 <1 4101-02 Combustible Gas Sensor is FM Approved 05/04 Sierra Monitor Corp. 1991 Tarob Ct., Milpitas, CA 95035, USA, 408-262-6611, 800-727-4377, FAX: 408-262-9042 Web Site: http://www.sierramonitor.com E-Mail: sierra@sierramonitor.com © 2004 by Sierra Monitor Corporation
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Modify, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Modify Date : 2004:10:15 08:58:23-06:00 Create Date : 2004:10:15 08:58:20-07:00 Author : judith Subject : 4101XX-DS Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:11b7b48e-93c1-44b3-9e2e-76779619d95e Producer : Acrobat Distiller 6.0.1 (Windows) Keywords : Creator Tool : Adobe PageMaker 7.0 Document ID : uuid:0b553776-8555-4bcf-bd4e-61aa5ea9dd5e Format : application/pdf Description : 4101XX-DS Title : 4101XX-DS Creator : judithEXIF Metadata provided by EXIF.tools