Silent Call Communications SCXMIT11 418 MHz Periodic Transmitter for use in Hearing Impaired Applications User Manual Manual

Silent Call Communications 418 MHz Periodic Transmitter for use in Hearing Impaired Applications Manual

Manual

www.silentcall.com
SCXMIT11 418Mhz Consolidated Transmitter Series
Installation Instructions
Revision IR
Date 01/12/2016
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 2 of 14
Silent Call Communications
REVISION HISTORY
Revision
#
Initiated
By
Revision
Date
Approved
by
Approval
date.
Reason
Retain this record in front of this manual. Upon receipt of this revision, insert and remove pages
accordingly. Then enter on this page, the revision number, issue date, insertion date, and your initials.
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 3 of 14
Silent Call Communications
TABLE OF CONTENTS
SECTION 1: INTRODUCTION .......................................................................................................... 4
1.1 PURPOSE: ....................................................................................................................................... 4
SECTION 2: SYSTEM DESCRIPTION ............................................................................................. 4
2.1 KEY FEATURES: .......................................................................................................................... 4
2.2 CONSOLIDATED TRANSMITTER (FA3-MC) SPECIFICATIONS: ..................................... 4
2.3 REGLATORY INFORMATION NOTICE: ................................................................................. 5
2.4 TRANSMITTER FEATURES: ...................................................................................................... 5
2.5 TRANSMITTER SETTINGS: ........................................................................................................ 5
2. 6 INPUT POWER REQUIREMENTS: ........................................................................................... 5
2.7 TRANSMITTER MOUNTING AND LOCATION: .................................................................... 5
SECTION 3: CONFIGURED TRANSMITTER INSTRUCTIONS ..................................................... 6
3.1 DB1-MC INSTALLATION: ........................................................................................................... 6
3.2 DB1-MC OPERATION: .................................................................................................................. 6
3.3 FA4-MC INSTALLATION: ........................................................................................................... 7
3.4 FA4-MC OPERATION: .................................................................................................................. 7
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 4 of 14
Silent Call Communications
SECTION 1: INTRODUCTION
1.1 PURPOSE:
This document contains information relative to the installation and operation characteristics of the Silent
Call Medallion Series SCXMIT11 Consolidated Transmitter configurations.
SECTION 2: SYSTEM DESCRIPTION
2.1 KEY FEATURES:
The Silent Call SCXMIT11Transmitter Medallion Series is a configurable 418Mhz Transmitter to be
used in conjunction with the Medallion Series Receivers. The consolidated transmitter requiring voltage
input can be configured into 2 different transmitter types depending upon the customer requirements. The
following is a list of configuable 418Mhz consolidated transmitters.
DB1-MC -- Doorbell Transmitter (Direct Wire)
FA4-MC --Fire Alarm Transmitter (Voltage Input)
2.2 CONSOLIDATED TRANSMITTER (FA3-MC) SPECIFICATIONS:
FA4-MC Mass:
FA4-MC Dimensions:
Operating Voltage:
Current Draw:
FCC ID:
IC:
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 5 of 14
Silent Call Communications
2.3 REGLATORY INFORMATION NOTICE:
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
This Device Complies With Industry Canada License-Exempt RSS Standard(s).
Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation of the device. This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver
• Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
• Consult the dealer or an experienced radio/television technician for help.
Unauthorized changes or modifications could void the user’s authority
to operate the equipment.
2.4 TRANSMITTER FEATURES:
SCXMIT11 transmitters are panel operated and will flash an YELLOW LED when the batteries are in
need of replacement. Transmitter has a test button for programming to receivers and required follow on
operational testing The RED LED will illuminate when the transmitter is actively transmitting signal to
the intended receiver.
2.5 TRANSMITTER SETTINGS:
The Silent Call Medallion Series address system is digitally encoded. All Silent Call Medallion Series
receivers are capable of receiving one million different address codes. Each Medallion Series
Transmitters has a unique code preprogrammed during manufacturing. Please refer to your receiver
manual for instruction on programming the transmitter code to the receiver.
2. 6 INPUT POWER REQUIREMENTS:
SCXMIT11 configured transmitter utilizes voltage from an auxiliary device to alert. 12VAC to 24VAC
for the DB1-MC and 12VDC to 24VDC for the FA4-MC. FA4-MC requires 12VDC to 24VDC reverse
polarity voltage for transmitter supervision to report.
2.7 TRANSMITTER MOUNTING AND LOCATION:
The Consolidated Transmitter Medallion Series Transmitter is designed for indoor use only. The
transmitter case has provisions for mounting to a nail or screw on the wall or use provided Velcro for
mounting on desktop or wall. Avoid mounting transmitter near large metal objects, other transmitting
devices in close proximity or high current appliances that will degrade the transmitter / receiver operation.
Test transmitter mounting location with receiver before mounting to ensure proper system operation.
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 6 of 14
Silent Call Communications
Adjust antenna for best results Transmission range with a Silent Call Medallion Series transmitter is about
500 feet.
SECTION 3: CONFIGURED TRANSMITTER INSTRUCTIONS
3.1 DB1-MC INSTALLATION:
1. Locate your doorbell chime unit and remove the cover.
2. Inside the chime unit, locate the terminal block with three terminals marked FRONT, REAR and
TRANS.
3. Connections Require Secondary Transformer Voltage between 12VAC to 24VAC with doorbell button
depressed.
4. Loosen the two screws but do not disconnect the attached wires.
5. Attach the two wires from the DB1-MC as follows: Red to FRONT, yellow to REAR.
6. Tighten the two screws and tuck and excess wires out of sight. Make sure all wires are clear of the
chime mechanism.
7. Replace the chime box cover.
3.2 DB1-MC OPERATION:
1. Whenever the front (or rear, if used) doorbell button is pressed, the chimes will sound as usual, the Red
LED on the face of the doorbell transmitter will light up and the transmitter will send a signal to any
Silent Call Medallion Series Receiver activating the receiver.
2. Both the front and rear doorbell buttons will activate the doorbell transmitter with compatible chime
units.
3. Quick reference Document # 109104
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 7 of 14
Silent Call Communications
3.3 FA4-MC INSTALLATION:
Please contact a licensed fire alarm installer for installation and working with this product. Improper installation can damage
your fire alarm and/or prevent proper operation of the fire alarm. Technical support is available at (800) 572-5227.
The FA4-MC is designed to interface with a filtered supervised fire panel notification appliance circuit. 12VDC to 24VDC
Reverse Polarity voltage will power the transmitter for supervision reporting to Silent Call Receiver if applicable.
1. Identify Fire Panel NAC specifications. Filtered panels only. NAC alert voltage 12VDC to 24VDC
positive polarity. 12VDC to 24VDC reverse polarity required for Silent Call supervision.
2. Connect the FA4-MC to a switched 12 or 24VDC voltage output from the fire panel NAC-- OR -- to the
24V horn / strobe output.
3. Follow Fire panel wiring requirements. Transmitter is a supervised power limited device.
4. Using Test Button with alarm in standby check for proper receiver operation before mounting.
5. Transmitters interfaced with Fire Panel with no supervision voltage will require a non-supervised
receiver. Test Button will not operate without reverse polarity voltage.
6. Transmitter must be programmed with Medallion Receiver. Follow Programming procedure in Receiver
installation manual.
7. Reference Silent Call FA4-MC Installation Drawing 20-300-022-01FA4.
3.4 FA4-MC OPERATION:
1. FA4-MC will transmit when the input voltage has positive polarity. Fire Alarm active.
2. When the FA4-MC transmitter is activated the Red LED on the face of the transmitter lights up. The
transmitter then sends an RF signal to a preprogrammed Silent Call Medallion Series Receiver activating
the FIRE Alert on the Receiver.
3. Applicable receivers will supervise fire transmitter operation and alert the user to Transmitter/NAC
fault.
4. Weekly testing of Auxiliary alerting system is recommended.
5. Quick reference Document # 109115.
The FA4-MC in conjunction with a Silent Call Medallion Series receiver is considered an
Supplementary Visible Notification Appliance.
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 8 of 14
Silent Call Communications
Technical Support
For technical support on this or any other Silent Call product, please feel free to contact us. You can reach us by phone at 800-
572-5227 (voice or TTY) or by Email at support@silentcall.com
CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE
MANUFACTURER COULD VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT,
Limited Warranty
Your transmitter is warranted to be free of defects in material and workmanship for five years from the date of initial purchase.
During that time, the unit will be repaired or replaced free of charge when shipped prepaid to Silent Call Communications. This
warranty is void if the defect is caused by customer abuse or neglect.
Return for Serving To:
Silent Call Communications
5095 Williams Lake Road, Waterford Michigan 48329
(800) 572-5227 v/tty (248) 673-7360 fax
Website: www.silentcall.com Email: silentcall@silentcall.com
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 9 of 14
Silent Call Communications
SCXMIT11 418Mhz Consolidé Émetteur Série
Instructions D'Installation
Traduction Français
TABLE DES MATIÈRES
SECTION 1: INTRODUCTION .................................................................................................................................. 10
1.1 OBJECTIF: ................................................................................................................................................................................. 10
SECTION 2: DESCRIPTION DU SYSTÈME ........................................................................................................... 10
2.1 CARACTÉRISTIQUES PRINCIPALES: ........................................................................................................................................... 10
2.2 SPÉCIFICATIONS DE L'ÉMETTEUR CONSOLIDÉ (FA4-MC): .......................................................................................................... 10
2.3 AVIS D'INFORMATION REGLATORY: .......................................................................................................................................... 11
2.4 CARACTÉRISTIQUES DE L'ÉMETTEUR: ........................................................................................................................................ 11
2.5 PARAMÈTRES DE L'ÉMETTEUR: ................................................................................................................................................. 11
2.6 TENSION D'ENTRÉE REQUISE: ................................................................................................................................................... 11
2.7 EMPLACEMENT ET MONTAGE DE L'ÉMETTEUR: ......................................................................................................................... 11
SECTION 3: INSTRUCTIONS DE L'ÉMETTEUR CONFIGURÉ ............................................................................. 12
3.1 INSTALLATION DE DB1-MC:....................................................................................................................................................... 12
3.2 DB1-MC OPÉRATION: ................................................................................................................................................................ 12
3.3 INSTALLATION DE FA4-MC: ....................................................................................................................................................... 13
3.4 FA4-MC OPÉRATION: ................................................................................................................................................................ 13
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 10 of 14
Silent Call Communications
SECTION 1: INTRODUCTION
1.1 OBJECTIF:
Ce document contient des informations relatives à des caractéristiques installation et l'utilisation des
configurations de silencieux appeler médaillon série SCXMIT11 Consolidated émetteur.
SECTION 2: DESCRIPTION DU SYSTÈME
2.1 CARACTÉRISTIQUES PRINCIPALES:
La série Silent Call SCXMIT11Transmitter médaillon est un configurable 418 Mhz transmetteur pour
être utilisé en conjonction avec les récepteurs de la gamme Medallion. L'émetteur consolidé nécessitant
une tension d'entrée peut être configuré en 2 types d'émetteur différent selon les exigences du client. Ce
qui suit est une liste d'émetteurs de 418Mhz consolidé configuable.
DB1-MC--Sonnette Émetteur (Câblage Direct)
FA4-MC--Transmetteur D'alarme D'incendie (Tension D'entrée)
2.2 SPÉCIFICATIONS DE L'ÉMETTEUR CONSOLIDÉ (FA4-MC):
FA4-MC Mass:
FA4-MC Dimensions:
Tension D'opération :
Appel De Courant :
FCC ID:
IC:
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 11 of 14
Silent Call Communications
2.3 AVIS D'INFORMATION REGLATORY:
CET APPAREIL EST CONFORME À LA PARTIE 15 DES RÈGLES FCC.
Cet Appareil Est Conforme Avec Industrie Canada Exemptes De Licence RSS Ou Les Normes.
Son fonctionnement est sujet aux deux conditions suivantes: (1) cet appareil ne doit pas émettre de
brouillage nuisible, et (2) cet appareil doit accepter toute interférence reçue, y compris les
interférences pouvant entraîner un fonctionnement indésirable du dispositif. Cet équipement a été
testé et déclaré conforme aux limites d'un appareil numérique de classe B, conformément à l'article
15 des règlements FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les
interférences nuisibles dans une installation résidentielle. Cet équipement génère, utilise et peut
émettre de l'énergie de fréquence radio et si pas installé et utilisé conformément aux instructions,
peut causer des interférences nuisibles aux communications radio. Cependant, il n'y a aucune
garantie que des interférences n'interviendront pas dans une installation particulière. Si cet
équipement provoque des interférences nuisibles à la réception radio ou télévision, ce qui peut être
déterminée en éteignant et rallumant l'équipement, l'utilisateur est encouragé à essayer de corriger
ces interférences en appliquant une ou plusieurs des mesures suivantes: Réorientez ou déplacez
l'antenne de réception.
• Augmenter la distance entre l'équipement et le récepteur
• Branchez l'appareil dans une prise sur un circuit différent de celui auquel le récepteur est branché.
• Consultez le revendeur ou un technicien expérimenté en radio/télévision pour aide
Toute modification non autorisée pourrait annuler autorisation votre d'utiliser l'équipement.
2.4 CARACTÉRISTIQUES DE L'ÉMETTEUR:
SCXMIT11 émetteurs sont exploités et se met à clignoter une LED jaune lorsque les piles doivent être
remplacées. Émetteur dispose d'un bouton de test pour la programmation à des récepteurs et requis suivi
opérationnel essai The RED LED s'allume lorsque l'émetteur transmet activement signal au récepteur
prévu.
2.5 PARAMÈTRES DE L'ÉMETTEUR:
Le système d'adresses Silent Call médaillon série est codé numériquement. Tous les récepteurs de la
série de médaillon Silent Call sont capables de recevoir 1 million de codes adresse différente. Chaque
médaillon émetteurs de la série a un code unique programmé pendant la fabrication. Veuillez vous
référer au manuel de votre récepteur pour la formation sur la programmation du code de l'émetteur au
récepteur.
2.6 TENSION D'ENTRÉE REQUISE:
SCXMIT11 configuré émetteur utilise la tension d'un dispositif auxiliaire d'alerte. 12VAC de 24VAC
pour le DB1-MC et 12VDC à 24VDC pour la SEA4-MC. SA4-MC nécessite 12VDC à 24 VDC tension
de polarité inversée pour surveillance d'émetteur au rapport.
2.7 EMPLACEMENT ET MONTAGE DE L'ÉMETTEUR:
La Consolidated médaillon série l'émetteur est conçu pour une utilisation en intérieur uniquement. Le
cas de l'émetteur comporte des dispositions pour le montage sur un clou ou une vis sur le mur ou l'usage
prévu de Velcro pour un montage sur bureau ou murale. Éviter l'émetteur de montage près de grands
objets métalliques, autres appareils de transmission à proximité ou hautes appareils actuels qui vont se
dégrader l'émetteur / récepteur fonctionnement. L'emplacement de montage émetteur avec récepteur
avant le montage afin d'assurer le bon fonctionnement du système d'essai. Régler l'antenne pour de
meilleurs résultats, portée de Transmission avec un émetteur de la série de médaillon Silent Call est
d'environ 500 pieds.
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 12 of 14
Silent Call Communications
SECTION 3: INSTRUCTIONS DE L'ÉMETTEUR CONFIGURÉ
3.1 INSTALLATION DE DB1-MC:
1. Repérez votre carillon sonnette et enlever le couvercle.
2. À l'intérieur de l'unité de carillon, placer la plaque à bornes avec trois bornes avant, arrière et TRANS.
3. Les connexions requièrent secondaire transformateur tension entre 12VAC à 24VAC avec bouton de
sonnette de porte enfoncé.
4. Desserrez les deux vis mais ne pas déconnecter les câbles attachés.
5. Attachez les deux fils de la DB1-MC comme suit : rouge vers l'avant, jaune à l'arrière.
6. Serrer les deux vis et les tuck et les excès fils hors de la vue. Assurez-vous que tous les fils sont libres
du mécanisme du carillon.
7. Remettez le couvercle de boîte de carillon.
3.2 DB1-MC OPÉRATION:
1. Chaque fois que l'avant (ou arrière, si utilisée) vous appuyez sur le bouton de sonnette, le carillon retentit comme d'habitude,
la LED rouge sur le visage de l'émetteur de sonnette de porte s'allume et l'émetteur enverra un signal à n'importe quel
récepteur silencieux de série médaillon appellent à l'activation du récepteur.
2. Les boutons de sonnette de porte arrière et avant pour activer la sonnette émetteur avec carillon compatible unités.
3. Quick reference Document # 109104
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 13 of 14
Silent Call Communications
3.3 INSTALLATION DE FA4-MC:
Pour l'installation et l'utilisation de ce produit, veuillez communiquer avec un installateur d'alarme incendie sous licence.
Une installation incorrecte peut endommager votre alarme incendie et/ou empêcher le bon fonctionnement de l'alarme.
incendie. Le support technique est disponible au (800) 572-5227.
La FA4-MC est conçu pour s'interfacer avec un circuit d'appareil filtré sous surveillance incendie panneau notification.
12VDC à 24 VDC tension de polarité inverse motorisera l'émetteur contrôle rapports au récepteur d'appel silencieux, le cas
échéant.
1. Identifier les spécifications de feu panneau du CNA. Panneaux filtrées uniquement. CNA alerte tension
12VDC à polarité positive 24VDC. 12VDC à polarité inversée 24VDC requise pour appeler silencieuse
de supervision.
2. Connectez la SEA4-MC pour commuté 12 ou 24 VDC tension de sortie de la centrale incendie du CNA-
-OR--au klaxon 24V / sortie stroboscopique.
3. Suivez les exigences de câblage pour le panneau incendie. Émetteur est un appareil limité de puissance
surveillée.
4. En utilisant le bouton de Test avec alarme en veille échec pour bon fonctionnement avant le montage.
5. Les émetteurs interfacés avec centrale incendie aucune tension de surveillance nécessitera un récepteur
non surveillé. Bouton de test ne fonctionnera pas sans tension de polarité inversée.
6. L'émetteur doit être programmé avec médaillon récepteur. Suivez la procédure de programmation dans
le manuel d'installation de récepteur.
7. Schéma d'Installation silencieux appel SEA4-MC 20-300-022-01FA4 de référence.
3.4 FA4-MC OPÉRATION:
1. FA4-MC transmettra lorsque la tension d'entrée est de polarité positive. Active l'alarme incendie..
2. Lorsque l'émetteur SEA4-MC est activé, la LED rouge sur le visage de l'émetteur s'allume. L'émetteur
envoie alors un signal RF à un préprogrammé Silent Call médaillon série récepteur activer l'alerte
incendie sur le récepteur.
3. Applicables récepteurs vont superviser le fonctionnement de l'émetteur de feu et alerter l'utilisateur de la
faute de l'émetteur/du CNA.
4. Test des auxiliaires hebdomadaire avertisseur est recommandé.
5. Quick reference Document # 109115.
Le FA4-MC en conjonction avec un récepteur de la série de médaillon Silent Call est considéré
comme un appareil de signal Visible supplémentaire.
SCXMIT11 418Mhz Consolidated Transmitter Installation Document
Document # 20-325-018-02 Rev IR Page 14 of 14
Silent Call Communications
Support Technique
Pour le support technique à ce sujet ou tout autre produit d'appel silencieux, s'il vous plaît n'hésitez pas à nous contacter. Vous pouvez
nous joindre par téléphone au 800-572-5227 (voix ou TTY), ou par courriel à support@silentcall.com
LES CHANGEMENTS OU MODIFICATIONS NON EXPRESSÉMENT APPROUVÉS PAR LE FABRICANT PEUVENT
ANNULER AUTORISATION VOTRE D'UTILISER L'ÉQUIPEMENT.
Garantie Limitée
Votre émetteur est garanti exempt de tout vice de matériau et de fabrication pendant cinq ans suivant la date d'achat initiale. Pendant
ce temps, l'appareil sera réparé ou remplacé gratuitement lors de l'expédition prépayée à Silent Call Communications. Cette garantie
est nulle si le défaut est causé par la mauvaise utilisation ou négligence.
Retour pour le service à:
Silent Call Communications
5095 Williams Lake Road, Waterford Michigan 48329
(800) 572-5227 v/tty (248) 673-7360 fax
Website: www.silentcall.com Email: silentcall@silentcall.com