Silent Call Communications SCXMIT10 418 MHz Periodic Transmitter for use in Hearing Impaired Applications User Manual O M Manual

Silent Call Communications 418 MHz Periodic Transmitter for use in Hearing Impaired Applications O M Manual

Manual

Download: Silent Call Communications SCXMIT10 418 MHz Periodic Transmitter for use in Hearing Impaired Applications User Manual O M Manual
Mirror Download [FCC.gov]Silent Call Communications SCXMIT10 418 MHz Periodic Transmitter for use in Hearing Impaired Applications User Manual O M Manual
Document ID2907973
Application IDwiw3TZ+r3GLlVxSKIrqcEQ==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize76.29kB (953595 bits)
Date Submitted2016-02-22 00:00:00
Date Available2016-02-22 00:00:00
Creation Date2016-02-08 14:14:09
Document Lastmod2016-02-08 14:14:09
Document TitleO&M Manual Template
Document Author: HHS EPLC Team

SCXMIT10 418Mhz Consolidated Transmitter Series
Installation Instructions
Revision IR
Date 01/12/2016
www.silentcall.com
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
REVISION HISTORY
Revision #
Initiated
By
Revision
Date
Approved by
Approval
date.
Reason
Retain this record in front of this manual. Upon receipt of this revision, insert and remove pages
accordingly. Then enter on this page, the revision number, issue date, insertion date, and your initials.
Document # 20-325-018-01 Rev IR
Page 2 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
TABLE OF CONTENTS
SECTION 1:
INTRODUCTION.................................................................................................................................... 5
1.1 PURPOSE: ...................................................................................................................................................................................5
SECTION 2:
SYSTEM DESCRIPTION ....................................................................................................................... 5
2.1 KEY FEATURES: ...........................................................................................................................................................................5
2.2 CONSOLIDATED TRANSMITTER (FA3-MC) SPECIFICATIONS: ........................................................................................................5
2.3 REGLATORY INFORMATION NOTICE: ..........................................................................................................................................6
2.4 TRANSMITTER FEATURES: ...........................................................................................................................................................6
2.5 TRANSMITTER SETTINGS: ............................................................................................................................................................6
2.6 REPLACEMENT BATTERIES: .........................................................................................................................................................6
2.7 TRANSMITTER MOUNTING AND LOCATION: ................................................................................................................................6
SECTION 3: CONFIGURED TRANSMITTER INSTRUCTIONS ............................................................................... 7
3.1 BM418-MC Installation: ..............................................................................................................................................................7
3.2 BM418-MC Operation: ................................................................................................................................................................7
3.3 DB2-MC Installation: ...................................................................................................................................................................7
3.4 DB2-MC Operation: ....................................................................................................................................................................7
3.5 DB41-MC Installation: .................................................................................................................................................................8
3.6 DB41-MC Operation:...................................................................................................................................................................8
3.7 DW3-MC Installation: .................................................................................................................................................................8
3.8 DW3-MC Operation: ...................................................................................................................................................................8
3.9 FA3-MC Installation: ...................................................................................................................................................................9
3.10 FA3-MC Operation: ...................................................................................................................................................................9
3.11 FA41-MC INSTALLATION: ..........................................................................................................................................................9
3.12 FA41-MC OPERATION: ..............................................................................................................................................................9
3.13 MAT4-MC Installation ............................................................................................................................................................. 10
3.14 MAT4-MC Operation: .............................................................................................................................................................. 10
3.15 SM5-MC Installation: .............................................................................................................................................................. 11
Document # 20-325-018-01 Rev IR
Page 3 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.16 SM5-MC Operation: ................................................................................................................................................................ 11
3.17 TEL-MC Installation: ................................................................................................................................................................ 12
3.18 TEL-MC Operation: .................................................................................................................................................................. 12
3.19 WT-MC Installation: ................................................................................................................................................................ 12
3.20 WT-MC OPERATION: ............................................................................................................................................................... 12
Document # 20-325-018-01 Rev IR
Page 4 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
SECTION 1:
INTRODUCTION
1.1 PURPOSE:
This document contains information relative to the installation and operation characteristics of the Silent
Call Medallion Series SCXMIT10 Consolidated Transmitter configurations.
SECTION 2:
SYSTEM DESCRIPTION
2.1 KEY FEATURES:
The Silent Call SCXMIT10Transmitter Medallion Series is a configurable 418Mhz Transmitter to be
used in conjunction with the Medallion Series Receivers. The consolidated transmitter can be configured
into 10 different transmitter types depending upon the customer requirements. The following is a list of
configuable 418Mhz consolidated transmitters.
 BM418-MC—Bed Mat Transmitter
 DB2-MC -- Doorbell Transmitter (with remote button)
 DB41-MC—Doorbell Transmitter
 DW3-MC– Door/Window access Transmitter
 FA3-MC --Fire Alarm Transmitter (contact input)
 FA41-MC --Fire Alarm Transmitter (Battery w/voltage)
 MAT4-MC – TransMatter Transmitter
 SM5-MC– Sound Monitor Transmitter
 TEL-MC– Telephone Transmitter
 WT-MC– Weather Alert Transmitter
2.2 CONSOLIDATED TRANSMITTER (FA3-MC) SPECIFICATIONS:
FA3-MC Mass:
.14 kilograms w/batteries
FA3-MC Dimensions:
Length = 115 mm
Width = 62 mm
Height = 28 mm
Operating Voltage:
3volts DC
2 AA Panasonic LR6WXA
Current Draw:
.04 milliamps Idle CONT.
8.3 milliamps during Alert
FCC ID:
PPJ-SCXMIT10
IC:
4498A-SCXMIT10
Document # 20-325-018-01 Rev IR
Page 5 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
2.3 REGLATORY INFORMATION NOTICE:
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
This Device Complies With Industry Canada License-Exempt Rss Standard(S).
Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation of the device. This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver
• Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
• Consult the dealer or an experienced radio/television technician for help
Unauthorized changes or modifications could void the user’s authority
to operate the equipment.
2.4 TRANSMITTER FEATURES:
SCXMIT10 transmitters are battery operated and will flash a YELLOW LED when the batteries are in
need of replacement. Transmitter has a test button for programming to receivers and required follow on
operational testing The RED LED will illuminate when the transmitter is actively transmitting signal to
the intended receiver.
2.5 TRANSMITTER SETTINGS:
The Silent Call Medallion Series address system is digitally encoded. All Silent Call Medallion Series
receivers are capable of receiving one million different address codes. Each Medallion Series
Transmitters has a unique code preprogrammed during manufacturing. Please refer to your receiver
manual for instruction on programming the transmitter code to the receiver.
2.6 REPLACEMENT BATTERIES:
Transmitter uses two AA 1.5V Alkaline Batteries. AA Batteries may be purchased from local retail
stores. Transmitter is shipped with 2 Rayovac Alkaline Batteries Type LR6. FA3-MC and FA41-MC
configured transmitter are certified with AA Panasonic LR6WXA batteries only. It is recommended
transmitter batteries be changed once a year and checked weekly.
2.7 TRANSMITTER MOUNTING AND LOCATION:
The Consolidated Transmitter Medallion Series Transmitter is designed for indoor use only. The
transmitter case has provisions for mounting to a nail or screw on the wall or use provided Velcro for
mounting on desktop or wall. Avoid mounting transmitter near large metal objects, other transmitting
devices in close proximity or high current appliances that will degrade the transmitter / receiver operation.
Test transmitter mounting location with receiver before mounting to ensure proper system operation.
Adjust antenna for best results Transmission range with a Silent Call Medallion Series transmitter is about
500 feet.
Document # 20-325-018-01 Rev IR
Page 6 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
SECTION 3: CONFIGURED TRANSMITTER INSTRUCTIONS
3.1 BM418-MC INSTALLATION:
1.
2.
3.
Place the bed mat under the sheet on the bed in the area of where the users back will lay.
Allow the wire and transmitter to hang over the head of the bed so that the user is not lying on either part or does not trip on
the wire when getting out of bed.
The transmitter is connected to the Bed Mat and must not be mounted directly to a metallic surface. Doing so will severely
reduce the range of the transmitter.
3.2 BM418-MC OPERATION:
1.
2.
3.
4.
When someone is lying on the bed mat it will not transmit. The user can roll around and it will not transmit.
The transmitter will activate once the person gets up out of bed and pressure is removed from the mat.
Medallion Series Receiver strobe will activate and illuminate the door LED Icon. The Receiver will indicate alert for 16
seconds. Repeat steps 1 and 2 for system to re-alert.
Quick reference Document # 109101.
CAUTION:
When handling or shipping the Bed Mat Transmitter, do not bend the mat sharply or fold
it. It must be kept flat or rolled loosely or it will be damaged.
3.3 DB2-MC INSTALLATION:
1.
2.
3.
4.
Decide where to mount the transmitter on an inside wall near the location for the button.
Drill a hole in the wall behind where the transmitter will mount.
Pass the wires from the transmitter through the hole and connect them to the terminals in the button.
Install the button on the outside wall covering the hole.
3.4 DB2-MC OPERATION:
1.
2.
3.
When the remote button is pressed, the Red LED on the face of the transmitter will light up. The transmitter will then send a
signal to any Silent Call Medallion Series Receiver activating the receiver.
Release the Doorbell button and the transmissions will cease.
Quick reference Document # 109105
Document # 20-325-018-01 Rev IR
Page 7 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.5 DB41-MC INSTALLATION:
1.
2.
3.
4.
5.
6.
Locate your doorbell chime unit and remove the cover.
Inside the chime unit, locate the terminal block with three terminals marked FRONT, REAR and TRANS.
Loosen the two screws but do not disconnect the attached wires.
Attach the two wires from the DB41-MC as follows: Red to FRONT, yellow to REAR.
Tighten the two screws and tuck and excess wires out of sight. Make sure all wires are clear of the chime mechanism.
Replace the chime box cover.
7. Other applications are possible. The DB41-MC will activate when it is connected to a source of voltage between 12V and
24V AC or DC.
3.6 DB41-MC OPERATION:
1.
2.
3.
Whenever the front (or rear, if used) doorbell button is pressed, the chimes will sound as usual, the Red LED on the face of
the doorbell transmitter will light up and the transmitter will send a signal to any Silent Call Medallion Series Receiver
activating the receiver.
Both the front and rear doorbell buttons will activate the doorbell transmitter.
Quick reference Document # 109109
3.7 DW3-MC INSTALLATION:
1.
2.
Mount the magnet on the door or window so that it clears the door jamb or window frame and does not interfere with normal
door or window operation.
Mount the magnetic switch so that it is as close to the magnet as possible when the door or window is closed. Spacing should
be less than approximately ¼”.
3.8 DW3-MC OPERATION:
1.
2.
When the door or window moves enough that the magnet is separated from the switch, the red LED on the transmitter will
light up. The transmitter will then send a signal to any Silent Call Medallion Series Receiver activating the receiver. The
transmitter will transmit for approximately five seconds and then stop until the door or window is closed. The door or
window must be closed for approximately five seconds before the transmitter will reset and be ready to activate again.
Quick reference Document # 109111.
Document # 20-325-018-01 Rev IR
Page 8 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.9 FA3-MC INSTALLATION:
Please contact a licensed fire alarm installer for installation and working with this product. Improper installation can damage
your fire alarm and/or prevent proper operation of the fire alarm. Technical support is available at (800) 572-5227.
The FA3-MC in conjunction with a Silent Call Medallion Series receiver is considered an
Supplementary Visible Notification Appliance.
The FA3-MC is designed to interface with a dry contact output. It will transmit as long as the contact is closed and will stop
transmitting when the contact opens.
1. Do not mount inside of the alarm panel box! The metal of the box will detune the transmitter.
2. Connect Red and Black wire Spade terminals to Open/Unused Form A /Form C relay contacts. Contact closure activates
transmitter. Damage to Transmitter will occur if connected to any voltage source
3. Reference Silent Call FA3-MC Installation Drawing 20-300-021-01FA3.
3.10 FA3-MC OPERATION:
1.
2.
3.
The FA3-MC will transmit as long as the Red and Black wire spade terminals are connected. When the activating contacts
are closed, the Red LED on the face of the transmitter will light up. The transmitter will then send a signal to any Silent Call
Medallion Series Receiver activating the receiver.
FA3-MC will stop transmitting when Alarm is reset and alarm contacts are opened.
Quick reference Document # 1098113.
3.11 FA41-MC INSTALLATION:
Please contact a licensed fire alarm installer for installation and working with this product. Improper installation can damage
your fire alarm and/or prevent proper operation of the fire alarm. Technical support is available at (800) 572-5227.
The FA41-MC in conjunction with a Silent Call Medallion Series receiver is considered an
Supplementary Visible Notification Appliance.
The FA41-MC is designed to interface with a voltage input. It will transmit as long as the voltage is positive and will stop
transmitting when the voltage reverses polarity or ceases.
1. Do not attach inside of the alarm panel box! The metal of the box will detune the transmitter.
2. Connect Red and Black wire Spade terminals to Alarm Panel NAC Circuit or circuit with a positive voltage for alert.
3. Alert Voltage 12VDC to 24VDC.
4. Reference Silent Call FA41-MC Installation Drawing 20-300-023-01FA41.
3.12 FA41-MC OPERATION:
1.
2.
3.
The FA41-MC will transmit as long as positive polarity voltage is applied to the Red and Black wire spade terminals. When
positive voltage is present, the Red LED on the face of the transmitter will light up. The transmitter will then send a signal to
any Silent Call Medallion Series Receiver activating the receiver.
FA41-MC will stop transmitting when Alarm is reset and positive polarity is reversed or voltage is removed.
Quick reference Document # 109155.
Document # 20-325-018-01 Rev IR
Page 9 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.13 MAT4-MC INSTALLATION:
1.
2.
3.
Place the mat where it will be stepped on anywhere except the very edge. The water resistant material used to manufacture
the TransMATTer is required to have a protective cover over it; this would usually consist of a door rug or similar covering.
The transmitter that is connected to the TransMATTer must not be mounted directly to a metallic surface. Doing so will
severely reduce the range of the transmitter.
The TransMATTer is intended for indoor use only.
3.14 MAT4-MC OPERATION:
1. Whenever the mat is stepped on, the Red LED on the face of the TransMATTer Medallion Series transmitter will
light up. The transmitter then sends a signal to any Medallion Series Receiver, activating the Receiver as a
Doorbell Alert.
2. If pressure is maintained, the transmitter will continue to transmit. Transmitter will stop transmitting when
pressure is removed from the mat.
3. Quick reference Document # 109117.
CAUTION:
When handling or shipping the TransMATTer, do not bend the mat sharply or fold it. It
must be kept flat or rolled loosely or it will be damaged.
Document # 20-325-018-01 Rev IR
Page 10 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.15 SM5-MC INSTALLATION:
Please read all of the instructions thoroughly before using your Sound Monitor.
1.
2.
3.
Remove your Sound Monitor from the packaging.
Place the Sound Monitor as close to the sound source as possible that you want to monitor (but not within a baby’s reach).
For example, place it on a dresser next to a baby’s bed or next to a telephone, alarm clock or apartment doorbell speaker.
The Sound Monitor can be mounted to any flat surface with the supplied Velcro strips or you can hang it on a wall using the
access hole on the back of the case. This step is not necessary if you will be moving the Sound Monitor from location to
location.
3.16 SM5-MC OPERATION:
1.
2.
3.
4.
5.
6.
Slide the on/off switch on the side of the Sound Monitor to the ON position.
Any continuous loud sound will cause the Sound Monitor to activate and the Red LED on the face of the transmitter will
come on. The transmitter then sends a wireless signal, to any Silent Call Medallion Series Receiver activating the receiver.
The Sound Monitor is designed so that brief sounds such as door slams, regardless of how loud they are, will not activate the
Sound Monitor.
The Sound Monitor leaves the factory set to 50% sensitivity, which should be adequate for almost all situations. If for some
reason the sensitivity needs to be changed, there is an adjustment dial located behind the battery door. Rotating the
adjustment dial clockwise increases the sensitivity.
A new feature of the Sound Monitor is the ability to set the Sound Monitor to detect a specific sound. Remove the battery
cover and at the bottom left hand corner there is a 3 position switch. Switch # 1 ON is for Sound Alert, Switch #2 ON is for
Telephone Alert and Switch # 3 ON is for Doorbell Alert.
Quick reference Document # 109119.
Shown set to Sound “Switch 1 ON”
Document # 20-325-018-01 Rev IR
Page 11 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.17 TEL-MC INSTALLATION:
1. The telephone transmitter will work with standard telephone lines and with most video phone RJ-45 outputs.
2. To install the TEL-MC telephone transmitter on a conventional telephone line, plug the telephone transmitter
into any telephone outlet. Use the supplied dual adapter if you need to connect a telephone AND the transmitter
to the same outlet.
3. To install the TEL-MC telephone transmitter on a videophone, plug the telephone transmitter into the
telephone outlet on the videophone. Use the supplied dual adapter if you need to connect a telephone AND the
transmitter to the videophone.
4. If plugged into a two line telephone outlet, the telephone transmitter will respond to line one only.
5. The TEL-MC transmitter may not work with digital phone systems. Please contact your telephone service
provider as filters may be necessary to filter out the modem tones associated with digital (DSL) or VOIP type
services.
3.18 TEL-MC OPERATION:
1. Whenever the telephone (or videophone) rings, the Red light on the telephone transmitter will light up and the
transmitter will send a signal to your Silent Call Medallion Series Receiver causing the receiver to activate Phone
Alert.
2. Quick reference Document # 109121.
Connect TEL-MC to Dual Adapter
3.19 WT-MC INSTALLATION:
1.
2.
3.
The WT-MC Weather Alert Transmitter is designed to interface with a variety Weather Alert radios that include a normally
open (or open collector) output.
Transmitter connector mates with standard female 3.5mm WX Radio output jack.
Plug the cord on the weather transmitter into the alarm output jack located on the rear panel of the weather radio.
3.20 WT-MC OPERATION:
1. The WT-MC Weather Alert Transmitter will transmit as long as the weather receiver maintains the alert output and will stop
transmitting when the alert output goes back to normal.
2. Quick reference Document # 109123.
Document # 20-325-018-01 Rev IR
Page 12 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
Technical Support
For technical support on this or any other Silent Call product, please feel free to contact us. You can reach us by phone at 800572-5227 (voice or TTY) or by Email at support@silentcall.com
CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE
MANUFACTURER COULD VOID THE USER'S AUTHORITY TO OPERATE THE
EQUIPMENT.
Limited Warranty
Your transmitter is warranted to be free of defects in material and workmanship for five years from the date of initial purchase.
During that time, the unit will be repaired or replaced free of charge when shipped prepaid to Silent Call Communications. This
warranty is void if the defect is caused by customer abuse or neglect.
Return for Serving To:
Silent Call Communications
5095 Williams Lake Road, Waterford Michigan 48329
(800) 572-5227 v/tty (248) 673-7360 fax
Website: www.silentcall.com Email: silentcall@silentcall.com
Document # 20-325-018-01 Rev IR
Page 13 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
SCXMIT10 418Mhz Consolidé Émetteur Série
Instructions D'Installation
Traduction Français
TABLE DES MATIÈRES
SECTION 1:
INTRODUCTION.................................................................................................................................. 16
1.1 OBJECTIF: ................................................................................................................................................................................. 16
SECTION 2:
DESCRIPTION DU SYSTÈME ........................................................................................................... 16
2.1 CARACTÉRISTIQUES PRINCIPALES: ........................................................................................................................................... 16
2.2 SPÉCIFICATIONS DE L'ÉMETTEUR CONSOLIDÉ (FA3-MC): .......................................................................................................... 16
2.3 AVIS D'INFORMATION REGLATORY: .......................................................................................................................................... 17
2.4 CARACTÉRISTIQUES DE L'ÉMETTEUR: ........................................................................................................................................ 17
2.5 PARAMÈTRES DE L'ÉMETTEUR: ................................................................................................................................................. 17
2.6 PILES DE RECHANGE: ................................................................................................................................................................. 17
2.7 EMPLACEMENT ET MONTAGE DE L'ÉMETTEUR: ......................................................................................................................... 17
SECTION 3: INSTRUCTIONS DE L'ÉMETTEUR CONFIGURÉ ............................................................................. 18
3.1 INSTALLATION DE BM418-MC: .................................................................................................................................................. 18
3.2 BM418-MC OPÉRATION: ........................................................................................................................................................... 18
3.3 INSTALLATION DE DB2-MC:....................................................................................................................................................... 18
3.4 DB2-MC OPÉRATION: ................................................................................................................................................................ 18
3.5 INSTALLATION DE DB41-MC:..................................................................................................................................................... 19
3.6 DB41-MC OPÉRATION: .............................................................................................................................................................. 19
3.7 INSTALLATION DE DW3-MC: ..................................................................................................................................................... 19
3.8 DW3-MC OPÉRATION: .............................................................................................................................................................. 19
Document # 20-325-018-01 Rev IR
Page 14 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.9 INSTALLATION DE FA3-MC: ....................................................................................................................................................... 20
3.10 FA3-MC OPÉRATION: .............................................................................................................................................................. 20
3.11 INSTALLATION DE FA41-MC: ................................................................................................................................................... 20
3.12 FA41-MC OPÉRATION: ............................................................................................................................................................ 20
3.13 INSTALLATION DE MAT4-MC: .................................................................................................................................................. 21
3.14 MAT4-MC OPÉRATION: ........................................................................................................................................................... 21
3.15 INSTALLATION DE LA SM5-MC: ............................................................................................................................................... 22
3.16 SM5-MC OPÉRATION: ............................................................................................................................................................. 22
3.17 INSTALLATION DE TÉL-MC: ...................................................................................................................................................... 23
3.18 TEL-MC OPÉRATION: ............................................................................................................................................................... 23
3.19 WT-MC Installation: ................................................................................................................................................................ 23
3.20 WT-MC OPÉRATION: ............................................................................................................................................................... 23
Document # 20-325-018-01 Rev IR
Page 15 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
SECTION 1:
INTRODUCTION
1.1 OBJECTIF:
Ce document contient des informations relatives à des caractéristiques installation et l'utilisation des
configurations de silencieux appeler médaillon série SCXMIT10 Consolidated émetteur.
SECTION 2:
DESCRIPTION DU SYSTÈME
2.1 CARACTÉRISTIQUES PRINCIPALES:
La série Silent Call SCXMIT10Transmitter médaillon est un configurable 418 Mhz transmetteur pour
être utilisé en conjonction avec les récepteurs de la gamme Medallion. L'émetteur consolidée peut être
configuré en 10 types d'émetteur différent selon les exigences du client. Voici une liste des émetteurs de
418Mhz consolidé configurable.
 BM418-MC-- Lit Matelas Émetteur.
 DB2-MC -- Émetteur de Sonnette de Porte (avec la touche de la télécommande)
 DB41-MC— Émetteur de Sonnette de Porte
 DW3-MC– Accès de Porte/Fenêtre Émetteur
 FA3-MC -- Transmetteur D'alarme D'incendie (entrée contact)
 FA41-MC -- Transmetteur D'alarme D'incendie (batterie avec tension)
 MAT4-MC – TransMatter Émetteur
 SM5-MC– Surveiller son Émetteur
 TEL-MC– Transmetteur Téléphonique
 WT-MC– Transmetteur Alerte Météo
2.2 SPÉCIFICATIONS DE L'ÉMETTEUR CONSOLIDÉ (FA3-MC):
FA3-MC Mass:
.14 kilograms w/batteries
FA3-MC Dimensions:
Length = 115 mm
Width = 62 mm
Height = 28 mm
Operating Voltage:
3volts DC
2 AA Panasonic LR6WXA
Current Draw:
.04 milliamps Idle CONT.
8.3 milliamps during Alert
FCC ID:
PPJ-SCXMIT10
IC:
4498A-SCXMIT10
Document # 20-325-018-01 Rev IR
Page 16 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
2.3 AVIS D'INFORMATION REGLATORY:
CET APPAREIL EST CONFORME À LA PARTIE 15 DES RÈGLES FCC.
Cet Appareil Est Conforme Avec Industrie Canada Exemptes De Licence RSS Ou Les Normes.
Son fonctionnement est sujet aux deux conditions suivantes: (1) cet appareil ne doit pas émettre de
brouillage nuisible, et (2) cet appareil doit accepter toute interférence reçue, y compris les
interférences pouvant entraîner un fonctionnement indésirable du dispositif. Cet équipement a été
testé et déclaré conforme aux limites d'un appareil numérique de classe B, conformément à l'article
15 des règlements FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les
interférences nuisibles dans une installation résidentielle. Cet équipement génère, utilise et peut
émettre de l'énergie de fréquence radio et si pas installé et utilisé conformément aux instructions,
peut causer des interférences nuisibles aux communications radio. Cependant, il n'y a aucune
garantie que des interférences n'interviendront pas dans une installation particulière. Si cet
équipement provoque des interférences nuisibles à la réception radio ou télévision, ce qui peut être
déterminée en éteignant et rallumant l'équipement, l'utilisateur est encouragé à essayer de corriger
ces interférences en appliquant une ou plusieurs des mesures suivantes: • Réorientez ou déplacez
l'antenne de réception.
• Augmenter la distance entre l'équipement et le récepteur
• Branchez l'appareil dans une prise sur un circuit différent de celui auquel le récepteur est
branché.
• Consultez le revendeur ou un technicien expérimenté en radio/télévision pour aide
Toute modification non autorisée pourrait annuler autorisation votre d'utiliser l'équipement.
2.4 CARACTÉRISTIQUES DE L'ÉMETTEUR:
SCXMIT10 émetteurs sont batterie exploité et fait clignoter une LED jaune lorsque les piles doivent être
remplacées. Émetteur dispose d'un bouton de test pour la programmation à des récepteurs et requis suivi
opérationnel essai the red led s'allume lorsque l'émetteur transmet activement signal au récepteur prévu.
2.5 PARAMÈTRES DE L'ÉMETTEUR:
Le système d'adresses Silent Call médaillon série est codé numériquement. Tous les récepteurs de la
série de médaillon Silent Call sont capables de recevoir 1 million de codes adresse différente. Chaque
médaillon émetteurs de la série a un code unique programmé pendant la fabrication. Veuillez vous
référer au manuel de votre récepteur pour la formation sur la programmation du code de l'émetteur au
récepteur.
2.6 PILES DE RECHANGE:
Émetteur utilise deux piles AA 1.5V piles alcalines. Piles AA peuvent être achetés dans le commerce
local. Émetteur est livré avec 2 Rayovac Piles alcalines piles Type LR6. SA3-MC et émetteur de FA41MC configuré sont certifiés avec des piles AA Panasonic LR6WXA seulement. Il est recommandé de
piles de l'émetteur soit changés une fois par an et contrôlés toutes les semaines.
2.7 EMPLACEMENT ET MONTAGE DE L'ÉMETTEUR:
La Consolidated médaillon série l'émetteur est conçu pour une utilisation en intérieur uniquement. Le
cas de l'émetteur comporte des dispositions pour le montage sur un clou ou une vis sur le mur ou l'usage
prévu de Velcro pour un montage sur bureau ou murale. Éviter l'émetteur de montage près de grands
objets métalliques, autres appareils de transmission à proximité ou hautes appareils actuels qui vont se
dégrader l'émetteur / récepteur fonctionnement. L'emplacement de montage émetteur avec récepteur
avant le montage afin d'assurer le bon fonctionnement du système d'essai. Régler l'antenne pour de
meilleurs résultats, portée de Transmission avec un émetteur de la série de médaillon Silent Call est
d'environ 500 pieds.
Document # 20-325-018-01 Rev IR
Page 17 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
SECTION 3: INSTRUCTIONS DE L'ÉMETTEUR CONFIGURÉ
3.1 INSTALLATION DE BM418-MC:
1.
2.
3.
Placez le tapis sous le drap sur le lit dans la zone d'où les utilisateurs retour déposera.
Laissez le fil et l'émetteur à accrocher au-dessus de la tête du lit, afin que l'utilisateur n'est pas couché sur une ou l'autre
partie ou ne se déclenche pas sur le fil quand sortir du lit.
L'émetteur est relié à la natte du lit et ne doit pas être monté directement sur une surface métallique. Cela réduira fortement
la portée de l'émetteur.
3.2 BM418-MC OPÉRATION:
1.
2.
3.
4.
Lorsque quelqu'un est couché sur le tapis, il ne transmet pas. L'utilisateur peut rouler, et il n'émet pas.
L'émetteur sera activée une fois que la personne se lève du lit et la pression est supprimée de la natte.
Stroboscope de récepteur de la série médaillon activera et illuminer la porte icône LED. Le récepteur affiche alerte pendant
16 secondes. Répétez les étapes 1 et 2 pour le système à nouveau attirer l'attention.
Quick reference Document # 109101.
ATTENTION : Lors de manipulation ou une expédition de l'émetteur de tapis de lit, ne pas plier le tapis
brusquement ou plier. Il faut garder plat ou roulé lâchement ou il sera endommagé.
3.3 INSTALLATION DE DB2-MC:
1.
2.
3.
4.
Décider où monter l'émetteur à un intérieur mur près de l'emplacement du bouton.
Percer un trou dans le mur derrière laquelle l'émetteur sera montée.
Faites passer les fils de l'émetteur dans le trou et les raccorder aux bornes du bouton.
Installez le bouton sur le mur extérieur couvrant le trou.
3.4 DB2-MC OPÉRATION:
1.
2.
3.
Lorsque vous appuyez sur la touche de la télécommande, la LED rouge sur le visage de l'émetteur s'allume. L'émetteur
enverra alors un signal à n'importe quel récepteur silencieux de série médaillon appeler en activant le récepteur.
Relâchez que le bouton de la sonnette et les transmissions cesseront.
Quick reference Document # 109105
Document # 20-325-018-01 Rev IR
Page 18 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.5 INSTALLATION DE DB41-MC:
1.
2.
3.
4.
5.
6.
7.
Repérez votre carillon sonnette et enlever le couvercle.
À l'intérieur de l'unité de carillon, placer la plaque à bornes avec trois bornes avant, arrière et TRANS.
Desserrez les deux vis mais ne pas déconnecter les câbles attachés.
Attachez les deux fils de la DB41-MC comme suit : rouge vers l'avant, jaune à l'arrière.
Serrer les deux vis et les tuck et les excès fils hors de la vue. Assurez-vous que tous les fils sont libres du mécanisme du
carillon.
Replacez le couvercle de boîte de carillon.
Autres applications sont possibles. DB41-MC s'active lorsqu'il est connecté à une source de tension entre 12V et 24V AC ou
DC.
3.6 DB41-MC OPÉRATION:
1.
2.
3.
Chaque fois que l'avant (ou arrière, si utilisée) vous appuyez sur le bouton de sonnette, le carillon retentit comme d'habitude,
la LED rouge sur le visage de l'émetteur de sonnette de porte s'allume et l'émetteur enverra un signal à n'importe quel
récepteur silencieux de série médaillon appellent à l'activation du récepteur.
Les boutons de sonnette de porte arrière et avant pour activer l'émetteur de sonnette de porte.
Quick reference Document # 109109
3.7 INSTALLATION DE DW3-MC:
1.
2.
Monter l'aimant sur la porte ou la fenêtre afin qu'il efface le chambranle du montant ou de la fenêtre et n'interfère pas avec le
fonctionnement normal de porte ou une fenêtre.
Montez l'interrupteur magnétique de sorte que c'est aussi à proximité de l'aimant comme possible lorsque la porte ou la
fenêtre est fermée. Espacement doit être inférieur à environ ¼ po.
3.8 DW3-MC OPÉRATION:
1.
2.
Lorsque la porte ou la fenêtre se déplace assez que l'aimant est séparée de l'interrupteur, la LED rouge sur l'émetteur s'allume.
L'émetteur enverra alors un signal à n'importe quel récepteur silencieux de série médaillon appeler en activant le récepteur.
L'émetteur transmettront pendant environ cinq secondes et puis s'arrête jusqu'à ce que la porte ou la fenêtre est fermée. La
porte ou la fenêtre doit être fermée pendant environ cinq secondes avant que l'émetteur se réinitialise et être prêt à activer à
nouveau.
Quick reference Document # 109111.
Document # 20-325-018-01 Rev IR
Page 19 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.9 INSTALLATION DE FA3-MC:
Pour l'installation et l'utilisation de ce produit, veuillez communiquer avec un installateur d'alarme incendie sous licence.
Une installation incorrecte peut endommager votre alarme incendie et/ou empêcher le bon fonctionnement de l'alarme.
incendie. Le support technique est disponible au (800) 572-5227.
Le FA3-MC en conjonction avec un récepteur de la série de médaillon Silent Call est considéré
comme un appareil de signal Visible supplémentaire.
Le SA3-MC est conçu pour s'interfacer avec une sortie contact sec. Il transmettra aussi longtemps que le contact est fermé et
va arrêter la transmission lorsque le contact s'ouvre.
1. Ne pas monter à l'intérieur de la boîte de panneau d'alarme ! Le métal de la boîte se désaccorder l'émetteur.
2. Branchez rouge et noir fil bornes embrochables pour ouvert/inutilisés contacts relais de forme A /Form C. Fermeture de
contact Active émetteur. Si connecté à n'importe quelle source de tension subira des dommages à l'émetteur.
3. Renvoi appel silencieux FA3-MC Installation dessin 20-300-021-01FA3
3.10 FA3-MC OPÉRATION:
1.
2.
3.
Le SA3-MC transmettra aussi longtemps que les bornes embrochables de fil rouge et le noir sont connectés. Lorsque le
déclencheur est fermé, la LED rouge sur le visage de l'émetteur s'allume. L'émetteur enverra alors un signal à n'importe quel
récepteur silencieux de série médaillon appeler en activant le récepteur.
SA3-MC va arrêter la transmission lorsque réinitialisée et contacts d'alarme sont ouverts.
Quick reference Document # 1098113.
3.11 INSTALLATION DE FA41-MC:
Pour l'installation et l'utilisation de ce produit, veuillez communiquer avec un installateur d'alarme incendie sous licence.
Une installation incorrecte peut endommager votre alarme incendie et/ou empêcher le bon fonctionnement de l'alarme.
incendie. Le support technique est disponible au (800) 572-5227.
Le FA3-MC en conjonction avec un récepteur de la série de médaillon Silent Call est considéré
comme un appareil de signal Visible supplémentaire.
Le FA41-MC est conçu pour s'interfacer avec une tension d'entrée. Il transmettra aussi longtemps que la tension est positive
et s'arrête à transmettre lorsque la tension inverse de polarité ou cesse.
1. Ne pas fixer à l'intérieur de la boîte de panneau d'alarme ! Le métal de la boîte se désaccorder l'émetteur.
2. Connectez le fil rouge et noir spade bornes d'alarme panneau du cna ou circuit avec une tension positive pour l'alerte.
3. Alerte tension 12vdc à 24vdc.
4. Schéma d'installation silencieuse d'appel fa41-mc 20-300-023-01fa41 de référence.
3.12 FA41-MC OPÉRATION:
1.
2.
3.
Le FA41-MC transmettra aussi longtemps que la polarité positive avec une tension est appliquée aux bornes de cosse du fil
rouge et noir. Lorsqu'il est positif de tension, la LED rouge sur le visage de l'émetteur s'allume. L'émetteur enverra alors un
signal à n'importe quel récepteur silencieux de série médaillon appeler en activant le récepteur.
FA41-MC va arrêter la transmission lorsque réinitialisée et polarité positive est inversée ou tension est supprimée.
Quick reference Document # 109155.
Document # 20-325-018-01 Rev IR
Page 20 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.13 INSTALLATION DE MAT4-MC:
1.
Poser le tapis où il va être piétiné n'importe où sauf au bord. Le matériau résistant à l'eau utilisé pour la fabrication de la
transmatter doit avoir un couvercle de protection au-dessus de lui ; cela comprendrait généralement un tapis de porte ou un
revêtement semblable.
2. L'émetteur connecté à la transmatter ne doit pas être monté directement sur une surface métallique. Cela réduira fortement la
portée de l'émetteur.
3. Le transmatter est prévu pour une utilisation en intérieur uniquement.
3.14 MAT4-MC OPÉRATION:
1.
2.
3.
Chaque fois que le tapis est piétiné, la LED rouge sur le visage de l'émetteur TRANSMATTER médaillon série s'allume.
L'émetteur puis envoie un signal à n'importe quel récepteur de la série médaillon, activant le récepteur, comme une alerte de
sonnette.
Si la pression est maintenue, l'émetteur continuera à transmettre. Émetteur s'arrêtera transmettant lorsque la pression est
supprimée de la natte.
Quick reference Document # 109117.
ATTENTION : Lors de manipulation ou une expédition de la TransMATTer, ne pas plier le tapis
brusquement ou plier. Il faut garder plat ou roulé lâchement ou il sera endommagé.
Document # 20-325-018-01 Rev IR
Page 21 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.15 INSTALLATION DE LA SM5-MC:
Veuillez lire toutes les instructions attentivement avant d'utiliser votre moniteur de sons.
1. Retirez votre moniteur de sons de l'emballage.
2. Placer le témoin sonore aussi près de la source sonore que possible que vous souhaitez surveiller (mais
pas dans la portée d'un bébé). Par exemple, placez-le sur une commode à côté du lit de bébé ou à côté
d'un téléphone, le réveil ou le haut-parleur sonnette appartement.
3. Le témoin sonore peut être monté sur n'importe quelle surface plane avec les bandes Velcro fournis ou
vous pouvez l'accrocher sur un mur à l'aide de l'orifice d'accès sur l'arrière du boîtier. Cette étape n'est
pas nécessaire si vous envisagez de déplacer à l'écran de son d'un endroit à l'autre.
3.16 SM5-MC OPÉRATION:
1. Faites glisser l'interrupteur marche/arrêt sur le côté de l'écran de son sur la position ON.
2. N'importe quel bruit continu fera le témoin sonore activer et la LED rouge sur le visage de l'émetteur
s'allume. L'émetteur envoie ensuite un signal sans fil, à n'importe quel silence appeler médaillon série
récepteur activant le récepteur.
3. Le témoin sonore est conçu pour que les sons brefs comme slams porte, comment fort, qu'ils soient, ne
seront activera pas le moniteur Sound.
4. Le témoin sonore quitte l'usine réglé à sensibilité de 50 %, ce qui devrait suffire pour presque toutes les
situations. Si pour une raison quelconque la sensibilité doit être changée, il y a une molette de réglage
située derrière la porte de la batterie. Tournez la molette de réglage dans le sens horaire, vous
augmenterez la sensibilité.
5. Une nouvelle fonctionnalité du moniteur sonore est la possibilité de définir le contrôle de tonalité pour
détecter un son particulier. Enlevez la batterie et au coin inférieur gauche, il y a un interrupteur à 3
positions. Interrupteur # 1 ON est pour l'alerte sonore, interrupteur #2 ON pour téléphone alerte et
interrupteur # 3 ON est pour sonnette alerte.
6. Quick reference Document # 109119.
Shown set to Sound “Switch 1 ON”
Document # 20-325-018-01 Rev IR
Page 22 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
3.17 INSTALLATION DE TÉL-MC:
1. Le transmetteur téléphonique collaborera avec les lignes téléphoniques standard et avec la plupart des produits de
vidéo sur téléphone RJ-45.
2. Pour installer le transmetteur téléphonique TEL-MC sur une ligne téléphonique classique, branchez le
transmetteur téléphonique dans une prise de téléphone. Utiliser l'adaptateur en double si vous avez besoin de
brancher un téléphone et l'émetteur sur la même prise.
3. Pour installer le transmetteur téléphonique TEL-MC sur un visiophone, branchez le transmetteur téléphonique
dans la prise de téléphone sur le visiophone. Utiliser l'adaptateur en double si vous avez besoin de brancher un
téléphone et l'émetteur pour le visiophone.
4. S'il est branché sur une prise de téléphone à 2 lignes, le transmetteur téléphonique répondra à la ligne une seule.
5. L'émetteur TEL-MC peut ne pas fonctionner avec les systèmes de téléphonie numérique. Veuillez contacter votre
fournisseur de services téléphoniques comme filtres peuvent être nécessaires pour filtrer les tons modem associés
à numérique (DSL) ou services de type VOIP.
3.18 TEL-MC OPÉRATION:
1. Chaque fois que le téléphone (ou visiophone) sonne, le voyant rouge sur le transmetteur téléphonique s'allumera
et l'émetteur enverra un signal à votre récepteur silencieux de série médaillon appeler causant le récepteur activer
le téléphone alerte.
2. Quick reference document # 109121.
Se Connecter TEL-MC Adaptateur Double
3.19 WT-MC INSTALLATION:
1.
2.
3.
L'émetteur alerte météo de WT-MC est conçu pour s'interfacer avec une variété alerte météo radios qui incluent un
normalement ouvert (ou collecteur ouvert) sortie.
L'émetteur connecteur accouplé à femelle standard 3,5 mm jack de sortie Radio WX.
Branchez le cordon sur l'émetteur de la météo sur la prise de sortie d'alarme située sur le panneau arrière de la radio-météo.
3.20 WT-MC OPÉRATION:
1.
2.
L'émetteur WT-MC d'alerte météo transmettra aussi longtemps que le récepteur météo maintient l'alerte de sortie et s'arrêtera
à transmettre lors de la sortie d'alerte remonte à la normale.
Quick reference Document # 109123
Document # 20-325-018-01 Rev IR
Page 23 of 24
Silent Call Communications
SCXMIT10 418Mhz Consolidated Transmitter Installation Document
Support Technique
Pour le support technique à ce sujet ou tout autre produit d'appel silencieux, s'il vous plaît n'hésitez pas à nous contacter. Vous pouvez
nous joindre par téléphone au 800-572-5227 (voix ou TTY), ou par courriel à support@silentcall.com
LES CHANGEMENTS OU MODIFICATIONS NON EXPRESSÉMENT APPROUVÉS PAR LE FABRICANT PEUVENT
ANNULER AUTORISATION VOTRE D'UTILISER L'ÉQUIPEMENT.
Garantie Limitée
Votre émetteur est garanti exempt de tout vice de matériau et de fabrication pendant cinq ans suivant la date d'achat initiale. Pendant
ce temps, l'appareil sera réparé ou remplacé gratuitement lors de l'expédition prépayée à Silent Call Communications. Cette garantie
est nulle si le défaut est causé par la mauvaise utilisation ou négligence.
Retour pour le service à:
Silent Call Communications
5095 Williams Lake Road, Waterford Michigan 48329
(800) 572-5227 v/tty (248) 673-7360 fax
Website: www.silentcall.com Email: silentcall@silentcall.com
Document # 20-325-018-01 Rev IR
Page 24 of 24
Silent Call Communications

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 24
Language                        : en-US
Tagged PDF                      : Yes
Title                           : O&M Manual Template
Author                          : HHS EPLC Team
Subject                         : 
Keywords                        : EPLC, Template
Creator                         : Microsoft® Word 2010
Create Date                     : 2016:02:08 14:14:09-05:00
Modify Date                     : 2016:02:08 14:14:09-05:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PPJ-SCXMIT10

Navigation menu