Signify LCN7700 Segment Control Unit User Manual LCN7700 UG20161207

Philips Lighting(China) Investment Co.,Ltd. Segment Control Unit LCN7700 UG20161207

LCN7700_UG20161207

Download: Signify LCN7700 Segment Control Unit User Manual LCN7700 UG20161207
Mirror Download [FCC.gov]Signify LCN7700 Segment Control Unit User Manual LCN7700 UG20161207
Document ID3220355
Application IDfhkRE/A8ksr1fYJVWe0pnA==
Document DescriptionLCN7700_UG20161207
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize37.08kB (463505 bits)
Date Submitted2016-12-07 00:00:00
Date Available2016-12-07 00:00:00
Creation Date2016-12-02 13:39:09
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2016-12-02 13:41:34
Document TitleLCN7700_UG20161207
Document CreatorAdobe InDesign CC 2017 (Macintosh)

Segment Control
Unit
Product guide
LCN7700
The Segment Control Unit is central processing unit (CPU)
in the cabinet system. Equipped with a powerful ARM
Cortex A5 (550MHz) processor and a Linux kernel.
Commonly used interfaces for Energymeter, load current
and leakage measurement, relays for contactor mains
switching are integrated into the Segment Control Unit for
ease of wiring and compactness.
Direct communication between the optional modules
takes place by means of an A-Bus interface, which is
based on the industrially proven RS485 technology.
LCN7700
Data are either delivered to the server immediately or
stored locally in the built-in flash or external SD card
memory of the Segment Control Unit until scheduled
delivery. Software and configurations are updated
remotely from the server and stored on the Segment
Control Unit enabling it to autonomously execute
tasks, e.g. turn the streetlight on/off or collect meter
readings based on the configurations set up by the
user.
Voltage values on all three phases of the main supply
are monitored by the Segment Control Unit. If the
module is installed together with a Battery module,
the Segment Control Unit will be supplied with backup
power via the A-Bus in the event of power failure. This
enables the Segment Control Unit to store data and
send a main power failure alarm to the central server
before it shuts down safely.
In general, the Philips Segment Control Unit can be
used for remote light management in diverse outdoor
Lighting applications.
Dimensional drawing
86 mm (3.3 in)
The Segment Control Unit serves as a WAN
communications and data concentrator module.
Two-way communication with the central server takes
place via Ethernet, GPRS (3G/2G) or SMS. The module
has the ability to automatically switch between
different available communications carriers in order
to provide stable and reliable communication.
58 mm
(2.2 in)
192 mm (7.5 in)
Philips quality
Lifetime: 70000 Hrs @ 10% failure rate.
For more detailed information see the specific
module manuals & guides.
Applications
The Segment Control Unit is a power grid monitoring
and group lighting control device.
It is designed to be installed inside an IP65 rating
outdoor street cabinet. This control unit is designed
as a local controller for group light controls as in
road and street, expressway, premises/campus area
lighting, public parks or in tunnel lighting applications.
For remote connectivity, 2G/3G network can be used
or Ethernet connectivity in case the cabinet is located
indoors.
The accurate current measurement can help to detect
power thefts when the current value goes beyond
a threshold limit defined. The inbuilt GPS locater
helps to detect the location of the installed controller
remotely to enable ease of commissioning. The DALI
interface gives opportunity to control other DALI
enabled devices like a group of luminaires in a high
mast pole in airport or port applications with dimming
capability. The wide input power supply voltage range
from 120-277V makes the controller to be used in wide
geographical locations. The use of an external surge
protection module is highly recommended to protect
the Segment Control Unit from surges.
Product Guide - LCN7700
Functional specifications
The Ethernet connection is, in addition to this,
functionally insulated with respect to the secondary
connections. See for detailed information the
technical specification section.
GSM/GPRS
SMA connector for external
GSM antenna. GSM850,
E-GSM900, GSM1800
(DCS1800), GSM1900
(PCS1900).
SIM Card
Micro SIM card is inserted
on top part of the Segment
Control Unit.
Micro SD card
Micro SD card is inserted
on top part of the Segment
Control Unit.
A-Bus
1x5 internally connected
signals that are used for
the A-Bus. The internal
connection makes it easier
to daisy-chain to other
controller modules.
RS485
Supports multiple baud
rates. Default value is 9600
bps.
DALI
DALI master without DALI
Power Supply.
Current Sensing
Phase current sensing and
leakage current sensing.
RS232 interface
For use with RS232 power
meters, maximum data
transfer rate 115.2 Kbps.
GPS Antenna
Insert the antenna in the
antenna socket of the
Segment Control Unit and
tighten it gently with your
fingers. Do not use tools.
GPRS Antenna
Insert the antenna in the
antenna socket of the
Segment Control Unit and
tighten it gently with your
fingers. Do not use tools.
Primary
Power (L1, L2, L3,
, N)
Three mains rated phase (line) inputs: L1, L2 and L3
One mains rated alarm monitor input:
One mains neutral input: N
The Segment Control Unit can be mains powered by
one, two, or three phases plus neutral. When powered
by multiple phases, the Segment Control Unit is able
to detect phase faults on the mains power supply.
If a fault occurs on one or two phases, the Segment
Control Unit will still be powered by the remaining
phase(s). In this case, the Segment Control Unit will
send an alarm to the central server. The alarm monitor
( ) is a mains rated input (related to mains Neutral
(N)) for cabinet door monitoring.
Secondary
USB
2x USB 2.0 host port for
additional devices
Inputs
2x Analog
1x Digital
Ethernet
Product Guide - LCN7700
Low voltage measurement
inputs analog input 1 and
analog input 2 (positive
voltage w.r.t. GND).
Low voltage input digital
input (positive voltage w.r.t.
GND).
RJ-45 connector, 100/10
Mbps, half & full duplex,
functional insulated from
the secondary connections.
Reliability & Maintainability
Software upgrade/
installation
Multi-layer system
The software on the
Segment Control Unit can
be updated remotely from
the central server. New
software is transferred
without interrupting the
normal functionality of the
Segment Control Unit.
When the software has
been transferred, the
integrity of the software is
checked and the software is
installed.
Connections on the secondary side
All cables on secondary side should preferably be
shielded, with the shield connected to GND (pin5 for
the A-Bus).
EU directives
Use shielded twisted pair
(2x2) cable. The Segment
Control Unit can be
connected to any client
module e.g. AmpLight
RS485, AmpLight Switch.
Double connections on
the A-Bus makes daisychaining of the signals easy.
For detailed information,
see wiring diagrams.
Various internal processes
ensure that the system is up
and running at all times.
A-Bus cable
cable length < 3 m
In case a process has failed,
it is restarted without
disturbing other processes.
RS485
cable length < 3 m
Analog/Digital Input
cable length < 3 m
Current Sensing Input
cable length < 3 m
Keep wiring short from the mains circuit breaker
towards the mains power input.
When using a surge protection module, the wires
between the surge protection module and the
Segment Control Unit may not exceed 0.15 m.
Philips recommends for outdoor applications to use a
surge protection module.
DALI
cable length < 10 m
USB
cable length < 3 m
At least one GROUND connection needs to be
connected to Earth or screwed GPS or 2G/3G antenna
is connected and installed on cabinet.
RS232
cable length < 3 m
Ethernet
cable length < 3 m
Mains Input
cable length < 1.5 m
System health
Self-test
A built-in self-test is
performed after power-up.
Installation
The Segment Control Unit should be protected from
dust and water, preferably by enclosing the system in
a metal IP class 65 (NEMA type 4) outdoor cabinet.
Connections on the primary side
Product Guide - LCN7700
Technical data
Environmental
Storage temperature
-40° C – +85° C
Operating temperature
-20° C – +60° C
Max humidity
90% (non-condensing)
Analog inputs
Input range 0-10 V, 4-20
mA (0-20 mA):
Impedance = 510 ohm (DC)
Accuracy = ± 2% FSD at 25° C
When used as digital input:
Threshold of approximately
1V
Absolute maximum input
voltage = 12 V (A-Bus
voltage can be used.).
Digital input
Internal 100 Kohm resistor
- 1 Mohm pull-up resistor.
Connect terminal to GND
for a digital low. Make
sure that the terminal to
GND resistance is below
1 Kohm (current internally
limited to 3 uA). Keep wires
connected to this high
impedance input away from
disturbing networks.
Current Sense
Sensor input detection
range: 170 – 1000 mA.
Use with LCU7591 AmpLight
Leak Coil only.
Input range: 5 – 15 mA
(including = 5 mA), abs.
accuracy ± 5% FSD; 1-5 mA,
abs. accuracy ± 10% FSD
Current sensor input(s)
Detection range: 5 – 65 A.
Use with LCU7590 AmpLight
3-Phase Coil only.
Input range: 5 – 100 mA
(including = 5 mA), abs.
accuracy ± 5% FSD; 1-5 mA,
abs. accuracy ± 10% FSD
Supply characteristics
Input voltage
UL: 120 – 277 VAC (3P + N)
CE: 220 – 240 VAC (3P + N)
Nominal voltage: 230 VAC,
Nominal frequency: 50/60
Hz (± 5 Hz).
Relay
Endurance on given maxima
100.000 operations
Max switching voltage:
for CE: Max 250V;
for UL: 120 – 277V.
COM1, NO 1 750 VA
COM1, NC 1 750 VA
COM2, NO 2 750 VA
Max switching current:
3 A (resistive).
Power consumption
<3 W, Segment Control Unit
only, no load on A-Bus and
USB.
Nominal system
power consumption
< 5.5 W, Segment Control
Unit with one AmpLight
Switch, one AmpLight
Current and one AmpLight
Battery.
Maximum system
power consumption
< 18 W, Segment Control
Unit and 460 mA on A-Bus
and each 250 mA on 2x
USB .
Current consumption
(powered via A-Bus)
Typical 100 mA, Max 300
mA at 12 V.
USB Maximum
250 mA, 5 V.
GSM/GPRS/EDGE
Bands
Supports GSM 850, E-GSM
900, DCS 1800, PCS 1900
Transmit power
GSM 850/ E-GSM 900:
max. 33 ± 2 dBm
DCS 1800/PCS 1900: max.
30 ± 2 dBm
Measurement characteristics
Input mains
Product Guide - LCN7700
Accuracy within 120 - 277
VAC range: ± 5% FSD (Full
Scale Deflection)
GPRS
DTM (simple class A)
operation.
GPRS Multislot class 10 (no
backoff) – Four Rx slots
(maximum), two Tx slots
(maximum), five active slots
total.
Coding schemes CS1, CS2,
CS3 and CS4.
GEA1, GEA2 and GEA3
ciphering.
WCDMA/GERAN system
selection.
EDGE
E2 power class for 8 PSK.
DTM (simple Class A),
Multislot class 12.
EGPRS – Multislot class 12
(with backoff).
BEP reporting.
SRB loopback and test
modes A and B.
8-bit and 11-bit RACH.
Support PBCCH.
One-phase /two-phase
access procedures.
Link adaptation and IR.
NACC, extended UL TBF.
Support PFC/PFI (Packet
Flow context/Packet Flow
identifier).
GPRS/EDGE MSC 12-EDA –
permits allocation of more
than two uplink timeslots
for GPRS/EDGE.
Enh DL RLC/MAC
Segmentation – permits
reception of MAC control
messages that exceed one
radio block capacity in
length.
Enhanced Ext UL TBF –
dummy block transmission
is punctured for current
saving purposes.
2G PS handover – packetswitched equivalent of CS
handover to ensure faster
cell change and improved
throughput.
SMS
SMS MO and MT. CS and PS
support.
SMS saving and reading
from UIM card or ME
storage.
SIM card
Support Micro SIM card.
Micro SIM card is inserted
on top part of the Segment
Control Unit.
SD card
Micro SD card is inserted
on top part of the Segment
Control Unit.
GNSS
RPSMA connector for
external GNSS antenna.
GPS (1575.42 ± 1.023 MHz)
and GLONASS (1597.5 –
1605.9 MHz).
WCDMA
Bands
Support B1, B2, B5, B8
Transmit power
Class 3bis (21 ± 2 dBm) at all
bands.
WCDMA R99
All modes and data rates for
WCDMA FDD. PS data rates
of 384 kbps DL and 384
kbps UL.
Product Guide - LCN7700
WCDMA R5 HSDPA
WCDMA R6 HSUPA
PS data speeds up to 42
Mbps (UE category 24) on
Mechanical
the downlink.
HS-DSCH (HS-SCCH, HSPDSCH and HS-DPCCH).
Maximum of 15 HS-PDSCH
channels, both QPSK and 16
QAM modulation.
Support for 3GPP-defined
features.
Switching between HSPDSCH and DPCH channel
resources, as directed by
the network.
STTD on both associated
DPCH and HS-DSCH
simultaneously.
CLTD mode 1 on the DPCH
when the HS-PDSCH is
active.
STTD on HS-SCCH when
STTD or CLTD mode 1
are configured on the
associated DPCH.
Support SCH-IC.
Support HS-DSCH DRX.
Housing
E-DCH data rates of up to
5.76 MB/s for 2 ms TTI (UE
category 6) uplink.
Support for 3GPP-defined
features.
STTD on all HSUPA
downlink channels.
CLTD mode 1 on HS-PDSCH
and DPCH along with
HSUPA channels.
Switch between HSUPA
channels and DPCH
channel resources, as
directed by network.
Handover using
compressed mode with
simultaneous EDCH and HS-DSCH
interactive, background,
and streaming.
QoS classes.
Support DPCCH DTX.
Top part
Polycarbonate Light Gray
(RAL 7035)
Base part
Polycarbonate Light Gray
(RAL 7035)
Coating
PCBA conformal coated
Mounting
DIN-rail (EN50022)
Weight
385 gr
Connections
Mains power connector
0.82 - 1.5 mm2 (18 - 14 AWG)
solid/stranded; copper
conductors only, wire rating
65° C min.; wire strip length:
8~9 mm; tightening torque:
0.40 - 0.50 Nm.
Analog/Digital inputs, A-Bus, 0.14 - 0.5 mm2 (26 - 20 AWG)
RS485, RS232, Current
solid/stranded; wire strip
sensing connectors
length: 5 mm; tightening
torque: 0.20 - 0.24 Nm.
DALI connectors
0.14 - 0.5 mm2 (26 - 20 AWG)
solid/stranded; wire strip
length: 5 mm; tightening
torque: 0.15- 0.20 Nm.
Relay connector
0.82 - 1.5 mm2 (18 - 14 AWG)
solid/stranded; wire strip
length: 6 mm; tightening
torque: 0.40 - 0.44 Nm.
Ethernet
Tab-Down RJ-45 meets
IEEE 802.3 Standard with
minimum of 1500 Vrms
isolation.
USB
USB2.0, Type-A Receptacle.
2G/3G Antenna
SMA female; Impedance
50 ohm, Tightening torque:
max 0.5 Nm.
GPS Antenna
RPSMA female; Impedance
50 ohm, Tightening torque:
max 0.5 Nm.
Product Guide - LCN7700
FCC Statement
This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired
operation.
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications.
Notice:
(1)	Changes or modifications not expressly approved
by the party responsible for compliance could void
the user’s authority to operate the equipment
(2)	The manufacturer is not responsible for any
radio or TV interference caused by unauthorized
modification to this equipment. Such modifications
could void the user’s authority to operate the
equipment.
(3)	This equipment complies with FCC RF radiation
exposure limits set forth for an uncontrolled
environment. This equipment must not be colocated or operating in conjunction with any other
antenna or transmitter. The equipment must be
installed to provide a separation distance of at
least 30 cm.
Standards and approvals
CE/CB
EN60950 for LVD
R&TTE with CISPR22 for RF certification and EMC
RoHS with EU directive 2011/65/EC (Philips RSL latest
update)
REACH with EU directive 2006/1907/EC (Philips RSL latest
update)
UL listed
UL 916 for safety
FCC Part 15 Subpart B, FCC PART 22/24 & MPE OET65
Packing data
Type
LCN7700 Segment Control Unit
Box dimensions
(mm)
711 x 581 x 159
Qty/Box Material
20
Cardboard
Box Weight (kg)
net
gross
7.7
10.7
Ordering Data
Type
LCN7700 Segment Control Unit
MOQ
Ordering
number
9137 003 89703
EAN code
level 1
8727900 947489
EAN code
level 3
8727900 947496
© 2016 Philips Lighting Holding B.V., all rights
reserved. Specifications are subject to change without
notice. Trademarks are the property of Philips Lighting
Holding B.V. or their respective owners.
Version 2, 2 December 2016
www.philips.com
EOC
947489 00

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2016:12:02 13:39:09+01:00
Creator                         : Adobe InDesign CC 2017 (Macintosh)
Modify Date                     : 2016:12:02 13:41:34+01:00
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.158975, 2016/02/13-02:40:29
Metadata Date                   : 2016:12:02 13:41:34+01:00
Creator Tool                    : Adobe InDesign CC 2017 (Macintosh)
Instance ID                     : uuid:989aea15-d7ff-a44f-bda3-73a40dcc496b
Original Document ID            : adobe:docid:indd:b1ddd603-51ee-11db-b025-8168767f4149
Document ID                     : xmp.id:6a205fb0-909c-40ca-b2bd-ceae0be17523
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:ade0c9e1-ed44-4b8f-9c19-8b6dc35158f1
Derived From Document ID        : xmp.did:ade0c9e1-ed44-4b8f-9c19-8b6dc35158f1
Derived From Original Document ID: adobe:docid:indd:b1ddd603-51ee-11db-b025-8168767f4149
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Macintosh)
History Changed                 : /
History When                    : 2016:12:02 13:39:09+01:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Layout                     : TwoPageRight
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AGBW-LCN7700

Navigation menu