Signal Communications SCVT-000126 TeleEye Pro User Manual
Signal Communications Limited TeleEye Pro
User Manual
Te/eEye 73m Transmission Unit PTA1 6-31 I PTA1 6-C1l User Guide s.:: Notice: Signal Communications Limited reserves the right to make improvements to the product described in this manual at any time and without notice. This manual is copyrighted. All rights are reserved. This manual may not be copied, reproduced or translated in whole or part without prior consent fiom Signal Communications Limited- Third party trademarks are the property of their respective holders. Copyfight (0) 199598 Signal Communications Limited- All rights reserved. Version 2.6 Limits of Liability and Disclaimer of Warranty Signal Communications Limited have taken care in preparation ofthis manual, but makes no expressed or implied warranty of any kind and assume no responsibility for errors or omissions. No liability is assumed for incidental or consequential damages in connection with or arising out of the use of the information or accessories contained herein. FCC Statement on Class B WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determine by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 0 Reorient or relocate the receiving antenna. 0 Increase the separation between the equipment and receiver. 0 Connect the equipment into an outlet on a circuit different from that to which the receiver is needed. - Consult the dealer or an experienced radio/TV technician for help. Shielded cables must be used with this unit to ensure compliance with the Class B FCC limits. Table of Contents SECTION 1 INTRODUCTION SECTION 2 INSTALLING TeleEye fig What You Need System Connections Software Installation Registering the Transmission Unit Connecting re/eWin to TeIeEye f?” Alarm Port Definition Pin Definitions for Null Modem Cable Transmitter Unit SECTION 3 SPECIFICATIONS . Model: PTA16-B1 and PTAl6-Cl we» .—-O\D\Dmm 11 SECTION 1 INTRODUCTION Te/eEye 77m is an advanced Video Monitoring System. The transmission unit is especially designed for monitoring medium sized firm, factory and warehouse. Two models are available to suit for different applications. PTA16- B1 is a monitoring system transmitting B/W video frames PTA16-C1 functions as standard model for the transmission of color video. Features Transmits high quality videos of multiple CCTV cameras Achieves fast video update by using an interframe image compression Password protection on connections and settings Built—in real time clock Multiple alarm inputs with independent NC / NO trigger contacts Remote control through 2 relay switches About the Reception Software The TeIeWin Reception Software is a Win95 application program (IBM or compatible PC)‘ It implements the system controls as well as image decoding of the Ts/sEye 7)” systems. The compressed data are decoded and displayed through the PC monitor PageS What You Need THO—Fl INSTALLING TeIeEye "Pro To install and operate the Te/eEye 7)” transmission unit, the following items are required: - Te/eEye he Transmission Unit The image transmitter supports up to 16 video sources in all PAL or NTSC format. a CCD Camera Color / monochrome, PAL or NTSC. - Coaxial Cable (RG-59 recommended) It is used to connect the video output of the CCD camera to the video input of TeIeEye an transmission uniti ~4Mm It is a shielded 37 ways cable. . MM It is used to connect the TeleEye 'Pn transmission unit to one of the COM port of the PC. PageG System Connections Up to 1621313115 Up to 16 Cameras ._.5 IBM Compatlhle Recommended Setup Procedures: Step 1: Plug one end at the Null Modem cable into the socket marked MODEM on the TeIeEye 'Pu transmitter, then plug the other end to the COM port of the computer. Step 2: Plug one end of the BNC cable into the VIDEO OUTPUT of the CCD camera, then plug the other end to the TeIeEye 7» 's VIDEO INPUT connector (CH1 preferred) It more than one camera, plug the BNC cable to the Te/eEye 7)» CH: to CH16 sequentially. Step 3: Plug one end of the alarm cable into the connector of the elan'n sensor and plug the other end of the cable to the appropriate pins of the ALARM CONNECTOR of the TeIeEye $14 ‘ step 4: Plug the round and of the ac, adaptor Into the socket marked POWER on the re/eEye 'Pn transmitter. (Note: transmitter can support 9V dc. to 12V do. supply voltage) Step 5: Plug the ac. adapter to ac, power source and switch on the TeIeEye 7:4. The TeIeEye 7M: ‘s LED should light up, Page7 Software Installation Before setting up TeIeWin, please change the video setting to 800 x 600 true colour or 16—bit high colour in Win95’s Display Properties. Te/eWin software contains an installation program, SETUP.EXE. Please use this program to setup the necessary files into the hard disk of the reception unit. Once you have completed the following installation procedure, you can run Te/eWin directly from your hard disk Registering the Transmission Unit Before connecting to the transmission unit, you have to perform transmission unit registration. This can be done under the Transmitter menu. Transmission unit registration is required only once; all the information will be recorded in the hard disk. In the package, you are provided with a Registration Code and a Serial Number of the transmission unit. You need to fill them in the Registration Message Box as shown below. Besides, please keep them in a safe place for future reference negmmnmn mm a Page8 Connecting Te/eWin to TeIeEye $0.3 Step]: Make sure you video setting of Win95 environment is 800 x 600 true colour or 800 x 600 16-bit High Colour. To sum Te/eWin Reception Software, click on the Start button on the taskbar, then choose Programs —> Te/eEye ”Pm _> TeleEye ‘Pn WRS-AD-l. StepZ: To connect to the TeIeEye ?" , click Connect under the Connection menu or the Connect icon. Step3: In the Connect Using box, select Direct to COM] or Direct to COM2. That is the COM port that the null modem cable is physically connecting to. Step4: Fill in the password in order to connect. The default password is 000000. StepS: You may now click the connect button to make connection. You may disconnect the connection by selecting Disconnect on the Connections menu or clicking the Disconnect button. You may reset the alarms by clicking Reset Alarm under the Alarm menu and fill in the password. The default password is 000000 Alarm Port Definition Pin1 - ALARM IN 1 Pin 19 - GND Pin 9 - ALARM IN 9 Pin 27 - GND Pin 2 - ALARM IN 2 Pin 20 - GND Pin 10 - ALARM IN 10 Pin 28 - GND Pin 3 ~ ALARM IN 3 Pin 21 - GND Pin 11 -AMRM IN 11 Pln 29 - GND Pin 4 - ALARM IN 4 Pln 22 - GND Pin 12 -AI.ARM IN 12 Pin 30 - GND Pin 5 - ALARM IN 5 Pin 23 - GND Pin 13 - ALARM IN 13 Pln 31 - GND Pin 6 - ALARM [N 6 Pin 24 - GND Pln14 - ALARM IN 14 Pin 32 - GND Pin 7 ~ ALARM IN 7 Pin 25 - GND Pin 15 - ALARM IN 15 Pin 33 ~ GND Pin 8 - ALARM IN 8 Pin 26 - GND Pin 16 - ALARM IN 16 Pin 34 - GND Pin 35 ~ GND Pin 17 - OUTPUT SWITCH 1 A Pin 36 -0UTPUT SWITCH 1 B Pin 18 - OUTPUT SWITCH 2 A Pin 37 - OUTPUT SWITCH 2 B Pin Definitions of NULL MODEM CABLE TeIeEye 7” PC PC Pin definitions of a Transmission Unit DBZS DB9 DB-9 (female) to 2 RXD <——-————> m 2 3 DB-25 (female) or 3 TXD % RXD 3 2 DB-9 (female) to 1 CD % DTR 20 4 DB-9 (female) null 4 DTR M CD g g 5 GND % GND modem cable 7 RTS CTS 5 8 s CTS % RTS 4 7 Page9 Transmission Unit The panels of the Te/eEye 7” transmission unit are shown below : PT A] 6-B1/PT AI 6-CI Front Panel Tale-Eye P” 76 Functional Description VIDEO IN Connectors (CHI - CHSI - Standard BNC connectors for the video sources - A composite video signal should be supplied to these connectors ALARM IN Connector - This connector is used for connecting 2 remote control switches and 8 alarm inputs - All alarm channels have the same priority Communication Port A DB—9 male connector for connecting to COM port of PC Power Connector A 2.1mm DC powerjack for the connection to the power supply (9V-12V DC) Power Switch A onloff switch of power. Page 1 0 SECTION3 SPECIFICATIONS MODEL PTA 1 6-B1 / PTAIG-CI STANDARD (P): PAUCCIR, 625 LINES, 50 FIELDS PER SECOND (N): NTSC/EIA, 525 LINES, 60 FIELDS PER SECOND INTERFACE I6 CHANNELS, 1.0Vpp COMPOSITE, BNC WITH 750 TERMINATION INPUT SWITCH RESOLUTION (H x V) 256 x 192 PIXELS GRAY LEVELS 256 COLORS 16 MllLION COIVH’RESSION SCALEABLE ADAPTIVE IMAGE COMPRESSION 16 INDEPENDENT CHANNELS, NC / N0 2 CHANNEL, DRY CONTACT CONTACT RATING : 2A, 120V AC, RESISTIVE LOAD : 2A, 28V DC. TYPE RS-232C, DB-9 MALE CONNECTOR RATE 38,400 BITS PER SECOND FORMAT ASYNCH'RONOUS‘ 8 DATA BITS, NO PARITY, 1 STOP BIT ,8,] FLOW CONTROL HARDWARE RTS, CTS! DIMENSION (yv x D x H) PROTOCOL EFFICIENT ERROR CONTROL PROTOCOL INPUT VOLTAGE 9 - 12V DC POWER CONSUMPTION 12W (MAX) AMBIENT +5°c TO +40°C TEMPERATURE (40°C TO 104°F) RELATIVE HUMIDITY 20% TO 85%, NO CONDENSATION 330mm x 280mm x 65mm COLOR BLACK WEIGHT 27 kg Page] I
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Modify Date : 2000:03:20 17:07:34+08:00 Create Date : 2000:03:20 17:07:16+08:00 Creator : Acrobat 4.0 Scan Plug-in for Windows Producer : Acrobat 4.0 Scan Plug-in for Windows Page Count : 11EXIF Metadata provided by EXIF.tools